Search NASA⌕ Search

SEARCH · Search NASA

Results for “CARBON DIOXIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Metal oxide absorbents for regenerative carbon dioxide and water vapor removal for advanced portable life support systems

Recent studies of Allied Signal metal oxide based absorbents demonstrated that these absorbents offer a unique capability to regeneratively remove both metabolic carbon dioxide and water vapor from breathing air; previously, metal oxides were considered only for the removal of CO2. The concurrent removal of CO2 and H2O vapor can simplify the astronaut Portable Life Support System (PLSS) by combining the CO2 and humidity control functions into one regenerative component. The use of metal oxide absorbents for removal of both CO2 ad H2O vapor in the PLSS is the focus of an ongoing program. The full scale Metal Oxide Carbon dioxide and Humidity Remover (MOCHR) and regeneration unit is described.

Hart, Joan M.↗

A flow-system comparison of the reactivities of calcium superoxide and potassium superoxide with carbon dioxide and water vapor

A single pass flow system was used to test the reactivity of calcium superoxide with respiratory gases and the performance was compared to that of potassium superoxide. The KO2 system is used by coal miners as a self-contained unit in rescue operations. Particular attention was given to the reactivity with carbon dioxide and water vapor at different temperatures and partial pressures of oxygen, carbon dioxide, and water vapor. The calcium superoxide beds were found to absorb CO2 and H2O vapor, releasing O2. The KO2 bed, however, released O2 at twice the rate of CO2 absorption at 37 C. It is concluded that the calcium superoxide material is not a suitable replacement for the KO2 bed, although Ca(O2)2 may be added to the KO2 bed to enhance the CO2 absorption.

Wood, P. C.↗

Progress on High-Energy 2-micron Solid State Laser for NASA Space-Based Wind and Carbon Dioxide Measurements

Sustained research efforts at NASA Langley Research Center during last fifteen years have resulted in significant advancement of a 2-micron diode-pumped, solid-state laser transmitter for wind and carbon dioxide measurements from ground, air and space-borne platforms. Solid-state 2-micron laser is a key subsystem for a coherent Doppler lidar that measures the horizontal and vertical wind velocities with high precision and resolution. The same laser, after a few modifications, can also be used in a Differential Absorption Lidar system for measuring atmospheric CO2 concentration profiles. Researchers at NASA Langley Research Center have developed a compact, flight capable, high energy, injection seeded, 2-micron laser transmitter for ground and airborne wind and carbon dioxide measurements. It is capable of producing 250 mJ at 10 Hz by an oscillator and one amplifier. This compact laser transmitter was integrated into a mobile trailer based coherent Doppler wind and CO2 DIAL system and was deployed during field measurement campaigns. This paper will give an overview of 2-micron solid-state laser technology development and discuss results from recent ground-based field measurements.

Singh, Upendra N.↗

Ground Testing of 2-µm Triple-Pulse IPDA Lidar for Carbon Dioxide and Water Vapor Measuremets

A triple-pulse, 2-µm, Integrated Path Differential Absorption (IPDA) lidar was developed at NASA Langley Research Center. This active remote sensing instrument provides a technique for measuring atmospheric carbon dioxide and water vapor simultaneously and independently. A 2-µm high-energy pulsed laser is incorporated for the IPDA transmitter, which provides high signal-to-noise ratio measurements using a commercial direct detection system. This results in a high-precision measurement capability for the low troposphere weighted-average column dry-air volume mixing ratio of the gases. Recent IPDA ground testing indicated carbon dioxide and water vapor measurements sensitivities of 8% and 14%, respectively and biases of 0.1%. However, using the R30 centerline position for the on-line enhances the CO2 measurement sensitivity to 0.6%.

Refaat, Tamer F.↗

Oxygen Generation from Carbon Dioxide for Advanced Life Support

The partial electrochemical reduction of carbon dioxide (CO2) using ceramic oxygen generators (COGs) is well known and widely studied. However, complete reduction of metabolically produced CO2 (into carbon and oxygen) has the potential of reducing oxygen storage weight for life support if the oxygen can be recovered. Recently, the University of Florida devel- oped novel ceramic oxygen generators employing a bilayer elec- trolyte of gadolinia-doped ceria and erbia-stabilized bismuth ox- ide (ESB) for NASA's future exploration of Mars. The results showed that oxygen could be reliably produced from CO2 at temperatures as low as 400 C. The strategy discussed here for advanced life support systems employs a catalytic layer com- bined with a COG cell so that CO2 is reduced all the way to solid carbon and oxygen without carbon buildup on the COG cell and subsequent deactivation.

Bishop, Sean↗

Maintaining Adequate Carbon Dioxide Washout for an Advanced Extravehicular Mobility Unit

Over the past several years, NASA has realized tremendous progress in technology development that is aimed at the production of an Advanced Extravehicular Mobility Unit (AEMU). Of the many functions provided by the spacesuit and portable life support subsystem within the AEMU, delivering breathing gas to the astronaut along with removing the carbon dioxide (CO2) remains one of the most important environmental functions that the AEMU can control. Carbon dioxide washout is the capability of the ventilation flow in the spacesuit helmet to provide low concentrations of CO2 to the crew member to meet breathing requirements. CO2 washout performance is a critical parameter needed to ensure proper and sufficient designs in a spacesuit and in vehicle applications such as sleep stations and hygiene compartments. Human testing to fully evaluate and validate CO2 washout performance is necessary but also expensive due to the levied safety requirements. Moreover, correlation of math models becomes challenging because of human variability and movement. To supplement human CO2 washout testing, a breathing capability will be integrated into a suited manikin test apparatus to provide a safe, lower cost, stable, easily modeled alternative to human testing. Additionally, this configuration provides NASA Johnson Space Center (JSC) the capability to evaluate CO2 washout under off-nominal conditions that would otherwise be unsafe for human testing or difficult due to fatigue of a test subject. Testing has been under way in-house at JSC and analysis has been initiated to evaluate whether the technology provides sufficient performance in ensuring that the CO2 is removed sufficiently and the ventilation flow is adequate for maintaining CO2 washout in the AEMU spacesuit helmet of the crew member during an extravehicular activity. This paper will review recent CO2 washout testing and analysis activities, testing planned in-house with a spacesuit simulator, and the associated analytical work along with insights from the medical aspect on the testing.

Chullen, Cinda↗

System study of the carbon dioxide observational platform system (CO-OPS): Project overview

The resulting options from a system study for a near-space, geo-stationary, observational monitoring platform system for use in the Department of Energy's (DOE) National Carbon Dioxide Observational Platform System (CO-OPS) on the greenhouse effect are discussed. CO-OPS is being designed to operate continuously for periods of up to 3 months in quasi-fixed position over most global regional targets of interest and could make horizon observations over a land-sea area of circular diameter up to about 600 to 800 statute miles. This affords the scientific and engineering community a low-cost means of operating their payloads for monitoring the regional parameters they deem relevant to their investigations of the carbon dioxide greenhouse effect at one-tenth the cost of most currently utilized comparable remote sensing techniques.

Stephens, J. Briscoe↗

Carbon dioxide and water vapor production at rest and during exercise. A report on data collection for the Crew and Thermal Systems Division

The current environmental control device in the shuttle uses lithium hydroxide (LiOH) filter canisters to remove carbon dioxide (CO2) from the cabin air, requiring several bulky filter canisters that can only be used once and must be changed frequently. To alleviate a stowage problem and decrease launch weight, the Crew and Thermal Systems Division (CTSD) at the NASA Johnson Space Center has been researching a system to be used on future shuttle missions. This system uses two beds of solid amine material to absorb CO2 and water, later desorbing them to space vacuum. In this way the air scrubbing medium is regenerable and reusable. To identify the efficacy of this regenerable CO2 removal system (RCRS), CTSD began investigations in the shuttle mockup. The purpose of this investigation was to support the CTSD program by determining mean levels of carbon dioxide and water vapor production in normal, healthy males and females age-matched with the astronaut corps. Subjects' responses were measured at rest and during exercise at intensity levels equivalent to normal shuttle operation activities. The results were used to assess the adjustments made to RCRS and are reported as a reference for future investigations in shuttle environmental control.

Lee, Stuart M. C.↗

Time Course of Effects of Carbon Dioxide Exposure on Physical and Cognitive Performance in a Simulated Surface Extravehicular Activity Contingency Scenario

INTRODUCTION Carbon dioxide (CO 2 ) is a metabolic byproduct produced by humans that must be scrubbed from the atmosphere by environmental control and life support systems in space vehicles and spacesuits to prevent buildup. Current nominal CO 2 limits are set by NASA Standard 3001, however, limits during contingency situations are not specified. The purpose of this study was to characterize and quantify the physiological, cognitive, and self-assessed symptom and performance metrics as a function of inspired CO 2 (P I CO 2 ) during a simulated 1-hour contingency lunar EVA scenario in virtual reality (VR). METHODS Fifteen healthy subjects completed 7 simulated EVA scenarios walking on a passive treadmill for one hour breathing dry, ambient air mixed with added CO 2 in a blind, counterbalanced manner (P I CO 2 : 0, 5, 10, 15, 20, 25, 30 mmHg) simulating a 2.0 km contingency EVA walkback to a habitat on the lunar surface in the event of a CO 2 scrubber malfunction. Subjects were immersed in a Lunar VR environment and asked to maintain their walking speed between 2.1 km/h and an upper limit individually calibrated to a fixed metabolic workload of 1.3 L/min of O 2 consumption, and performed periodic cognitive tasks and continuous cardiopulmonary measurements. Self-assessments of symptoms and task performance were measured via verbal Likert-scale survey at the onset of the walkback and at 10-minute intervals thereafter. RESULTS The time course of cardiopulmonary, cognitive, and self-reported responses at each level of P I CO 2 will be presented. All 15 subjects were able to complete the 1-hr walk back task at all CO 2 levels. Physiological responses were rapid, typically within 1 to 5 minutes. No effects of time were detected for cognitive measures. Symptomatic ratings of headache, shortness of breath, and fatigue demonstrated a time-course development, reaching asymptote after 40 minutes of CO 2 exposure. DISCUSSION These findings will inform the posture of risk associated with CO 2 exposure on human health and performance during microgravity and planetary surface operations, This will help inform decisions related to space suit and environmental life support hardware requirements and EVA operational limits for contingency extravehicular activity (EVA) scenarios.

carbon dioxide↗