Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building performance simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Analysis of radiant cooling system integrated with cooling tower for composite climatic conditions

Increased demand for cooling leads to consumption of a significant amount of energy by heating, ventilation, and air conditioning (HVAC) systems in buildings. Building envelope acts as a thermal barrier and plays a significant role in improving building energy efficiency. Radiant cooling systems often utilize building structure in the form of thermal storage and provide thermal comfort. The radiant cooling system has the potential of saving peak power in the buildings. In present study experimental and a simulation study is performed for chiller and cooling tower integrated chilled ceiling radiant cooling system for chilled water source and a parallel dedicated outdoor air system (DOAS) is used for providing latent load and fresh air requirements of the zone. Cooling tower based radiant cooling system is compared with a chiller-based radiant cooling system for achieving annual energy saving. Experiments are conducted for the chiller and cooling tower operated radiant cooling system. Based on experimental data, whole building simulation models of both cooling tower and chiller-based systems were calibrated. For both the simulation model of chiller and cooling tower operated radiant cooling system simulation were carried out for round the year. The annual simulation results show that the cooling tower operated radiant cooling system saves 14% energy as compared to the chilled water operated radiating cooling system.

Srivastava, Prateek↗

AirflowNetwork [SWR 19-45]

The AirflowNetwork software provides the ability to simulate air movement and the resulting transport of contaminants and other materials within a building. The performance of air distribution systems, including supply and return leaks, and multizone airflows driven by outdoor wind and forced air during HVAC system operation are simulated using a nodal network representation of the building. The pressure network model implemented here is based on George Walton's AIRNET and was modified for inclusion in the EnergyPlus building energy modeling software. The algorithm were then extracted from EnergyPlus into a stand-alone package to facility use without the building energy model and more extensive testing and validation of the underlying operations.

DeGraw, Jason↗

A performance study of the time-varying cache behavior: a study on APEX, Mantevo, NAS, and PARSEC

Cache has long been used to minimize the latency of main memory accesses by storing frequently used data near the processor. Processor performance depends on the underlying cache performance. Therefore, significant research has been done to identify the most crucial metrics of cache performance. Although the majority of research focuses on measuring cache hit rates and data movement as the primary cache performance metrics, cache utilization is significantly important. We investigate the application’s locality using cache utilization metrics. In addition, we present cache utilization and traditional cache performance metrics as the program progresses providing detailed insights into the dynamic application behavior on parallel applications from four benchmark suites running on multiple cores. We explore cache utilization for APEX, Mantevo, NAS, and PARSEC, mostly scientific benchmark suites. Our results indicate that 40% of the data bytes in a cache line are accessed at least once before line eviction. Also, on average a byte is accessed two times before the cache line is evicted for these applications. Moreover, we present runtime cache utilization, as well as, conventional performance metrics that illustrate a holistic understanding of cache behavior. To facilitate this research, we build a memory simulator incorporated into the Structural Simulation Toolkit (Rodrigues et al. in SIGMETRICS Perform Eval Rev 38(4):37–42, 2011). Finally, our results suggest that variable cache line size can result in better performance and can also conserve power.

97 MATHEMATICS AND COMPUTING↗

Simulator for concurrent processing data flow architectures

A software simulator capability of simulating execution of an algorithm graph on a given system under the Algorithm to Architecture Mapping Model (ATAMM) rules is presented. ATAMM is capable of modeling the execution of large-grained algorithms on distributed data flow architectures. Investigating the behavior and determining the performance of an ATAMM based system requires the aid of software tools. The ATAMM Simulator presented is capable of determining the performance of a system without having to build a hardware prototype. Case studies are performed on four algorithms to demonstrate the capabilities of the ATAMM Simulator. Simulated results are shown to be comparable to the experimental results of the Advanced Development Model System.

Malekpour, Mahyar R.↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Performance Evaluation of Attic Radiant Barrier Systems Using the Large Scale Climate Simulator (LSCS)

Application of radiant barriers and low-emittance surface coatings in residential building attics can significantly reduce conditioning loads from heat flow through attic floors. The roofing industry has been developing and using various radiant barrier systems and low-emittance surface coatings to increase energy efficiency in buildings; however, minimal data are available that quantifies the effectiveness of these technologies. This study evaluates performance of various attic radiant barrier systems under simulated summer daytime conditions and nighttime or low solar gain daytime winter conditions using the large scale climate simulator (LSCS). The four attic configurations that were evaluated are 1) no radiant barrier (control), 2) perforated low-e foil laminated oriented strand board (OSB) deck, 3) low-e foil stapled on rafters, and 4) liquid applied low-emittance coating on roof deck and rafters. All test attics used nominal RUS 13 h-ft2- F/Btu (RSI 2.29 m2-K/W) fiberglass batt insulation on attic floor. Results indicate that the three systems with radiant barriers had heat flows through the attic floor during summer daytime condition that were 33%, 50%, and 19% lower than the control, respectively.

building energy efficiency↗

Assessment of occupant-behavior-based indoor air quality and its impacts on human exposure risk: A case study based on the wildfires in Northern California

he recent wildfires in California, U.S., have caused not only significant losses to human life and property, but also serious environmental and health issues. Ambient air pollution from combustion during the fires could increase indoor exposure risks to toxic gases and particles, further exacerbating respiratory conditions. This work aims at addressing existing knowledge gaps in understanding how indoor air quality is affected by outdoor air pollutants during wildfires -- by taking into account occupant behaviors (e.g., movement, operation of windows and air-conditioning) which strongly influence building performance and occupant comfort. A novel modeling framework was developed to simulate the indoor exposure risks considering the impact of occupant behaviors by integrating building energy and occupant behaviour modeling with computational fluid dynamics simulation. Occupant behaviors were found to exert significant impacts on indoor air flow patterns and pollutant concentrations, based on which, certain behaviors are recommended during wildfires. Further, the actual respiratory injury level under such outdoor conditions was predicted. The modeling framework and the findings enable a deeper understanding of the actual health impacts of wildfires, as well as informing strategies for mitigating occupant health risk during wildfires.

54 ENVIRONMENTAL SCIENCES↗

Numerical simulation of buoyancy-driven turbulent ventilation in attic space under winter conditions

Attic design and construction have significant impacts on residential buildings’ energy performance. In order to understand how passive ventilation rates affect ridge-vent attic's performance, a two-dimensional steady-state finite volume model is employed to simulate the buoyancy-driven turbulent ventilation and heat transfer in a triangular attic space of a gable-roof residential building under winter conditions. The modeled attic has a pitch of 5/12 and a passive ventilation system, consisting of continuous ridge and soffit vents. The v2f model is used to analyze the turbulent air flow and natural convection heat transfer inside the attic. The effects of ambient air temperature, vent size, and ceiling insulation on heating load and ice dam formation are investigated. The thermal performance of the vented attic is compared with a sealed attic as well. Here, the simulation results reveal that symmetrical air flow patterns exist in a vented attic, in contrast to the asymmetrical air flow patterns found in a sealed attic. In addition, it is suggested that increasing vent size results in higher ventilation air flow rate but barely affects the attic heating load, and that both sufficient ventilation and insulation are needed to ensure the proper functions of the attic and its energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field test and simulation evaluation of variable refrigerant flow systems performance

Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. The same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating operation. As a result, energy consumption of the VRF system was reduced by more than that of the RTU by 55% approximately.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of a solar cooling system with interior energy storage

This paper focuses on the optimization of the performance of a solar absorption cooling system composed by four units with interior energy storage. A full dynamic simulation model that includes the solar collector field, the absorption heat pump system and the building load calculation has been developed. It has been applied to optimize the coupling of a system based on this new technology of solar powered absorption heat pump, to a bioclimatic building recently constructed in the Plataforma Solar de Almeria (PSA) in Spain. The absorption heat pump system considered is composed by four heat pumps that store energy in the form of crystallized salts so that no external storage capacity is required. Each heat pump is composed of two separate barrels that can charge (store energy from the solar field) and discharge (deliver heat or cold to the building) independently. Different configurations of the four units have been analysed taking into account the storage possibilities of the system and its capacity to respond to the building loads. It has been shown how strong the influence of the control strategies in the overall performance is, and the importance of using hourly simulations models when looking for highly efficient buildings. (author)

14 SOLAR ENERGY↗

AutoBEM: A scalable framework for nationwide building energy simulation and retrofit evaluation in the United States

This paper presents AutoBEM, an integrated, automated framework for nationwide building energy modeling and retrofit evaluation in the United States. Unlike prior UBEM platforms that either rely primarily on representative stock sampling or operate at city scale, AutoBEM automates the generation of building-resolved, physics-based EnergyPlus/OpenStudio simulation models at national scale using GIS-derived geometry, prototype-based assumptions, and standardized scalable workflows. Leveraging the Model America dataset and high-performance computing, AutoBEM generates and simulates energy models for 122.9 million buildings, representing 97.8% of the U.S. building stock. These models are being made publicly and freely available as the Model America v1.0 (MAv1) dataset. AutoBEM supports detailed, building-level assessments of energy consumption, CO2 emissions, and post-processed anthropogenic heat emissions (AHE), and evaluates 151 energy conservation measures (ECMs) using localized utility pricing and building characteristics. In addition, AutoBEM incorporates both typical and future climate conditions through integration with Typical Meteorological Year (TMY) and Future TMY (fTMY) weather data derived from IPCC scenarios. In a case study of Phoenix, Arizona, AutoBEM identified several high-efficiency HVAC upgrades and selected envelope measures with short modeled payback periods (1.5 years) for certain building types and standards. Simulations under future climate scenarios (SSP5–RCP8.5) project an 11.3% increase in electricity use and a 32% reduction in natural gas demand by 2100, underscoring the need for climate-adaptive retrofit planning. By enabling reproducible, bottom-up, and location-specific analysis at scale, AutoBEM provides a step toward a national digital twin of the built environment and supports data-driven screening and planning for decarbonization, resilience, and energy equity.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

Design of a lens table for a double toroidal electron spectrometer

We report here on the method we developed to build a lens table for a four-element electrostatic transfer lens operated together with a double toroidal electron energy analyzer designed by one of us, and whose original design and further improvements are described in detail in Miron et al. [Rev. Sci. Instrum. 68, 3728 (1997)] and Le Guen et al. [Rev. Sci. Instrum. 73, 3885 (2002)]. Both computer simulations and laboratory instrument tuning were performed in order to build this lens table. The obtained result was tested for a broad range of electron kinetic energies and analyzer pass energies. Based on this new lens table, allowing to easily computer control the spectrometer working conditions, we could routinely achieve an electron energy resolution ranging between 0.6% and 0.8% of the analyzer pass energy, while the electron count rate was also significantly improved. The establishment of such a lens table is of high importance to relieve experimentalists from the tedious laboring of the lens optimization, which was previously necessary prior to any measurement. The described method can be adapted to any type of electron/ion energy analyzer, and will thus be interesting for all experimentalists who own, or plan to build or improve their charged particle energy analyzers.

43 PARTICLE ACCELERATORS↗

An inverse approach to solving zone air infiltration rate and people count using indoor environmental sensor data

Physics-based simulation of energy use in buildings is typically widely used in building design and performance rating, controls design and operations. However, various challenges exist in the modeling process. Model parameters such as people count and air infiltration rate are usually highly uncertain, yet they have significant impacts on the simulation accuracy. With the increasing availability and affordability of sensors and meters in buildings, a large amount of measured data has been collected including indoor environmental parameters, such as room air dry-bulb temperature, humidity ratio, and CO 2 concentration levels. Fusing these sensor data with traditional energy modeling poses new opportunities to improve simulation accuracy. This study develops a set of physics-based inverse algorithms which can solve the highly uncertain and hard-to-measure building parameters such as zone-level people count and air infiltration rate. A simulation-based case study is conducted to verify the inverse algorithms implemented in EnergyPlus covering various sensor measurement scenarios and different modeling use cases. The developed inverse models can solve the zone people count and air infiltration at sub-hourly resolution using the measured zone air temperature, humidity and/or CO 2 concentration given other easy-to-measure model parameters are known.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robotic Specialization in Autonomous Robotic Structural Assembly

Robotic in-space assembly of large space structures is a long-term NASA goal to reduce launch costs and enable larger scale missions. Recently, researchers have proposed using discrete lattice building blocks and co-designed robots to build high-performance, scalable primary structure for various on-orbit and surface applications. These robots would locomote on the lattice and work in teams to build and reconfigure building-blocks into functional structure. However, the most reliable and efficient robotic system architecture, characterized by the number of different robotic 'species' and the allocation of functionality between species, is an open question. To address this problem, we decompose the robotic building-block assembly task into functional primitives and, in simulation, study the performance of the the variety of possible resulting architectures. For a set consisting of five process types (move self, move block, move friend, align bock, fasten block), we describe a method of feature space exploration and ranking based on energy and reliability cost functions. The solution space is enumerated, filtered for unique solutions, and evaluated against energy and reliability cost functions for various simulated build sizes. We find that a 2 species system, dividing the five mentioned process types between one unit cell transport robot and one fastening robot, results in the lowest energy cost system, at some cost to reliability. This system enables fastening functionality to occupy the build front while reducing the need for that functional mass to travel back and forth from a feed station. Because the details of a robot design affect the weighting and final allocation of functionality, a sensitivity analysis was conducted to evaluate the effect of changing mass allocations on architecture performance. Future systems with additional functionalities such as repair, inspection, and others may use this process to analyze and determine alternative robot architectures.

Bernus, Borbala↗

Mars Science Laboratory Flight Software Boot Robustness Testing Project Report

On the surface of Mars, the Mars Science Laboratory will boot up its flight computers every morning, having charged the batteries through the night. This boot process is complicated, critical, and affected by numerous hardware states that can be difficult to test. The hardware test beds do not facilitate testing a long duration of back-to-back unmanned automated tests, and although the software simulation has provided the necessary functionality and fidelity for this boot testing, there has not been support for the full flexibility necessary for this task. Therefore to perform this testing a framework has been build around the software simulation that supports running automated tests loading a variety of starting configurations for software and hardware states. This implementation has been tested against the nominal cases to validate the methodology, and support for configuring off-nominal cases is ongoing. The implication of this testing is that the introduction of input configurations that have yet proved difficult to test may reveal boot scenarios worth higher fidelity investigation, and in other cases increase confidence in the robustness of the flight software boot process.

Mars Science Laboratory (MSL)↗

Coupling multi-fidelity xRAGE with machine learning for graded inner shell design optimization in double shell capsules

Bayesian optimization has shown promise for the design optimization of inertial confinement fusion targets. Specifically, in Vazirani et al. [Phys. Plasmas 28 , 122709 (2021)], optimal designs for double shell capsules with graded inner shells were identified using one-dimensional xRAGE simulation yield calculations. While the machine learning models were able to accurately learn and predict one-dimensional simulation target performance, using simulations with higher fidelity would improve design optimization and better match with the expected experimental performance. However, higher fidelity physics modeling, i.e., two-dimensional xRAGE simulations, requires significantly larger computational time/cost, usually at least an order of magnitude, in comparison with one-dimensional simulations. This study presents a multi-fidelity Bayesian optimization, in which the machine learning model leverages low-fidelity (one-dimensional xRAGE) and high-fidelity (two-dimensional xRAGE) simulations to more accurately predict “pre-shot” target performance with respect to the expected experimental performance. By building a multi-fidelity Bayesian optimization framework coupled with xRAGE, the low-fidelity and high-fidelity simulations are able to inform one another, such that we have: (1) improved physics modeling in comparison with using low-fidelity simulations alone, (2) reduced computational time/cost in comparison with using high-fidelity simulations alone, and (3) more confidence in the expected performance of optimized targets during real-world experiments. In the future, we plan to use this robust multi-fidelity Bayesian optimization methodology to expedite the design of graded inner shells further and eventually full capsules as a part of the current double shell campaign at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Foresee: A user-centric home energy management system for energy efficiency and demand response

This paper presents foresee, a user-centric home energy management system that can help optimize how a home operates to concurrently meet users' needs, achieve energy efficiency and commensurate utility cost savings, and reliably deliver grid services based on utility signals. Foresee is built on a multiobjective model predictive control framework, wherein the objectives consist of energy cost, thermal comfort, user convenience, and carbon emission. Foresee learns user preferences on different objectives and acts on their behalf to operate building equipment, such as home appliances, photovoltaic systems, and battery storage. In this work, machine-learning algorithms were used to derive data-driven appliance models and usage patterns to predict the home's future energy consumption. This approach enables highly accurate predictions of comfort needs, energy costs, environmental impacts, and grid service availability. Simulation studies were performed on field data from a residential building stock data set collected in the Pacific Northwest. Results indicated that foresee generated up to 7.6% whole-home energy savings without requiring substantial behavioral changes. When responding to demand response events, foresee was able to provide load forecasts upon receipt of event notifications and delivered the committed demand response services with 10% or fewer errors. Foresee fully utilized the potential of the battery storage and controllable building loads and delivered up to 7.0-kW load reduction and 13.5-kW load increase. As a result, these benefits are provided while maintaining the occupants' thermal comfort or convenience in using their appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Machine Learning to Assist a Moisture Durability Tool

The design of moisture-durable building enclosures is complicated by the number of materials, exposure conditions, and performance requirements. Hygrothermal simulations are used to assess moisture durability, but these require in-depth knowledge to be properly implemented. Machine learning (ML) offers the opportunity to simplify the design process by eliminating the need to carry out hygrothermal simulations. ML was used to assess the moisture durability of a building enclosure design and simplify the design process. This work used ML to predict the mold index and maximum moisture content of layers in typical residential wall constructions. Results show that ML, within the constraints of the construction, including exposure conditions, does an excellent job in predicting performance compared to hygrothermal simulations with a coefficient of determination, R2, over 0.90. Furthermore, the results indicate that the material properties of the vapor barrier and continuous insulation layer are strongly correlated to performance.

36 MATERIALS SCIENCE↗