Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORROSION PREVENTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A Magnetically Coupled Cryogenic Pump

Historically, cryogenic pumps used for propellant loading at Kennedy Space Center (KSC) and other NASA Centers have a bellows mechanical seal and oil bath ball bearings, both of which can be problematic and require high maintenance. Because of the extremely low temperatures, the mechanical seals are made of special materials and design, have wearing surfaces, are subject to improper installation, and commonly are a potential leak path. The ball bearings are non-precision bearings [ABEC-1 (Annular Bearing Engineering Council)] and are lubricated using LOX compatible oil. This oil is compatible with the propellant to prevent explosions, but does not have good lubricating properties. Due to the poor lubricity, it has been a goal of the KSC cryogenics community for the last 15 years to develop a magnetically coupled pump, which would eliminate these two potential issues. A number of projects have been attempted, but none of the pumps was a success. An off-the-shelf magnetically coupled pump (typically used with corrosive fluids) was procured that has been used for hypergolic service at KSC. The KSC Cryogenics Test Lab (CTL) operated the pump in cryogenic LN2 as received to determine a baseline for modifications required. The pump bushing, bearings, and thrust rings failed, and the pump would not flow liquid (this is a typical failure mode that was experienced in the previous attempts). Using the knowledge gained over the years designing and building cryogenic pumps, the CTL determined alternative materials that would be suitable for use under the pump design conditions. The CTL procured alternative materials for the bearings (bronze, aluminum bronze, and glass filled PTFE) and machined new bearing bushings, sleeves, and thrust rings. The designed clearances among the bushings, sleeves, thrust rings, case, and case cover were altered once again using experience gained from previous cryogenic pump rebuilds and designs. The alternative material parts were assembled into the pump, and the pump was successfully operated meeting all expected operating parameters. Unique pump sub-assembly parts were designed and manufactured by the CTL using specialized materials determined to be superior for cryogenic thermal applications under the pump design conditions. This work is a proof-of-concept/proof-of-operation of the pump only. Other known internal design modifications to the pump should be accomplished for the long-term use of the pump. An upscaled version of this pump, which is under development and testing at the CTL, can be used either for current or future vehicle loading or for vehicle replenishment. Scaling of this pump can be easily accomplished.

Hatfield, Walter↗

A survey of gas-side fouling in industrial heat-transfer equipment

Gas-side fouling and corrosion problems occur in all of the energy intensive industries including the chemical, petroleum, primary metals, pulp and paper, glass, cement, foodstuffs, and textile industries. Topics of major interest include: (1) heat exchanger design procedures for gas-side fouling service; (2) gas-side fouling factors which are presently available; (3) startup and shutdown procedures used to minimize the effects of gas-side fouling; (4) gas-side fouling prevention, mitigation, and accommodation techniques; (5) economic impact of gas-side fouling on capital costs, maintenance costs, loss of production, and energy losses; and (6) miscellaneous considerations related to gas-side fouling. The present state-of-the-art for industrial gas-side fouling is summarized by a list of recommendations for further work in this area.

Marner, W. J.↗

Degradation of Edge-Defined Film-Fed Silicon Glass–Glass Modules on Florida Rooftop After 22 Years

Thin silicon (< 100 μm) adoption can provide significantly lower cost. Kerfless technologies provide thin wafers while preventing material from being wasted. Understanding how this family of processing influences module reliability is important. A set of four edge-defined film-fed growth (EFG) silicon modules from a ten-module system in Florida is measured after 22 years of exposure. Power loss rates of 0.58–0.78% year -1 are measured for three modules, while a rate of 1.32% is measured for a module with severe delamination and corrosion. Short-circuit current degrades between 10.7% and 13.1% for all modules. Further, the losses are primarily optical and recombination based; however, series and shunt resistance effects play a non-negligible role. Pre-existing recombination losses exist but are exacerbated via degradation. Optical losses in short-circuit current are due in part to encapsulant yellowing. Electroluminescence (EL) images display the effects of processing on bulk quality by clearly showing lines of alternating brightness along the wafer length. To the authors’ knowledge, this is the first article displaying suns–V OC data, effective lifetime versus excess carrier density data, and module EL images for EFG silicon-based modules.

36 MATERIALS SCIENCE↗

Evaluating Microchannel Heat Exchanger Lifetime for Concentrating Solar Power Applications Research Performance Progress Report (RPPR-1)

Microchannel heat exchanger technology is being pursued for next generation CSP concepts for primary power cycle heat addition and power cycle heat recuperation due to the high heat transfer coefficients and pressure containment advantages of small sCO 2 channels. The economics of future CSP plants as dictated by the SETO 2020 or 2030 targets depend on a heat exchanger with a 30-year lifetime (resisting creep, fatigue, corrosion, erosion) and operational characteristics such as fast ramping and the ability to withstand thermal shock. However, the lifetime and operational limits of microchannel heat exchangers operating at high temperatures, particularly those constructed from high-nickel alloys, are not well known. This uncertainty has resulted in heat exchanger vendors not being able to accurately forecast heat exchanger lifetime as required by customers, specify operational limits as required by process engineers to prevent premature heat exchanger failure, or overdesign heat exchanger which leads to higher cost than necessary.

14 SOLAR ENERGY↗

Evaluating Microchannel Heat Exchanger Lifetime for Concentrating Solar Power Applications FY24Q4 (RPPR-1)

Microchannel heat exchanger technology is being pursued for next generation CSP concepts for primary power cycle heat addition and power cycle heat recuperation due to the high heat transfer coefficients and pressure containment advantages of small sCO 2 channels. The economics of future CSP plants as dictated by the SETO 2020 or 2030 targets depend on a heat exchanger with a 30-year lifetime (resisting creep, fatigue, corrosion, erosion) and operational characteristics such as fast ramping and the ability to withstand thermal shock. However, the lifetime and operational limits of microchannel heat exchangers operating at high-temperatures, particularly those constructed from high-nickel alloys, are not well known. This uncertainty has resulted in heat exchanger vendors not being able to accurately forecast heat exchanger lifetime as required by customers, specify operational limits as required by process engineers to prevent premature heat exchanger failure, or overdesign heat exchanger which leads to higher cost than necessary. Our goal is to evaluate heat exchanger lifetime and operational limits for the manufacturing and prototype design for next-generation CSP heat exchanger technology through a combination of collecting experimental data and modeling studies.

14 SOLAR ENERGY↗

Application and Certification of Comparative Vacuum Monitoring Sensors for Structural Health Monitoring of 737 Wing Box Fittings

Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today's extensive fleet of aging aircraft and space vehicles. The use of in-situ sensors for real-time health monitoring of aircraft structures are a viable option to overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. Prevention of unexpected flaw growth and structural failure can be improved if on-board health monitoring systems are used to continuously assess structural integrity. Such systems are able to detect incipient damage before catastrophic failures occurs. Condition-based maintenance practices could be substituted for the current time-based maintenance approach. Other advantages of on-board distributed sensor systems are that they can eliminate costly, and potentially damaging, disassembly, improve sensitivity by producing optimum placement of sensors and decrease maintenance costs by eliminating more time- consuming manual inspections. This report presents a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Boeing, Delta Air Lines, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp. and the Federal Aviation Administration (FAA) carried out a certification program to formally introduce Comparative Vacuum Monitoring (CVM) as a structural health monitoring solution to a specific aircraft wing box application. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM into an airline maintenance program and the document revisions necessary to allow for routine use of CVM as an alternate means of performing periodic structural inspects. To carry out the validation process, knowledge of aircraft maintenance practices was coupled with an unbiased, independent evaluation. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically-relevant experimental effort to quantify the reliability of the CVM system applied to the Boeing 737 Wing Box fitting application. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for CVM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and also is acceptable to both the aviation industry and regulatory bodies. This report presents the use of several different statistical methods, some of them adapted from NDI performance assessments and some proposed to address the unique nature of damage detection via SHM systems, and discusses how they can converge to produce a confident quantification of SHM performance An important element in developing SHM validation processes is a clear understanding of the regulatory measures needed to adopt SHM solutions along with the knowledge of the structural and maintenance characteristics that may impact the operational performance of an SHM system. This report describes the major elements of an SHM validation approach and differentiates the SHM elements from those found in NDI validation. The activities conducted in this program demonstrated the feasibility of routine SHM usage in general and CVM in particular for the application selected. They also helped establish an optimum OEM-airline-regulator process and determined how to safely adopt SHM solutions. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM technology. It will also streamline the regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

In situ sputter cleaning of thin film metal substrates for UHV-TEM corrosion studies.

A prerequisite for conducting valid corrosion experiments by in situ electron microscopy techniques is not only the achievement of UHV background pressure conditions at the site of the specimen but also the ability to clean the surface of the thin metal substrate specimen before initiation of the corrosive interaction. A miniaturized simple ion gun has been constructed for this purpose. The gun is small enough to be incorporated into an UHV electron microscope specimen chamber with hot stage in such a way as to permit bombardment of the substrate specimen while observing it by transmission electron microscopy TEM. It is shown that the ion beam generated is confined well enough to cause a sputtering removal of substrate material at a rate of approximately 5-10 A/min and to prevent the sputter deposition of contaminating material from the specimen holder.

Heinemann, K.↗

Structural Evaluation of Radially Expandable Cardiovascular Stents Encased in a Polyurethane Film

A method of encasing cardiovascular stents with an expandable polyurethane coating has been developed to provide a smooth homogeneous inner wall allowing for a confluent growth of endothelial cells. In this design, the metal wire stent structure is completely covered by the polyurethane film minimizing biocorrosion of the metal (stainless steel or nitinol), and providing a homogeneous surface for surface treatment and incorporation of various eluting drugs to prevent platelet aggregation while supporting endothelialization. The polyurethane surface was treated with a helium plasma for sterilization and promotes growth of cells. The paper details the performance of the coated film to expand with the metal stent up to 225 % during deployment. We present stress/strain behavior of polyurethane films, and subsequent plasma treatment of the surface and the adhesion of the coating to the stent structure upon expansion. A film of less than 25 tm was found to be sufficient for corrosion resistance and flexibility without producing any excess stress on the stent structure. Straining the film to 225 % and plasma modification did not affect the mechanical and surface properties while allowing for improved biocompatibility as determined by the critical surface tension, surface chemistry, and roughness.

Trigwell, Steve↗

Air Dehumidification using Ionic Liquid-Based Fiber Bundle Membrane Contactor

Air dehumidification is essential since excess moisture in the buildings causes discomfort to the occupants, encourages the production of air pathogens such as mold or mildew, and causes corrosion and rotting that degrade building materials. Existing moisture removal processes are mainly focused on condensation and desiccant (liquid or solid) techniques with direct contact between air and desiccant. However, these methods are energy-intensive, or desiccant might be lost or cause corrosion in the process. The main objective of this study is to investigate an ionic liquid-based liquid desiccant absorber based on a membrane fiber bundle. The novel system consists of membrane contactors containing bundles of 10,000 polypropylene fibers. The fiber bundles have 0.3 micron diameter, with ionic liquid flowing inside, and air flowing outside. The fibers provide a high contact area among phases: 1.4 m2 contact surface area in a 0.00015 m3 volume. The ionic liquid as a sorbent stipulates the selectivity for air, prevents the loss of solvent in the operation due to negligible volatility, provides fast diffusion due to low viscosity compared to common ionic liquids, and has high affinity and solubility in water. The dehumidification capacity of the membrane technology was experimentally investigated. The experimental results show that the ionic-liquid based membrane system can effectively remove excess moisture from the air. The novel fiber bundle dehumidification system has a system volume of 0.00798 m3 (7.98 L) and active heat and mass transfer surface area of 8.4 m2. It achieved an average dehumidification of 320 ± 25 W with a volumetric air flowrate of 3.1 m3/min (108 ft3/min).

Turnaoglu, Tugba↗

Role of Cr Content in Microstructure, Creep, and Oxidation Resistance of Alumina-Forming Austenitic Alloys at 850–900 °C

Creep-rupture properties and oxidation behavior of a series of alumina-forming austenitic (AFA) alloys with variations of Cr contents, based on Fe-(13.5-18)Cr-25Ni-4Al-1.5Nb-0.1C in weight percent, have been evaluated at 850–900 °C. The study investigates material responses in the properties and microstructure through compositional modifications in AFA alloys, targeting performance optimization of alloys under high-temperature, corrosive industrial environments. The creep-rupture life of the alloys at 850 °C and 30MPa monotonically decreased with increasing Cr content, which was correlated with changes in secondary phase volume fractions, such as the reduction in B2-NiAl + Laves-Fe2Nb and increase in Sigma-FeCr with Cr content. The oxidation test at 900 °C in a water-vapor containing environment revealed a range of Cr content from 13.9 to 15.7 wt.%, enabling the formation of stable, protective external alumina scale as well as preventing internal oxidation/nitridation for up to total 7000 h exposure. On the other hand, the alloys with >16.7 wt.% Cr formed Sigma precipitates, which caused a reduction in not only Cr but also Al in the austenite matrix, resulting in less oxidation resistance than other alloys. The findings will guide the further optimization of material performance in the AFA alloy series.

36 MATERIALS SCIENCE↗

FY24 Task 5: Leachate Disposition

Directly feeding sludge solids to the high-level waste (HLW) Waste Treatment Plant represents an alternative flowsheet seeking to initiate sludge processing as soon as possible. Key processing functions previously captured during baseline pretreatment operations include leaching and washing prior to solids concentration. These operations should be considered in the potential direct feed flowsheets to maximize waste feed loading, minimize HLW volume, and mitigate corrosion challenges associated with vitrification of high phosphate and fluoride concentrations. Additionally, single-shell tank (SST) retrievals and waste transfers to double-shell tanks (DSTs) in a direct feed flowsheet would likely also benefit from some level of leaching, washing, and solids concentration in order to reduce DST space and mission duration. These operations could occur in a new facility or potentially in available DSTs. If washing and leaching are utilized, an effective disposition pathway for the wash water and leachate solutions are needed. Three target species that benefit significantly from leaching and washing are phosphate, fluoride and aluminum. Phosphate (PO 4 3- ) and fluoride (F - ) can contribute substantially to the amount of carrier fluid needed for dissolution, and the resulting volume of liquid generated. Disposition of this retrieval solution should be evaluated in order to prevent crystallization of these anions throughout system processing. Since there is a high probability that any retrieval solutions will be at or near their PO 4 3- and F - solubility limits, evaporation or blending with a high Na supernate (>3.5 M) is not recommended for the wash water streams without a method to remove precipitants prior to solution disposal. Additionally, aluminum present in the southeast quadrant of the Hanford site represents roughly 60% of the waste solids in the initial processing tanks. These aluminum solids are in the form of gibbsite (Al(OH) 3 ) and can pose significant challenges for processing due to the fast-settling times and high solids loading associated with these materials. Easily remediated by caustic addition to the solids, these wash solutions could be processed through crystalline silicotitanate (CST) ion exchange columns to prepare the supernate solutions for disposition. The current target for feed conditions to the Low Activity Waste (LAW) melter are waste streams that contain nominally 5-6 M Na. Fractions within the tanks contain upwards of 0.2 M phosphate and fluoride in solution at 3.5 M Na. Concentrating these solutions above 5 M Na would result in an exceedance of the solubility limits, and potential for uncontrolled precipitation of the phosphate and fluoride crystal material. The resulting crystalline salt material is typically sodium fluoride phosphate, also referred to as natrophosphate (Na 7 FPO 4 ·19H 2 O). Salt phases are of importance in tank waste due to their chemical reactivity, which can result in precipitation, dissolution, or transformation, impacting any downstream processes (Bolling et al. 2020, Russell, Snow, and Peterson 2010). Salt generation and precipitation could pose challenges by causing system plugging and melter corrosion if left in the supernate stream, or limit sodium molarity of the supernate that would be accepted without incident in waste operations. To understand the impact of this salt generation, the crystallization of natrophosphate in multiple simulant feed matrices was studied to understand the implications of various tank waste supernate chemistries. Three matrices were examined: high PO 4 3- /low F - , low PO 4 3- /high F - , and an average matrix. Subsequent testing was performed with the average matrix with the inclusion of CsNO 3 , and a final run with the average matrix including CsNO 3 and a 137 Cs spike for tracer purposes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Space Shuttle Orbital Maneuvering Subsystem (OMS) Engine Propellant Leakage Ball-Valve Shaft Seals

Evidence of propellant leakage across ball-valve shaft seals has been noted during the disassembly of five flight engines and one test engine at the NASA Lyndon B. Johnson Space Center, White Sands Test Facility. Based on data collected during the disassembly of these five engines, the consequences of propellant leakage across the ball-valve shaft seals can be divided into four primary areas of concern: Damage to the ball-valve pinion shafts, damage to sleeved bearings inside the ball-valve and actuator assemblies, degradation of the synthetic rubber o-rings used in the actuator assemblies, and corrosion and degradation to the interior of the actuator assemblies. The exact time at which leakage across the ball-valve shaft seals occurs has not been determined, however, the leakage most likely occurs during engine firings when, depending on the specification used, ball-valve cavity pressures range as high as 453 to 550 psia. This potential pressure range for the ball-valve cavities greatly exceeds the acceptance leakage test pressure of 332 psia. Since redesign and replacement of the ball-valve shaft seals is unlikely, the near term solution to prevent damage that occurs from shaft-seal leakage is to implement a routine overhaul and maintenance program for engines in the fleet. Recommended repair, verification, and possible preventative maintenance measures are discussed in the paper.

Lueders, Kathy↗

Final Report on NASA Portable Laser Coating Removal Systems Field Demonstrations and Testing

Processes currently used throughout the National Aeronautics and Space Administration (NASA) to remove corrosion and coatings from structures, ground service equipment, small parts and flight components result in waste streams consisting of toxic chemicals, spent media blast materials, and waste water. When chemicals are used in these processes they are typically high in volatile organic compounds (VOC) and are considered hazardous air pollutants (HAP). When blast media is used, the volume of hazardous waste generated is increased significantly. Many of the coatings historically used within NASA contain toxic metals such as hexavalent chromium, and lead. These materials are highly regulated and restrictions on worker exposure continue to increase. Most recently the Occupational Safety and Health Administration (OSHA) reduced the permissible exposure limit (PEL) for hexavalent chromium (CrVI) from 52 to 5 micrograms per cubic meter of air as an 8-hour time-weighted average. Hexavalent chromium is found in numerous pretreatment and primer coatings used within the Space Shuttle Program. In response to the need to continue to protect assets within the agency and the growing concern over these new regulations, NASA is researching different ways to continue the required maintenance of both facility and flight equipment in a safe, efficient, and environmentally preferable manner. The use of laser energy to prepare surfaces for a variety of processes, such as corrosion and coating removal, weld preparation, and non destructive evaluation (NDE) is a relatively new application of the technology that has been proven to be environmentally preferable and in many cases less labor intensive than currently used removal methods. The novel process eliminates VOCs and blast media and captures the removed coatings with an integrated vacuum system. This means that the only waste generated are the coatings that are removed, resulting in an overall cleaner process. The development of a Portable Laser Coating Removal System (PLCRS) started as the goal of a Joint Group on Pollution Prevention (JG-PP) project, led by the Air Force, where several types of lasers in several configurations were thoroughly evaluated. Following this project, NASA decided to evaluate the best performers on processes and coatings specific to the agency. Laser systems used during this project were all of a similar design, between 40 and 500 Watts, most of which had integrated vacuum systems in order to collect materials removed from substrate surfaces during operation.

Rothgeb, Matthew J↗

Joint Test Protocol for Validation of Alternative Low-Emission Surface Preparation/Depainting Technologies for Structural Steel

Headquarters National Aeronautics and Space Administration (NASA) chartered the Acquisition Pollution Prevention (AP2) Office to coordinate agency activities affecting pollution prevention issues identified during system and component acquisition and sustainment processes. The primary objectives of the AP2 Office are to: (1) Reduce or eliminate the use of hazardous materials (HazMats) or hazardous processes at manufacturing, remanufacturing, and sustainment locations. (2) A void duplication of effort in actions required to reduce or eliminate HazMats through joint center cooperation and technology sharing. This project will identify, evaluate and approve alternative surface preparation technologies for use at NASA and Air Force Space Command (AFSPC) installations. Materials and processes will be evaluated with the goal of selecting those processes that will improve corrosion protection at critical systems, facilitate easier maintenance activity, extend maintenance cycles, eliminate flight hardware contamination and reduce the amount of hazardous waste generated. This Joint Test Protocol (JTP) contains the critical requirements and tests necessary to qualify alternative Low-Emission Surface Preparation/Depainting Technologies for Structural Steel Applications. These tests were derived from engineering, performance, and operational impact (supportability) requirements defined by a consensus of NASA and Air Force Space Command (AFSPC) participants. The Field Test Plan (FTP), entitled Joint Test Protocol for Validation of Alternative Low Emission Surface Preparation/Depainting Technologies for Structural Steel, prepared by ITB, defines the field evaluation and testing requirements for validating alternative surface preparation/depainting technologies and supplements the JTP.

Lewis, Pattie↗

Safety Benefits Assessment for Accident Tolerant Fuels in Consideration of Steam Generator Tube Degradation Using Dynamic Event Tree Analysis

Accident tolerant fuel (ATF) is expected to delay or prevent core damage by providing additional coping time under accidents involving loss of core cooling. The effect of extended coping time may vary depending on the plant response to accidents. Age-related component degradation that deteriorates plant performance over time could have an impact on the actual advantages of ATF. The potential safety benefits of two near-term ATF candidates, including Cr-coated Zr cladding and FeCrAl cladding, are assessed for a 2-in. loss-of-coolant accident with failed high-pressure safety injection using the dynamic event tree (DET) approach considering possible stress corrosion cracking of steam generator (SG) tubing under aging. The DET approach allows likelihood quantification of accident sequences leading to core damage, including stochastic variation of system response and human actions during accident mitigation. The safety benefits of the selected ATF claddings in terms of additional coping time and the core damage frequency reduction rate under specified accident situations were quantitatively estimated. The results show that the deployment of the two selected ATF claddings is expected to lead to longer coping times and lower core damage frequency due to the wider safety margin to peak cladding temperature they provide. The safety advantages would be greater as SG tube degradation proceeds. Thus, the two ATF candidates would lead to less severe consequences in terms of likelihood of core damage and susceptibility to the SG tube degradation than UO 2 -Zr fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-Situ Pipeline Coatings for Methane Emissions Mitigation and Quantification from Natural Gas Pipelines

Addressing the current health of the nation’s existing 3 million miles of pipeline infrastructure is key to preventing further climate change. In 2020, natural gas production exceeded 34 trillion cubic feet (Tcf). Roughly 75% of natural gas consists of methane (CH 4 ), which is up to 25 times more powerful than carbon dioxide (CO 2 ) at trapping heat within the atmosphere over a 100-year period, and studies from the Environmental Defense Fund (EDF) estimate approximately 2% of all the natural gas produced will be lost during normal operations due to unaddressed leaks. This does not even consider the risks of major disaster due to pipeline failure, or the losses and extra fuel costs incurred due to corrosion and scale deposits in under-maintained pipelines. The objective of the proposed research is to demonstrate the protection capabilities and economic benefits of Oceanit’s internal pipe surface treatment, known as DragX™. DragX™ is a chemically resistant, water-and-oil repellent nanocomposite system that can be readily applied in-situ on natural gas transmission and distribution pipelines with a minimum of surface preparation. This makes it an ideal candidate for in-place retrofitting and refurbishment of existing pipelines without the need for expensive extraction and replacement. DragX™ is also able to significantly reduce the surface roughness, and subsequently, the frictional drag forces within a pipeline, improving throughput, decreasing energy costs of pressurization and pumping, and allowing for longer pipeline operation without interruption, reducing the methane emitted during pipe isolation and venting. As part of this project, Oceanit has utilized the Department of Energy’s support to fully develop, de-risk and prove the DragX™ core technology is both economically viable and commercially desirable to pipeline operators and energy companies alike. DragX™ material properties were optimized in this effort both for ease of applicability, to provide value in certain key parameters, and was demonstrated on pilot applications exceeding 2 miles in length. Beyond the already field demonstrated applications, this innovative nanocomposite surface treatment has the potential to be the backbone for CO 2 and Hydrogen transporting pipeline infrastructure. The learnings from this project could accelerate the deployment of surface treatment technologies related to the energy transition infrastructure, thus benefitting the clean energy initiatives in the United States and all around the world.

03 NATURAL GAS↗

Calcification prevention tablets

Citric acid tablets, which slowly release citric acid when flushed with water, are under development by the Navy for calcification prevention. The citric acid dissolves calcium carbonate deposits and chelates the calcium. For use in urinals, a dispenser is not required because the tablets are non-toxic and safe to handle. The tablets are placed in the bottom of the urinal, and are consumed in several hundred flushes (the release rate can be tailored by adjusting the formulation). All of the ingredients are environmentally biodegradable. Mass production of the tablets on commercial tableting machines was demonstrated. The tablets are inexpensive (about 75 cents apiece). Incidences of clogged pipes and urinals were greatly decreased in long term shipboard tests. The corrosion rate of sewage collection pipe (90/10 Cu/Ni) in citric acid solution in the laboratory is several mils per year at conditions typically found in traps under the urinals. The only shipboard corrosion seen to date is of the yellow brass urinal tail pieces. While this is acceptable, the search for a nontoxic corrosion inhibitor is underway. The shelf life of the tablets is at least one year if stored at 50 percent relative humidity, and longer if stored in sealed plastic buckets.

Lindsay, Geoffrey A.↗

Amphiphilic Block Copolymers for Flocculation and Hydrophobization of Legacy Waste Suspensions in Flotation Driven Dewatering Operations - 20162

Flotation has been effectively demonstrated as a low footprint, high efficiency separation process when utilising simple anionic surface modifying agents such as sodium dodecyl sulphate (SDS). These agents increase hydrophobicity to remove suspended cationic surface charged particulates such as Mg(OH){sub 2} from waste suspensions similar to those at British nuclear fuel management sites- where corrosion processes have degraded fuel cladding. The technology is advantageous as it could effectively be retrofitted into existing waste management facilities at nuclear waste management sites such Sellafield and Hanford as the simplicity (no moving parts) and size of this technology coupled with low cost of construction could be rapidly deployed to aid in risk and hazard reduction decommissioning operations with minimum impact to secondary waste generation. Previously, sodium dodecyl sulphate has been deployed as a collector agent to increase the hydrophobicity of Mg(OH){sub 2} suspended particles, achieving a maximum particulate extraction percentage of 93%. To achieve further particulate extraction, flotation performance has been determined to be a function of the hydrodynamic limitations extracting fine material (>20 μm). Fine particulates have been shown in the minerals industry to have an inability to overcome slipstreams created from rising bubbles in flotation cells, likely due to the low mass and thus momentum of the colloidal material, preventing interaction between the hydrophobized particles and air-water interfaces (bubbles). To combat this mass transfer resistance poly(acrylic acid)-block-poly(n-butyl acrylate) amphiphilic diblock copolymers were synthesised via reversible addition-fragmentation chain-transfer (RAFT) polymerisation. The anticipated mode of action of these polymers involves the hydrophilic poly(acrylic acid) block polymer acting as a flocculation agent to increase the mass of the aggregates, and the hydrophobic poly(n-butyl acrylate) modifies the hydrophobicity of the resulting flocs. The concentration of this polymer (termed a macro-collector) was varied and the change in particle size distribution of the particulate suspension was analysed using static light scattering. The flotation performance was then characterised by several methods including percentage particulate recovery, volume reduction factor and residual bulk particulate concentration. This was then benchmarked against the traditional surfactant collector agent SDS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗