Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

SENSEI: Direct-Detection Results on sub-GeV Dark Matter from a New Skipper CCD

In this work, we present the first direct-detection search for sub-GeV dark matter using a new ~2-gram high-resistivity Skipper CCD from a dedicated fabrication batch that was optimized for dark matter searches. Using 24 days of data acquired in the MINOS cavern at the Fermi National Accelerator Laboratory, we measure the lowest rates in silicon detectors of events containing one, two, three, or four electrons, and achieve world-leading sensitivity for a large range of sub-GeV dark matter masses. Data taken with different thicknesses of the detector shield suggest a correlation between the rate of high-energy tracks and the rate of single-electron events previously classified as “dark current.” We detail key characteristics of the new Skipper CCDs, which augur well for the planned construction of the ~100-gram SENSEI experiment at SNOLAB.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results on low-mass weakly interacting massive particles from an 11 kg d target exposure of DAMIC at SNOLAB

We present constraints on the existence of weakly interacting massive particles (WIMPs) from a 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $\sigma_{\chi-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_{\chi}$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_{\chi}$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.

WIMP search, Dark Matter, DAMIC, SNOLAB↗

Smart Readout of Nondestructive Image Sensors with Single Photon-Electron Sensitivity

Image sensors with nondestructive charge readout provide single-photon or single-electron sensitivity, but at the cost of long readout times. We present a smart readout technique to allow the use of these sensors in visible light and other applications that require faster readout times. The method optimizes the readout noise and time by changing the number of times pixels are read out either statically, by defining an arbitrary number of regions of interest in the array, or dynamically, depending on the charge or energy of interest in the pixel. This technique is tested in a Skipper CCD showing that it is possible to obtain deep subelectron noise, and therefore, high resolution of quantized charge, while dynamically changing the readout noise of the sensor. These faster, low noise readout techniques show that the skipper CCD is a competitive technology even where other technologies such as electron multiplier charge coupled devices, silicon photo multipliers, etc. are currently used. This technique could allow skipper CCDs to benefit new astronomical instruments, quantum imaging, exoplanet search and study, and quantum metrology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Direct-Detection Results on Sub-GeV Dark Matter Using the SENSEI Detector at SNOLAB

Here, we present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. We employ a bias-mitigation technique of hiding approximately 46% of our total data and aggressively mask images to remove backgrounds. Given a total exposure after masking of 100.72 gram-days from well-performing sensors, we observe 55 two-electron events, 4 three-electron events, and no events containing 4–10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our “hot-pixel” mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of an EMCCD Camera for Calibration of Hard X-Ray Telescopes

Recent technological innovations now make it feasible to construct hard x-ray telescopes for space-based astronomical missions. Focusing optics are capable of improving the sensitivity in the energy range above 10 keV by orders of magnitude compared to previously used instruments. The last decade has seen focusing optics developed for balloon experiments and they will soon be implemented in approved space missions such as the Nuclear Spectroscopic Telescope Array (NuSTAR) and ASTRO-H. The full characterization of x-ray optics for astrophysical and solar imaging missions, including measurement of the point spread function (PSF) as well as scattering and reflectivity properties of substrate coatings, requires a very high spatial resolution, high sensitivity, photon counting and energy discriminating, large area detector. Novel back-thinned Electron Multiplying Charge-Coupled Devices (EMCCDs) are highly suitable detectors for ground-based calibrations. Their chip can be optically coupled to a microcolumnar CsI(Tl) scintillator via a fiberoptic taper. Not only does this device exhibit low noise and high spatial resolution inherent to CCDs, but the EMCCD is also able to handle high frame rates due to its controllable internal gain. Additionally, thick CsI(Tl) yields high detection efficiency for x-rays. This type of detector has already proven to be a unique device very suitable for calibrations in astrophysics: such a camera was used to support the characterization of the performance for all NuSTAR optics. Further optimization will enable similar cameras to be improved and used to calibrate x-ray telescopes for future space missions. In this paper, we discuss the advantages of using an EMCCD to calibrate hard x-ray optics. We will illustrate the promising features of this detector solution using examples of data obtained during the ground calibration of the NuSTAR telescopes performed at Columbia University during 2010/2011. Finally, we give an outlook on ongoing development and optimizations, such as the use of single photon counting mode to enhance spectral resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The MIDNA application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${\mu\nu}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Here, sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

1/f noise↗

Skipper-in-CMOS: Nondestructive Readout With Subelectron Noise Performance for Pixel Detectors

The Skipper-in-CMOS image sensor integrates the nondestructive readout capability of skipper charge coupled devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode (PPD) in a CMOS imaging process while taking advantage of in-pixel signal processing. This allows both single photon counting as well as high frame rate readout through highly parallel processing. The first results obtained from a ${15} \times {15}~\mu $ m2 pixel cell of a Skipper-in-CMOS sensor fabricated in Tower Semiconductor’s commercial 180-nm CMOS image sensor process are presented. Measurements confirm the expected reduction of the readout noise with the number of samples down to deep subelectron noise of $0.15\text {e}^ - $ , demonstrating the charge transfer operation from the PPD and the single photon counting operation when the sensor is exposed to light. This article also discusses new testing strategies employed for its operation and characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray detection for small satellites with a commercial CMOS sensor at room temperature

Recently CMOS (complementary metal-oxide-semiconductor) sensors have progressed to a point where they may offer improved performance in imaging x-ray detection compared to the CCDs often used in x-ray satellites. We demonstrate x-ray detection in the soft x-ray band (250-1700 eV) by a commercially available back-illuminated Sony IMX290LLR CMOS sensor using the Advanced Photon Source at the Argonne National Laboratory. Additionally, while operating the device at room temperature, we measure energy resolutions (FWHM) of 47 eV at 250 eV and and 77 eV 1700 eV which are comparable to the performance of the Chandra ACIS and the Suzaku XIS. Furthermore, we demonstrate that the IMX290LLR can withstand radiation up to 17.1 krad, making it suitable for use on spacecraft in low earth orbit.

47 OTHER INSTRUMENTATION↗

Development of CCD Cameras for Soft X-ray Imaging at the National Ignition Facility

The Static X-Ray Imager (SXI) is a National Ignition Facility (NIF) diagnostic that uses a CCD camera to record time-integrated X-ray images of target features such as the laser entrance hole of hohlraums. SXI has two dedicated positioners on the NIF target chamber for viewing the target from above and below, and the X-ray energies of interest are 870 eV for the “soft” channel and 3 – 5 keV for the “hard” channels. The original cameras utilize a large format back-illuminated 2048 x 2048 CCD sensor with 24 micron pixels. Since the original sensor is no longer available, an effort was recently undertaken to build replacement cameras with suitable new sensors. Three of the new cameras use a commercially available front-illuminated CCD of similar size to the original, which has adequate sensitivity for the hard X-ray channels but not for the soft. For sensitivity below 1 keV, Lawrence Livermore National Laboratory (LLNL) had additional CCDs back-thinned and converted to back-illumination for use in the other two new cameras. In this paper we describe the characteristics of the new cameras and present performance data (quantum efficiency, flat field, and dynamic range) for the front- and back-illuminated cameras, with comparisons to the original cameras.

National Ignition Facility, X-ray diagnostic, X-ra↗

The DESI instrument control systems: status and early testing

The Dark Energy Spectroscopic Instrument (DESI) is a new instrument currently under construction for the Mayall 4-m telescope at Kitt Peak National Observatory. It will consist of a wide-field optical corrector with a 3.2 degree diameter field of view, a focal plane with 5,000 robotically controlled fiber positioners and 10 fiber-fed broad-band spectrographs. The DESI Instrument Control System (ICS) coordinates fiber positioner operations, interfaces to the Mayall telescope control system, monitors operating conditions, reads out the 30 spectrograph CCDs and provides observer support and data quality monitoring. In this paper, we summarize the ICS design, review the current status of the project and present results from a multi-stage test plan that was developed to ensure the system is fully operational by the time the instrument arrives at the observatory in 2019.

79 ASTRONOMY AND ASTROPHYSICS↗

Light emission efficiency and imaging performance of Gd{sub 2}O{sub 2}S:Eu powder scintillator under x-ray radiography conditions

Purpose: To evaluate Gd{sub 2}O{sub 2}S:Eu powder phosphor as a radiographic image receptor and to compare it to phosphors often used in radiography. Gd{sub 2}O{sub 2}S:Eu is nonhygroscopic, emitting red light with decay time close to that of Gd{sub 2}O{sub 2}S:Tb. Methods: The light intensity emitted per unit of x-ray exposure rate (absolute luminescence efficiency) was measured for laboratory prepared screens with coating thicknesses of 33.1, 46.4, 63.1, 78.3, and 139.8 mg/cm{sup 2} and tube voltages ranging from 50 to 140 kVp. Parameters related to image quality such as the modulation transfer function (MTF) and the detective quantum efficiency (DQE) were also experimentally examined. In addition, a previously validated Monte Carlo code was used to estimate intrinsic x-ray absorption and optical properties, as well as the MTF and the Swank factor (I) of the Gd{sub 2}O{sub 2}S:Eu scintillators. Results: Gd{sub 2}O{sub 2}S:Eu light intensity was found higher than that of single CsI:Tl crystal for tube voltages up to 100 kVp. The MTF and the DQE were found to be comparable with those of Gd{sub 2}O{sub 2}S:Tb and CsI:Tl screens. MTF estimated by the Monte Carlo code was found very close to the experimental MTF values. Gd{sub 2}O{sub 2}S:Eu showed peak emission in the wavelength range 620-630 nm. Its emission spectrum was excellently matched to various optical detectors (photodiodes, photocathodes, CCDs, and CMOS) employed in flat panel detectors. Conclusions: Gd{sub 2}O{sub 2}S:Eu is an efficient phosphor potentially well suited to radiography and especially to some digital detectors sensitive to red light.

36 MATERIALS SCIENCE↗

Analysis of combustion chamber deposit growth on temperature swing thermal barrier coatings in a spark ignition engine

Temperature swing thermal barrier coatings (TBCs) have the potential to improve efficiency and performance through thermal management of the combustion chamber. However, the effects of combustion chamber deposits (CCDs) on the surface of the TBCs are unclear. Therefore, this paper analyzes the impact of CCD formation on a temperature swing TBC. A piston and a heat flux probe coated with a novel material are installed in a single-cylinder research engine at a low-load condition for 62.5 h to promote CCD growth. Every 12.5 h, the performance at a knock limited condition is assessed and thermophysical property measurements on the heat flux probe are performed. Net thermal efficiency increased by 0.4% absolute after 12.5 h relative to the baseline condition, but further CCD growth caused a dithering of efficiency between the 12.5 h and baseline points. The KLSA retarded consistently throughout this period. As a result, external property measurements with the coated heat flux probe showed an improvement in the thermophysical properties of the TBC/CCD layer.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Dark Energy Spectrometer (DESpec): A Multi-Fiber Spectroscopic Upgrade of the Dark Energy Camera and Survey for the Blanco Telescope

We describe an initiative to build and use the Dark Energy Spectrometer (DESpec), a wide-field spectroscopic survey instrument for the Blanco 4-meter telescope at Cerro Tololo Inter-American Observatory (CTIO) in Chile. A new system with about 4000 robotically positioned optical fibers will be interchangeable with the CCD imager of the existing Dark Energy Camera (DECam), accessing a field of view of 3.8 square degrees in a single exposure. The proposed instrument will be operated by CTIO and available for use by the astronomy community. Our collaboration proposes to use DESpec to conduct a wide, deep spectroscopic survey to study Dark Energy, sharing the survey products with the community, while providing community access to fibers in parallel with survey observations. In a survey of ~350 nights, the DESpec collaboration proposes to obtain spectroscopic redshifts for ~8 million galaxies over 5000 sq. deg. selected from precision imaging from the Dark Energy Survey (DES). This Dark Energy Spectroscopic Survey will advance our knowledge of cosmic expansion and structure growth significantly beyond that obtainable with imaging-only surveys. Since it adds a spectroscopic third dimension to the same sky as DES, the world’s largest and deepest photometric survey, DESpec will enable a powerful array of new, increasingly precise techniques to discriminate among alternative explanations of cosmic acceleration, such as Dark Energy and Modified Gravity. In the 2020 decade, a wider-area spectroscopic survey will enhance the science reach of the next-generation imaging project, LSST, by providing spectroscopy for tens of millions of galaxies and QSO’s over its 15,000-20,000 square degree survey area. DESpec will create a comprehensive, three dimensional, critically-sampled map of large scale cosmic structure – a database encompassing the “cosmic web” of galaxies and clusters over the entire, deeply-imaged southern sky – over most of cosmic history. DESpec will take advantage of the substantial hardware infrastructure recently built for DECam to achieve excellent science at low cost and low technical and schedule risk. It will be mounted in the DECam prime focus cage with its hexapod positioning system (recently installed on the Blanco Telescope) and will share the four largest DECam optical corrector elements. It will be routinely interchangeable with the DECam CCD imager and preserve f/8 secondary capability, to allow flexible use of the telescope. The robotically positioned optical fibers will feed 10 relatively simple, high-throughput spectrometers outfitted with existing, spare, red-sensitive, science-grade DECam CCDs. An Atmospheric Dispersion Compensator similar to existing designs can be accommodated in the existing DECam filter slot. Examples that meet requirements for all major subsystems are in existing or highly developed instruments, showing that cost, technical, and schedule risks are manageable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Go Pink! The Effect of Secondary Quanta on Detective Quantum Efficiency

Photons are never directly observable. Consequently, we often use photoelectric detectors (eg CCDs) to record associated photoelectrons statistically. Nonetheless, it is an implicit goal of radiographic detector designers to achieve the maximum possible detector efficiency1. In part the desire for ever higher efficiency has been due to the fact that detectors are far less expensive than associated accelerator facilities (e.g. DARHT and PHERMEX2). In addition, higher efficiency detectors often have better spatial resolution. Consequently, the optimization of the detector, not the accelerator, is the system component with the highest leverage per dollar. In recent years, imaging scientists have adopted the so-called Detective Quantum Efficiency, or DQE as a summary measure of detector performance. Unfortunately, owing to the complex nature of the trade-space associated with detector components, and the natural desire for simplicity and low(er) cost, there has been a recent trend in Los Alamos to focus only on the zerofrequency efficiency, or DQE(0), when designing such systems. This narrow focus leads to system designs that neglect or even ignore the importance of high-spatial-frequency image components. In this paper we demonstrate the significant negative impact of these design choices on the Noise Power Spectrum1 (NPS) and recommend a more holistic approach to detector design. Here we present a statistical argument which indicates that a very large number (>20) of secondary quanta (typically visible light and/or recorded photo-electrons) are needed to take maximum advantage of the primary quanta (typically x-rays or protons) which are available to form an image. Since secondary particles come in bursts, they are not independent. In short, we want to maximize the pink nature of detector noise at DARHT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The SLD Vertex Detector Upgrade (VXD3) and a Study of $b\bar{b}g$ Events [Thesis]

This thesis presents a variety of work concerning the design, construction and use of the SLD's vertex detector. SLD's pioneering 120 Mpixel vertex detector, VXD2, was replaced by VXD3, a 307Mpixel CCD vertex detector in January 1996. The motivation for the up-grade detector and its subsequent construction and testing are described in some detail. This work represents the collaborative work of a large number of people. My work was mainly carried out at EEV on the testing of the CCDs and subsequent ladders. VXD3 was commissioned during the 1996 SLD run and performed very close to design specifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ghost Images in DECam [Slides]

This presentation concludes that ghost images are all understood. Amplitude is about what is expected for CCDs with 10%-15% reflectivity, filters with 1%-1.5% reflectivity. Scattered light from bright stars off the field has multiple causes: a) Unblocked edges of filters. We definitely want to add baffles to all filters to block light around edges. b) Inside shutter wall. We want to either paint the wall with aeroglaze black (or equivalent) or add some baffles. c) Filter cage or some other surface located above u/Y filter cassette. Probably need to examine visually before deciding on a course of action.

79 ASTRONOMY AND ASTROPHYSICS↗

A multi-channel cryogenic low-noise skipper-CCD readout ASIC

• Skipper CCDs provide exceptionally low noise useful for dark matter detection• MIDNA ASIC enables scaled cryogenic Skipper CCD readout• Noise performance proven to specification at room temperature with CCD• Liquid nitrogen measurements show functionality with more to come• Future development will integrate more sensitive signals and averaging capability

England, Troy↗