Chaotic Time Series Analysis Method Developed for Stall Precursor Identification in High-Speed Compressors

A new technique for rotating stall precursor identification in high-speed compressors has been developed at the NASA Lewis Research Center. This pseudo correlation integral method uses a mathematical algorithm based on chaos theory to identify nonlinear dynamic changes in the compressor. Through a study of four various configurations of a high-speed compressor stage, a multistage compressor rig, and an axi-centrifugal engine test, this algorithm, using only a single pressure sensor, has consistently predicted the onset of rotating stall.

Source record↗

Inlet-Compressor Analysis Performed Using Coupled Computational Fluid Dynamics Codes

A thorough understanding of dynamic interactions between inlets and compressors is extremely important to the design and development of propulsion control systems, particularly for supersonic aircraft such as the High-Speed Civil Transport (HSCT). Computational fluid dynamics (CFD) codes are routinely used to analyze individual propulsion components. By coupling the appropriate CFD component codes, it is possible to investigate inlet-compressor interactions. The objectives of this work were to gain a better understanding of inlet-compressor interaction physics, formulate a more realistic compressor-face boundary condition for time-accurate CFD simulations of inlets, and to take a first step toward the CFD simulation of an entire engine by coupling multidimensional component codes. This work was conducted at the NASA Lewis Research Center by a team of civil servants and support service contractors as part of the High Performance Computing and Communications Program (HPCCP).

Cole, Gary L.↗

Optical Flow-Field Techniques Used for Measurements in High-Speed Centrifugal Compressors

The overall performance of a centrifugal compressor depends on the performance of the impeller and diffuser as well as on the interactions occurring between these components. Accurate measurements of the flow fields in each component are needed to develop computational models that can be used in compressor design codes. These measurements must be made simultaneously over an area that covers both components so that researchers can understand the interactions occurring between the two components. Optical measurement techniques are being used at the NASA Lewis Research Center to measure the velocity fields present in both the impeller and diffuser of a 4:1 pressure ratio centrifugal compressor operating at several conditions ranging from design flow to surge. Laser Doppler Velocimetry (LDV) was used to measure the intrablade flows present in the impeller, and the results were compared with analyses obtained from two three-dimensional viscous codes. The development of a region of low throughflow velocity fluid within this high-speed impeller was examined and compared with a similar region first observed in a large low-speed centrifugal impeller at Lewis. Particle Image Velocimetry (PIV) is a relatively new technique that has been applied to measuring the diffuser flow fields. PIV can collect data rapidly in the diffuser while avoiding the light-reflection problems that are often encountered when LDV is used. The Particle Image Velocimeter employs a sheet of pulsed laser light that is introduced into the diffuser in a quasi-radial direction through an optical probe inserted near the diffuser discharge. The light sheet is positioned such that its centerline is parallel to the hub and shroud surfaces and such that it is parallel to the diffuser vane, thereby avoiding reflections from the solid surfaces. Seed particles small enough to follow the diffuser flow are introduced into the compressor at an upstream location. A high-speed charge-coupled discharge (CCD) camera is synchronized to the laser pulse rate; this allows it to capture images of seed particle position that are separated by a small increment in time. A crosscorrelation of a particle's position in two consecutive images provides an estimate of flow velocity and direction. Multiple image pairs obtained in rapid succession at a particular flow condition provide enough measurements for statistical significance. PIV provides simultaneous velocity measurements over the entire plane that is illuminated by the light sheet instead of at a single point, as is the case when LDV is used. PIV has a further advantage in that the laser light pulse can be triggered by an external source such as a high-response pressure transducer. This feature will allow PIV to synchronize flow imaging to physical phenomena such as rotating stall or stall precursor waves. We hope that this technique can be used to obtain images of the flow field during and just prior to stall.

Skoch, Gary J.↗

8- by 6-Foot Supersonic Wind Tunnel Compressor Inspected

The NASA Glenn Research Center's 8- by 6-Foot Supersonic Wind Tunnel (8 6 SWT) is NASA's only transonic propulsion wind tunnel. The test section speed range is between Mach 0.25 and 2.0. The 9- by 15-Foot Low-Speed Wind Tunnel (9 15 LWST), which has a speed range from 0 to 175 mph, is housed in the return leg of the 8 6 SWT and uses the same compressor. The 8 6 SWT uses a large, seven-stage axial flow compressor to drive the air through the tunnel. The compressor is 17 ft in diameter and is rated at 1600 m3 (56,600 ft3) of air/sec. It is driven by three electric motors with a combined horsepower of 87,000. A close examination of this compressor was performed in 2001, the first time since February of 1966.

Krupar, Martin J.↗

Centrifugal Compressor Surge Controlled

It shows the variation in compressor mass flow with time as the mass flow is throttled to drive the compressor into surge. Surge begins where wide variations in mass flow occur. Air injection is then turned on to bring about a recovery from the initial surge condition and stabilize the compressor. The throttle is closed further until surge is again initiated. Air injection is increased to again recover from the surge condition and stabilize the compressor.

Skoch, Gary J.↗

Toward a Real-Time Measurement-Based System for Estimation of Helicopter Engine Degradation Due to Compressor Erosion

This paper presents a preliminary demonstration of an automated health assessment tool, capable of real-time on-board operation using existing engine control hardware. The tool allows operators to discern how rapidly individual turboshaft engines are degrading. As the compressor erodes, performance is lost, and with it the ability to generate power. Thus, such a tool would provide an instant assessment of the engine s fitness to perform a mission, and would help to pinpoint any abnormal wear or performance anomalies before they became serious, thereby decreasing uncertainty and enabling improved maintenance scheduling. The research described in the paper utilized test stand data from a T700-GE-401 turboshaft engine that underwent sand-ingestion testing to scale a model-based compressor efficiency degradation estimation algorithm. This algorithm was then applied to real-time Health Usage and Monitoring System (HUMS) data from a T700-GE-701C to track compressor efficiency on-line. The approach uses an optimal estimator called a Kalman filter. The filter is designed to estimate the compressor efficiency using only data from the engine s sensors as input.

Litt, Jonathan S.↗

Rotary-Wing Relevant Compressor Aero Research and Technology Development Activities at Glenn Research Center

Technical challenges of compressors for future rotorcraft engines are driven by engine-level and component-level requirements. Cycle analyses are used to highlight the engine-level challenges for 3000, 7500, and 12000 SHP-class engines, which include retention of performance and stability margin at low corrected flows, and matching compressor type, axial-flow or centrifugal, to the low corrected flows and high temperatures in the aft stages. At the component level: power-to-weight and efficiency requirements impel designs with lower inherent aerodynamic stability margin; and, optimum engine overall pressure ratios lead to small blade heights and the associated challenges of scale, particularly increased clearance-to-span ratios. The technical challenges associated with the aerodynamics of low corrected flows and stability management impel the compressor aero research and development efforts reviewed herein. These activities include development of simple models for clearance sensitivities to improve cycle calculations, full-annulus, unsteady Navier-Stokes simulations used to elucidate stall, its inception, and the physics of stall control by discrete tip-injection, development of an actuator-duct-based model for rapid simulation of nonaxisymmetric flow fields (e.g., due inlet circumferential distortion), advanced centrifugal compressor stage development and experimentation, and application of stall control in a T700 engine.

Welch, Gerard E.↗

Calibration of a V-Cone for Low Mass Flows For Small Core Compressor Research

Advancements in core compressor technologies are necessary for next generation, high Overall Pressure Ratio (OPR) turbofan engines. High pressure compressors (HPCs) for future engines are being designed with exit corrected mass flow rates less than 2.25 kg/s (5 lbm/s). In order to accurately measure the performance of these advanced designs, high accuracy measurements are needed in test facilities. The W7 High Speed Multistage Axial Compressor Facility at NASA Glenn Research Center has been used to acquire data for advanced compressor designs. This facility utilizes an advanced differential pressure flow meter called a V-Cone. The facility has historically tested components with physical mass flow rates in the range of 27 to 45 kg/s (60 to 100 lbm/s). As such, when the V-Cone was calibrated prior to installation, the calibrations focused on higher mass flow rates, and uncertainties in that regime range from 0.5% to 0.85%. However, for low mass flow rates under 9 kg/s (20 lbm/s), expected in tests of advanced high OPR HPCs rear stages, the uncertainties of the V-Cone exceed 2.5%. To address this, using a method similar to that utilized by the National Institute of Standards and Technology, an array of Critical Flow Venturi Nozzles (CFVs) was installed in the W7 test section and used to calibrate the V-Cone in 0.5 kg/s (1 lbm/s) increments up to 10.5 kg/s (23 lbm/s). This effort details the measurements and uncertainties associated with this calibration which resulted in a final uncertainty of the V-Cone measurements under 1%.

Measurement Uncertainty↗

Method and apparatus for starting supersonic compressors

A supersonic gas compressor with bleed gas collectors, and a method of starting the compressor. The compressor includes aerodynamic duct(s) situated for rotary movement in a casing. The aerodynamic duct(s) generate a plurality of oblique shock waves for efficiently compressing a gas at supersonic conditions. A convergent inlet is provided adjacent to a bleed gas collector, and during startup of the compressor, bypass gas is removed from the convergent inlet via the bleed gas collector, to enable supersonic shock stabilization. Once the oblique shocks are stabilized at a selected inlet relative Mach number and pressure ratio, the bleed of bypass gas from the convergent inlet via the bypass gas collectors is effectively eliminated.

42 ENGINEERING↗

Compressor Selection and Equipment Sizing for Cold Climate Heat Pumps

In order to limit heating capacity degradation at -25 C (-13 F) ambient to 25%, compared to the nominal rating point capacity at 8.3 C (47 F), an extensive array of design and sizing options were investigated, based on fundamental equipment system modeling and building energy simulation. Sixteen equipment design options were evaluated in one commercial building and one residential building, respectively in seven cities. The energy simulation results were compared to three baseline cases: 100% electric resistance heating, a 9.6 HSPF single-speed heat pump unit, and 90% AFUE gas heating system. The general recommendation is that variable-speed compressors and tandem compressors, sized such that their rated heating capacity at a low speed matching the building design cooling load, are able to achieve the capacity goal at low ambient temperatures by over-speeding, for example, a home with a 3.0 ton design cooling load, a tandem heat pump could meet this cooling load running a single compressor, while running both compressors to meet heating load at low ambient temperatures in a cold climate. Energy savings and electric resistance heat reductions vary with building types, energy codes and climate zones. Oversizing a heat pump can result in larger energy saving in a less energy efficient building and colder regions due to reducing electric resistance heating. However, in a more energy-efficient building or for buildings in warmer climates, one has to consider balance between reduction of resistance heat and addition of cyclic loss.

Building Energy Simulation↗

Refrigeration system having dual suction port compressor

A cooling system for appliances, air conditioners, and other spaces includes a compressor, and a condenser that receives refrigerant from the compressor. The system also includes an evaporator that receives refrigerant from the condenser. Refrigerant received from the condenser flows through an upstream portion of the evaporator. A first portion of the refrigerant flows to the compressor without passing through a downstream portion of the evaporator, and a second portion of the refrigerant from the upstream portion of the condenser flows through the downstream portion of the evaporator after passing through the upstream portion of the evaporator. The second portion of the refrigerant flows to the compressor after passing through the downstream portion of the evaporator. The refrigeration system may be configured to cool an appliance such as a refrigerator and/or freezer, or it may be utilized in air conditioners for buildings, motor vehicles, or other such spaces.

42 ENGINEERING↗

Cooling system having dual suction port compressor

A cooling system for appliances, air conditioners, and other spaces includes a compressor, and a condenser that receives refrigerant from the compressor. The system also includes an evaporator that receives refrigerant from the condenser. Refrigerant received from the condenser flows through an upstream portion of the evaporator. A first portion of the refrigerant flows to the compressor without passing through a downstream portion of the evaporator, and a second portion of the refrigerant from the upstream portion of the condenser flows through the downstream portion of the evaporator after passing through the upstream portion of the evaporator. The second portion of the refrigerant flows to the compressor after passing through the downstream portion of the evaporator. The refrigeration system may be configured to cool an appliance such as a refrigerator and/or freezer, or it may be utilized in air conditioners for buildings, motor vehicles, or other such spaces.

42 ENGINEERING↗

Cooling system with compressor bleed and ambient air for gas turbine engine

A cooling system for a turbine engine for directing cooling fluids from a compressor to a turbine blade cooling fluid supply and from an ambient air source to the turbine blade cooling fluid supply to supply cooling fluids to one or more airfoils of a rotor assembly is disclosed. The cooling system may include a compressor bleed conduit extending from a compressor to the turbine blade cooling fluid supply that provides cooling fluid to at least one turbine blade. The compressor bleed conduit may include an upstream section and a downstream section whereby the upstream section exhausts compressed bleed air through an outlet into the downstream section through which ambient air passes. The outlet of the upstream section may be generally aligned with a flow of ambient air flowing in the downstream section. As such, the compressed air increases the flow of ambient air to the turbine blade cooling fluid supply.

42 ENGINEERING↗

Mid-section of a can-annular gas turbine engine to introduce a radial velocity component into an air flow discharged from a compressor of the mid-section

A midframe portion (113) of a gas turbine engine (110) is provided, including a compressor section (112) with a last stage blade (124). The compressor section (112) is configured to introduce a radial velocity component into an air flow (111) such that the air flow is discharged from the compressor section (112) at a mixed direction based on a combined longitudinal velocity component and radial velocity component. The midframe portion (113) further includes a manifold (121) to directly couple the air flow from an outlet of the compressor section (112) to an inlet of a respective combustor head (118) of the gas turbine engine (110).

Rodriguez, Jose L.↗

Experimental Study to Characterize Performance of a Prototype Electrochemical Compressor

This paper reports experimental study to characterize performance of a prototype electrochemical hydrogen compressor, provided by Xergy INC. It describes the working mechanism and reports its measured electrochemical efficiency and isentropic compression efficiency. The experimental results demonstrate that the prototype compressor can pump hydrogen flow from 25 psia to 140 psia and deliver the flow rate as theory. The electrochemical efficiency was measured around 40%, and isentropic efficiency around 47%. Using two identical ECC compressors in parallel will reduce the current density and ohm loss, which can increase the isentropic efficiency to 67% with increased cost. Further improvements on the compressor are suggested, e.g. using more conductive membrane, etc.

Shen, Bo↗

Turbocharger systems and method to prevent compressor choke

Systems and methods are provided for a turbocharger compressor, where the system may comprise: an actuatable annular disk comprising choke slots therein; an outer annular disk comprising choke slots therein; and an actuator to rotate the actuatable annular disk relative to the outer annular disk to vary alignment of the choke slots of the actuatable annular disk and the outer annular disk. The actuator may be controlled by an engine controller responsive to operating conditions of the compressor and actuated to align choke slots. Alignment of the choke slots allows air to be drawn into the impeller effectively expanding the compressor flow capacity to prevent compressor choke.

42 ENGINEERING↗

Effects of Cold Temperature and Main Compressor Intercooling on Recuperator and Recompression Cycle Performance

<span>This study investigates the effects of cold supercritical CO2 (sCO2) temperatures, compressor inlet pressures, and main compressor intercooling on the efficiency and specific power of recompression sCO2 cycles. Reducing the cold sCO2 temperature increases the compressor inlet density, thus reducing required compression power and increasing cycle thermal efficiency. &nbsp;Similarly, main compressor intercooling improves the specific power of a recompression cycle, reducing sCO2 mass flow, cycle size and cost for a given power output, though it is also shown to lead to an internal pinch point in the low temperature recuperator. Strategies for remediation of internal pinch points for recuperators as well as for the main CO2 cooler and the flue gas cooler are discussed, and apply to recompression cycles for all sCO2 applications.&nbsp; Upfront consideration of these remediation strategies is essential to determine attainable sCO2 cycle operating conditions and component sizing requirements.</span>

White, Chuck↗

Zero-clearance ultra-high-pressure gas compressor

Gas compression system comprising a compression cylinder having a gas inlet, a compressed gas outlet, and one or more liquid transfer ports; a pump having a suction and a discharge; and a compressor liquid. The system also includes any of the following: a pressure intensifier having an inlet in flow communication with the pump and an outlet in flow communication with the compression cylinder; a feed eductor in flow communication with the discharge of the pump, with a reservoir containing a portion of the compressor liquid, and with the compression cylinder; a drain eductor in flow communication with the discharge of the pump, with the compression cylinder, and with a reservoir containing a portion of the compressor liquid; and a variable-volume compressor liquid accumulator in flow communication with the discharge of the pump.

Bhatt, Bharat Lajjaram↗