Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building energy prediction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

Deploying advanced supervisory control strategies to small- and medium-sized commercial buildings: Case study and lessons learned

Deploying advanced supervisory control strategies (ASCSs) in small- and medium-sized commercial buildings (SMBs) is vital but faces two issues: (1) a lack of building control and communication infrastructure (BCCI) in SMBs and (2) the significant engineering efforts required to implement and configurate ASCSs. Despite hindering the large-scale adoption of ASCSs in SMBs, these issues have not been adequately explored in the literature, which tends to focus more on feasibility than scalability. This paper provides a comprehensive evaluation of these two issues through a case study of an occupied SMB in eastern Tennessee of the United States. Specifically, we design and implement a BCCI for the studied building with commercial off-the-shelf products to accommodate the needs for deploying ASCSs. Here, we then deploy two ASCSs—a rule-based setback control and a model predictive control (MPC)—with the BCCI and evaluate their performance throughout the summer of 2024. This study reveals that the main bottlenecks in establishing BCCIs for SMBs are the high initial cost (∼$56/m 2 ) and communication delays (up to 9 min). Additionally, the assessment of the two ASCSs indicates that the majority (∼75 %) of the engineering effort required for implementation and configuration is spent on model identification, debugging, and tuning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Study of Rotating Turbulence with External Forcing

Direct numerical simulation at 256(exp 3) resolution have been carried out to study the response of isotropic turbulence to the concurrent effects of solid-body rotation and numerical forcing at the large scales. Because energy transfer to the smaller scales is weakened by rotation, energy input from forcing gradually builds up at the large scales, causing the overall kinetic energy to increase. At intermediate wavenumbers the energy spectrum undergoes a transition from a limited k(exp -5/3) inertial range to k(exp -2) scaling recently predicted in the literature. Although the Reynolds stress tensor remains approximately isotropic and three-components, evidence for anisotropy and quasi- two-dimensionality in length scales and spectra in different velocity components and directions is strong. The small scales are found to deviate from local isotropy, primarily as a result of anisotropic transfer to the high wavenumbers. To understand the spectral dynamics of this flow we study the detailed behavior of nonlinear triadic interactions in wavenumber space. Spectral transfer in the velocity component parallel to the axis of rotation is qualitatively similar to that in non-rotating turbulence; however the perpendicular component is characterized by a greatly suppressed energy cascade at high wavenumber and a local reverse transfer at the largest scales. The broader implications of this work are briefly addressed.

Yeung, P. K.↗

A bi-level advanced control framework for large-scale control of buildings with system-level impact

Increased electricity consumption combined with new forms of generation is testing the reliability of our grid infrastructure. This work describes a method to improve the reliability of the grid through large-scale advanced building control. This paper develops a bi-level distributed control framework to shift the load of 153 buildings to achieve a system-level objective of tracking a power reference signal. This bi-level control is based on the previously-developed ANPV-MPC, a predictive controller that uses a Bayesian neural network to generate an accurate control model and adapt to changing conditions over time. By shifting the building electricity demand to better match the available power, the grid system supplying the buildings is more reliable as evidenced by the analysis of node voltages across an IEEE 13-bus distribution system. The proposed bi-level control framework tracks the system-level power reference with enough accuracy to regulate node voltages across the IEEE 13-bus distribution system within ANSI limits of ±5%. Additionally, the adaptive nature of ANPV-MPC allows each building across the system to adapt to changing conditions, further amplifying the system-level reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GPR_calculator: An on-the-fly surrogate model to accelerate massive nudged elastic band calculations

We present GPR_calculator, a package based on Python and C++ programming languages to build an on-the-fly surrogate model using Gaussian Process Regression (GPR) to approximate computationally expensive electronic structure calculations. The key idea is to dynamically train a GPR model during the simulation that can accurately predict energies and forces with uncertainty quantification. When the uncertainty is high, the costly electronic structure calculation is performed to obtain the ground truth data, which is then used to update the GPR model. To illustrate the effectiveness of GPR_calculator, we demonstrate its application in Nudged Elastic Band (NEB) simulations of surface diffusion and reactions, achieving 3-10 times acceleration compared to pure ab initio calculations. The source code is available at https://github.com/MaterSim/GPR_calculator.

Gaussian process regression↗

End-Use Savings Shapes Measure Documentation: Dispatch Schedule Generation for Demand Flexibility Measures

This supplemental document describes the methodology used for determining the dispatch timing of various EUSS demand flexibility measures. Demand flexibility measures are designed to reduce/dispatch electricity demand in buildings during especially beneficial/critical times. The method used in this work utilizes predictions of building loads to generate a schedule that reflects the periods when the building's daily peak load occurs to support decision making in demand flexibility measures. The dispatch schedule generation method described in this document creates an hourly schedule that includes a load dispatch (peak) window for each day for a whole year based on load prediction, with options using different prediction methods: perfect prediction, bin-sampling method, fixed schedule, and outdoor air temperature (OAT)-based prediction method. The perfect prediction method performs a simulation to obtain the annual load profile as predicted load, representing the scenario of perfect load prediction. The bin-sampling method (1) categorizes days into representative bins by temperature characteristics, (2) performs simulations on sample days from each of those bins to create representative (or predicted) load, and (3) assigns representative loads for all days in a year based on the bin categorization. The fixed schedule method defines uniform start and end time of peak window with assumed fixed daily peak time, for all days in a season or a year. The OAT-based prediction method uses the statistics of OAT (minimum and maximum) as the indicators of peak load, with specified delay response time from building loads to temperature. Given the load prediction, daily peak periods are determined as a time window with specified length in each day that include the predicted daily peak load and with a secondary rule such as maximizing energy saving potential. The dispatch schedule generation method is not a standalone measure and is intended to be combined with other demand flexibility measures that could leverage the peak schedule and apply demand controls on specific systems or devices for demand response, such as measures described in "Measure Documentation - Thermostat Control for Load Shedding" and "Measure Documentation - Thermostat Control for Load Shifting".

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving gas adsorption modeling for MOFs by local calibration of Hubbard U parameters

While computational screening with density functional theory (DFT) is frequently employed for the screening of metal–organic frameworks (MOFs) for gas separation and storage, commonly applied generalized gradient approximations (GGAs) exhibit self-interaction errors, which hinder the predictions of adsorption energies. We investigate the Hubbard U parameter to augment DFT calculations for full periodic MOFs, targeting a more precise modeling of gas molecule–MOF interactions, specifically for N2, CO2, and O2. We introduce a calibration scheme for the U parameter, which is tailored for each MOF, by leveraging higher-level calculations on the secondary building unit (SBU) of the MOF. When applied to the full periodic MOF, the U parameter calibrated against hybrid HSE06 calculations of SBUs successfully reproduces hybrid-quality calculations of the adsorption energy of the periodic MOF. The mean absolute deviation of adsorption energies reduces from 0.13 eV for a standard GGA treatment to 0.06 eV with the calibrated U, demonstrating the utility of the calibration procedure when applied to the full MOF structure. Furthermore, attempting to use coupled cluster singles and doubles with perturbative triples calculations of isolated SBUs for this calibration procedure shows varying degrees of success in predicting the experimental heat of adsorption. It improves accuracy for N2 adsorption for cases of overbinding, whereas its impact on CO2 is minimal, and ambiguities in spin state assignment hinder consistent improvements of O2 adsorption. Our findings emphasize the limitations of cluster models and advocate the use of full periodic MOF systems with a calibrated U parameter, providing a more comprehensive understanding of gas adsorption in MOFs.

Chemistry↗

Stochastic simulation of occupant-driven energy use in a bottom-up residential building stock model

The residential buildings sector is one of the largest electricity consumers worldwide and contributes disproportionally to peak electricity demand in many regions. Strongly driven by occupant activities, household energy consumption is stochastic and heterogeneous in nature. However, most residential energy models applied by industry use homogeneous, deterministic activity schedules, which work well for predictions of annual energy consumption, but can result in unrealistic hourly or sub-hourly electric load profiles, with exaggerated or muted peaks. The increasing proportion of variable renewable energy generators means that representing the heterogeneity and stochasticity of occupant behavior is now crucial for reliable planning at both bulk-power and distribution-system scales. This work presents a novel and open-source occupancy simulation approach that can simulate a diverse set of individual occupant and household event schedules for all major electricity, fuel, and hot water end uses. To accomplish this, we evaluated three alternative occupant activity simulation approaches before selecting a hybrid combining time-inhomogeneous Markov chains and probability-sampling of event durations and magnitudes. Further, we integrated the stochastic occupancy simulation with an open-source bottom-up physics-simulation building stock model and published a set of 550,000 diverse household end-use activity schedules representing a national housing stock. The simulator was verified against time-use survey data, and simulation results were validated against measured end-use electricity data for accuracy and reliability. While we use data for the United States, our application demonstrates how similar approaches could be applied using the time-use survey data collected in many countries around the world.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identification of Climatological Representative Days in the Mid-Atlantic for High-Fidelity Offshore Wind Energy Modeling

The goal of reaching 30 GW of offshore wind energy by 2030 becomes more realistic with the continued approval of offshore wind energy areas by the Biden Administration. In the Mid-Atlantic, where wind energy projects are in the most advanced stages of development, there is increased research focus on the eventual interaction of these wind farms. These interactions, in the form of wakes and cluster wakes, or wakes from multiple wind farms, could have detrimental effects on power production and forecastability for downwind wind farms (Pryor et al. 2022, Golbazi et al. 2022, Rosencrans et al. 2023). To help alleviate these issues, numerical simulations in the form of numerical weather prediction (NWP) and large eddy simulations (LES) can provide insight into when cluster wake situations may occur, but running such simulations can be expensive and difficult to run for multiple years. In this study, we leverage and build upon existing techniques in the literature (Fischereit et al. 2022) to identify climatologically representative days for wind energy areas in the Mid-Atlantic where conditions would promote cluster wake situations. We select meteorological variables (wind speed, wind direction, atmospheric stability, boundary-layer height, TKE) critical to understanding wind energy production and wake propagation. We then consider two different NWP datasets of varying spatial and temporal resolution: ERA5 provides data at hourly intervals from 1940 to present at 0.25 deg (31 km) spatial resolution (Hersbach et al. 2020), and the NOW-23 dataset provides data at 5-minute resolution for 21 years at 2-km spatial resolution (Bodini et al. 2020). Our first step is to compare these two datasets for an overlapping 21-year time period. Initial results show that the required number of days to represent the long-term climate increases with each additional variable considered. In their study of the German Bight, Fischereit et al. (2022) found that they could represent the long-term wind and wave climate in a "near-perfect" way with -180 days, by reaching a Perkins Skill Score (PSS) of 0.9; our investigation of the mid-Atlantic wind resource region with ERA5 and NOW-23 data suggests that we will need -100 days to reach a PSS of 0.9. As we expand our parameter space to include multiple variables, the number of required days will likely grow. These results will ultimately be used to select case studies to best represent cluster wake conditions that apply to this region for the lifetime of likely wind farms in this mid-Atlantic region.

clusterwakes↗

Improving Predictions Under Uncertainty of Material Plasma Device Operations

Understanding the properties of materials when exposed to various plasma temperatures and fluxes is essential to the building and operating of fusion reactors. The Material Plasma Exposure eXperiment (MPEX) is an instrument currently being developed by the Department of Energy (DOE) for this purpose. MPEX is expected to come online in stages over the next five years. Proto-MPEX, the predecessor to MPEX, operated from 2014 to 2021, and was designed to understand the generation of plasma temperatures and fluxes at orders of magnitude below what will be obtained by MPEX. This work uses the recently developed stochastic neural network (SNN), a machine learning technique capable of operating under uncertainty to provide a surrogate model for the Proto-MPEX device. We demonstrate that SNN outperforms Bayesian neural network (BNN), a standard in the field of machine learning with uncertainty. The development of a robust surrogate of the Proto-MPEX will aid in the commissioning and operation of the MPEX device.

Archibald, Rick↗

Unbundling Smart Meter Services Through Spatio-Temporal Decomposition Agents in DER-rich Environment

Smart meters and the advanced metering infrastructure (AMI) facilitate distribution system operators (DSOs) to gather information on energy consumption at the customer level. With the increasing penetration of building-level intermittent distributed energy resources (DERs) behind the meter, DER information is not available to DSOs. At the same time, smart meter enables users to participate in grid, with real-time information. Information for behind the meter is needed by user to coordinate building level assets for maximum benefits. The concept of unbundled smart meter (USM) needs agents to decompose smart meter measurements to provide service to DSO as well as customers. In this paper, we propose a Spatio-Temporal Decomposition Agent (STDA) for USM based on Artificial Intelligence (AI). STDA can help users optimize their energy usage, help DSO to utilize building assets for the grid operation. The energy usage strategy developed by STDA is suitable for different users, and can be customized by deep learning (DL) models according to the different energy consumption habits of each user. The power prediction performance results of various DL models and evaluation using a set of data from a Hawaii utility is presented. Furthermore, STDA integration with Home Energy management Systems (HEMS) to manage resources is presented and validated. STDA pre-processes the measurements before model training, and provides the spatio-temporal decomposed forecasting.

42 ENGINEERING↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

Scalable Implicit Solvers with Dynamic Mesh Adaptation for a Relativistic Drift-Kinetic Fokker–Planck–Boltzmann Model

In this work we consider a relativistic drift-kinetic model for runaway electrons along with a Fokker–Planck operator for small-angle Coulomb collisions, a radiation damping operator, and a secondary knock-on (Boltzmann) collision source. Here, we develop a new scalable fully implicit solver utilizing finite volume and conservative finite difference schemes and dynamic mesh adaptivity. A new data management framework in the PETSc library based on the p4est library is developed to enable simulations with dynamic adaptive mesh refinement (AMR), distributed memory parallelization, and dynamic load balancing of computational work. This framework and the runaway electron solver building on the framework are able to dynamically capture both bulk Maxwellian at the low-energy region and a runaway tail at the high-energy region. To effectively capture features via the AMR algorithm, a new AMR indicator prediction strategy is proposed that is performed alongside the implicit time evolution of the solution. This strategy is complemented by the introduction of computationally cheap feature-based AMR indicators that are analyzed theoretically. Numerical results quantify the advantages of the prediction strategy in better capturing features compared with nonpredictive strategies; and we demonstrate trade-offs regarding computational costs. The robustness with respect to model parameters, algorithmic scalability, and parallel scalability are demonstrated through several benchmark problems including manufactured solutions and solutions of different physics models. We focus on demonstrating the advantages of using implicit time stepping and AMR for runaway electron simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predictions of core plasma performance for the SPARC tokamak

SPARC is designed to be a high-field, medium-size tokamak aimed at achieving net energy gain with Ion Cyclotron Range-of-Frequencies (ICRF) as its primary auxiliary heating mechanism. Empirical predictions with conservative physics indicate that SPARC baseline plasmas would reach Q~11, well above its mission objective of Q>2. To build confidence that SPARC will be successful, physics-based integrated modeling has also been performed. The TRANSP code coupled with the theory-based TGLF turbulence model and EPED predictions for pedestal stability find that Q~9 is attainable in standard H-mode operation and confirms Q>2 operation is feasible even with adverse assumptions. In this analysis, ion cyclotron waves are simulated with the full wave TORIC code and alpha heating is modeled with the Monte-Carlo fast ion NUBEAM module. Detailed analysis of expected turbulence regimes with linear and nonlinear CGYRO simulations is also presented, demonstrating that profile predictions with the TGLF reduced model are in reasonable agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗