SEM Grid Testing at NLCTA in BeamNetUS Program

We report on the performance of a secondary electron monitor (SEM) grid used to measure the transverse profile of an MeV range electron beam at SLAC National Accelerator Laboratory’s Next Linear Collider Test Accelerator (NLCTA) facility. When inserted into the path of the electron beam, secondary electron emission results in a measurable current on the wires that make up the grid. We present measurements using this technique to reconstruct the beam profile. The SEM grid was designed and manufactured by a team of undergraduate students at Harvey Mudd College (HMC) and was tested at SLAC’s NLCTA facility in collaboration with NCLTA staff as part of the BeamNetUS program. Developed for real-time diagnostics of MeV-range electron beams, this SEM grid has potential applications in both industrial and medical contexts.

43 PARTICLE ACCELERATORS↗

SU-F-T-88: Field’s Metal for Electron Beam Inserts and Blocks

Purpose: The aim of this work is to show that Field’s metal can be used as a viable alternative material to lead-based low-melting temperature alloys (e.g., Cerrobend) for electron beam inserts and blocks. The goal is to eliminate exposure risks associated with lead and cadmium. Methods: Field’s metal (51% Indium, 32.5% Bismuth, 16.5% Tin) is a low-melting point eutectic alloy, and is proposed as a lead-free replacement for Cadmium-free alloy (52.5% Bismuth, 32% Lead, 15.5% Tin). The experiments were done using a Varian 21EX linac equipped with 6, 9, 12, and 16 MeV beams. The 10×10 cone was used with 1.8cm thick insert made of Fields metal, Cd-Free alloy or open field. The transmitted radiation was measured using a diode at various depths in water. Block transmission factor (BTF) is determined as the ratio of maximum transmission radiation dose over the dose at dmax of the open field. Results: The data shows BTFs for both alloys are very similar, well below 5% for 6, 9, and 12 MeV beams. For 16 MeV, the BTF of the Fields metal is about 5.3%; the Cd-free metal 4.2%. The peak dose of the transmitted radiation occurs less than 1 cm below the water surface, at a much shallower depth than the dmax of the electron beam in the open field. The beam profile shows the maximum block transmission is along the central axis of the beam. Conclusion: The present study shows that Fields metal can be used to make electron cutouts and blocks for 6, 9, 12, and 16 MeV beams. Because it has a similar density as other lead-based alloys, the same thickness of Fields metal would be adequate for shielding the electron beams. This means that it can be used as a replacement without modification to the existing block holder.

43 PARTICLE ACCELERATORS↗

Generation of directional, coherent matter beams through dynamical instabilities in Bose-Einstein condensates

We present a theoretical analysis of a coupled, two-state Bose-Einstein condensate with nonequal scattering lengths and show that dynamical instabilities can be excited. We demonstrate that these instabilities are exponentially amplified, resulting in highly directional, oppositely propagating, coherent matter beams at specific momenta. To accomplish this we prove that the mean field of our system is periodic and extend the standard Bogoliubov approach to consider a time-dependent, but cyclic, background. This allows us to use Floquet's theorem to gain analytic insight into such systems, rather than employing the usual Bogoliubov-de Gennes approach, which is usually limited to numerical solutions. We apply our theory to the metastable helium atom laser experiment by Dall et al. [Phys. Rev. A 79, 011601(R) (2009)] and show that it explains the anomalous beam profiles they observed. Finally, we demonstrate that the paired particle beams will be Einstein-Podolsky-Rosen entangled on formation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-340: Dosimetry of a Small Field Electron Beam for Innovative Radiotherapy of Small Surface Or Internal Tumors

Purpose: An innovative small high intensity electron beams with energies from 6 to 12 MeV is being developed at Argonne National Laboratory to deliver an absorbed dose via a catheter to small malignant and nonmalignant lesions. This study reports on the initial dosimetric characteristics of this electron beam. These include output calibration, percent depth dose, beam profiles and leakage through the catheter. Methods: To simulate the narrow electron beam, the Argonne Wakefield Accelerator is used to produce high energy electron beams. The electron beam from the accelerator is monitored by measuring the current through a transmission coil while the beam shape is observed with a fluorescent screen. The dosimetry properties of the electron beam transmitting through bone and tissue-like materials are measured with nanodot optically stimulated luminescent dosimeters and EDR radiographic film. The 6 MV photon beam from a Varian True beam linac is used to calibrate both the OSLDs and the film. Results: The beam characteristics of the 12 MeV beam were measured. The properties of the small diameter, 5 mm, beam differs from that of broad clinical electron beams from radiotherapy linacs. Due to the lack of scatter from the narrow beam, the maximum dose is at the surface and the depth of the 50% depth dose is 35 mm compared to 51 mm for a clinical 12 MeV. The widths of the 90% isodose measured at the surface and depths of 2, 6, 12, and 16 mm varied from 6.6 to 8.8 mm while the widths of the FWHM isodose varied from 7.8 to 25.5 mm. Conclusion: Initial beam measurements show favorable dosimetric properties for its use in treating either small surface or internal lesions, particularly to deliver radiation at the time of surgery to maximize the dose to the lesion and spare normal tissue.

60 APPLIED LIFE SCIENCES↗

Characterization of the acoustic field generated by a horn shaped ultrasonic transducer

A horn shaped Langevin ultrasonic transducer used in a single axis levitator was characterized to better understand the role of the acoustic profile in establishing stable traps. The method of characterization included acoustic beam profiling performed by raster scanning an ultrasonic microphone as well as finite element analysis of the horn and its interface with the surrounding air volume. The results of the model are in good agreement with measurements and demonstrate the validity of the approach for both near and far field analyses. Our results show that this style of transducer produces a strong acoustic beam with a total divergence angle of 10 degree, a near-field point close to the transducer surface and a virtual sound source. These are desirable characteristics for a sound source used for acoustic trapping experiments

acoustic, horn, levitation, acoustic simulation↗

SU-F-T-371: Development of a Linac Monte Carlo Model to Calculate Surface Dose

Purpose: To generate and validate a linac Monte Carlo (MC) model for surface dose prediction. Methods: BEAMnrc V4-2.4.0 was used to model 6 and 18 MV photon beams for a commercially available linac. DOSXYZnrc V4-2.4.0 calculated 3D dose distributions in water. Percent depth dose (PDD) and beam profiles were extracted for comparison to measured data. Surface dose and at depths in the buildup region was measured with radiochromic film at 100 cm SSD for 4 × 4 cm{sup 2} and 10 × 10 cm{sup 2} collimator settings for open and MLC collimated fields. For the 6 MV beam, films were placed at depths ranging from 0.015 cm to 2 cm and for 18 MV, 0.015 cm to 3.5 cm in Solid Water™. Films were calibrated for both photon energies at their respective dmax. PDDs and profiles were extracted from the film and compared to the MC data. The MC model was adjusted to match measured PDD and profiles. Results: For the 6 MV beam, the mean error(ME) in PDD between film and MC for open fields was 1.9%, whereas it was 2.4% for MLC. For the 18 MV beam, the ME in PDD for open fields was 2% and was 3.5% for MLC. For the 6 MV beam, the average root mean square(RMS) deviation for the central 80% of the beam profile for open fields was 1.5%, whereas it was 1.6% for MLC. For the 18 MV beam, the maximum RMS for open fields was 3%, and was 3.1% for MLC. Conclusion: The MC model of a linac agreed to within 4% of film measurements for depths ranging from the surface to dmax. Therefore, the MC linac model can predict surface dose for clinical applications. Future work will focus on adjusting the linac MC model to reduce RMS error and improve accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electrostatic storage ring with focusing provided by the space charge of an electron plasma

Electrostatic storage rings are used for a variety of atomic physics studies. An advantage of electrostatic storage rings is that heavy ions can be confined. An electrostatic storage ring that employs the space charge of an electron plasma for focusing is described. An additional advantage of the present concept is that slow ions, or even a stationary ion plasma, can be confined. The concept employs an artificially structured boundary, which is defined at present as one that produces a spatially periodic static field such that the spatial period and range of the field are much smaller than the dimensions of a plasma or charged-particle beam that is confined by the field. An artificially structured boundary is used to confine a non-neutral electron plasma along the storage ring. The electron plasma would be effectively unmagnetized, except near an outer boundary where the confining electromagnetic field would reside. The electron plasma produces a radially inward electric field, which focuses the ion beam. Self-consistently computed radial beam profiles are reported.

43 PARTICLE ACCELERATORS↗

Observation of weakly and strongly diverging ion beams in a magnetically expanding plasma

The spatial distribution of an ion beam created in a magnetically expanding plasma using permanent magnets is experimentally investigated for 0.35 and 1 mTorr, where the magnetic-field strength is about 100 G in the plasma source and is decreasing into a few gauss in the diffusion chamber. The beam profile for 0.35 mTorr is weakly divergent. On the other hand, the strongly diverging beam is detected for 1 mTorr. The results are discussed from the viewpoint of the plasma-potential structures and imply the beam divergence caused by the radial electric fields in the ion acceleration region and the diffusion chamber.

43 PARTICLE ACCELERATORS↗

Synchrotron radiation based beam diagnostics at the Fermilab Tevatron

Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. Therefore, if one utilizes the radiation originating near the edge of a bending magnet, or from a short magnet, the rapidly changing magnetic field serves to enhance the wavelengths shorter than the cutoff wavelength, which for more recent high energy proton accelerators such as Fermilab's Tevatron, tends to be visible light. This paper discusses the implementation at the Tevatron of two devices. A transverse beam profile monitor images the synchrotron radiation coming from the proton and antiproton beams separately and provides profile data for each bunch. A second monitor measures the low-level intensity of beam in the abort gaps which poses a danger to both the accelerator's superconducting magnets and the silicon detectors of the high energy physics experiments. Comparisons of measurements from the profile monitor to measurements from the flying wire profile systems are presented as are a number of examples of the application of the profile and abort gap intensity measurements to the modelling of Tevatron beam dynamics.

43 PARTICLE ACCELERATORS↗

SU-E-T-145: Beam Characteristics of Flattening Filter Free Beams Including Low Dose Rate Setting

Purpose: In commissioning of volumetric modulated arc therapy (VMAT), it is necessary to evaluate the beam characteristics of various dose rate settings with potential to use. The aim of this study is to evaluate the beam characteristics of flattened and flattening filter free (FFF) including low dose rate setting. Methods: We used a Varian TrueBeam with Millennium 120 MLC. Both 6 and 10 MV beams with or without flattening filter were used for this study. To evaluate low-dose rate FFF beams, specially-designed leaf sequence files control out-of-field MLC leaf pair at constant dose rate ranging from 80 to 400 MU/min. For dose rate from 80 MU/min to the maximum usable value of all energies, beam output were measured using ionization chamber (CC04, IBA). The ionization chamber was inserted into water equivalent phantom (RT3000-New, R-tech), and the phantom was set with SAD of 100cm. The beam profiles were performed using the 2D diode array (Profiler2, Sun Nuclear). The SSD was set to 90cm and a combined 30cmx30cmx9cm phantom which consisted of solid water slabs was put on the device. All measurement were made using 100MU irradiation for 10cmx10cm jaw-defined field size with a gantry angle of 0°. Results: In all energies, the dose rate dependences with beam output and variation coefficient were within 0.2% and 0.07%, respectively. The flatness and symmetry exhibited small variations (flatness ≤0.1 point and symmetry≤0.3 point at absolute difference). Conclusion: We had studied the characteristics of flattened and FFF beam over the 80 MU/min. Our results indicated that the beam output and profiles of FFF of TrueBeam linac were highly stable at low dose rate setting.

60 APPLIED LIFE SCIENCES↗

Improved control of electron computer-generated holographic grating groove profiles using ion beam gas-assisted etching

In a transmission electron microscope, electrons are described by matter-waves with wavelengths five orders of magnitude smaller than optical electromagnetic waves. Analogous to optical holography, electron wavefronts can be shaped using nanoscale holographic gratings. Here we demonstrate a novel, scalable nanofabrication method for creating off-axis holographic gratings that demonstrate near ideal diffraction efficiencies for binary, sinusoidal, and blazed grating groove profiles. We show that this method can produce up to 50 µm diameter area gratings that diffract up to 68% of the transmitted electron wave into a desired diffraction order with less than 7% into any other order. Additionally, we find that the amount of inelastically scattered electrons from the material gratings remaining in the coherent diffraction orders from the gratings is negligible in the far field.

Johnson, Cameron W.↗

Image mapping for multiple charge state beams using a beam induced fluorescence profile monitors

Work continues on a minimally invasive, nitrogen fluorescence gas sheet at the Facility for Rare Isotope Beams (FRIB). A low density gas sheet may be used to observe the 2D transverse beam profile of high intensity, multiple charge state beams with minimal interference. Spatially and temporally correlated profiles are of particular interest in locations where there is significant charge state spread, such as the FRIB linac folding segments. A low-density gas sheet measurement system offers advantages for gas handling in nitrogen sensitive areas, however signal intensity is significantly lower than techniques using higher density gas sheets and jets. This work discusses measurement considerations for photon distributions generated by several spatially separated interaction points and design considerations for a high-sensitivity optics system for handling the expected low signal intensity.

Accelerator Physics↗

Pressurized Gas Beam Monitor for Extremely High Intensities – Phase II

A novel pressurized gas-filled multi-RF-cavity beam profile monitor has been studied that is simple and robust in high-radiation environments. Charged particles passing through each RF-cavity in the monitor produce intensity-dependent ionized plasma, which changes the gas permittivity. Standard RF techniques to measure the change in quality factor (Q) and frequency (f) as a function of time are then used to determine the change in permittivity and corresponding beam intensity in each cavity in the profile monitor. The sensitivity to beam intensity is adjustable using gas pressure and RF gradient. The performance of the gas-filled beam profile monitor has been numerically simulated to evaluate the sensitivity of permittivity measurements and the effectiveness of calibration strategies. An entire multi-RF-cavity system has been designed and a demonstration test has been prepared.

43 PARTICLE ACCELERATORS↗

Feasibility of OTR imaging of non-relativistic ions at GSI

The feasibility of using the optical transition radiation (OTR) generated as a 11.4- to 300-MeV/u ion beam passes through a single metal conducting plane for a minimally intercepting beam profile monitor for GSI/Darmstadt has been evaluated for the first time. Although these are non-relativistic beams, their beta and gamma values are similar to the 80-keV electron-beam imaging studies previously done on the CTF3 injector. With anticipated beam intensities of 10{sup 9} to 10{sup 11} particles per pulse and the predicted charge-squared dependence of OTR, the ion charge state becomes a critical factor for photon production. The OTR signal from the ion charge integrated over the video field time should be comparable to or larger than the CTF3 electron case. These signal strengths will allow a series of experiments to be done that should further elucidate the working regime of this technique.

43 PARTICLE ACCELERATORS↗

TH-C-18A-04: Validation of Dosimetric Measurement of CT Radiation Profile Width

Purpose: The ACR now requires that the CT radiation profile width be measured at all clinically used collimations. We developed a method for measuring the profile width using dosimetry alone to allow a faster and simpler measurement of beam widths. Methods: A pencil ionization chamber is used to take two dose-length product measurements in air for a wide collimation. One of these is taken with a 1cm tungsten mask on the pencil chamber. The difference between these measurements is the calibration factor, or the DLP in air per unit length. By dividing the doselength product for any given collimation by this factor, we can rapidly determine the beam profile width.We measured the beam width for all available detector configurations and focal spot sizes on three different CT scanners from two different manufacturers. The measurements were done using film, CR cassette, and the present dosimetric method. Results: The beam widths measured dosimetrically are approximately 2% wider than those measured using film or computed radiography; this difference is believed due to off-focus or scattered radiation. After correcting for this, the dosimetric beam widths match the film and CR widths with an RMS difference of approximately 0.2mm. The measured beam widths are largely insensitive to errors in positioning of the mask, or to tilt errors in the pencil chamber. Conclusion: Using the present method, radiation profile widths can be measured quickly, with an accuracy better than 1mm.

07 ISOTOPE AND RADIATION SOURCES↗

TRANSVERSE MATCHING OF THE SNS LINAC BASED ON PROFILE MEASUREMENTS

For a high intensity linac such as the SNS linac, it matters to match transversely adequately to minimize the beam mismatch and potential beam loss. The technique of doing the matching using the wire-scanners in series was employed [1]. It was verified that matching was improved through the matching technique based on the beam profile measurements from wire-scanners in series.

43 PARTICLE ACCELERATORS↗

CMS Pixel Telescope Addition to T-980 Bent Crystal Collimation Experiment at the Tevatron

An enhancement to the T-980 bent crystal collimation experiment at the Tevatron has been completed. The enhancement was the installation of a pixel telescope inside the vacuum-sealed beam pipe of the Tevatron. The telescope is comprised of six CMS PSI46 pixel plaquettes, arranged as three stations of horizontal and vertical planes, with the CAPTAN system for data acquisition and control. The purpose of the pixel telescope is to measure beam profiles produced by bent crystals under various conditions. The telescope electronics inside the beam pipe initially were not adequately shielded from the image current of the passing beams. A new shielding approach was devised and installed, which resolved the problem. The noise issues encountered and the mitigating techniques are presented herein, as well as some preliminary results from the telescope.

43 PARTICLE ACCELERATORS↗

LANSCE harp upgrade: analysis, design, fabrication and installation

The primary goal of this newly installed beam profile measurement is to provide the facility operators and physicists with a reliable horizontal and vertical projected beam distribution and location with respect to the proton beam target and beam aperture. During a 3000-hour annual run cycle, 5 {mu}C of charge is delivered every 50 milliseconds through this harp to the downstream TRMS Mark III target. The resulting radioactive annual dose near this harp is at least 6 MGy. Because of this harsh environment, the new harp design has been further optimized for robustness. For example, compared to an earlier design, this harp has half of the sensing wires and utilizes only a single bias plane. The sensing fibers are 0.079-mm diameter SiC fibers. To hold these fibers to a rigid ceramic structure, a collet fiber-clamping device accomplishes the three goals of maintaining a mechanical fiber clamp, holding the sense fibers under a slight tensile force, and providing a sense-fiber electrical connection. This paper describes the harp analysis and design, and provides fabrication, assembly, and some installation information, and discusses wiring alterations.

43 PARTICLE ACCELERATORS↗