Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Energy Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Advancements on Multi-Fidelity Random Fourier Neural Networks: Application to Hurricane Modeling for Wind Energy

Multi-fidelity approaches are emerging as effective strategies in computational science to handle otherwise intractable tasks like Uncertainty Quantification (UQ), training of Machine Learning (ML) models, and optimization, for expensive high-fidelity applications in which the amount of available simulations or data is limited. The main idea is simple: large datasets generated for low-fidelity approximations of the problem at hand are fused with a much sparser dataset for the target (high-fidelity) system. In this paper, we build on our recent success in designing random Fourier Neural Networks (rFNNs) [1] to target problems arising in wind energy applications and in particular problems of interest for hurricane modeling. In this context, data for the high-fidelity models are limited and lower fidelity alternatives are needed. In this work, we introduce a novel multi-fidelity training approach for our rFNNs and demonstrate its use on a simple verification problem and on a hurricane modeling problem in which high-fidelity data are generated via Large-Eddy Simulations (LES), while low-fidelity data are given by a mesoscale model. Initial results demonstrate how the multi-fidelity training approach can improve the quality of the resulting surrogate.

Fourier Neural Networks↗

Sienna Modeling Framework [Slides]

NREL's Sienna modeling framework effectively builds, solves, and analyzes the scheduling problems and dynamic simulations of quasi-static infrastructure systems. It uses a modular framework to answer different questions about future energy systems, fundamentally advancing the nation's ability to model individual and integrated infrastructure systems at a range of spatial and temporal scales. This presentation will include NREL power grid researcher Clayton Barrows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

Robust anomaly detection for particle physics using multi-background representation learning

Abstract Anomaly, or out-of-distribution, detection is a promising tool for aiding discoveries of new particles or processes in particle physics. In this work, we identify and address two overlooked opportunities to improve anomaly detection (AD) for high-energy physics. First, rather than train a generative model on the single most dominant background process, we build detection algorithms using representation learning from multiple background types, thus taking advantage of more information to improve estimation of what is relevant for detection. Second, we generalize decorrelation to the multi-background setting, thus directly enforcing a more complete definition of robustness for AD. We demonstrate the benefit of the proposed robust multi-background AD algorithms on a high-dimensional dataset of particle decays at the Large Hadron Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

End-Use Savings Shapes Measure Documentation: Advanced Rooftop Unit Control

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. Advanced rooftop unit controls (ARC) generally consist of a supply fan VFD, and controls to implement demand controlled ventilation (DCV) and air-side economizing, as a retrofit to improve energy efficiency of existing rooftop units (RTUs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Rooftop Solar Potential in Chernihiv and Lviv, Ukraine, and Efficacy of High-Resolution 3D Data Digital Twins [Slides]

NREL evaluated rooftop solar photovoltaic (PV) siting opportunities in the cities of Chernihiv and Lviv, Ukraine, leveraging very-high-resolution 3D elevation data to calculate technical potential. The study assessed total rooftop solar capacity and annual energy production. In Chernihiv and Lviv, 116,503 buildings were analyzed for their rooftop solar potential. The buildings in the study areas include a mixture of residential, commercial, and industrial buildings, characterized by diverse roof shapes and sizes. The total estimated rooftop solar capacity is 332 MWDC in Chernihiv and 873 MWDC in Lviv with annual energy production up to 376.2 GWhDC in Chernihiv and 995.5 GWhDC in Lviv. This accounting provides a clear estimate of the potential rooftop solar installations that could be realized under optimal conditions, considering both technical constraints and the geographic distribution of available rooftop space. Related to Russia's invasion of Ukraine, NREL estimates loss from buildings damaged or destroyed of 2,754 buildings, 20.15 MWDC of capacity, and 22,869 MWhDC of annual energy production in Chernihiv as well as a loss of 1,316 buildings, 34.49 MWDC of capacity, and 39,369 MWhDC of annual energy production in Lviv. The study also assessed the feasibility of adapting this methodology on a national scale using either simulated digital surface models (DSMs) or a digital twin approach. While the very-high-resolution DSM provided more precise results, the simulated DSM demonstrated reasonable accuracy for broader applications in modeling aggregated distributed solar supply. The feasibility of using a digital twin for Ukraine's national rooftop solar potential is considered promising, with certain limitations in areas with highly variable building stock and heavy war damage.

14 SOLAR ENERGY↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Los Angeles 100% Clean Energy Equity Strategies

The National Renewable Energy Laboratory and Los Angeles Department of Water and Power set out to identify strategies to improve equity in LA's transition to 100% clean energy. Through social science research, NREL summarized underserved community member challenges and solutions from listening sessions and community-based organizations. NREL modeled future scenarios for solar, transportation electrification, rates, building technologies, and the distribution grid to identify strategies that improved community-prioritized equity metrics. Findings provide specific strategies relevant for LA and elsewhere to improve equity and affordability in achieving 100% clean energy.

100% clean energy↗

Solidification and crystallographic texture modeling of laser powder bed fusion Ti-6Al-4V using finite difference-monte carlo method

Laser powder bed fusion (LPBF) additive manufacturing makes near-net-shaped parts with reduced material cost and time, rising as a promising technology to fabricate Ti-6Al-4V, a widely used titanium alloy in aerospace and medical industries. However, LPBF Ti-6Al-4V parts produced with 67° rotation between layers, a scan strategy commonly used to reduce microstructure and property inhomogeneity, have varying grain morphologies and weak crystallographic textures that change depending on processing parameters. Here, this study predicts LPBF Ti-6Al-4V solidification at three energy levels using a finite difference-Monte Carlo method and validates the simulations with large-area electron backscatter diffraction (EBSD) scans. The developed model accurately shows that a <001> texture forms at low energy and a <111> texture occurs at higher energies parallel to the build direction but with a lower strength than the textures observed from EBSD. A validated and well-established method of combining spatial correlation and general spherical harmonics representation of texture is developed to calculate a difference score between simulations and experiments. The quantitative comparison enables effective fine-tuning of nucleation density (N 0 ) input, which shows a nonlinear relationship with increasing energy level. Future improvements in texture prediction code and a more comprehensive study of N 0 with different energy levels will further advance the optimization of LPBF Ti-6Al-4V components. These developments contribute a novel understanding of crystallographic texture formation in LPBF Ti-6Al-4V, the development of robust model validation and calibration pipeline methodologies, and provide a platform for mechanical property prediction and process parameter optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

U.S. Department of Energy Solar District Cup Collegiate Design Competition

The Solar District Cup is a multidisciplinary collegiate competition that challenges student teams to design and model standalone solar and solar-plus-storage systems for multiple buildings on a local electrical distribution network, such as a college campus, across a development, or in a district. Students learn cross-cutting skills that prepare them to become part of the next generation of the distributed energy workforce. Student teams act as renewable energy developers proposing to solar and solar-plus-storage system requests. Students, faculty, and prospective employers can benefit from knowing about this program and what students learn--either immediately as participants, mentors, or judges, or as potential employers of Solar District Cup alumni. RE+ is also one of our competition partners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ELM‐MOSART‐DOC: A Large‐Scale Riverine Dissolved Organic Carbon Model and Its Application Over the United States

Riverine dissolved organic carbon (DOC), primarily sourced from soil organic carbon (SOC), plays a crucial role in regional and global carbon cycles. However, the complexities of the underlying mechanisms and limited observations present significant challenges for predictive understanding of DOC at regional or larger scales. Recently, we developed a machine learning‐based (ML) map of DOC transformation rates, bridging the gap between SOC and DOC leaching flux and simplifying terrestrial DOC representation. Building on this advancement, we introduce ELM‐MOSART‐DOC, a DOC module integrated into the riverine component of the Energy Exascale Earth System Model (E3SM)—the Model for Scale Adaptive River Transport (MOSART). ELM‐MOSART‐DOC simulates DOC transport and transformation across both headwater streams and river networks, including those managed. Model validation demonstrates the ability of ELM‐MOSART‐DOC to accurately capture long‐term average DOC concentrations, with Kling‐Gupta Efficiency (KGE) scores of 0.58 and 0.76 at large and local stations, respectively. We further assess the impact of reservoirs through different simulation schemes, revealing that reservoirs significantly alter DOC fluxes by regulating streamflow patterns and promoting DOC mineralization. Model simulations indicate that reservoirs reduce total DOC flux from the Mississippi River into the ocean by 7.5%, with the long‐term average annual export decreasing from 3.34 to 3.14 teragrams (Tg) per year. ELM‐MOSART‐DOC integrates process‐based modeling with ML parameterization to enhance the predictive understanding of riverine biogeochemical processes. This approach reduces uncertainties in modeling regional and global carbon cycle ESMs and provides new insights into carbon cycling and its implications for global environmental change.

Li, Lingbo [Univ. of Houston, TX (United States); ↗

Design Basis Model for Hosting Small Modular Reactors

An aggressive transition from fossil fuels to other types of energy implies the need to construct a large number of nuclear power plants in the near future. However, the real and perceived risks of nuclear energy remain a significant impediment to this transition. This paper describes a comprehensive work process that combines the rigor of model-based systems engineering (MBSE) with 1) the Idaho National Laboratory's (INL) decades of experience with small reactors and with 2) modern project delivery processes. The objective is to reduce the risk of building new facilities or converting existing facilities to nuclear power generation.

42 ENGINEERING↗

IoT-based retrofit information diffusion in future smart communities

Community-scale building retrofits are not merely scaled-up versions of single-building retrofits. They involve complex challenges, such as reconciling individual interests with collective goals and managing the dynamic interplay between buildings through mechanisms like power grids and social connections. Internet of Things (IoT) connectivity holds the potential to leverage these interplays to balance individual and collective interests effectively in smart communities. One critical aspect of this interplay is information diffusion, which shapes how retrofit decisions spread among neighbors, influencing individual choices and ultimately impacting community-level retrofit outcomes. In other words, IoT-based smart devices automatically push tailored retrofit notifications to homeowners, which completely changes the format of information diffusion in the future. To investigate this influence by such information diffusion, the study used CityBES to simulate energy performance for different retrofits and applied an information diffusion model to analyze how decisions spread in a networked community of 192 buildings. The diffusion process was modeled on a weighted, directed network, capturing the dynamics of information flow and decision-making across 16 scenarios. Individual retrofit benefits were evaluated through payback years, while community-level retrofit outcomes were assessed using greenhouse gas (GHG) emission reductions. The results demonstrate that easier information diffusion among neighbors encourages households to prioritize retrofit measures that align with the majority’s optimal choices, even at the expense of individual financial benefits. In this case, such collective prioritization enhanced community-level retrofit performance, increasing GHG emission reductions by up to 29.4 %. However, this improvement came with trade-offs, as the average payback period for households extended by approximately 1.74 years. These findings highlight the potential of IoT-based information diffusion in future smart communities to coordinate individual interests with collective goals, ultimately accelerating community-level building retrofits.

Shu, Lei↗

How Heat Pumps Can Bring Relief to Households

An estimated 230,000 low-income households in Los Angeles lack access to cooling and are projected to experience more than two months of dangerous indoor temperatures (above 86 F) by 2035. Multifamily building residents are at much higher risk of dangerous heat exposure. Through robust modeling and analysis in the LA100 Equity Strategies project, the National Renewable Energy Laboratory (NREL) identified strategies that could save lives and maintain safe home temperatures for low-income households during heat waves, including the installation of whole-home heat pumps.

buildings↗

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2023

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process relying on the Capital Asset Pricing Model (CAPM) to estimate a business’ cost of equity, and by adding a risk adjustment factor to the risk-free rate associated with long-term U.S. Treasury bonds to estimate their cost of debt. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: • Discount rate estimation methods and rationale • Data sources used and data limitations • Discount rate distributions for use in standards analysis • Discount rate estimation methods and distributions specific to the small business subgroup analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗