Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Measurement and Analysis of Beam Phase-Space Distributions for the Fermilab Muon Campus Accelerator Complex

The Muon g-2 experiment at Fermilab is tasked with measuring the muon’s anomalous magnetic moment with high precision. Since the experiment requires large amounts of muons, it is imperative to systematically study the behavior of the beam along the transport line. Unfortunately, the available diagnostics only provide beam information in X-Y space. For a complete evaluation, information of the phase-space is required. This paper demonstrates a technique to measure the beam phase-direction distribution by using a set of beam profiles. First, we establish the theoretical framework that describes the principle of the technique. Next, we apply the technique at four different locations along the accelerator delivery line. Finally, we compare our findings to predictions from tracking simulations.

43 PARTICLE ACCELERATORS↗

Fabrication of large-area ultra-thin single crystal silicon membranes

Perfectly, crystalline, 55 nm thick silicon membranes have been fabricated over several square millimeters and used to observe transmission ion channeling patterns showing the early evolution of the axially channeled beam angular distribution for small tilts away from the [011] axis. The reduced multiple scattering through such thin layers allows fine angular structure produced by the highly non-equilibrium transverse momentum distribution of the channeled beam during its initial propagation in the crystal to be resolved. The membrane crystallinity and flatness were measured by using proton channeling measurements and the surface roughness of 0.4 nm using atomic force microscopy.

36 MATERIALS SCIENCE↗

Proton beam dynamics in bare IOTA with intense space-charge

We are commissioning a 2.5-MeV proton beam for the Integrable Optics Test Accelerator at Fermilab, allowing experiments in the strong space-charge regime with incoherent betatron tune shifts nearing 0.5. Accurate modelling of space-charge dynamics is vital for understanding planned experiments. We compare anticipated emittance growth and beam loss in the bare IOTA configuration using transverse space-charge models in Xsuite, PyORBIT, and MADX simulation codes. Our findings reveal agreement within a factor of 2 in core phase-space density predictions up to 100 synchrotron periods at moderate beam currents, while tail distributions and beam loss show significant differences.

43 PARTICLE ACCELERATORS↗

Proton Beam Dynamics in Bare IOTA with Intense Space-Charge

We are commissioning a 2.5~MeV proton beam for the Integrable Optics Test Accelerator at Fermilab, allowing experiments in the strong space-charge regime with incoherent betatron tune shifts nearing 0.5. Accurate modelling of space-charge dynamics is vital for understanding planned experiments. We compare anticipated emittance growth and beam loss in the bare IOTA configuration using transverse space-charge models in Xsuite, PyORBIT, and MAD-X simulation codes. Our findings reveal agreement within 30\% in core phase-space density predictions up to 100~synchrotron periods at moderate beam currents, while tail distributions and beam loss show significant differences.

43 PARTICLE ACCELERATORS↗

Laboratory observations of RF emission at plasma electron frequency and n + 1/2 times the electron cyclotron frequency in electron beam-plasma and beam-beam interactions

Electric field emissions at frequencies of (n + 1/2) times the electron cyclotron frequency have been generated in a large-scale electron beam experiment in a vacuum facility. These emissions arise when a contrastreaming beam configuration exists, the primary beam consisting of monoenergetic electrons (50 eV to 5 keV) and the other beam of lower-energy backscattered secondary electrons. It is suggested that the same mechanism could also be the source of the observed 3/2 times the electron cyclotron frequency emissions at auroral latitudes. In the absence of the beam-beam instability, weak oscillations were observed at the plasma frequency. In the latter case no significant modifications of the primary beam velocity distribution occurred, and the beam configuration is adequately described by single-particle motion in the ambient magnetic field.

Bernstein, W.↗

Equilibrium Tail Distribution Due to Touschek Scattering

Single large angle Coulomb scattering is referred to as Touschek scattering. In addition to causing particle loss when the scattered particles are outside the momentum aperture, the process also results in a non-Gaussian tail, which is an equilibrium between the Touschek scattering and radiation damping. Here we present an analytical calculation for this equilibrium distribution.

99 GENERAL AND MISCELLANEOUS↗

Magnitude of Residual Internal Anatomy Motion on Heavy Charged Particle Dose Distribution in Respiratory Gated Lung Therapy

Purpose: To assess the variation in carbon beam dose distribution due to residual motion in lung cancer patients undergoing respiratory-gated radiotherapy. Methods and Materials: A total of 11 lung cancer patients underwent four-dimensional computed tomography with a 256-multislice computed tomography scanner under free-breathing conditions. A compensating bolus was designed to cover the treatment beam for all planning target volumes during a 30% duty cycle centered on exhalation (gating window). This bolus was applied to the four-dimensional computed tomography data for one respiratory cycle, and then the carbon beam dose distribution was calculated. Results: A water equivalent pathlength variation of <5 mm was observed in the gating window, but this increased to {<=}20 mm on inhalation. As a result, beam overshoot/undershoot occurred around inhalation, which increased the excessive dosing to normal tissues and the organs at risk. The dose for >95% volume irradiation is dependent on the respiratory phase but not the gating window. However, the dose for >95% volume irradiation correlated well with the tumor displacement distance. More than 90% of the dose for >95% volume irradiation could be delivered in the gating window with <4-mm tumor displacement resulting from exhalation. Conclusion: The results of our study have shown that even when the treatment beam delivery occurs outside the gating window, the prescribed dose to the target is not affected in patients with a tumor displacement of <4 mm. Thus, respiratory gating is not required in radiotherapy for patients with <4-mm tumor displacement in a respiratory cycle.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of activity pencil beam algorithm using measured distribution data of positron emitter nuclei generated by proton irradiation of targets containing {sup 12}C, {sup 16}O, and {sup 40}Ca nuclei in preparation of clinical application

Purpose: The purpose of this study is to develop a new calculation algorithm that is satisfactory in terms of the requirements for both accuracy and calculation time for a simulation of imaging of the proton-irradiated volume in a patient body in clinical proton therapy. Methods: The activity pencil beam algorithm (APB algorithm), which is a new technique to apply the pencil beam algorithm generally used for proton dose calculations in proton therapy to the calculation of activity distributions, was developed as a calculation algorithm of the activity distributions formed by positron emitter nuclei generated from target nuclear fragment reactions. In the APB algorithm, activity distributions are calculated using an activity pencil beam kernel. In addition, the activity pencil beam kernel is constructed using measured activity distributions in the depth direction and calculations in the lateral direction. {sup 12}C, {sup 16}O, and {sup 40}Ca nuclei were determined as the major target nuclei that constitute a human body that are of relevance for calculation of activity distributions. In this study, ''virtual positron emitter nuclei'' was defined as the integral yield of various positron emitter nuclei generated from each target nucleus by target nuclear fragment reactions with irradiated proton beam. Compounds, namely, polyethylene, water (including some gelatin) and calcium oxide, which contain plenty of the target nuclei, were irradiated using a proton beam. In addition, depth activity distributions of virtual positron emitter nuclei generated in each compound from target nuclear fragment reactions were measured using a beam ON-LINE PET system mounted a rotating gantry port (BOLPs-RGp). The measured activity distributions depend on depth or, in other words, energy. The irradiated proton beam energies were 138, 179, and 223 MeV, and measurement time was about 5 h until the measured activity reached the background level. Furthermore, the activity pencil beam data were made using the activity pencil beam kernel, which was composed of the measured depth data and the lateral data including multiple Coulomb scattering approximated by the Gaussian function, and were used for calculating activity distributions. Results: The data of measured depth activity distributions for every target nucleus by proton beam energy were obtained using BOLPs-RGp. The form of the depth activity distribution was verified, and the data were made in consideration of the time-dependent change of the form. Time dependence of an activity distribution form could be represented by two half-lives. Gaussian form of the lateral distribution of the activity pencil beam kernel was decided by the effect of multiple Coulomb scattering. Thus, the data of activity pencil beam involving time dependence could be obtained in this study. Conclusions: The simulation of imaging of the proton-irradiated volume in a patient body using target nuclear fragment reactions was feasible with the developed APB algorithm taking time dependence into account. With the use of the APB algorithm, it was suggested that a system of simulation of activity distributions that has levels of both accuracy and calculation time appropriate for clinical use can be constructed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Third-Order Distributed Feedback Laser with Enhanced Beam Pattern

A third-order distributed feedback laser has an active medium disposed on a substrate as a linear array of segments having a series of periodically spaced interstices therebetween and a first conductive layer disposed on a surface of the active medium on each of the segments and along a strip from each of the segments to a conductive electrical contact pad for application of current along a path including the active medium. Upon application of a current through the active medium, the active medium functions as an optical waveguide, and there is established an alternating electric field, at a THz frequency, both in the active medium and emerging from the interstices. Spacing of adjacent segments is approximately half of a wavelength of the THz frequency in free space or an odd integral multiple thereof, so that the linear array has a coherence length greater than the length of the linear array.

Hu, Qing↗

Design and Analysis of a Halo-Measurement Diagnostics

A large dynamical-range diagnostics (LDRD) design at Jefferson Lab will be used at the FAST-IOTA injector to measure the transverse distribution of halo associated with a high-charge electron beam. One important aspect of this work is to explore the halo distribution when the beam has significant angular momentum (i.e. is magnetized). The beam distribution is measured by recording radiation produced as the beam impinges a YAG:Ce screen. The optical radiation is split with a fraction directed to a charged-couple device (CCD) camera. The other part of the radiation is reflected by a digital micromirror device (DMD) that masks the core of the beam distribution. Combining the images recorded by the two cameras provides a measurement of the transverse distribution with over a large dynamical range. The design and analysis of the optical system will be discussed including optical simulation using SRW and the result of a mockup experiment to test the performances of the system will be presented.

43 PARTICLE ACCELERATORS↗

SU-E-T-441: Comparison of Dose Distributions for Spot-Scanned Pencil-Beam and Scattered-Beam Proton Treatments of Ocular Tumors

Purpose: To study the cross-field and depth dose profiles of spot-scanned pencil beam configurations for the treatment of ocular tumors and to compare their performance to a simulated scattered beam. Methods: Dose distributions in a cubic water phantom were compared for beams that passed through a final 24mm diameter aperture to deposit maximum dose at 2.4cm depth. The pencil-beam spots formed a hexagonally-packed ring with a center-to-center spacing of 4mm. The protons exited the nozzle with energy 95.5MeV, traversed a 4.5cm water-equivalent range shifter, and travelled either 42.5cm or 100cm to the phantom surface. The aperture-to-phantom distance (APD) was 5.7cm to allow room for eye-tracking hardware. A configuration with APD=0 was also tested. The scattered beam was generated with energy 159MeV, passed through 127mm of Lexan, exited the final aperture, and travelled 5.7cm to the phantom surface. This latter configuration is comparable to the MGH single scattered beamline. All beams were modelled with TOPAS1.0-beta6 compiled with GEANT4.9.6p2. Results: The modeled scattered beam produced a distal fall-off along the central axis of zd90%-zd10%=3.6mm. For the pencil beam, the zd90%-zd10% was 1.6mm in all configurations. The scattered beam's cross-field penumbra at depth of maximum dose was r90%- r10%=1.9mm. For the spot-scanned configuration with the range-shifter-tophantom distance (RsPD) of 100cm, similar cross-field profiles were achieved with r90%-r10%=2.0mm. At shorter RsPD of 42.5cm, the crossfield penumbras were 5.6mm and 7.7mm for APD=0cm and APD=5.7cm, respectively. Conclusion: For proton treatments employing a range shifter, the cross-field and central axis dose profiles depend on the quality of the original beam, the size of the range shifter, the distance from the range shifter exit to the patient, and the distance from the final aperture to the patient. A spot-scanned pencil beam configuration can achieve cross-field penumbras equal to a scattered beam and superior distal gradients.

60 APPLIED LIFE SCIENCES↗

Dynamics of modulated beams in spectral domain

General formalism for describing dynamics of modulated beams along linear beamlines is developed. We describe modulated beams with spectral distribution function which represents Fourier transform of the conventional beam distribution function in the 6-dimensional phase space. The introduced spectral distribution function is localized in some region of the spectral domain for nearly monochromatic modulations. It can be characterized with a small number of typical parameters such as the lowest order moments of the spectral distribution. We study evolution of the modulated beams in linear beamlines and find that characteristic spectral parameters transform linearly. The developed approach significantly simplifies analysis of various schemes proposed for seeding X-ray free electron lasers. We use this approach to study several recently proposed schemes and find the bandwidth of the output bunching in each case.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of laser prepulse on proton generation: active manipulation of the distribution of laser accelerated proton beams

Laser pre-pulse is a major issue in experiments on laser-generation of protons, often limiting the performances of laser sources. In this paper, we show how we can actively use a low intensity prepulse (<10{sup 13} W/cm{sup 2}, ns duration) to manipulate the proton beam direction or spatial energy distribution. The prepulse is focused onto the front surface of a thin foil before the arrival of the high intensity pulse ({approx_equal}10{sup 19} W/cm{sup 2}, ps duration). Under oblique high-intensity irradiation and for low prepulse intensities, the proton beam is directed away from the target normal. Deviation is towards the laser forward direction, with an angle that increases with the level and duration of the ASE pedestal. Also, for a given laser pulse, beam deviation increases with proton energy. The observations are discussed in terms of Target Normal Sheath Acceleration, in combination with a laser-controllable shock wave locally deforming the target surface. Results obtained with an annular intensity distribution of the prepulse show smooth proton beams with a sharp circular boundary at all energies. Potential mechanisms to explain the observations are discussed.

43 PARTICLE ACCELERATORS↗

Modeling of Dose Distribution for a Proton Beam Delivering System with the use of the Multi-Particle Transport Code 'Fluka'

We have developed a new delivering system for hadron therapy which uses a multileaf collimator and a range shifter. We simulate our delivering beam system with the multi-particle transport code 'Fluka'. From these simulations we obtained information about the dose distributions, about stars generated in the delivering system elements and also information about the neutron flux. All the informations obtained were analyzed from the point of view of radiation protection, homogeneity of beam delivery to patient body, and also in order to improve some modifiers used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Absolute and relative dosimetry for ELIMED

The definition of detectors, methods and procedures for the absolute and relative dosimetry of laser-driven proton beams is a crucial step toward the clinical use of this new kind of beams. Hence, one of the ELIMED task, will be the definition of procedures aiming to obtain an absolute dose measure at the end of the transport beamline with an accuracy as close as possible to the one required for clinical applications (i.e. of the order of 5% or less). Relative dosimetry procedures must be established, as well: they are necessary in order to determine and verify the beam dose distributions and to monitor the beam fluence and the energetic spectra during irradiations. Radiochromic films, CR39, Faraday Cup, Secondary Emission Monitor (SEM) and transmission ionization chamber will be considered, designed and studied in order to perform a fully dosimetric characterization of the ELIMED proton beam.

43 PARTICLE ACCELERATORS↗