Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building energy simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NEAMS Burnup Extension Accomplishments and Remaining Modeling Gaps

The economic viability of light-water reactors (LWRs) in the United States is declining in heavily subsidized markets, and as a result, the nuclear industry is looking for opportunities to enhance the economic competitiveness of nuclear power. This is not a foreign concept to the nuclear industry: in the mid-2000s, the nuclear industry set out to achieve zero fuel failures by 2010. The goal in this effort was to drive down the cost of reactor shut down by replacing a pin or bundle in response to fuel rod failure. 2010 brought about the initiative to deliver the nuclear promise to reduce operating cost by 30% to improve nuclear energy’s economic competitiveness before 2020. The emergence of accident-tolerant fuel also offers the nuclear industry an opportunity to build on these past successes and deliver affordable, clean energy. Accident-tolerant fuel has been shown to provide superior performance compared to traditional Zircaloy/UO2 fuel concepts, offering the unique ability to remove operational limitations that inhibit the economic viability of nuclear power. This has led the industry to begin building a technical case to extend the peak rod average burnup beyond 62 GWd/tU to extend pressurized water reactor cycle lengths to 24 months and to develop more efficient boiling water reactor core designs. The Nuclear Energy Advanced Modeling and Simulation (NEAMS) program mission is to develop advanced modeling and simulation tools and capabilities to accelerate the deployment of advanced nuclear energy technologies. The primary safety concern inhibiting the nuclear industry from extending burnup is related to high-burnup fuel fragmentation, relocation, and dispersal. Therefore, the NEAMS program developed a targeted 5-year plan to support the industry’s efforts to extend burnup. This milestone report summarizes the 5-year plan that was enacted in FY20, followed by a discussion of the ongoing activates required to fulfill the 5-year plan, as well as the approach to address the current modeling gaps. Additionally, an LWR stakeholder meeting was held to communicate work performed in the NEAMS program over the past three years, to assess the LWR community’s perspective on the impact of the program, and to identify remaining significant gaps in the NEAMS suite of capabilities. This engagement will be documented by the Electric Power Research Institute and used by NEAMS to redirect current LWR scope as needed and to develop the next phase for LWR research and development.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A MATLAB/Simulink based GUI for the CERES Simulator

The Clouds and The Earth's Radiant Energy System (CERES) simulator will allow flight operational familiarity with the CERES instrument prior to launch. It will provide a CERES instrument simulation facility for NASA Langley Research Center. NASA Goddard Space Flight Center and TRW. One of the objectives of building this simulator would be for use as a testbed for functionality checking of atypical memory uploads and for anomaly investigation. For instance, instrument malfunction due to memory damage requires troubleshooting on a simulator to determine the nature of the problem and to find a solution.

Valencia, Luis H.↗

Developing a Control Strategy for Minimum Airflow Setting Considering CO2 Level and Energy Consumption in a Variable Air Volume System

In an office building equipped with a Variable Air Volume (VAV) system, this paper introduces a novel method for controlling the minimum supply airflow fraction in each zone’s VAV box, having a capability to consider indoor CO2 level and energy consumption. The EnergyPlus simulation using the medium office prototype model was employed, which evaluated the performance of the energy and CO2 concentration for five VAV box airflow control strategies. The paper focuses on CO2 concentration-based airflow control method and compares it with other four methods including conventional single-max, reduced minimum single-max, demand-controlled ventilation(DCV), and dualmax control methods according to guidelines and common practices. The newly proposed control strategy directly correlates the minimum airflow fraction to CO2 concentration. A general trend emerged when comparing CO2 concentrations—lower minimum airflow fractions were associated with higher concentrations. The proposed control method effectively maintained low CO2 concentrations and enabled a lower airflow fraction contributing to energy consumption reduction. It was confirmed that heating energy consumption in climate zone 4A, 5B, and 6A showed a maximum saving of approximately 30% compared to the conventional single-max and dual max control strategies. It was found that cooling energy consumption in climate zone 4A and 6A can achieve a maximum saving of approximately 10% compared to the conventional control strategies. The proposed CO2 concentration-based control logic is promising as it not only improves the indoor air quality lowering the CO2 concentration in the occupied spaces, but also contributes to HVAC energy savings.

Lee, Jong Man↗

Modeled Retrofit Package Performance for Schools

This report details modeled energy performance and savings from retrofit packages in prototypical school buildings in climate zones throughout the U.S. The information herein serves as a reference for elementary and secondary schools interested in implementing retrofit packages in their facilities for energy savings as well as health and safety benefits. School models developed for simulating package performance differentiated between rural and urban environments. Simulations were run for 10 distinct climate zones covering a range of climate conditions throughout the U.S. Results include savings estimates for electricity, natural gas, CO 2 emissions, and annual utility costs for nine different retrofit packages that combine energy conservation measures, including HVAC controls and equipment upgrades, lighting efficiency upgrades, and electrification technologies such as heat pumps for space conditioning and domestic hot water. Nine additional retrofit packages were also developed for elementary schools and modeled in two climate zones. Appendix B describes the additional retrofit packages and presents savings estimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Summary of NASA-Lewis Research Center solar heating and cooling and wind energy programs

NASA is planning to construct and operate a solar heating and cooling system in conjunction with a new office building being constructed at Langley Research Center. The technology support for this project will be provided by a solar energy program underway at NASA's Lewis Research Center. The solar program at Lewis includes: testing of solar collectors with a solar simulator, outdoor testing of collectors, property measurements of selective and nonselective coatings for solar collectors, and a solar model-systems test loop. NASA-Lewis has been assisting the National Science Foundation and now the Energy Research and Development Administration in planning and executing a national wind energy program. The areas of the wind energy program that are being conducted by Lewis include: design and operation of a 100 kW experimental wind generator, industry-designed and user-operated wind generators in the range of 50 to 3000 kW, and supporting research and technology for large wind energy systems. An overview of these activities is provided.

Vernon, R. W.↗

2-kW Solar Dynamic Space Power System Tested in Lewis' Thermal Vacuum Facility

Working together, a NASA/industry team successfully operated and tested a complete solar dynamic space power system in a large thermal vacuum facility with a simulated sun. This NASA Lewis Research Center facility, known as Tank 6 in building 301, accurately simulates the temperatures, high vacuum, and solar flux encountered in low-Earth orbit. The solar dynamic space power system shown in the photo in the Lewis facility, includes the solar concentrator and the solar receiver with thermal energy storage integrated with the power conversion unit. Initial testing in December 1994 resulted in the world's first operation of an integrated solar dynamic system in a relevant environment.

Source record↗

Modeling and Analysis of a Heat Pump Clothes Dryer with Thermal Energy Storage

Clothes drying is an energy-intensive process that causes significant electricity consumption and carbon emissions in the US. Approximately 83% of Households in the US own a tumble clothes dryer at home and 80% of dryers are electrical resistance dryers with low energy efficiency. Heat pump technology makes it possible for highly efficient and clean drying. Additionally, the ventless design of heat pump clothes dryers (HPCD) provides more installation flexibility. HPCD involves three primary mediums: wet clothes, a closed air loop, and a refrigerant circuit. The evaporator is used to dehumidify the wet air and the condenser is used to re-heat the dry air. One of the critical technological barriers to HPCD market penetration is its long drying time, primarily due to the relatively low discharging temperature and the slow response during the warm-up period. In this study, the thermal energy storage (TES) technology is adopted to address this challenge by providing pre-heating of air prior to the condenser to increase the operating temperature of the process air. The heat pump will charge the phase change material (PCM) in the TES device with heating energy during clothes washing and the PCM will discharge the stored heat to facilitate air heating during clothes drying. To analyze the optimal design and potential for energy saving and drying time reduction, a mathematical model of the HPCD system was developed. The HPCD is a highly dynamic system with a coupled heat and mass transfer and heat pumping cycle. This paper provides solutions to simulate the transient behavior of the system while maintaining low computational cost. The modeling result indicates reduced energy consumption and drying time by integrating TES with HPCD, as compared to electrical resistance dryers. The study can provide significant insights into improving building flexibility with TES and smart appliances.

Liu, Xiaoli↗

Machine Learning-Driven Optimization of Building Enclosures for Moisture Durability and Thermal Performance

The design of moisture-durable building enclosures with low embodied carbon often involves an iterative process of selecting the materials for the specific exposure conditions to meet the performance requirements. While hygrothermal simulations are commonly used to evaluate moisture durability, they often require advanced expertise for proper implementation. Machine learning (ML) provides a promising alternative by streamlining the design process and minimizing the reliance on complex simulations. This study presents a machine learning-based approach for predicting moisture durability in residential wall assemblies. The ML model was trained to estimate the mold index and maximum moisture content of various layers under typical exposure conditions. The model achieved a high predictive accuracy, with a coefficient of determination (R²) exceeding 0.90 when compared to traditional hygrothermal simulations on materials that were not part of training the ML model. Building on these results, the ML model was developed into a practical tool for optimizing wall assembly designs. This tool allows users to automatically optimize material selections based on energy, moisture, and carbon performance criteria. By incorporating multi-objective optimization, the tool identifies configurations that minimize embodied carbon while maintaining moisture safety and code-compliant thermal performance. Additionally, it provides insights into how material choices influence assembly durability, energy efficiency, and carbon reduction. The tool will be implemented in the Building Science Advisor (BSA) to enhance its performance and provide more granularity on the results. This research highlights the potential for ML-driven tools to simplify the design of high-performance building enclosures, offering architects and engineers a faster, more efficient way to balance critical performance factors.

Salonvaara, Mikael [ORNL] (ORCID:0000000318991554)↗

Status of New Models Hosted on the Virtual Test Bed (VTB) in 2024

The National Reactor Innovation Center (NRIC) mission is to support deployment of novel reactor concepts. This is achieved by providing physical and virtual spaces for building and testing various components, systems, and complete pilot plants. The Virtual Test Bed (VTB) represents the virtual counterpart to the physical test bed. It is in development in collaboration with the Department of Energy’s (DOE) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. The mission of the VTB is to accelerate the deployment and licensing of advanced reactors by leveraging state-of-the-art modeling and simulation (M&S) tools developed by the DOE NEAMS program. This is accomplished by three primary means: (1) openly hosting simulations that showcase analysis capabilities, (2) continuously testing the models hosted against code updates to avoid deprecation, and (3) filling key M&S gaps that are relevant for the physical NRIC test beds. The VTB repository consists of two sub-entities: 1. A documentation website detailing the models (https://mooseframework.inl.gov/virtual_test_bed). 2. A GitHub repository that hosts the corresponding files (https://github.com/idaholab/virtual_test_bed). Previous documentation on the models hosted in the VTB can be found in [1,2,3,4]. These references also include additional background information on the various NEAMS codes showcased in the VTB (which is omitted here for brevity). This paper primarily provides a status update of the most recent additions to the repository.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

Advanced Stirling Convertor (ASC) - From Technology Development to Future Flight Product

The Advanced Stirling Convertor (ASC) is being developed by Sunpower, Inc. under contract to NASA s Glenn Research Center (GRC) with critical technology support tasks lead by GRC. The ASC development, funded by NASA s Science Mission Directorate, started in 2003 as one of 10 competitively awarded contracts that were to address future Radioisotope Power System (RPS) advanced power conversion needs. The ASC technology has since evolved through progressive convertor builds and successful testing to demonstrate high conversion efficiency (38 %), low mass (1.3 kg), hermetic sealing, launch vibration simulation, EMI characterization, and is undergoing extended operation. The GRC and Sunpower team recently delivered three ASC-E machines to the Department of Energy (DOE) and Lockheed Martin Space Systems Company, two units for integration onto the Advanced Stirling Radioisotope Generator Engineering Unit (ASRG EU) plus one spare. The design has recently been initiated for the ASC-E2, an evolution from the ASC-E that substitutes higher temperature materials enabling improved performance and higher reliability margins. This paper summarizes the history and status of the ASC project and discusses plans for this technology which enables RPS specific power of 8 W/kg for future NASA missions.

Wong, Wayne A.↗

Infrastructure improvements in the National Reactor Innovation Center Virtual Test Bed

The National Reactor Innovation Center’s (NRIC) mission is to support deployment of novel reactor concepts. This is achieved by providing physical and virtual spaces for building and testing various components, systems, and complete pilot plants. The Virtual Test Bed (VTB) represents the virtual counterpart to the physical test bed. The VTB is being developed in collaboration with the Department of Energy’s (DOE) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. The mission of the VTB is to accelerate the deployment and licensing of advanced reactors by leveraging state-of-the-art modeling and simulation (M&S) tools developed by the DOE NEAMS program. This is accomplished via three primary means: (1) openly hosting simulations that showcase analysis capabilities, (2) continuously testing the models hosted against code updates to avoid deprecation, and (3) filling key M&S gaps that are relevant for the physical NRIC test beds. The VTB repository consists of two sub-entities: • A documentation website detailing the models: https://mooseframework.inl.gov/virtual_test_bed • A GitHub repository that hosts the corresponding files: https://github.com/idaholab/virtual_test_bed. This paper presents the infrastructure added to the VTB in the last two fiscal years. Additional information about the VTB can be found in various publications [1, 2, 3, 4, 5, 6, 7, 8].

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

An open-access simulated earthquake ground-motion database for an M7 Hayward Fault earthquake in the San Francisco Bay Region

Comprehensive understanding of earthquake ground motions, particularly in the near-fault region of large-magnitude events, is limited by gaps in strong-motion data. This challenge is prominent in areas with high seismic hazard but infrequent large earthquakes where data is sparse and difficult to interpret. These data limitations lead to uncertainties in the development of site-specific ground motions, which are crucial for engineering risk assessments. To address these challenges, physics-based regional-scale ground-motion simulations have been developed. With the emergence of exaflop-scale computing ecosystems, it is now possible to simulate regional earthquake processes at unprecedented fidelity and generate the large number of fault rupture realizations necessary to characterize both intra- and inter-event ground-motion variability. This article introduces a new database of simulated earthquake ground motions, created for applications in earthquake engineering, earthquake planning, and emergency response. The inaugural version of the database features simulated ground motions for a magnitude 7 Hayward Fault earthquake in the San Francisco Bay Region (SFBR), using the EarthQuake SIMulation (EQSIM) simulation framework and the Graves–Pitarka kinematic rupture model. The aim is to provide high-fidelity, spatially dense, three-component motions generated on the Department of Energy’s (DOE) newest generation of graphics processing unit (GPU)-accelerated supercomputers. These motions are being made openly available to the engineering, scientific, and disaster planning communities. In addition, this work develops protocols for the efficient dissemination of these large data sets and emphasizes community engagement to build confidence in their application. This article discusses the methodology behind the data, underlying software verification and validation, scalable data management, and a user interface for data access. The goal is to facilitate widespread use and elicit expert feedback to maximize the utility and exploitation of simulated motions. While the initial focus is on the San Francisco Region, simulations for additional regions will be added as the DOE program progresses.

Simulated ground-motion database↗

Quench Simulation and Validation for EIC Direct Wind Magnets

The Electron-Ion Collider (EIC), a new facility to be built in the United States at the U.S. Department of Energy’s Brookhaven National Laboratory in collaboration with Thomas Jefferson National Accelerator Facility-will be the only new particle collider in the U.S. for the next 10∼20 years. The EIC project will investigate the origin of mass and building blocks of the Universe. It will accelerate and collide beams of electrons with protons and nuclei. Unlike any collider that has ever existed before, both EIC’s particle beams will be polarized, meaning their spins will be aligned in a controlled way to allow for precision measurements. Different types of new superconducting magnets will be required near the interaction region (IR) of EIC. A 6-around-1 NbTi cable will be used for some of those new superconducting magnets. Given the relatively smaller conductors used for those direct wind magnets, the overall engineering current density will be 2–3 times higher in comparison to traditional collared superconducting magnets in other accelerator magnets. This is technically challenging and potentially represents high risks for quench protection. Here, in this paper we use different tools and methods for quench simulation for several EIC direct wind magnets. We also present results of a sensitivity study, exploring different material properties and Jc curves. This paper also discusses and validates the quench simulation results with measurement results from a small-scale serpentine magnet tested at BNL in October 2024.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Statistical Downscaling of Climate Models for Solar Resource Assessment

This study presents the development of statistical models to efficiently downscale future projections of solar irradiance for solar energy applications. A climate data set simulated from a Regional Climate Model (RCM) obtained from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) is selected as input to the statistical models to create high-resolution global horizontal irradiance (GHI) over the contiguous United States (CONUS). Our approach builds statistical downscaling models that (1) regrid RCM data (0.22 degree and daily spatiotemporal resolution), (2) correct bias of GHI projections, (3) downscale the future GHI project from daily-scale to hourly-scale, and (4) spatially downscale to generate GHI at 8-km resolution. To calibrate and validate the statistical models, we adapt and use the National Solar Radiation Database (NSRDB). Preliminary results show that the statistical downscaling approach downscales future projections of GHI under two climate scenarios (RCP4.5 and RCP8.5) with a nBIAS of 3%, nMAE of 34% and nRMSE of 46% estimated against NSRDB for the contiguous United State. This presentation will summarize the implemented methodology and validation results as well as future extension of this research.

climate data↗

Bill Savings vs. Backup Power: Evaluating operational tradeoffs for home solar+storage systems [Slides]

Adoption of residential solar photovoltaic+energy storage systems (PVESS) is driven by both bill savings opportunities and customer demand for backup power. Prior work by this team (Gorman et al., 2022; Gorman et al., 2023) explored PVESS backup power capabilities during long-duration power interruptions (e.g., due to severe weather events), when customers are assumed to be able to anticipate the event and charge their batteries in advance. In many cases, however, power interruptions are unpredictable (and often relatively short); for those types of events, a customer will typically set its battery to maintain some minimum capacity in reserve in case of an interruption, which reduces the capacity available for managing utility bills. This study evaluates this operational tradeoff to help customers and installers configure backup reserve settings, and to inform decision-making more generally about the customer value of backup power services compared to utility bill savings. This study utilizes Berkeley Lab’s PRESTO tool to produce stochastic simulations of (predominantly short-duration) power interruption events, and builds on an earlier case-study demonstrating PVESS backup performance during short-duration interruptions (Baik et al., 2023).

14 SOLAR ENERGY↗

DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]

This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.

Huang, Ransisi↗