Search NASA⌕ Search

SEARCH · Search NASA

Results for “CMOS technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Dynamically Reconfigurable Data Readout of Pixel Detectors for Automatic Synchronization with Data Acquisition Systems

Reconfigurable detectors with dynamically selectable sensing and readout modes are highly desirable for implementing edge computing as well as enabling advanced imaging techniques such as foveation. The concept of a camera system capable of simultaneous passive imaging and dynamic ranging in different regions of the detector is presented. Such an adaptive-autonomous detector with both spatial and temporal control requires programmable window of exposure (time frames), ability to switch between readout modes such as full-frame imaging and zero-suppressed data, modification of the number of pixel data bits and independent programmability for distinct detector regions. In this work, a method is presented for seamlessly changing time frames and readout modes without data corruption while still ensuring that the data acquisition system (DAQ) does not need to stop and resynchronize at each change of setting, thus avoiding significant dead time. Data throughput is maximized by using a minimum unique data format, rather than lengthy frame headers, to differentiate between consecutive frames. A data control and transmitter (DCT) synchronizes data transfer from the pixel to the periphery, reconfigures the data to transmit it serially off-chip, while providing optimized decision support based on a DAQ definable mode. Measurements on a test structure demonstrate that the DCT can operate at 1 GHz in a 65 nm LP CMOS process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evolution of LIBS technology to mobile instrumentation for expediting firearm-related investigations at the laboratory and the crime scene

Gunshot residue (GSR) is one of the few forensic disciplines that lack accurate screening techniques. This study proposes using a mobile LIBS instrument to detect inorganic GSR and compares performance to a previously validated laboratory instrument. The mobile LIBS is designed with advanced configurations specifically for on-site GSR analysis, including a CMOS detector and a sampling chamber that holds up to six typical GSR collection devices with separate gas flow ports to prevent cross-contamination. A significant novelty of the portable instrument is its image magnification, which allows quick searching and visualization of GSR particle morphology. The single-particle imaging and elemental composition capability is one of a kind and offers superior confirmatory features for GSR. The mobile LIBS performance was evaluated for residues collected from the hands of shooters (100 samples) and non-shooters (200 background samples), analyzed sequentially by the mobile instrument and then the laboratory instrument. Accuracies better than 98.8% were obtained by both instruments, demonstrating their suitability for trace IGSR detection from skin specimens. Implementation of this methodology is anticipated to drastically speed up response times (i.e., from several hours per sample by standard SEM-EDS practice to a few minutes by LIBS). The screening methods can be easily incorporated into workflows to improve decision-making processes at the crime scene and laboratory settings, reduce backlogs, and improve case management.

47 OTHER INSTRUMENTATION↗

Programmable photonic integrated meshes for modular generation of optical entanglement links

Abstract Large-scale generation of quantum entanglement between individually controllable qubits is at the core of quantum computing, communications, and sensing. Modular architectures of remotely-connected quantum technologies have been proposed for a variety of physical qubits, with demonstrations reported in atomic and all-photonic systems. However, an open challenge in these architectures lies in constructing high-speed and high-fidelity reconfigurable photonic networks for optically-heralded entanglement among target qubits. Here we introduce a programmable photonic integrated circuit (PIC), realized in a piezo-actuated silicon nitride (SiN)-in-oxide CMOS-compatible process, that implements an N × N Mach–Zehnder mesh (MZM) capable of high-speed execution of linear optical transformations. The visible-spectrum photonic integrated mesh is programmed to generate optical connectivity on up to N = 8 inputs for a range of optically-heralded entanglement protocols. In particular, we experimentally demonstrated optical connections between 16 independent pairwise mode couplings through the MZM, with optical transformation fidelities averaging 0.991 ± 0.0063. The PIC’s reconfigurable optical connectivity suffices for the production of 8-qubit resource states as building blocks of larger topological cluster states for quantum computing. Our programmable PIC platform enables the fast and scalable optical switching technology necessary for network-based quantum information processors.

47 OTHER INSTRUMENTATION↗

Bottom-up fabrication of 2D Rydberg exciton arrays in cuprous oxide

Solid-state platforms provide exceptional opportunities for advancing on-chip quantum technologies by enhancing interaction strengths through coupling, scalability, and robustness. Cuprous oxide (Cu 2 O) has recently emerged as a promising medium for scalable quantum technology due to its high-lying Rydberg excitonic states, akin to those in hydrogen atoms. To harness these nonlinearities for quantum applications, the confinement dimensions must match the Rydberg blockade size, which can reach several microns in Cu 2 O. Using a CMOS-compatible growth technique, this study demonstrates the bottom-up fabrication of site-selective arrays of Cu 2 O microparticles. We observed Rydberg excitons up to the principal quantum number n = 5 within these Cu 2 O arrays on a quartz substrate and analyzed the spatial variation of their spectrum across the array, showing robustness and reproducibility on a large chip. These results lay the groundwork for the deterministic growth of Cu 2 O around photonic structures, enabling substantial light-matter interaction on integrated photonic platforms and paving the way for scalable, on-chip quantum devices.

36 MATERIALS SCIENCE↗

Piezo-optomechanical cantilever modulators for VLSI visible photonics

Visible-wavelength very large-scale integration photonic circuits have a potential to play important roles in quantum information and sensing technologies. The realization of scalable, high-speed, and low-loss photonic mesh circuits depends on reliable and well-engineered visible photonic components. Here, we report a low-voltage optical phase shifter based on piezo-actuated mechanical cantilevers, fabricated on a CMOS compatible, 200 mm wafer-based visible photonics platform. We show linear phase and amplitude modulation with 6 V π cm in differential operation, −1.5 to −2 dB insertion loss, and up to 40 dB contrast in the 700–780 nm range. By adjusting selected cantilever parameters, we demonstrate a low-displacement and a high-displacement device, both exhibiting a nearly flat frequency response from DC to a peak mechanical resonance at 23 and 6.8 MHz respectively, which, through resonant enhancement of Q ∼ 40, further decreases the operating voltage down to 0.15 V π cm.

Dong, Mark↗

Fault handling schemes in electronic systems with specific application to radiation tolerance and VLSI design

Naturally occurring space radiation particles can produce transient and permanent changes in the electrical properties of electronic devices and systems. In this work, the transient radiation effects on DRAM and CMOS SRAM were considered. In addition, the effect of total ionizing dose radiation of the switching times of CMOS logic gates were investigated. Effects of transient radiation on the column and cell of MOS dynamic memory cell was simulated using SPICE. It was found that the critical charge of the bitline was higher than that of the cell. In addition, the critical charge of the combined cell-bitline was found to be dependent on the gate voltage of the access transistor. In addition, the effect of total ionizing dose radiation on the switching times of CMOS logic gate was obtained. The results of this work indicate that, the rise time of CMOS logic gates increases, while the fall time decreases with an increase in total ionizing dose radiation. Also, by increasing the size of the P-channel transistor with respect to that of the N-channel transistor, the propagation delay of CMOS logic gate can be made to decrease with, or be independent of an increase in total ionizing dose radiation. Furthermore, a method was developed for replacing polysilicon feedback resistance of SRAMs with a switched capacitor network. A switched capacitor SRAM was implemented using MOS Technology. The critical change of the switched capacitor SRAM has a very large critical charge. The results of this work indicate that switched capacitor SRAM is a viable alternative to SRAM with polysilicon feedback resistance.

Attia, John Okyere↗

Performance Support Tools for Space Medical Operations

The early Constellation space missions are expected to have medical capabilities very similar to those currently on the Space Shuttle and International Space Station (ISS). For Crew Exploration Vehicle (CEV) missions to ISS, medical equipment will be located on ISS, and carried into CEV in the event of an emergency. Flight Surgeons (FS) on the ground in Mission Control will be expected to direct the Crew Medical Officer (CMO) during medical situations. If there is a loss of signal and the crew is unable to communicate with the ground, a CMO would be expected to carry out medical procedures without the aid of a FS. In these situations, performance support tools can be used to reduce errors and time to perform emergency medical tasks. Human factors personnel at Johnson Space Center have recently investigated medical performance support tools for CMOs on-orbit, and FSs on the ground. This area of research involved the feasibility of Just-in-time (JIT) training techniques and concepts for real-time medical procedures. In Phase 1, preliminary feasibility data was gathered for two types of prototype display technologies: a hand-held PDA, and a Head Mounted Display (HMD). The PDA and HMD were compared while performing a simulated medical procedure using ISS flight-like medical equipment. Based on the outcome of Phase 1, including data on user preferences, further testing was completed using the PDA only. Phase 2 explored a wrist-mounted PDA, and compared it to a paper cue card. For each phase, time to complete procedures, errors, and user satisfaction were captured. Information needed by the FS during ISS mission support, especially for an emergency situation (e.g. fire onboard ISS), may be located in many different places around the FS s console. A performance support tool prototype is being developed to address this issue by bringing all of the relevant information together in one place. The tool is designed to include procedures and other information needed by a FS during an emergency, as well as procedures and information to be used after the emergency is resolved. Several walkthroughs of the prototype with FSs have been completed within a mockup of an ISS FS console. Feedback on the current tool design as well as recommendations for existing ISS FS displays were captured.

Byrne, Vicky E.↗

Enhanced Switching Reliability of Hf 0.5 Zr 0.5 O 2 Ferroelectric Films Induced by Interface Engineering

Ferroelectric materials have been widely researched for applications in memory and energy storage. Among these materials and benefiting from their excellent chemical compatibility with complementary metal–oxide–semiconductor (CMOS) devices, hafnia-based ferroelectric thin films hold great promise for highly scaled semiconductor memories, including nonvolatile ferroelectric capacitors and transistors. However, variation in the switched polarization of this material during field cycling and a limited understanding of the responsible mechanisms have impeded their implementation in technology. Here, we show that ferroelectric Hf 0.5 Zr 0.5 O 2 (HZO) capacitors that are nearly free of polarization “wake-up”─a gradual increase in switched polarization as a function of the number of switching cycles─can be achieved by introducing ultrathin HfO 2 buffer layers at the HZO/electrodes interface. High-resolution transmission electron microscopy (HRTEM) reveals crystallite sizes substantially greater than the film thickness for the buffer layer capacitors, indicating that the presence of the buffer layers influences the crystallization of the film (e.g., a lower ratio of nucleation rate to growth rate) during postdeposition annealing. This evidently promotes the formation of a polar orthorhombic (O) phase in the as-fabricated buffer layer samples. Synchrotron X-ray diffraction (XRD) reveals the conversion of the nonpolar tetragonal (T) phase to the polar orthorhombic (O) phase during electric field cycling in the control (no buffer) devices, consistent with the polarization wake-up observed for these capacitors. The extent of T–O transformation in the nonbuffer samples is directly dependent on the duration over which the field is applied. Here these results provide insight into the role of the HZO/electrodes interface in the performance of hafnia-based ferroelectrics and the mechanisms driving the polarization wake-up effect.

36 MATERIALS SCIENCE↗

SS focused technology: Gateways and NOS's

The extensions and enhancements of the fiber optic data bus technology supported by the Space Station Focused Technology Program are discussed. This includes the operating software for the network called the Network Operating System (NOS); gateways and bridges for multiple network topologies; and very large scale topology implimentations to shrink the size and power of the Bus Interface Unit (BIU) down to more manageable dimensions. CMOS is being investigated for the lower speed (parallel) logic. Gallium arsendide is being studied for the high speed (serial) logic.

Hartenstein, R.↗

Commercial Sensory Survey Radiation Testing Progress Report

The NASA Electronic Parts and Packaging (NEPP) Program Sensor Technology Commercial Sensor Survey task is geared toward benefiting future NASA space missions with low-cost, short-duty-cycle, visible imaging needs. Such applications could include imaging for educational outreach purposes or short surveys of spacecraft, planetary, or lunar surfaces. Under the task, inexpensive commercial grade CMOS sensors were surveyed in fiscal year 2007 (FY07) and three sensors were selected for total ionizing dose (TID) and displacement damage dose (DDD) tolerance testing. The selected sensors had to meet selection criteria chosen to support small, low-mass cameras that produce good resolution color images. These criteria are discussed in detail in [1]. This document discusses the progress of radiation testing on the Micron and OmniVision sensors selected in FY07 for radiation tolerance testing.

Micron↗

NASA Tech Briefs, Februrary 2013

Topics covered include: Measurements of Ultra-Stable Oscillator (USO) Allan Deviations in Space; Gaseous Nitrogen Orifice Mass Flow Calculator; Validation of Proposed Metrics for Two-Body Abrasion Scratch Test Analysis Standards; Rover Low Gain Antenna Qualification for Deep Space Thermal Environments; Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip; Measuring and Estimating Normalized Contrast in Infrared Flash Thermography; Spectrally and Radiometrically Stable, Wideband, Onboard Calibration Source; High-Reliability Waveguide Vacuum/Pressure Window; Methods of Fabricating Scintillators With Radioisotopes for Beta Battery Applications; Magnetic Shield for Adiabatic Demagnetization Refrigerators (ADR); CMOS-Compatible SOI MESFETS for Radiation-Hardened DC-to-DC Converters; Silicon Heat Pipe Array; Adaptive Phase Delay Generator; High-Temperature, Lightweight, Self-Healing Ceramic Composites for Aircraft Engine Applications; Treatment to Control Adhesion of Silicone-Based Elastomers; High-Temperature Adhesives for Thermally Stable Aero-Assist Technologies; Rockballer Sample Acquisition Tool; Rock Gripper for Sampling, Mobility, Anchoring, and Manipulation; Advanced Magnetic Materials Methods and Numerical Models for Fluidization in Microgravity and Hypogravity; Data Transfer for Multiple Sensor Networks Over a Broad Temperature Range; Using Combustion Synthesis to Reinforce Berms and Other Regolith Structures; Visible-Infrared Hyperspectral Image Projector; Three-Axis Attitude Estimation With a High-Bandwidth Angular Rate Sensor Change_Detection.m; AGATE: Adversarial Game Analysis for Tactical Evaluation; Ionospheric Simulation System for Satellite Observations and Global Assimilative; Modeling Experiments (ISOGAME); An Extensible, User- Modifiable Framework for Planning Activities; Mission Operations Center (MOC) - Precipitation Processing System (PPS) Interface Software System (MPISS); Automated 3D Damaged Cavity Model Builder for Lower Surface Acreage Tile on Orbiter; Mixed Linear/Square-Root Encoded Single-Slope Ramp Provides Low-Noise ADC with High Linearity for Focal Plane Arrays; RUSHMAPS: Real-Time Uploadable Spherical Harmonic Moment Analysis for Particle Spectrometers; Powered Descent Guidance with General Thrust-Pointing Constraints; X-Ray Detection and Processing Models for Spacecraft Navigation and Timing; and Extreme Ionizing-Radiation-Resistant Bacterium

Source record↗

Commercial Sensor Survey Fiscal Year 2009 master compendium radiation test report

The NASA Electronic Parts and Packaging (NEPP) Program Sensor Technology Commercial Sensor Survey task is geared toward benefiting future NASA space missions with low-cost, short-duty-cycle, visible-wavelength imaging needs. Such applications could include imaging for educational outreach purposes or short surveys of spacecraft, planetary, or lunar surfaces. Under the task, inexpensive, low-power, commercial grade CMOS sensors were surveyed in fiscal year 2007 (FY07), and three sensors were selected and tested for total ionizing dose (TID) and displacement damage dose (DDD) tolerance in fiscal year 2008 (FY08). The selected sensors had to meet selection criteria chosen to support small, low-mass cameras that produce good resolution color images. The commercial CMOS sensors tested under the task in FY08 showed very promising response to typical outreach and survey camera TID and DDD levels. In fiscal year 2009 (FY09), the survey was broadened to include two additional, similar sensor products. This compendium provides results for all radiation testing performed on the Micron and OmniVision sensors that were selected for radiation tolerance testing in FY08 and FY09.

Thorbourn, Dennis O.↗

High-speed architecture for the decoding of trellis-coded modulation

Since 1971, when the Viterbi Algorithm was introduced as the optimal method of decoding convolutional codes, improvements in circuit technology, especially VLSI, have steadily increased its speed and practicality. Trellis-Coded Modulation (TCM) combines convolutional coding with higher level modulation (non-binary source alphabet) to provide forward error correction and spectral efficiency. For binary codes, the current stare-of-the-art is a 64-state Viterbi decoder on a single CMOS chip, operating at a data rate of 25 Mbps. Recently, there has been an interest in increasing the speed of the Viterbi Algorithm by improving the decoder architecture, or by reducing the algorithm itself. Designs employing new architectural techniques are now in existence, however these techniques are currently applied to simpler binary codes, not to TCM. The purpose of this report is to discuss TCM architectural considerations in general, and to present the design, at the logic gate level, or a specific TCM decoder which applies these considerations to achieve high-speed decoding.

Osborne, William P.↗

The future of computing beyond Moore’s Law

Moore’s Law is a techno-economic model that has enabled the information technology industry to double the performance and functionality of digital electronics roughly every 2 years within a fixed cost, power and area. Advances in silicon lithography have enabled this exponential miniaturization of electronics, but, as transistors reach atomic scale and fabrication costs continue to rise, the classical technological driver that has underpinned Moore’s Law for 50 years is failing and is anticipated to flatten by 2025. Here, this article provides an updated view of what a post-exascale system will look like and the challenges ahead, based on our most recent understanding of technology roadmaps. It also discusses the tapering of historical improvements, and how it affects options available to continue scaling of successors to the first exascale machine. Lastly, this article covers the many different opportunities and strategies available to continue computing performance improvements in the absence of historical technology drivers. This article is part of a discussion meeting issue ‘Numerical algorithms for high-performance computational science’.

97 MATHEMATICS AND COMPUTING↗

Electrically Isolating Thermally Coupled Device for Noise Suppression of Circuits in Deep Space

Mixed mode rad hard avionics Systems on a Chip (SoC) designed for deep space applications such as Europa orbiters and Europa Landers will require data isolation circuits to block noise. This paper presents the simulation performance for a novel rad hard SOI CMOS compatible thermal transducer used for on-chip data isolation in SoC. The research presented involves the use of commercially available computer aided design tools to model the transient electrothermal behavior of the transducer. Both one- and two-dimensional analyses of a prototype thermal transducer were performed. Results indicate that thermal-based data isolator technology can pass a data bit in under a microsecond and, as a measurement of feasibility, I(exp 2)C bus specifications can be met.

Mantooth, A.↗

A Hybrid Transmitter With Voltage-Mode SST Preemphasis and Current-Mode Transmitter Equalization Capable of Operating at 77 K in DUNE

The Deep Underground Neutrino Experiment (DUNE) requires that the front-end transmitters operate at cryogenic temperature and drive 25–35 m long twin-axial (twinax) cables. Here, to compensate the frequency-dependent channel loss over the long cables and alleviate the de-emphasizing of the low-frequency signal magnitude, a hybrid of a current-mode (CM) transmitter equalization (TXEQ) and a voltage-mode (VM) preemphasis is proposed. The TXEQ employs a finite-impulse response (FIR) filter to boost the high-frequency components while de-emphasizing the low-frequency signal magnitude, thereby flattening the overall channel frequency response and reducing the intersymbol interference (ISI). The VM preemphasis is proposed to further mitigate ISI by boosting the high-frequency portion without degrading the signal magnitude, allowing for high signal swing. The main driver utilizes VM source-series-terminated (SST) output stages, which offers higher signal swing and better power efficiency than the conventional CM logic (CML) drivers. To ensure the lifetime and reliability at cryogenic temperature, the transmitter is implemented in a 65-nm CMOS process operating at 1.1 V of supply voltage and employing transistors with larger than minimum lengths. Silicon measurement results at 77 K have validated the proposed approaches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗