Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORROSION TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The stress corrosion resistance and the cryogenic temperature mechanical properties of hot rolled Nitronic 32 bar material

The ambient and cryogenic temperature mechanical properties and the ambient temperature stress corrosion properties of hot rolled and centerless ground Nitronic 32 stainless steel bar material are presented. The mechanical properties of longitudinal specimens were evaluated at test temperatures from ambient to liquid hydrogen. The tensile test data indicated increasing smooth tensile strength with decreasing temperature to liquid hydrogen temperature. However, below -200 F (-129.0 C) the notched tensile strength decreased slightly and below -320 F (-196.0 C) the decrease was significant. The elongation and reduction of area decreased drastically at temperatures below -200 F (-129.0 C). The Charpy V-notched impact energy decreased steadily with decreasing test temperature. Stress corrosion tests were performed on longitudinal tensile specimens stressed to 0, 75, and 90 percent of the 0.2 percent yield strength and on transverse 'C'-ring specimens stressed to 75 and 90 percent of the yield strength and exposed to: alternate immersion in a 3.5 percent NaCl bath, humidity cabinet environment, and a 5 percent salt spray atmosphere. The longitudinal tensile specimens experienced no corrosive attack; however, the 'C'-rings exposed to the alternate immersion and to the salt spray experienced some shallow etching and pitting, respectively. Small cracks appeared in two of the 'C'-rings after one month exposure to the salt spray.

Montano, J. W. L.↗

Corrosion Control in Carbon Fiber Reinforced Plastic (CFRP) Composite-Aluminum Closure Panel Hem Joints

This project targeted the implementation of CFRP/Al closure panels as a drop-in replacement for all-aluminum closures used in automobile production today. The project focused on the development of corrosion fundamentals involving CFRP materials and the use of those materials in mixed-material joints. Numerous studies were completed to benchmark current materials and test mixed metal joints. Good correlation was found between outdoor exposures and laboratory cyclic corrosion testing. The insights from the corrosion testing fundamentals and benchmarking phases informed the development of low-cure adhesive and electrocoats and conductive primers for the CFRP. Adhesive and electrocoat materials were successfully developed meeting low-cure targets for bake (150C/10min). These materials were scaled-up and used to produce 5 prototype liftgates to further evaluate CFRP/Al joints in a full-scale part. The lower cure materials enabled mitigation of CTE mismatch and reduced the required bake temperature, resulting in reduced part distortion. Corrosion testing of the liftgates revealed unexpected increases in corrosion relative to the standard bake materials. While rigorous evaluation of the parts was not possible due to numerous complexities associated with prototype testing, the results provided significant insights into the material behavior of CFRP/Al joints. Key learnings from the project included a better understanding of the system complexity (interplay of substrate/primer conductivity, production of full-scale prototypes), advances in coating/adhesive design for low-cure applications involving CFRP, and advancement of corrosion test protocols for CFRP.

36 MATERIALS SCIENCE↗

Alloys For Flexible Hoses In A Corrosive Environment

High-nickel alloy resists pitting corrosion. Report evaluates metal alloys for flexible hoses in corrosive environment. Tested to find alternatives to 304L stainless steel. Nineteen alloys selected for testing on basis of reputation for resistance to corrosion. Top five, in order of decreasing resistance to corrosion: Hastelloy(R) C-22, Inconel(R) 625, Hastelloy(R) C-276, Hastelloy(R) C-4, and Inco(R) alloy G-3. Of these, Hastelloy(R) C-22 found best for flexible-hose application.

Macdowell, Louis G., III↗

Microencapsulation Technology for Corrosion Mitigation by Smart Coatings

A multifunctional, smart coating for the autonomous control of corrosion is being developed based on micro-encapsulation technology. Corrosion indicators as well as corrosion inhibitors have been incorporated into microcapsules, blended into several paint systems, and tested for corrosion detection and protection effectiveness. This paper summarizes the development, optimization, and testing of microcapsules specifically designed to be incorporated into a smart coating that will deliver corrosion inhibitors to mitigate corrosion autonomously. Key words: smart coating, corrosion inhibition, microencapsulation, microcapsule, pH sensitive microcapsule, corrosion inhibitor, corrosion protection pain

Buhrow, Jerry↗

Effect of chromium on corrosion resistance of Ni-Cr-Mo-Gd alloys in seawater

Neutron absorbing materials are being considered within commercial spent nuclear fuel disposal canisters to maintain nuclear subcriticality in storage. To select candidate alloys for the canisters, both neutron absorption and corrosion resistance should be considered. This work examines corrosion resistance of Ni-Cr-Mo-Gd alloys developed specifically for neutron absorption. The addition of Gd results in a secondary gadolinide phase (Ni 5 Gd) that significantly changes the corrosion properties. Testing was performed primarily in seawater at 30°C. Seawater was selected as the most prevalent terrestrial brine and is characterized by a high chloride concentration. Various electrochemical corrosion techniques were carried out to evaluate Ni-Cr-Mo-Gd alloys with different Cr compositions and investigate the role of Ni 5 Gd phase on corrosion behavior. C22 was included as a benchmark material, due to the similarity in composition and the significant corrosion data available. Here, test results showed a tendency to passivate over time which is attributed to dissolution of surface exposed Ni 5 Gd phase. Cross-sectional analysis indicated that dissolution could penetrate hundreds of micrometers deep under aggressive conditions. It was found that higher Cr variant (21.01%) showed much shallower impact, suggesting Cr prevented primary phase corrosion and thus reduced Ni 5 Gd phase dissolution. Acid pickling of the specimens showed much less dissolution for a higher Cr material and suggested some primary phase dissolution for the low Cr specimen. Acid pickled specimens showed positive shifts in the repassivation potential, suggesting increased surface passivation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ECLSS Universal Waste Management System (UWMS) Metal Materials Compatibility Study- Electrochemical and Crevice Corrosion Evaluation

Electrochemical and crevice corrosion laboratory test results are presented for three noble metal candidates with possible application on the Universal Waste Management System (UWMS) in support of the Environmental Control and Life Support System (ECLSS) aboard the International Space Station (ISS). The three metal candidates, which included Inconel 625, Hastelloy C276 and Titanium 6Al-4V, were evaluated in two solutions representative of the acidic pretreatment formulations utilized during processing of waste liquids within the ECLSS. Final test results and data analysis indicated that the passive layer on all three metals provides excellent corrosion protection in both solutions under standard test conditions.

Lee, R. E.↗

Stress corrosion evaluation of powder metallurgy aluminum alloy 7091 with the breaking load test method

The stress corrosion behavior of the P/M aluminum alloy 7091 is evaluated in two overaged heat treatment conditions, T7E69 and T7E70, using an accelerated test technique known as the breaking load test method. The breaking load data obtained in this study indicate that P/M 7091 alloy is highly resistant to stress corrosion in both longitudinal and transverse orientations at stress levels up to 90 percent of the material yield strength. The reduction in mean breaking stress as a result of corrosive attack is smallest for the more overaged T7E70 condition. Details of the test procedure are included.

Domack, Marcia S.↗

Development of a Enhanced Thermal Barrier for RSRM Nozzle Joints

A carbon fiber rope is being considered as replacement for the RTV thermal barrier that is currently used to protect o-rings in RSRM nozzle joints, Performance requirements include its ability to cool propellant gases filter slag and particulates, and conform to various joint assembly conditions as well as dynamic flight motion. Testing has shown its superior heat resistance, even in oxidative and corrosive environments. Testing has also demonstrated excellent performance of this system in sub-scale motors. Cold flow testing, has demonstrated its ability to conform to motor dynamics. Manufacture and assembly testing have demonstrated the ease of gland machining as well as assembly in a full-scale nozzle.

Bauer, P. H.↗

A 20 Year Lifecycle Study for Launch Facilities at the Kennedy Space Center

The lifecycle cost analysis was based on corrosion costs for the Kennedy Space Center's Launch Complexes and Mobile Launch Platforms. The first step in the study involved identifying the relevant assets that would be included. Secondly, the identification and collection of the corrosion control cost data for the selected assets was completed. Corrosion control costs were separated into four categories. The sources of cost included the NASA labor for civil servant personnel directly involved in overseeing and managing corrosion control of the assets, United Space Alliance (USA) contractual requirements for performing planned corrosion control tasks, USA performance of unplanned corrosion control tasks, and Testing and Development. Corrosion control operations performed under USA contractual requirements were the most significant contributors to the total cost of corrosion. The operations include the inspection of the pad, routine maintenance of the pad, medium and large scale blasting and repainting activities, and the repair and replacement of structural metal elements. Cost data was collected from the years between 2001 and 2007. These costs were then extrapolated to future years to calculate the 20 year lifecycle costs.

Kolody, Mark R.↗

Ni-Ti Next Generation Bearings for Space Applications

NASA applications challenge traditional bearing materials. The rigors of launch often include heavy shock loads and exposure to corrosive environments (e.g., salt spray). Unfortunately, ball and roller bearings made from hardened steels are vulnerable to Brinell denting and rust which can limit performance and life. Ceramic materials can eliminate corrosion concerns but their high stiffness and extreme hardness actually makes denting problems worse. In this presentation, an emerging superelastic alloy, NiTi, is introduced for rolling element bearing applications. Through a decade of RD, NiTi alloy bearings have been put through a comprehensive series of life and performance tests. Hardness, corrosion, strength, stiffness, and rolling contact fatigue tests have been conducted and reported. Ball bearings ranging in size from 12 to 50mm bore have been successfully engineered and operated over a wide range of speeds and test conditions including being submerged in water. The combination of high hardness, moderate elastic modulus, low density, and intrinsic corrosion immunity provide new possibilities for mechanisms that operate under extreme conditions. Recent preliminary tests indicate that bearings can be made from NiTi alloys that are easily lubricated by conventional oils and greases and exhibit acceptable rolling contact fatigue resistance. This presentation introduces the NiTi materials systems and shows how NASA is using it to alleviate several specific problems encountered in advanced space applications.

bearings↗

A Multifunctional Smart Coating for Autonomous Corrosion Control

Corrosion is a destructive process that often causes failure in metallic components and structures. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to control it. The multi-functionality of the coating is based on micro-encapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of other existing microcapsules designs, the corrosion controlled release function that allows the delivery of corrosion indicators and inhibitors on demand only when and where needed. Corrosion indicators as well as corrosion inhibitors have been incorporated into microcapsules, blended into several paint systems, and tested for corrosion detection and protection efficacy. This

Calle, Luz Marina↗

Hanford Double Shell Waste Tank Corrosion Studies- Final Report FY2024

For fiscal year (FY) 2024, the Savannah River National Laboratory (SRNL) focused on two experimental tasks related to Hanford Double Shell Tank (DST) chemistry and integrity. The first task focused on understanding risk of corrosion due to formation of either continuous layers or discrete patches of solids on the tanks’ inner sidewalls and bottoms. The objective of this task was to determine the effect of solid deposits on the corrosion risk to the tank bottom, and whether a combination of scale, saltcake and loose solids lead to under deposit corrosion. Electrochemical testing in a single cell arrangement was employed to determine a threshold inhibitor level for the interstitial liquid in the solids, above which carbon steel was not susceptible to corrosion beneath the solids. The inhibitor levels tested were based on the previously determined probability of failure for carbon steel in a simulated waste (i.e., Pitting Factor).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser-Based Instrument Measures Propagation Of Cracks

Report describes use of commerical laser displacement meter to measure propagation of cracks in stainless-steel specimens in stress tests in corrosive (salt-spray) environment. Measurements directed toward determining time from beginning of each test until onset of propagation of crack.

Lee, Rupert U.↗

A Multifunctional Coating for Autonomous Corrosion Control

Corrosion is a destructive process that often causes failure in metallic components and structures. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to control it. The multi-functionality of the coating is based on microencapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of other existing microcapsules designs, the corrosion controlled release function that allows the delivery of corrosion indicators and inhibitors on demand only when and where they are needed. Corrosion indicators as well as corrosion inhibitors have been incorporated into the microcapsules, blended into several paint systems, and tested for corrosion detection and protection efficacy.

Calle, Luz M.↗

Burner rig corrosion of SiC at 1000 deg C

Sintered alpha-SiC was examined in both oxidation and hot corrosion with a burner rig at 400 kPa (4 atm) and 1000 C with a flow velocity of 310 ft/sec. Oxidation tests for times to 46 hr produced virtually no attack, whereas tests with 4 ppm Na produced extensive corrosion in 13-1/2 hr. Thick glassy layers composed primarily of sodium silicate formed in the salt corrosion tests. This corrosion attack caused severe pitting of the silicon carbide substrate which led to a 32 percent strength decrease below the as-received material. Parallel furnace tests of Na2SO4/air induced attacked yielded basically similar results with some slight product composition differences. The differences are explained in terms of the continuous sulfate deposition which occurs in a burner rig.

Jacobson, N. S.↗

Burner rig corrosion of SiC at 1000 C

Sintered alpha-SiC was examined in both oxidation and hot corrosion with a burner rig at 400 kPa (4 atm) and 1000 C with a flow velocity of 94 m/s. Oxidation tests for times to 46 h produced virtually no attack, whereas tests with 4 ppm Na produced extensive corrosion in 13.5 h. Thick glassy layers composed primarily of sodium silicate formed in the salt corrosion tests. This corrosion attack caused severe pitting on the silicon carbide substrate and led to a 32 percent decrease in strength, compared to the as-received material. Parallel furnace tests of Na2SO4/air-induced attack yielded basically similar results, with slight product composition differences. The differences are explained in terms of the continuous sulfate deposition which occurs in a burner rig.

Jacobson, N. S.↗