Search NASA⌕ Search

SEARCH · Search NASA

Results for “BETA DECAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Search for neutrinoless β-plus-EC decay of 120 Te with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a large-scale cryogenic experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than 130 Te. In this work we describe a search for neutrinoless positron-emitting electron capture (β + EC ) decay in 120 Te with a total TeO 2 exposure of 355.7 kg yr, corresponding to 0.2405 kg yr of 120 Te. Albeit 0νββ with two final-state electrons represents the most promising channel, the emission of a positron and two 511-keV γ 's make 0νβ + EC decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of 3.4 × 10 22 yr at 90% credibility interval (C.I.). After unblinding we find no evidence of 0νβ + EC signal and set a 90% C.I. Bayesian lower limit of 2.9 × 10 22 yr on 120 Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparative study of He 6 β -decay based on different similarity-renormalization-group evolved chiral interactions

We report on a study of the Gamow-Teller matrix element contributing to ${}^6$He $\beta$-decay with similarity renormalization group (SRG) versions of momentum- and configuration-space two-nucleon interactions. These interactions are derived from two different formulations of chiral effective field theory ($\chi$EFT) -- without and with the explicit inclusion of $\Delta$-isobars. We consider evolution parameters $\Lambda_{\rm SRG}$ in the range between 1.2 and 2.0 fm$^{-1}$ and, for the $\Delta$-less case, also the unevolved (bare) interaction. The axial current contains one- and two-body terms, consistently derived at tree level (no loops) in the two distinct $\chi$EFT formulations we have adopted here. The ${}^6$He and ${}^6$Li ground-state wave functions are obtained from hyperspherical-harmonics (HH) solutions of the nuclear many-body problem. In $A\,$=$\,6$ systems, the HH method is limited at present to treat only two-body interactions and non-SRG evolved currents. Our results exhibit a significant dependence on $\Lambda_{\text{SRG}}$ of the contributions associated with two-body currents, suggesting that a consistent SRG-evolution of these is needed in order to obtain reliable estimates. We also show that the contributions from one-pion-exchange currents depend strongly on the model (chiral) interactions and on the momentum- or configuration-space cutoffs used to regularize them. These results might prove helpful in clarifying the origin of the sign difference recently found in No-Core-Shell-Model and Quantum Monte Carlo calculations of the ${}^6$He Gamow-Teller matrix element.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rare multinucleon decays with the full data sets of the M AJORANA D EMONSTRATOR

The M AJORANA D EMONSTRATOR was an ultra-low-background experiment designed for neutrinoless double-beta decay (0⁢𝜈⁢𝛽⁢𝛽) investigation in 76 Ge . Located at the Sanford Underground Research Facility in Lead, South Dakota, the D EMONSTRATOR utilized modular high-purity Ge detector arrays within shielded vacuum cryostats, operating deep underground. The arrays, with a capacity of up to 40.4 kg (27.2 kg enriched to ∼88% in 76 Ge ), have accumulated the full data set, totaling 64.5 kg yr of enriched active exposure and 27.4 kg yr of exposure for natural detectors. Here, our updated search improves previously explored three-nucleon decay modes in Ge isotopes, setting new partial lifetime limits of 1.83 × 10 26 yr (90% confidence level) for 76 Ge (𝑝⁢𝑝⁢𝑝) → 73 Cu 𝑒 + ⁢𝜋 + ⁢𝜋 + and 76 Ge (𝑝⁢𝑝⁢𝑛) → 73 Zn 𝑒 + ⁢𝜋 + . The partial lifetime limit for the fully inclusive triproton decay mode of 76 Ge is found to be 2.1×10 25 yr. Furthermore, we have updated limits for corresponding multinucleon decays.

baryon & lepton number symmetries↗

Weak Transitions in Light Nuclei

Nuclei are used for high-precision tests of the Standard Model and for studies of physics beyond the Standard Model. Without a thorough understanding of nuclei, we will not be able to meaningfully interpret the growing body of experimental data nor will we be able to disentangle new physics signals from underlying nuclear effects. This calls for accurate calculations of nuclear structure and reactions. In this work, we focus on electroweak decays in nuclei with mass number A ≤ 10 and report on ab initio Quantum Monte Carlo calculations of reduced matrix elements entering beta decays and electron captures in nuclei with mass number A ≤ 10. The many-body wave functions are calculated using selected Norfolk two- and three-nucleon potential models and associated one- and two-body axial currents at tree-level obtained from a chiral effective field theory with pions, nucleons, and Δ. The agreement with the experimental data is satisfactory except for transitions in A = 8 nuclei. In this specific case, the theory significantly underpredicts the experimental data, which indicates the need of further improvements in the corresponding nuclear wave functions. In this study, emphasis is placed on the contributions of two-body axial currents that are carefully analyzed using two-body transition densities. This allow us to study the spatial distribution and short-range behavior of two-body dynamics. In particular, the transition densities when scaled to peak at 1.0 exhibit universal short-range behavior across the considered nuclei, while they differ in the long-range tails.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flow-dependent tagging of 214 Pb decays in the LZ dark matter detector

The LUX-ZEPLIN (LZ) experiment is searching for dark matter interactions in a liquid xenon time projection chamber (LXe-TPC). This article demonstrates how control of the flow state in the LXe-TPC enables the identification of pairs of sequential alpha-decays, which are used to map fluid flow and ion drift in the liquid target. The resulting transport model is used to tag 214 Pb~ beta-decays, a leading background to dark matter signals in LZ. Temporally evolving volume selections, at a cost of 9.0% of exposure, target the decay of each 214 Pb~ atom up to 81 minutes after production, resulting in (63±6 (s⁢t⁢a⁢t) ±7 (s⁢y⁢s) )% identification of 214 Pb~decays to ground state. We also demonstrate how flow-based tagging techniques enable a novel calibration side band that is concurrent with science data. Lastly we report updated estimates of radon-chain charge branching fractions in liquid xenon, finding branching to 218 Po + at 0.49±0.01, 214 Pb + at 0.48±0.12, and 214 Bi + at 0.74±0.05, with a mean charged ion lifetime in the LZ TPC of 49±4 min.

Lorenzon, Wolfgang [University of Michigan, Ann Ar↗

Flow-dependent tagging of $^{214}$Pb decays in the LZ dark matter detector

The LUX-ZEPLIN (LZ) experiment is searching for dark matter interactions in a liquid xenon time projection chamber (LXe-TPC). This article demonstrates how control of the flow state in the LXe-TPC enables the identification of pairs of sequential alpha-decays, which are used to map fluid flow and ion drift in the liquid target. The resulting transport model is used to tag $^{214}$Pb beta-decays, a leading background to dark matter signals in LZ. Temporally evolving volume selections, at a cost of 9.0% of exposure, target the decay of each $^{214}$Pb atom up to 81 minutes after production, resulting in (63 $\pm$ 6$_{\mathrm{stat}}$ $\pm$ 7$_{\mathrm{sys}}$)% identification of $^{214}$Pb decays to ground state. We also demonstrate how flow-based tagging techniques enable a novel calibration side band that is concurrent with science data.

Aalbers, J. [SLAC; Stanford U., Phys. Dept.; KIPAC↗

Development of 17 N as a time-tagged neutron source for calibration of large antineutrino detectors

Large antineutrino detectors hold the potential for remote nuclear reactor monitoring and discovery, which is of great interest for nonproliferation and treaty verification applications. Correlated-particle calibration sources are especially useful for large-volume designs based on detection of inverse beta-decay events, as the timing information of the coincident particles improves background rejection and event reconstruction. 17 N is a promising calibration source since it emits beta-correlated delayed neutrons and can be produced relatively easily using high-energy neutrons. In this work, we examine the feasibility of 17 N as a time-tagged calibration source for large antineutrino detectors. 17 N was produced using a DT neutron generator from a water sample enriched in 17 O, and the observed production rates were found to be consistent with previous measurements of the 17 O(n,p) 17 N reaction cross-section. As a result, time-tagging of 17 N delayed neutrons is demonstrated via beta-neutron coincidence measurements conducted using a specialized beta detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Al-26 and circumstellar envelopes

The effects of the radioactive decay of Al-26 on the circumstellar envelopes of asymptotic giant branch stars are analyzed. The gamma-rays emitted by the product nucleus Mg-26 escape most envelopes, but the beta-decay positrons are stopped and can ionize and heat the gas. The ionization may produce observable effects in C-rich circumstellar envelopes, particularly if the photospheric Al-26 abundance is as large as inferred from measurements of live Al-26 in the primitive solar nebula or the observations of interstellar 1.8 MeV gamma-rays. For the nearby carbon star IRC +10216, the measured abundance of the molecular ion HCO(+) provides an upper limit of about 4 x 10(exp -3) for the photospheric Al-26/Al-27 ratio, consistent with presolar SiC grains with about the same C-12/C-13 ratio.

Glassgold, A. E.↗

Improving Fission Products at CARIBU: Near Field Detection (Q3/FY20 Quarterly Progress Report)

Following the report from last quarter where we reported the experimental procedures, data acquisition and filtering process for the beta decay of 156 Eu, in the past quarter we have worked on establishing the efficiency for detecting the radiation emitted from this isotope with simulations of the HPGe detector and we have started investigating the beta detector energy deposition spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methods of Fabricating Scintillators with Radioisotopes for Beta Battery Applications

Technology has been developed for a class of self-contained, long-duration power sources called beta batteries, which harvest the energy contained in the radioactive emissions from beta decay isotopes. The new battery is a significant improvement over the conventional phosphor/solar cell concept for converting this energy in three ways. First, the thin phosphor is replaced with a thick scintillator that is transparent to its own emissions. By using a scintillator sufficiently thick to completely stop all the beta particles, efficiency is greatly improved. Second, since the energy of the beta particles is absorbed in the scintillator, the semiconductor photodetector is shielded from radiation damage that presently limits the performance and lifetime of traditional phosphor converters. Finally, instead of a thin film of beta-emitting material, the isotopes are incorporated into the entire volume of the thick scintillator crystal allowing more activity to be included in the converter without self-absorption. There is no chemical difference between radioactive and stable strontium beta emitters such as Sr-90, so the beta emitter can be uniformly distributed throughout a strontium based scintillator crystal. When beta emitter material is applied as a foil or thin film to the surface of a solar cell or even to the surface of a scintillator, much of the radiation escapes due to the geometry, and some is absorbed within the layer itself, leading to inefficient harvesting of the energy. In contrast, if the emitting atoms are incorporated within the scintillator, the geometry allows for the capture and efficient conversion of the energy of particles emitted in any direction. Any gamma rays associated with secondary decays or Bremsstrahlung photons may also be absorbed within the scintillator, and converted to lower energy photons, which will in turn be captured by the photocell or photodiode. Some energy will be lost in this two-stage conversion process (high-energy particle to low-energy photons to electric current). The geometric advantage partially offsets this as well, since the absorption depth of high-energy beta radiation is much larger than the depth of a p-n junction. Thus, in a p-n junction device, much of the radiation is absorbed far away from the junction, and the electron- hole pairs are not all effectively collected. In contrast, with a transparent scintillator the radiation can be converted to light in a larger volume, and all of the light can be collected in the active region of the photodiode. Finally, the new device is more practical because it can be used at much higher power levels without unduly shortening its lifetime. While the crystal structure of scintillators is also subject to radiation damage, their performance is far more tolerant of defects than that of semiconductor junctions. This allows the scintillator- based approach to use both higher energy isotopes and larger quantities of the isotopes. It is projected that this technology has the potential to produce a radioisotope battery with up to twice the efficiency of presently used systems.

Rensing, Noa M.↗

Branching ratios for the three most intense gamma rays in the decay of 47 Ca

A sample of 47 Ca produced through isotope harvesting at the National Superconducting Cyclotron Laboratory was used to measure branching ratios of 7.17(5)%, 7.11(5)%, and 75.0(5)% for the 489.2, 807.9, and 1297.1 keV characteristic gamma rays, respectively. Based on these updated branching ratios, the ground state to ground state 47 Ca to 47 Sc beta decay branching ratio has been indirectly measured as 17.7(5)% and the ground state to 1297.1 keV excited state as 82.2(5)%. Here these values represent a greatly increased precision for all five branching ratios compared to the currently accepted values. The measurements presented here were made relative to the ingrown 47Sc daughter in a 47 Ca sample and the well-established 159.4 keV gamma-ray branching ratio and the half-life for the decay of 47 Sc. These measurements were supported by verifying that the half-lives measured from characteristic gamma-ray peaks over multiple spectra for both 47 Ca and 47 Sc were consistent with previously reported values. Additionally, the half-lives of both 47 Ca and 47 Sc were independently measured with Liquid Scintillation Counting to reverify the previously reported values used in this study to find updated gamma-ray branching ratio values.

07 ISOTOPE AND RADIATION SOURCES↗

Using cyclotron radiation emission for ultra-high resolution x-ray spectroscopy

Abstract Cyclotron radiation emission spectroscopy (CRES) is an approach to measuring the energy of an electron trapped in an externally applied magnetic field. The bare electron can come from different interactions, including photoelectric absorption, Compton scatters, beta decay, and pair production. CRES relies on measuring the frequency of the electron’s cyclotron motion, and because the measurement times extend over 10 6 –10 7 cycles, the energy resolution is on the order of a single electronvolt. To date, CRES has only been performed on internal beta-emitting radioisotopes, but the technology can be applied to x-ray spectrometery through appropriate selection of a target gas and sufficient intensity of the distinct x-ray source. The applications of this technology range from high-precision measurements of atomic energy levels to calibrations of basic science experiments, to trace element identification. In this work we explore the use of CRES for x-ray spectroscopy within the rubric of measuring the energy levels of argon. Though the energy levels of argon are well established, we adopt this motivation as an example question around which a detector may be designed. The issues we explore include target material, density, electron trapping depth, noise levels, and overall efficiency. We also discuss spectral deconvolution and how the multiple peaks obtained from a single target/source pair can be used to enhance the robustness of the measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Elemental technetium as a cosmic-ray clock

Several radioactive isotopes have been proposed as clocks for the study of the mean cosmic ray confinement time, T sub e. Measurements of Be-10 and Al-26 give a value for T sub e of about 10 Myr when one uses a leaky box cosmic ray propagation model. It is important to obtain additional measurements of T sub e from other radioactive isotopes in order to check whether the confinement is the same throughout the periodic table. The possible use of Tc (Z = 43) as a cosmic clock is investigated. Since all isotopes of Tc are radioactive, one might be able to group these isotopes and use the elemental abundance as a whole. The results of the calculations are somewhat inconclusive for two reasons. First, the beta + decay half lives of two of the Tc isotopes relevant to our calculation are not known. Second, the dependence of the Tc abundance on the mean confinement time is rather weak when one considers the number of events expected in 4 trays of plastic track detectors. However, a future, finite measurement of the Beta + half lives and the possible use of the entire collecting area of the HNC to detect Tc nuclei could make the use of Tc as a cosmic ray clock more attractive.

Drach, J.↗

Growth, optical, and luminescence characterization of LiCsMoO{sub 4} crystal.

A crack-free LiCsMoO4 crystal was grown with the conventional Czochralski technique. The optical properties of the crystal show it transparent well in the visible region. The luminescence properties of the crystal were studied from 300 to 14 K under the excitation with a 280 nm light-emitting diode (LED). At room temperature, the luminescence light yield is low; however, it increases significantly at low temperatures. The decay time of the crystal is measured under the excitation of the crystal with the 280 nm LED source. The decay times at all the temperatures are fitted with three exponential functions. The average decay time from 300 to 14 K varies from 6.7 to 8.6 mu s. A thermoluminescence (TL) study of the crystal was carried out from 9 to 300 K. Three TL peaks are found between 165 and 250 K. This study shows that the developed crystal has a potential application in search of neutrinoless double-beta decay of Mo-100 at cryogenic temperatures.

Conventional Czochralski technique↗

Nuclear Computational Low Energy Initiative (NUCLEI)

The NUCLEI project, as defined by the scope of work, developed, implemented and run codes for large-scale computations of many topics in low-energy nuclear physics. Physics studied include the properties of nuclei and nuclear decays, nuclear structure and reactions, and the properties of nuclear matter. The computational techniques used include Quantum Monte Carlo, Configuration Interaction, Coupled Cluster, and Density Functional methods. The research program emphasized areas of high interest to current and possible future DOE nuclear physics facilities, including ATLAS and FRIB (nuclear structure and reactions, and nuclear astrophysics), TJNAF (neutron distributions in nuclei, few body systems, and electroweak processes), NIF (thermonuclear reactions), MAJORANA and FNPB (neutrinoless double-beta decay and physics beyond the Standard Model), and LANSCE (fission studies).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/\mu}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/\mu}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$\pi$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Opportunities at the Sanford Underground Research Facility

The Sanford Underground Research Facility (SURF) has been operating for more than 15 years as an international facility dedicated to advancing compelling multidisciplinary underground scientific research in rare-process physics, as well as offering research opportunities in other disciplines. SURF laboratory facilities include a Surface Campus as well as campuses at the 4850-foot level (1490 m, 4300 m.w.e.) that host a range of significant physics experiments, including the LUX-ZEPLIN (LZ) dark matter experiment and the MAJORANA DEMONSTRATOR neutrinoless double-beta decay experiment. The CASPAR nuclear astrophysics accelerator completed the first phase of operation and is planning for the second phase beginning in 2024. SURF is also home to the Long-Baseline Neutrino Facility (LBNF) that will host the international Deep Underground Neutrino Experiment (DUNE). SURF offers world-class service, including an ultra-low background environment, low-background assay capabilities, and electroformed copper is produced at the facility. SURF is preparing to increase underground laboratory space. Plans are advancing for construction of new large caverns (nominally 100m L x 20m W x 24m H) on the 4850L (1485 m, 4100 mwe) on the timeframe of next-generation experiments (~2030). SURF plans to leverage existing advisory and community committees as well as engage the underground science community to inform plans for future laboratory space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗