Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORROSION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Corrosion-Resistant Plug Materials for Geothermal Well Fluid Control

Conventional cements and plugs are challenged by corrosion in CO 2 -rich and extreme geothermal environments, due to the hostile chemistry and high temperatures. Thermite-based sealing and well intervention technologies are being applied in the oil and gas industry, combining the energy delivery capability of thermite materials with the sealing characteristics of low melt temperature alloys. The thermite reaction products (ceramics) and the sealing alloys used in these plugs both have very attractive corrosion properties, and their operating envelopes extend into geothermal conditions. Thermite plugs and platforms, without supplemental sealing materials, have been considered for nuclear waste isolation, carbon sequestration, and geothermal applications due to the geochemical stability of the ceramic product and its very high service temperature. This study addresses corrosion resistance of the thermite reaction products. A range of engineered thermite systems which yield thermite reaction products including pure aluminum oxide, feldspar, or aluminosilicate solid solutions (in addition to the iron produced in thermite reactions) was developed. These materials were evaluated for their strong acid resistance (pH 1), carbonate resistance (sodium carbonate) and thermal shock resistance (600 °C heating → cold water quenching repeated three times). Performance of different materials was evaluated based on the changes in mechanical properties, water-fillable porosity, phase changes under stress conditions. The aluminosilicate product exhibited very good corrosion resistance, both from material loss and strength perspectives, while the other products performed with varying degrees of stability. This paper presents the results of the thermite corrosion studies and describes the novel tools being deployed, and under development, to satisfy challenging barrier and intervention applications.

02 PETROLEUM↗

Real-time sensor measurements to evaluate impacts of load cycling on high-temperature fire-side corrosion in a PC boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Control Rod Malfunction at the NRAD Reactor

The neutron Radiography Reactor (NRAD) is a training, research, and isotope (TRIGA) reactor located at the INL. The reactor is normally shut down by the insertion of three control rods that drop into the core when power is removed from electromagnets. During a routine shutdown, indicator lights on the console showed that one of the control rods was not inserted. It was initially thought that the indicator lights were in error because of a limit switch that was out of adjustment. Through further testing, it was determined that the control rod did not drop when the scram switch was initially pressed. The control rod anomaly led to a six month shutdown of the reactor and an in depth investigation of the reactor protective system. The investigation looked into: scram switch operation, console modifications, and control rod drive mechanisms. A number of latent issues were discovered and corrected during the investigation. The cause of the control rod malfunction was found to be a buildup of corrosion in the control rod drive mechanism. The investigation resulted in modifications to equipment, changes to both operation and maintenance procedures, and additional training. No reoccurrences of the problem have been observed since corrective actions were implemented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

REPORT ON ELECTROCHEMICAL CORROSION TESTING FOR TANK 241-AN-106 USING 2009 SAMPLING CAMPAIGN GRAB SAMPLES

Based on an ENRAF waste surface measurement taken February 1, 2009, double-shell tank (DST) 24l-AN-l06 (AN-106) contained approximately 278.98 inches (793 kgal) of waste. A zip cord measurement from the tank on February 1, 2009, indicated a settled solids layer of 9l.7 inches in height (280 kgal). The supernatant layer in February 2009, by difference, was approximately 187 inches deep (514 kgal). Laboratory results from AN-l06 February 1, 2009 (see Table 2) grab samples indicated the supernatant was below the chemistry limit that applied at the time as identified in HNF-SD-WM-TSR-006, 'Tank Farms Technical Safety Requirements', Administrative Control (AC) 5.16, 'Corrosion Mitigation Controls.' The limits have since been removed from the Technical Safety Requirements (TSR) and are captured in OSD-T-15l-00007, 'Operating Specifications for the Double-Shell Storage Tanks.' Problem evaluation request WRPS-PER-2009-0218 was submitted February 9,2009, to document the finding that the supernatant chemistry for grab samples taken from the middle and upper regions of the supernatant was noncompliant with the chemistry control limits. The lab results for the samples taken from the bottom region of the supernatant met AC 5.16 limits.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stress Corrosion Evaluation of NiTiHf Alloy for the International Space Station Environmental Control and Life Support System

A stress corrosion evaluation was performed on NiTiHf alloy because this material is considered a bearing material candidate for the Environmental Control and Life Support System. Stressed round tensile specimens survived exposures to alternate pretreat, alternate brine, baseline pretreat, baseline brine, and 3.5% NaCl alternate immersion. Metallographic evaluations did not detect stress corrosion on exposed samples. The ultimate tensile strength values varied significantly for this material, which is common for bearing materials. This variation was observed on both, exposed and nonexposed specimens. The results of this work indicate that this material has potential applications as a bearing material.

International Space Station (ISS)↗

Development of a Thermodynamic Database for Corrosion in Chloride MSRs

Control of the salt redox condition is the salient method for corrosion inhibition in molten salts. For chloride salt-fueled molten salt reactors of primary concern is the U(IV)/U(III) ratio, influenced directly by the Cl2 activity in the salt. Although thermodynamic assessments of MSR-relevant salts abound, none have included consideration of UCl4 which is essential to correctly describe the salt redox condition. This work reports the assessment of the NaCl-KCl-MgCl2 base salt with UCl3-UCl4 and corrosion chlorides involving Cr, Fe, and Ni as minor components and the resultant thermodynamic models. The effort utilized available thermodynamic measurements and phase equilibria complemented by differential scanning calorimetry determinations of phase equilibria. Example calculations explore the temperature and composition space to understand its influence on corrosion. The foregoing models are incorporated into an update of the Molten Salt Thermal Properties Database – Thermochemical which is publicly available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Waste Chemistry Envelope for the Determination of Pitting Corrosion Susceptibility - 19554

Liquid radioactive wastes at the Hanford and Savannah River sites are stored in large underground carbon steel tanks. The high-level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks, will be required to be in service for times exceeding the initial intended life (i.e., greater than 60 years). Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. Administrative programs are in place to mitigate potential corrosion mechanisms and thereby maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. Waste chemistry and temperature control are the means by which corrosion degradation of the waste tanks is minimized. Chemistry controls are based on in-situ coupon tests, waste tank experience, and laboratory testing. These requirements comprise the technical standards for corrosion control. The standards are utilized then as guidelines for operational procedures. The present waste chemistry controls for the Hanford DSTs were established in the 1980's in response to tank failures caused by stress corrosion cracking (SCC) at the DOE Savannah River Site (SRS). Portions of the SRS chemistry limits, which were developed at the Savannah River National Laboratory (SRNL) were coupled with corrosion testing results from Pacific Northwest National Laboratories (PNNL) and adopted for corrosion control of the double-shell tank (DST) waste at the Hanford Site. Since that time, the temperatures of the waste in the DSTs have decreased to less than 50 deg. C in most cases as the radioactive material has decayed. As a consequence, new chemistry controls were formulated for SCC in 2010. This testing however, did not address that potential for pitting in the supernatant and at the liquid-air interface. Indeed, initial tests indicated that the inhibitor requirements for SCC would be insufficient for the prevention of pitting. In addition to lower waste temperatures, future retrieval and process changes may impact the DST waste chemistry. Initial projections suggest that the waste chemistry of the DSTs may shift to a broader range of pH and higher aggressive anion concentrations (e.g., chloride, sulfate, etc.) than the wastes that are presently stored. Additionally, processes within the vitrification facility may result in streams that are returned to the tank farm for evaporation. These streams may also contain high concentrations of aggressive species. SRNL investigated the propensity for pitting of the carbon steel waste tanks at current and projected DST waste chemistries. A statistically designed series of tests provided a pitting factor that relates the ratio of the inhibitor species to the aggressive species and the probability of observing pitting. An acceptable pitting factor was determined and was utilized for the development of a new chemistry envelope. The new chemistry envelope was compared to the envelope that was established for SCC and was determined to be bounding. Validation of the new chemistry envelope was performed via model simulations and comparison with historical experimental results and approaches to establishing chemistry envelopes. The new chemistry envelope will eventually be part of an overall assessment of the condition of the tanks and any changes made to the overall structural integrity program for the Hanford DSTs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Directly monitoring the shift in corrosion mechanisms of a model FeCrNi alloy driven by electric potential

Abstract Stainless steels are used in a myriad of engineering applications, including construction, automobiles, and nuclear reactors. Developing accurate, predictive mechanistic models for corrosion and electrochemical corrosion kinetics of stainless steels has been a topic of research studies over many decades. Herein, we quantified the aqueous corrosion kinetics of a model austenitic Fe–18Cr–14Ni (wt%) alloy in the presence and absence of applied potential using systematic in situ electrochemical atomic force microscopy (EC-AFM) and transmission electron microscopy (TEM). Without an applied bias, vertical dissolution of corrosion pits is controlled by the surface kinetics/diffusion hybrid mechanism, whereas lateral dissolution is diffusion controlled. When an electric bias is applied, the increase in corrosion rate is dominated by the nucleation of new pits. These insights gained by the in situ EC-AFM will allow applications of this method for a quantitative understanding of corrosion of a wider class of materials.

36 MATERIALS SCIENCE↗

Effect of debonded interfaces on corrosion of mild steel composites in supercritical CO2-saturated brines

The geologic sequestration of CO{sub 2} is a proposed method to limit greenhouse gas emissions and has been the subject of many studies in the last decade. Wellbore systems achieve isolation of the storage reservoir through a combination of steel (generally carbon steel) and Portland cement. CO{sub 2} leakage along the steel-cement interface has the potential to accelerate corrosion. We conduct experiments to assess the corrosion risk at cement-steel interface under in situ wellbore conditions. Wellbore interfaces were simulated by assemblies constructed of J55 mild steel and Portland class G (Epoxy was used in this study to separate) cement and corrosion was investigated in supercritical CO{sub 2} saturated brines, (NaCl = 1 wt%) at T = 50 C, pCO{sub 2} = 1200 psi with interface gap size = 100 {micro}m and {infinity} (open surface). The experiments were carried out in a high-pressure, 1.8 L autoclave. The corrosion kinetics were measured employing electrochemical techniques including linear polarization resistance and electrochemical impedance spectroscopy techniques. The corrosion scales were analyzed using secondary electron microscopy, back scattering electron microscopy, energy dispersive spectroscopy and x-ray diffraction. Corrosion rates decreased as time with or without interface gap. In this case corrosion rates are controlled by scale protectivity through the interface gap. Scaled steel corrosion rates were two orders of magnitude less compared with fresh steel. The corrosion scale is pseudo crystalline at the open interface. Well-crystallized scale was observed at interface gap sizes 100 {micro}m. All corrosion scales were composed of iron carbonates.

36 MATERIALS SCIENCE↗

Assessment of multi-stage telescopic control rods in a pebble bed reactor. Part II: corrosion and wear performance

To support High-Temperature Gas-Cooled Reactor designs, the effects of corrosion and wear on a SS316L telescopic control rod prototype were investigated in helium at 775 °C with up to 5 ppm oxygen for durations up to 500 h. Three deployment conditions were tested to assess their impact on wear and oxide formation: severe cycles, daily cycles, and gravity-driven deployments. Here, a chromium-rich oxide layer developed on regions exposed to the helium flow, reaching up to 2 µm in the most affected areas. No carburization or decarburization was observed. Oxide breakthrough occurred mainly at grooves and contact points during severe cycling of the telescopic rod, while in the other tests it was limited to contact points. Friction forces increased due to oxide growth and thermal expansion, the latter being the dominant factor, but never enough to hinder rod deployment significantly. Coaxial misalignment of stages was identified as the main potential risk to reliable operation under normal conditions.

Control rod↗

Study program for encapsulation materials interface for low cost silicon solar array

An atmospheric corrosion model was developed and verified by five months of corrosion rate and climatology data acquired at the Mead, Nebraska LSA test site. Atmospheric corrosion rate monitors (ACM) show that moisture condensation probability and ionic conduction at the corroding surface or interface are controlling factors in corrosion rate. Protection of the corroding surface by encapsulant was shown by the ACM recordings to be maintained, independent of climatology, over the five months outdoor exposure period. The macroscopic corrosion processes which occur at Mead are shown to be reproduced in the climatology simulator. Controlled experiments with identical moisture and temperature aging cycles show that UV radiation causes corrosion while UV shielding inhibits LSA corrosion.

Kaelble, D. H.↗

US PRACTICE FOR INTERIM WET STORAGE OF RRSNF

Aluminum research reactor spent nuclear fuel is currently being stored or is anticipated to be returned to the United States and stored at Department of Energy storage facilities at the Savannah River Site and the Idaho Nuclear Technology and Engineering Center. This paper summarizes the current practices to provide for continued safe interim wet storage in the U.S. Aluminum fuel stored in poor quality water is subject to aggressive corrosion attack and therefore water chemistry control systems are essential to maintain water quality. Fuel with minor breaches are safely stored directly in the basin. Fuel pieces and heavily damaged fuel is safely stored in isolation canisters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Corrosion Kinetics of Stainless Steel by Hydrogen Measurement under Deep Geological Repository Condition - 16047

Spent fuel assemblies consisting of stainless steels are expected to be disposed of in a deep underground repository. The radionuclides release and gas generation from activated metallic wastes in a disposal system will be controlled by the corrosion reaction. Most studies on stainless steel corrosion have been investigated under corrosion rates around several μm.a{sup -1}. A recent study has revealed that the corrosion rate of stainless steel is extremely slow-less than nm.a{sup -1} at 303 K. In the present study, corrosion kinetics at different temperatures up to 353 K were evaluated from the oxidation reaction by hydrogen gas measurement using 18Cr-8Ni austenitic stainless steel in a deoxygenated glass ampoule filled with a dilute NaOH solution of pH 12.5 for 24 months. Uniform corrosion and a reaction of 3Fe + 4H{sub 2}O → Fe{sub 3}O{sub 4} + 4H{sub 2} were assumed. After 24 months, the corrosion rates, which decreased with time but increased with rising temperature, were on average 7.80 x 10{sup -4}, 2.65 x 10{sup -3}, and 7.62 x 10{sup -3} μm.a{sup -1} at 303 K, 323 K, and 353 K, respectively. The corrosion kinetics were found to follow a parabolic rate law, which suggests the corrosion process is under diffusion control. The activation energy evaluated by the Arrhenius relationship of the parabolic rate constants has been determined to be 82.5 ± 6.2 kJ/mol, which corresponds to the values at high temperatures down to 423 K. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stress corrosion and hydrogen embrittlement

Service experience applications, experimental data generation, and the development of satisfactory quantitative theories relevant to the suppression and control of stress corrosion cracking in titanium are discussed. The impact of stress corrosion cracking (SCC) on the use of titanium alloys is considered, with emphasis on utilization in the aerospace field. Recent data on hot salt SCC, crack growth in hydrogen gas, and crack growth in liquid environments containing halide ions are reviewed. The status of the understanding of crack growth processes in these environments is also examined.

Blackburn, M. J.↗

Avoidance of stress corrosion susceptibility in high strength aluminum alloys by control of grain boundary and matrix microstructure

The relation of microstructure to the mechanical strength and stress corrosion resistance of highest strength and overaged tempers of BAR and 7050 aluminum alloys was investigated. Comparison is made with previously studied 7075 aluminum alloy. Optical microscopy, transmission electron microscopy, and differential scanning calorimetry were used to characterize the grain morphology, matrix microstructure, and grain boundary microstructure of these tempers. Grain boundary interparticle spacing was significant to stress corrosion crack propagation for all three alloys; increasing interparticle spacing led to increased resistance to crack propagation. In addition, the fire grain size in Bar and 7050 appears to enhance crack propagation. The highest strength temper of 7050 has a comparatively high resistance to crack initiation. Overall stress corrosion behavior is dependent on environment pH, and evaluation over a range of pH is recommended.

Adler, P.↗

Oxide scale formation on 316L and FeCrAl steels exposed to oxygen controlled static LBE at temperatures up to 800 °C

The corrosion behavior of three stainless steels (316L, Alkrothal 720 and Kanthal-APM) in static LBE with oxygen concentration of 10 –5 wt% at temperatures of 700 °C for 230 h and 800 °C for 360 h was studied. The steel surface morphology of the oxide scales formed was investigated by SEM, XRD and Raman spectroscopy and the cross-section by SEM and EDX. Here, a transitional inner-layer of Fe–Cr–Al oxides was found at the substrate interface and an Al-oxide outer layer on the Fe–Cr–Al alloys. Fast growing nonprotective oxide scale with underlying dissolution was observed on the 316L alloy

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hanford Tank Waste Disposition Integrated Flowsheet: Corrosion Specification Development Final Report

The Savannah River National Laboratory has developed a corrosion model to facilitate implementation of Hanford’s Direct Feed Low Activity Waste flowsheet. The focus was specifically on secondary effluent waste stream compositions from the Hanford Waste Treatment and Immobilization Plant’s melter off-gas treatment system returned to the Hanford Tank Farms (return stream.) The return stream compositions were predicted to contain components at relative concentrations that are significantly more corrosive toward the carbon steel waste tanks, specifically halide and sulfate anions, than the current waste compositions in the tank farms. Electrochemical tests were performed, utilizing a statistically designed matrix, to determine the corrosion chemistry limits that will mitigate pitting in the return stream. The current corrosion chemistry specifications for the Hanford Tank Farms do not mitigate for the halide concentrations that will be expected in the return stream. The model requires a 10:1 nitrite to total halide ratio, for stream compositions at a minimum of pH 10 and a maximum temperature of 40°C. The final specification may use other corrosion data that is being generated for the DST chemistry control limits to delineate between the effect of fluoride and chloride. This test program has employed statistically designed test matrices and electrochemical test methods to validate the corrosion model specifically at boundary regions to optimize corrosion control specifications.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗