Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPACTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Current Status of the Development of a Transportable and Compact VLBI System by NICT and GSI

MARBLE (Multiple Antenna Radio-interferometer for Baseline Length Evaluation) is under development by NICT and GSI. The main part of MARBLE is a transportable VLBI system with a compact antenna. The aim of this system is to provide precise baseline length over about 10 km for calibrating baselines. The calibration baselines are used to check and validate surveying instruments such as GPS receiver and EDM (Electro-optical Distance Meter). It is necessary to examine the calibration baselines regularly to keep the quality of the validation. The VLBI technique can examine and evaluate the calibration baselines. On the other hand, the following roles are expected of a compact VLBI antenna in the VLBI2010 project. In order to achieve the challenging measurement precision of VLBI2010, it is well known that it is necessary to deal with the problem of thermal and gravitational deformation of the antenna. One promising approach may be connected-element interferometry between a compact antenna and a VLBI2010 antenna. By measuring repeatedly the baseline between the small stable antenna and the VLBI2010 antenna, the deformation of the primary antenna can be measured and the thermal and gravitational models of the primary antenna will be able to be constructed. We made two prototypes of a transportable and compact VLBI system from 2007 to 2009. We performed VLBI experiments using theses prototypes and got a baseline length between the two prototypes. The formal error of the measured baseline length was 2.7 mm. We expect that the baseline length error will be reduced by using a high-speed A/D sampler.

Ishii, Atsutoshi↗

Spontaneous Cracking in Unfired Magnesia Compacts Upon Standing in Air

Analytical-grade magnesium oxide powder without binder was compressed hydrostatically to 50,000 lb. per sq. in. to form compacts. When exposed to moist air immediately after pressing, these compacts developed irregularly shaped cracks. Controlled tests, in which these compacts were exposed for various lengths of time to various atmospheres, indicated that in general water vapor, carbon dioxide, and residual stresses had to be present if cracking was to occur. The probable cause of the cracking was the formation of a less dense and mechanically weak basic carbonate of magnesium at crystallite surface points of high stress concentration which developed during the compacting. The adsorption of dry CO2 at such sites prevented subsequent delayed fracture.

Davies, Myron O.↗

Dynamic Stall Suppression Using Combustion-Powered Actuation (COMPACT)

Retreating blade stall is a well-known phenomenon that limits rotorcraft speed, maneuverability, and efficiency. Airfoil dynamic stall is a simpler problem, which demonstrates many of the same flow phenomena. Combustion Powered Actuation (COMPACT) is an active flow control technology, which at the outset of this work, had been shown to mitigate static and dynamic stall at low Mach numbers. The attributes of this technology suggested strong potential for success at higher Mach numbers, but such experiments had never been conducted. The work detailed in this report documents a 3-year effort focused on assessing the effectiveness of COMPACT for dynamic stall suppression at freestream conditions up to Mach 0.5. The work done has focused on implementing COMPACT on a high-lift rotorcraft airfoil: the VR-12. This selection was made in order to ensure that any measured benefits are over and above the capabilities of state-of-the-art high-lift rotorcraft airfoils. The detailed Computational Fluid Dynamics (CFD) simulations, wind-tunnel experiments, and system-level modeling conducted have shown the following: (1) COMPACT, in its current state of development, is capable of reducing the adverse effects of deep dynamic stall at Mach numbers up to 0.4; (2) The two-dimensional (2D) CFD results trend well compared to the experiments; and (3) Implementation of the CFD results into a system-level model suggest that significant rotor-level benefits are possible.

Matalanis, Claude G.↗

The Second LBA Calibrator Survey of Southern Compact Extragalactic Radio Sources – LCS2

We present the second catalogue of accurate positions and correlated flux densities for 1100 compact extragalactic radio sources that were not observed before 2008 at high angular resolution. The catalogue spans the declination range [-90◦, -30◦] and was constructed from 19 24-h VLBI observing sessions with the Australian Long Baseline Array at 8.3 GHz. The catalogue presents the final part of the program that was started in 2008. The goals of that campaign were (1) to extend the number of compact radio sources with precise coordinates and measure their correlated flux densities, which can be used for phase referencing very long baseline interferometry (VLBI) and Atacama Large Millimeter/submillimeter Array (ALMA) observations, geodetic VLBI, search for sources with significant offsets with respect to Gaia positions, and space navigation; (2) to extend the complete flux-limited sample of compact extragalactic sources to the Southern hemisphere; and (3) to investigate the parsec-scale properties of sources from the high-frequency AT20G survey. The median uncertainty of the source positions is 3.5 mas. As a result of this VLBI campaign, the number of compact radio sources south of declination -40◦ that have measured VLBI-correlated flux densities and positions known to milliarcsecond accuracy has increased by over a factor of 6.

Petrov, Leonid↗

A Compact Dual-Band Bowtie Antenna for RF and ISM bands Operation

Traditionally, bowtie antennas have been known to exhibit wide impedance characteristics, omnidirectional radiation patterns, and linear polarization. There is a broad range of applications from medical imaging, archaeological survey, and Ground Penetrating Radar (GPR) to trackers and sensor networks where wideband bowtie antenna designs are required for their operations. Broadening the bandwidth of bowtie antenna requires widening the flare angle of the bowtie arms, which consequently results in a large surface area that may not be suitable for space-constrained applications. Moreover, drawback attributes of the wideband bowtie designs feature inconsistent radiation pattern across the bandwidth and low signal-to-noise (SNR) ratios. As it is known, the SNR would be improved in dual- or multi-band antennas due to their reduced bandwidth. To this end, dual-band/multi-band antennas are preferred over wideband antennas in applications where more than a single frequency of interest is present. Previously, a two-port double-dipole elements was reported, whose arms were orthogonally interleaved to facilitate operation in both the standard WLAN frequency bands (J. M. Steyn and et. al, Progress in Electromagnetic Research, Vol. – 10 pp. 151-161). Even though the antenna is not very compact it does exhibit good cross-polarization, moderate gain in both frequency bands. Another dual-band bowtie antenna which excites two bands using a single transmission line was reported (Wen Chao Zheng and et. al, IEEE Trans. Antennas propag., 2014). The design was compact and did not need multi-port feeding network. In this paper, a dual-band compact bowtie antenna operating at 900 MHz (RF band) and 2.45 GHz (ISM band) using a single excitation port is introduced. It is printed on a 1.54mm thick dielectric substrate (εr = 3.38). The antenna consists of two sets of bowtie arms, a microstrip transmission line to feed the bowtie arms, and a ground plane acting as a reflector to partially reduce the back radiation. One of the bowtie arms of each frequency is printed on the top layer and the other arm, which is mirror imaged, is printed on the bottom layer of the substrate. The length of the bowtie controls the resonance frequency of the antenna and the flare angle controls the bandwidth of the antenna. The microstrip transmission line, connected to a 50 Ω SMA probe, feeds the bowtie antenna. The compact antenna can be used for both RF and ISM band applications. The bowtie arms at the lower frequency band are miniaturized by elongating their electrical lengths. The influence of miniaturizing the bowtie arms and the supporting partial ground plane is observed in the reduced peak gain and degraded front-to-back ratio. These are partly neutralized using four quarter-wave choke-slots in the ground plane with two on each side of the feeding transmission line. The proposed antenna is numerically investigated and finalized by the finite-element based full-wave EM solver, ANSYS HFSS. The miniaturization has reduced the ground plane size by ~45% and the arms size by ~41%. In addition to the size reduction benefits, the antenna shows reasonable peak gain and front-to-back ratio in both the bands. The corresponding results will be presented and discussed at the conference.

Saininad Naik↗

Microbial Characterization of Heat Melt Compaction for Treatment of Space Generated Solid Wastes

One treatment process in development for solid waste management in space has been the Trash Compaction Processing System (TCPS). Human space mission wastes typically contain large percentages of contaminated wet solid waste. The Heat Melt Compactor (HMC) is being developed to be a multi-function means of water recovery, volume reduction, and the making safe of contaminant-rich trash with the potential for waste stabilization and/or sterilization. To determine the efficacy of the HMC treatment to kill microorganisms in solid waste and remain biologically stable, testing was conducted on three tiles produced by HMC-Gen 2 at Ames Research Center. Samples were shipped to Kennedy Space Center to test for microbial viability after compaction, determine the bio-stability of the HMC disks during storage (43 days), and assess potential airborne contaminate microbial growth on surfaces at low and high humidity conditions. In addition to the products of solid waste processing technologies, there is a concern that the crew might come into contact with hardware surfaces that have been contaminated by microorganisms during waste processing. The extent of microbial surface contamination of waste processing hardware was determined by surface sample swabbing and analysis for total bacterial and yeast counts and cultivable counts of aerobic and anaerobic bacteria, spore-forming bacteria, and fungi. Results indicate that trash processing increased bacterial counts on the surfaces of the compacter. All but one biological indicator spore strip imbedded in the HMC produced tiles were negative for growth after incubation for five days indicating effective sterilization through the heat melt compaction process. Analysis of core samples as well as surface growth of tiles inoculated with Aspergillus niger fungal spores incubated at three levels of humidity indicate that HMC created tiles did not support the proliferation of bacterial and fungal growth.

Mary E Hummerick↗

Compact laser source with frequency modulators generating multiple lines

A compact laser source and a single sideband modulator used therein is disclosed. The compact laser source includes a seed laser and one or more channels, with each channel generating one or more output laser beams having corresponding different wavelengths. The compact laser source can be formed in whole or in part on a single optical motherboard to thereby minimize space and power requirements. By employing the disclosed single sideband modulator, harmonics in the generated output laser beams can be minimized. The compact laser source finds application in an atom interferometer (AI) system, which may be used to measure gravity, acceleration, or rotation of the AI system.

Lentine, Anthony L.↗

Refractory high entropy alloy compact heat exchanger

Several innovative technologies, including pressure-drop minimization, advanced refractory high entropy alloys, and advanced manufacturing can provide a compact heat exchanger that extends the state-of-the-art heat-exchanger operating range. The compact heat exchanger can reduce pressure drop losses by 100 to 500%, while retaining most of the heat transfer. The compact heat exchanger can be fabricated from refractory high entropy alloys that have favorable corrosion, thermal fatigue, and creep properties at high temperatures and pressures. Therefore, the compact heat exchanger using high entropy alloys can operate at >800° C. and 80 bars.

Kustas, Andrew↗

Compact System for Operating and Decommissioned Reactor Used Fuel Management - 17243

Most nuclear power plants in operation today were designed with limited wet storage for their discharged used nuclear fuel (UNF), predicated on the assumption that either recycling or geologic storage would be available within the reactor's lifetime. While that has proven to be the case in some countries such as France with its recycling, it has not for most. In the USA, dry storage of UNF at the plant site at an Independent Spent Fuel Storage Installation (ISFSI) has since the mid-1980s been the primary mode of interim storage so that the plant can off-load its UNF from the pools at the power plants. Initially the space reserved for the ISFSI at a reactor site was based on the assumption that the Department of Energy (DOE) would be transporting that UNF to a geological repository site, such as Yucca Mountain, by 1998. However, due to the delay in the opening of any geological repository the utilities are running out of space on their existing ISFSIs for additional UNF dry storage systems. Since plants prefer to keep their ISFSIs inside the protected area of the plant, options for expanding the ISFSI are becoming limited. At the same time, increasing the capacity of the dry storage systems is also not an option in most cases as the dry storage systems have almost reached their capacity limits with the 37 PWR or 89 BWR fuel assembly canister designs. For plants that have announced plans to shut down, their main priority is to off-load the UNF from the pool to dry storage at an ISFSI so that they can proceed to 'Safe store' or other storage options, and start their decommissioning process as soon as possible. Thus, keeping the size of the ISFSI compact is very important for safety, security and economics. This paper will describe the details of a reduced footprint version of AREVA TN's NUHOMS{sup R} System that addresses the need for maximizing ISFSI capacity. This system not only offers a compact design that stores nearly double the number of UNF assemblies in the same space, it also offers superior radiation protection to the workers and public. In addition, it offers unmatched protection against beyond design basis (BDB) events like the tsunami at Fukushima in Japan, the earthquake at North Anna site, tornadoes and manmade attacks such as the 9/11 attack on the World Trade Center in New York. It also includes significant enhancement for a robust Canister Evolved Safety Program for Aging Management. The utilities in the USA are currently using dry storage systems with canisters of different diameter, different length, and different weights. The fuel assemblies that are stored in these canisters are also different in their fuel types (PWR or BWR),different fuel parameters like burnups, enrichments, and cooling times and different storage orientations in the storage overpacks like horizontal or vertical. The compact version of AREVA TN's NUHOMS{sup R} System offers a 'Universal' Storage Overpack which is designed to accept all these different design dry storage canister available in the industry. As UNF storage continues to drives the industry towards innovations that address the need for consolidated storage, compact ISFSIs and aging management, this new evolution of the AREVA TN NUHOMS{sup R} system offers a significant leap forward in addressing all of these challenges. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The German product quality control of the compacted metallic nuclear waste - 15311

The treatment and safe disposal of spent nuclear fuel is a key challenge of nuclear energy utilization and has to be accomplished regardless the future nuclear of electricity production or phase-out policies. Until June 2005 approx. 6662 tons of spent fuel from German nuclear power plants was sent to the La Hague (France) and Sellafield (UK) plants for reprocessing. An equivalent amount of nuclear waste compounds has contractually to be returned to Germany, which is currently in progress. The returnable waste streams comprise mainly highly-active vitrified waste containing a major part of fission products and actinides, and intermediate-active super-compacted metallic waste containing reprocessed fuel element's structural materials and some technological waste from the reprocessing process itself. Shearing and dissolution of spent fuel leaves scraps of fuel metal cladding, the end-pieces and spacers which are contaminated, activated and irradiating from their life in a reactor core. In fact, this metallic intermediate level radioactive waste makes up a bit more than half of the total volume of the reprocessed waste. At La Hague the metallic waste is super-compacted. Several, typically eight, compacted discs are stacked in a stainless steel container, named CSD-C as for 'Colis Standard de Dechets Compactes'. 4104 containers of such CSD-Cs in 152 transport/storages casks have to be returned to Germany. Each one of them has to be checked and quality certified for its conformity with German national product specifications and acceptance criteria by independent national product quality control inspectors (PKS). The residue package documentation has to be complete and the characterization methods have to be comprehensive. Due to the heterogeneity of metallic waste the characterization and control of its properties is very complex. The nuclear characterization is performed by means of non-destructive measurements, where only a few key nuclides are measured directly. In fact, the proper calculation of the whole nuclear inventory relies on numerous supplementary simulations. The measurement and calculation methodology is scrutinized by PKS in detail and key points are benchmarked with our own simulations for the sake of an independent nuclear inventory declaration check. With respect to the vast amount of documentation and parameters, which have to be checked and verified, PKS had to optimize their checking procedures. For this purpose dedicated proof tools have been developed that shall be applied for selected indicative cross-checks of the relevant parameters. This contribution is dedicated to the procedure of quality control by PKS and examples of actually performed computational verifications of declared nuclear inventory. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial examination of fuel compacts and triso particles from the US AGR-2 irradiation test - 18443

Post-irradiation examination was completed on two as-irradiated compacts from the US Advanced Gas Reactor Fuel Development and Qualification Program's second irradiation test. These compacts were selected for examination due to indications that they may have contained particles that released cesium due to a failed or defective SiC layer. The coated particles were recovered from these compacts by electrolytic deconsolidation of the surrounding graphitic matrix in nitric acid. The leach-burn-leach (LBL) process was used to dissolve and analyze exposed metallic elements (actinides and fission products), and each particle was individually surveyed for relative cesium retention with the Irradiated Microsphere Gamma Analyzer (IMGA). Data from IMGA and LBL examinations provided information on fission product release during irradiation and whether any specific particles had below-average retention that could be related to coating layer defects or radiation-induced degradation. A few selected normal-retention particles and six with abnormally-low cesium inventory were analyzed using x-ray tomography to produce three-dimensional images of the internal coating structure. Four of the low-cesium particles had obviously damaged or degraded SiC, and x-ray imaging was able to guide subsequent grinding and polishing to expose the regions of interest for analysis by optical and electron microscopy. Additional particles from each compact were also sectioned and examined to study the overall radiation-induced microstructural changes in the kernel and coating layers. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Post-irradiation Heating Tests of As-Irradiated AGR-3/4 TRISO Fuel Compacts

Four post-irradiation heating tests of fuel compacts from the U.S. Advanced Gas Reactor (AGR)-3/4 irradiation experiment were completed. In addition to tristructural isotropic (TRISO)-coated driver fuel, each compact contained designed-to-fail (DTF) particles with fuel kernels coated only in pyrocarbon so as to simulate exposed kernels. Tests at 1600/1700°C, 1400°C, and 1200°C were performed to measure fission product release as a function of time and temperature. Silver release was highest in the 1200°C test, supporting the observation that silver release rates are highest in the 1100–1300°C range. Compared to tests of AGR-1 compacts with no exposed kernels, the Cs-134 and Kr-85 releases were noticeably higher in AGR-3/4. The exposed kernels’ contributions to Eu and Sr release are inconclusive, due to the difficulty in distinguishing among the combined effects of higher irradiation temperatures in these particular AGR-3/4 compacts, the presence of the DTF particles, and the Fuel Accident Condition Simulator (FACS) test temperatures. These data can be used to make inferences about fission product retention in exposed kernels as a function of time and temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

All-in-one bipolar electrode: A new concept for compact and efficient water electrolyzers

Highly compact and efficient proton exchange membrane electrolyzer cells (PEMECs) are strongly desired for commercializing hydrogen production. Here, a novel concept of all-in-one bipolar electrode (AIOBE) is proposed for high-efficiency and compact PEMECs with the help of 3D printing and sputtering coating. AIOBE ideally integrated catalyst layer (CL)/gas diffusion layer/bipolar plate/current distributor/gasket, which significantly reduced component quantity on the cathode side of PEMECs from 5 to 1, cut down on part weight and volume, and drastically accelerated the fabrication and maintenance processes. Moreover, AIOBE with the micro-scale flat surface and nano-scale rough CL provided an ultralow ohmic resistance (~100 mOhm cm 2 ) and a high catalyst utilization. Finally, AIOBE delivered a practical voltage of 1.62 V and a high energy efficiency of 91% at 1000 mA/cm 2 , and its mass activity (4.48 A/mg Pt ) was 14 times higher than conventional PEMECs. In conclusion, this work provides a new route for developing highly compact electrochemical devices, such as fuel cells, electrolyzers for N 2 reduction and CO 2 conversion, and many more.

3D printing↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade (SOG) home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Physical Compact Model for Three-Terminal SONOS Synaptic Circuit Element

A well-posed physics-based compact model for a three-terminal silicon–oxide–nitride–oxide–silicon (SONOS) synaptic circuit element is presented for use by neuromorphic circuit/system engineers. Based on technology computer aided design (TCAD) simulations of a SONOS device, the model contains a nonvolatile memristor with the state variable QM representing the memristor charge under the gate of the three-terminal element. By incorporating the exponential dependence of the memristance on QM and the applied bias V for the gate, the compact model agrees quantitatively with the results from TCAD simulations as well as experimental measurements for the drain current. The compact model is implemented through VerilogA in the circuit simulation package Cadence Spectre and reproduces the experimental training behavior for the source–drain conductance of a SONOS device after applying writing pulses ranging from –12 V to +11 V, with an accuracy higher than 90%.

42 ENGINEERING↗

Investigation of Characteristics of Alloys Manufactured by Shock-Wave Compaction on Bimetallic Fe-Cu Powders

The study deals with bulk nanostructured alloys manufactured by the method of shock-wave compaction on bimetallic Fe–Cu powders. The results presented suggest a possible efficient application of shock-wave compaction for the production of high-density compacts from bimetallic powders. The structure and parameters of bimetallic Fe–Cu powders formed by the method of electric wire explosion are investigated. An analysis of the structure and hardness of the bulk nanostructured alloys manufactured from these powders is performed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Graph-based Compact Modeling (GCM) of CMOS transistors for efficient parameter extraction: A machine learning approach

Parameter extraction of compact transistor models is an expensive process, heavily relying on engineering knowledge and experience. To automate such a process, we propose a novel approach, Graph-based Compact Model (GCM), that integrates physical modeling and data-driven learning. GCM utilizes Graph Neural Networks (GNNs) to establish the model structure, while retaining the physicality in compact models. Here, we implement our GCM in Verilog-A to support circuit simulations. As demonstrated with an academic 7 nm FinFET PDK, the new approach automatically generates a GCM model within a minute, and achieves excellent accuracy and efficiency in SPICE.

42 ENGINEERING↗