Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Heating Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

Performance study of a novel dew point evaporative cooler in the climate of central Europe using building simulation tools

This paper presents the performance research of a hybrid air conditioning system (System II) equipped with novel dew point evaporative cooler (DPIEC) for a retail building located in temperate climatic conditions. The new cooler has a dedicated, adaptable structure that maximizes its performance in the climate conditions of central Europe. The unit can operate as a typical regenerative air cooler when outdoor air is drier than indoor air, it can operate as a counter-flow heat recovery unit when indoor conditions are more dry than outdoor and it can operate as a combination of both arrangements. The year-round, hourly-stepped building energy simulations were carried-out using a prognostic tool of energy consumption. The novel dew point evaporative cooler application potential was established using the black-box model based on regression equations was established based on experimental tests on a prototype of novel DPIEC. The hybrid system operation was compared to the typical air handling unit equipped with a standard energy wheel for heat recovery (System I). Presented research shows that DPIEC can cover about 95% of total cooling loads while the energy wheel covers only 9% of total cooling load. System II allows us to save 65% of seasonal electricity consumption comparing to System I. It comes from the fact that during most of the cooling season DPIEC is in operation and it covers most of the cooling loads without the need to switch the chilled water system.

Air conditioning↗

Grid Value Analysis of Geothermal Systems for End-Use Applications

Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.

decarbonization↗

COGIHTO: Comprehensive Geothermal Integrated HVAC Retrofits in Disadvantaged Communities

Geothermal heating and cooling (GHC) systems offer one of the most efficient approaches to provide space conditioning and water heating in buildings. Due to the relatively stable temperature of the ground year-round, these systems can provide an efficient solution to decarbonize heating systems. Yet this technology has faced limited market adoption due to its high first cost. This project seeks to address this barrier by designing a community GHC system at a public housing development in New York, taking advantage of load diversity (in terms of the timing and amount of heating / cooling used per person) that a larger community offers to reduce the size and thus first cost of a GHC system. Project success would result in societal benefit from reduced energy and fossil fuel use, reduced local emissions, and improved comfort, which would positively impact the health and well-being this community. This report presents the findings from Phase 1 project supported by the Department of Energy’s Geothermal Technologies Office and includes the technical design of a GHC at a public housing development in New York. To support the success of a potential deployment of a GHC system, the team conducted community engagement and prepared an assessment of the local workforce needs. The project team, led by EPRI, considered a subset of NYCHA housing developments that were previously identified by NYCHA as suitable for GHC retrofits. This report presents the site selection criteria the team developed and the overall score assigned to each of the eight developments considered. One site was selected for focus of the technical design: Stapleton Houses in Staten Island, a mid-size development with roughly 700 apartments across 6 buildings. The site has an existing hot water hydronic loop served by natural gas boilers for space heating and water heating. The technical design partner assessed baseline energy consumption at the site and established thermal models of the apartment buildings to assist in the design. The team considered several GHC system configurations and selected a hybrid geothermal design fed from water-source heat pumps with auxiliary gas boilers in a central plant. This design best leveraged the existing site configuration and minimized costs due to additional electrical infrastructure upgrades. The report also details the feedback received from community engagement efforts and the findings from the workforce needs assessment and workforce transition plan. Members of the site maintenance staff and the resident advisory council were interviewed for their input and feedback about both the site’s existing heating/cooling infrastructure and how a construction project would impact resident life. This feedback was taken into consideration when completing the geothermal system design. Research was conducted into existing workforce development opportunities available to NYCHA residents. A workforce development plan was established using information from NYCHA’s resident economic empowerment and sustainability group, along with training material and curriculum from the International Ground Source Heat Pump Association (IGSHPA).

15 GEOTHERMAL ENERGY↗

Parametric study of solid-solid translucent phase change materials in building windows

Thermal energy storage and solar radiation management are crucial to improve the sustainability and energy efficiency of buildings. Compared with the implementation of phase change materials (PCMs) in opaque components, the energy saving potential of incorporating PCMs in transparent glazing windows is much less studied and not well understood. Here we present a comprehensive parametric study of novel PCM windows for building energy saving with a focus on optimizing and quantitatively distinguishing the contributions from the optical and thermal properties of the PCM, which is particularly useful for the design of solid-solid PCM windows. We investigate a reference commercial office building using EnergyPlus by developing an equivalent model of our PCM window that is compatible with EnergyPlus's modeling capabilities. Compared with a clear-clear double-pane window, the integration of 3 mm solid-solid PCMs with optimal properties in warm, mixed, and cold climates can respectively save up to 17.2%, 14.0%, and 5.8% energy for the HVAC (heating, ventilation, and air conditioning) system, and 9.4%, 6.7%, and 3.2% energy for the whole building. We also demonstrate that these energy savings are most sensitive to the solar absorptance of PCMs for all three climates. The optimal transition temperature varies with climate and is related to the climate and solar radiation heat gain. Other issues are also briefly discussed, such as hysteresis, window orientations, and the effect of interior lighting. Finally, although the optimal PCM windows show energy saving performance comparable with low-emissivity windows, the PCM windows provide a unique advantage in terms of shifting HVAC loads which can provide benefits to the electrical grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

In cooperation with the Building America Program, The Levy Partnership explored a variety of options to reduce space-conditioning energy consumption, working with partners to design, manu- facture, and build test homes in three states. The Levy Partnership tested the use of minisplit ductless heat pumps in combi- nation with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The team set out to achieve 50% less energy consumption, compared to the 2009 International Energy Conservation Code, while maintaining home afford- ability and thermal comfort. The strategy also included a highly efficient thermal envelope to reduce space-conditioning loads.

30 DIRECT ENERGY CONVERSION↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

Experimental study on a novel three-phase absorption thermal battery with high energy density applied to buildings

Buildings contribute to 75% of total electricity consumption and 80% of peak electricity demand in the United States. A significant portion of building electricity consumption goes to space conditioning. Therefore, using thermal energy storage (TES) to decouple the building electricity consumption and the fluctuating space-conditioning load has significant potential to shift peak electricity demand and improve the stability of the grid. To provide effective TES within the spatial constraints in buildings, a three-phase absorption thermal battery (TATB) system with very high energy storage density was designed and studied. The TATB stores low-temperature heat in hydrate crystals of salts and supports space conditioning through absorption systems. In this study, a benchtop TATB using lithium chloride (LiCl) hydrate crystals as the storage material was tested under practical operating conditions for its energy storage density and discharge rate. We report the TATB successfully generated LiCl hydrate crystals during charging mode and then dissolved the crystals during discharging mode. A material-based energy storage density of 300 kWh/m 3 (specific energy of 903 kJ/kg) was achieved with a discharge rate of up to 1.3 kW thermal energy. The test results verified the high performance of the TATB and encouraged further development of this technology.

25 ENERGY STORAGE↗

Understanding detachment of the W7-X island divertor

The fundamental behavior of the W7-X island divertor under detached conditions, which has been theoretically predicted with the EMC3-Eirene code, is re-examined here under the experimental conditions achieved so far and compared with the first experimental results. Both simulations and experiments cover a range of divertor configurations and plasma parameters, and show the following common trends: (1) with rising impurity radiation, the target heat load decreases 'uniformly' over the entire target surface in the sense that both the peak and average heat loads can drop by an order of magnitude. Impurity radiation (mainly from intrinsic carbon) occurs primarily at the plasma edge and the resulting negative impact on the stored energy is less than 10%. (2) When the total radiation exceeds a critical level, the target particle flux (the recycling flux Γrecy) begins to fall and can drop by a factor of 3–5 at high radiation levels without an obvious indication of significant volume recombination. (3) While Γ recy decreases, the divertor neutral pressure continues to build up and reaches a maximum, at which point Γ recy has declined significantly. (4) During detachment, the electron temperature at the last closed flux surface falls in a way that is not quantitatively understandable from parallel classical heat conduction processes. This paper presents a physical explanation of the numerical/experimental results described above. Furthermore, using the EMC3-Eirene code as a diagnostic tool, we are able, apparently for the first time, to provide a full quantitative analysis of each transport channel in the island divertor, aiming to clarify how the island divertor plasma self-regulates to maintain particle, energy, and momentum balance under detached conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plutonium-238 Loadout Calorimeter Return To Service

The calorimeter in the transfer area in Building 7920 at the US Department of Energy’s Oak Ridge National Laboratory is used to measure the amount of 238 Pu in the Plutonium Heat Source Oxide. The calorimetry measurement is taken after the oxide is packaged in an ORISC (Oak Ridge Inner Shipping Capsule)/FSO (Fuel Storage Outer) assembly before loading into the Containment Vessel and shipping container. The equipment is used in three specific configurations: zero measurement (nothing in the sample cup), FSO measurement (actual measurement of 238 Pu), and reference calibration measurement (using the reference FSO as a known heat source). System checks were performed in July 2023 in preparation for scheduled material loadout. During these checks, personnel discovered that the reference FSO had experienced an electrical short in the heater cable and was no longer functional. The calorimeter was in the reference calibration measurement configuration at this time. Facility management was notified when the damage was discovered. The data from the Yokogawa recorder were pulled and analyzed for a span of time between September 2022 and July 2023. An unusual spike was found in the sample cup temperature data that started on October 19, 2022, and ended on October 20, 2022. The sample cup reached a temperature of 191.1°C. The maximum allowable temperature for the calorimeter thermopile to reach is 220°C based on the manufacturer statement provided in Appendix B of this report [1]. The calorimeter thermopile and the sample cup thermocouple are physically close to each other; therefore, the data suggest that the calorimeter itself never saw a temperature in excess of 191.1°C. Physical damage present on the cable, tape, and insulation suggests that the temperature reached a higher value in some locations within the sample cup than the data shows. Because of this discrepancy, testing of the calorimeter was required to confirm that the calorimeter is functioning the same as it was before the electrical short. The intent of this report is to assess the functionality of the calorimeter and determine if it is acceptable to use for 238 Pu loadout material measurement. Testing showed that the calorimeter is functionally equivalent to the initial calibration that was performed in the summer of 2021, and thus, the calorimeter was cleared to be used for its intended purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pushing the Envelope-Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream: Preprint

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

anisotropic envelope↗

Pushing the Envelope—Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

Shrestha, Som↗

Dynamic Thermal Performance Analysis of PCM Products Used for Energy Efficiency and Internal Climate Control in Buildings

PCMs are attractive for the future generation of buildings, where energy efficiency targets and thermal comfort expectations are increasingly prioritized. Experimental analysis of local thermal processes in these dynamic components and whole-building energy consumption predictions are essential for the proper implementation of PCMs in buildings. This paper discusses the experimental analysis of the thermophysical characteristics of both a latent heat storage material (PCM) and a product containing this PCM. The prototype product under investigation is a panelized PCM technology containing inorganic, salt-hydrate-based PCM. The thermal analysis includes studies of melting and freezing temperatures, enthalpy changes during phase change processes, nucleation intensity, sub-cooling effects, and PCM stability. The PCM’s stability is also investigated, as is the ability of PCM products to control local temperatures and peak load transmission times. Two inorganic PCM formulations based on calcium chloride hexahydrate (CaCl 2 .6H 2 O) were prepared and tested in laboratory conditions. Material-scale testing results were compared with outcomes from the system-scale analysis, using both laboratory test methods as well as field exposure in test huts. This work demonstrates that PCM technologies used in buildings can effectively control both the magnitude of thermal storage capacity as well as the time of the peak thermal load. It was found that commonly used material-scale testing methods may not always be beneficial in assessing the dynamic thermal performance characteristics of building technologies containing PCMs.

42 ENGINEERING↗

CityLearn v2: energy-flexible, resilient, occupant-centric, and carbon-aware management of grid-interactive communities

As more distributed energy resources become part of the demand-side infrastructure, quantifying their energy flexibility on a community scale is crucial. CityLearn v1 provided an environment for benchmarking control algorithms. However, there is no standardized environment utilizing realistic building-stock datasets for distributed energy resource control benchmarking without co-simulation or third-party frameworks. CityLearn v2 extends CityLearn v1 by providing a stand-alone simulation environment that leverages the End-Use Load Profiles for the U.S. Building Stock dataset to create grid-interactive communities for resilient, multi-agent, and objective control of distributed energy resources with dynamic occupant feedback. While the v1 environment used pre-simulated building thermal loads, the v2 environment uses data-driven thermal dynamics and eliminates the need for co-simulation with building energy performance software. This work details the v2 environment and provides application examples that use reinforcement learning control to manage battery energy storage system, vehicle-to-grid control, and thermal comfort during heat pump power modulation.

Nweye, Kingsley↗

Evaluation of low-exergy heating and cooling systems and topology optimization for deep energy savings at the urban district level

District energy systems have the potential to achieve deep energy savings by leveraging the density and diversity of loads in urban districts. However, planning and adoption of district thermal energy systems is hindered by the analytical burden and high infrastructure costs. It is hypothesized that network topology optimization would enable wider adoption of advanced (ambient temperature) district thermal energy systems, resulting in energy savings. In this study, energy modeling is used to compare the energy performance of “conventional” and “advanced” district thermal energy systems at the urban district level, and a partial exhaustive search is used to evaluate a heuristic for the topology optimization problem. For the prototypical district considered, advanced district thermal energy systems mated with low-exergy building heating and cooling systems achieved a source energy use intensity that was 49% lower than that of conventional systems. The minimal spanning tree heuristic was demonstrated to be effective for the network topology optimization problem in the context of a prototypical district, and contributes to mitigating the problem’s computational complexity. The work presented in this paper demonstrates the potential of advanced district thermal energy systems to achieve deep energy savings, and advances to addressing barriers to their adoption through topology optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗