Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Lawrence Berkley National Laboratory Building 59 (Raw)

The building management system in Building 59 is monitoring and archiving building-level electricity usage, HVAC and lighting system states (e.g., setpoint, temperature, flow rate, pressure), indoor environmental conditions (air temperature, relative humidity, CO2), on-site weather (air temperature, relative humidity), and especially occupant counts as well as other metrics such as Wi-Fi signal. This dataset could support multiple use cases, such as model predictive control and occupant related demand management. Raw data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lawrence Berkeley National Lab Building 59

The building management system in Building 59 is monitoring and archiving building-level electricity usage, HVAC and lighting system states (e.g., setpoint, temperature, flow rate, pressure), indoor environmental conditions (air temperature, relative humidity, CO2), on-site weather (air temperature, relative humidity), and especially occupant counts as well as other metrics such as Wi-Fi signal. This dataset could support multiple use cases, such as model predictive control and occupant related demand management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting Biological Cleanliness: An Empirical Bayes Approach for Spacecraft Bioburden Accounting

To comply with the international planetary protection policy set forth by the Committee on Space Research and NASA Agency level requirements, spacecraft destined to biologically sensitive planetary bodies have to minimize terrestrial biological contamination. Analysis, testing and inspection are the standard forward verification activities that are used to demonstrate compliance with the biological contamination requirements. For testing of spacecraft surface areas, a swab or wipe sample is collected from surfaces prior to last access and subsequently processed in the lab using NASA Approved Planetary Protection Methods for Culture Based Assays. Raw data resulting from this assay is then statistically treated employing a mathematical paradigm stemming from the 1970’s Viking Lander Project to generate the bioburden density and total microbial bioburden present. This standard approach arbitrarily accounts for error and provides an upper conservative bound as it reports the maximum number of spores estimated to be present on flight hardware surfaces. A bioburden density estimate factors in the following variables: the observed bioburden count, representative volume processed, sampling efficiencies. Notably, to account for error in the approach, a 0 observed count is arbitrarily changed to a count of 1 for each hardware grouping. The data generated by spacecraft bioburden verification campaigns in the past have resulted in <80% of wipes and <90% of swabs containing a bioburden count of 0. As such, having a robust and well documented statistical approach for dealing with the probability of low incident rates is necessary to be able to estimate spacecraft bioburden. Being able to statistically describe the bioburden distribution and associated confidence level is a gamechanger for the development of bioburden allocations during mission design and will allow for tighter management of risk throughout spacecraft build. Thus, Empirical Bayes statistical approach was evaluated to estimate the microbial bioburden on spacecraft to mitigate the aforementioned mathematical concerns and provide a probabilistic bioburden distribution of the flight hardware surface. For application of this approach to performing bioburden calculations, a range of non-informative prior assumptions on hardware surfaces are explored for Bayesian analyses while informative priors using posterior distributions from prior assays are utilized for Empirical Bayes analyses. Several non-informative priors are currently under investigation to assess fitness including use of these priors to serve as a foundation to build off of NASA specification values or a basis of risk to account for unknowns during the integration and testing process. Informative priors under consideration are generated using sampled bioburden values from hardware originating within like processing environments (e.g. vendor cleaning process or similar assembly process), temporal spacecraft status events as a prediction for hardware cleanliness of future samples, and heritage system bioburden actuals to predict allocation for subsequent missions. Informative priors and probabilistic bioburden distributions are then validated using data sets from the Mars Exploration Rover, Mars Science Laboratory, and InSight missions. Using Empirical Bayes approach to generate a probabilistic bioburden distribution as demonstrated through mission use cases provides a valid approach for use in the end-to-end requirements verification process.

97 MATHEMATICS AND COMPUTING↗

Bayesian Framework for Bioburden Density Estimation in Planetary Protection

To comply with the international planetary protection policy set forth by the Committee on Space Research and NASA Agency level requirements, spacecraft destined to biologically sensitive planetary bodies have to minimize terrestrial biological contamination. Analysis, testing and inspection are the standard forward verification activities that are used to demonstrate compliance with the biological contamination requirements. For testing of spacecraft surface areas, a swab or wipe sample is collected from surfaces prior to last access and subsequently processed in the lab using NASA Approved Planetary Protection Methods for Culture Based Assays. Raw data resulting from this assay is then statistically treated employing a mathematical paradigm stemming from the 1970’s Viking Lander Project to generate the bioburden density and total microbial bioburden present. This standard approach arbitrarily accounts for error and provides an upper conservative bound as it reports the maximum number of spores estimated to be present on flight hardware surfaces. A bioburden density estimate factors in the following variables: the observed bioburden count, representative volume processed, sampling efficiencies. Notably, to account for error in the approach, a 0 observed count is arbitrarily changed to a count of 1 for each hardware grouping. The data generated by spacecraft bioburden verification campaigns in the past have resulted in <80% of wipes and <90% of swabs containing a bioburden count of 0. As such, having a robust and well documented statistical approach for dealing with the probability of low incident rates is necessary to be able to estimate spacecraft bioburden. Being able to statistically describe the bioburden distribution and associated confidence level is a gamechanger for the development of bioburden allocations during mission design and will allow for tighter management of risk throughout spacecraft build. Thus, Empirical Bayes statistical approach was evaluated to estimate the microbial bioburden on spacecraft to mitigate the aforementioned mathematical concerns and provide a probabilistic bioburden distribution of the flight hardware surface. For application of this approach to performing bioburden calculations, a range of non-informative prior assumptions on hardware surfaces are explored for Bayesian analyses while informative priors using posterior distributions from prior assays are utilized for Empirical Bayes analyses. Several non-informative priors are currently under investigation to assess fitness including use of these priors to serve as a foundation to build off of NASA specification values or a basis of risk to account for unknowns during the integration and testing process. Informative priors under consideration are generated using sampled bioburden values from hardware originating within like processing environments (e.g. vendor cleaning process or similar assembly process), temporal spacecraft status events as a prediction for hardware cleanliness of future samples, and heritage system bioburden actuals to predict allocation for subsequent missions. Informative priors and probabilistic bioburden distributions are then validated using data sets from the Mars Exploration Rover, Mars Science Laboratory, and InSight missions. Using Empirical Bayes approach to generate a probabilistic bioburden distribution as demonstrated through mission use cases provides a valid approach for use in the end-to-end requirements verification process.

97 - MATHEMATICS AND COMPUTING↗

Evaluation of neutron dosimetry capabilities with the MC-15 portable multiplicity counter

This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanism and kinetics of the oxidation of 1,3-butadien-1-yl (n-C 4 H 5 ): a theoretical study

Here, ab initio CCSD(T)-F12/cc-pVTZ-f12//B3LYP/6-311G(d,p) calculations of the C 4 H 5 O 2 potential energy surface have been combined with Rice–Ramsperger–Kassel–Marcus Master Equation (RRKM-ME) calculations of temperature- and pressure-dependent rate constants and product branching ratios to unravel the mechanism and kinetics of the n-C 4 H 5 + O 2 reaction. The results indicate that the reaction is fast, with the total rate constant being in the range of 3.4–5.6 × 10 –11 cm 3 molecule –1 s –1 . The main products include 1-oxo-n-butadienyl + O and acrolein + HCO, with their cumulative yield exceeding 90% at temperatures above 1500 K. Two conformers of 1-oxo-n-butadienyl + O are formed via a simple mechanism of O 2 addition to the radical site of n-C 4 H 5 followed by the cleavage of the O–O bond proceeding via a van der Waals C 4 H 5 O∙∙∙O complex. Alternatively, the pathways leading to acrolein + HCO involve significant reorganization of the heavy-atom skeleton either via formal migration of one O atom to the opposite end of the molecule or its insertion into the C1–C2 bond. Not counting thermal stabilization of the initial peroxy adducts, which prevails at low temperatures and high pressures, all other products share a minor yield of under 5%. Rate constants for the significant reaction channels have been fitted to modified Arrhenius expressions and are proposed for kinetic modeling of the oxidation of aromatic molecules and 1,3-butadiene. As a secondary reaction, n-C 4 H 5 + O 2 can be a source for the formation of acrolein observed experimentally in oxidation of the phenyl radical at low combustion temperatures, whereas another significant (secondary) product of the C 6 H 5 + O 2 reaction, furan, could be formed through unimolecular decomposition of 1-oxo-n-butadienyl. Both the n-C 4 H 5 + O 2 reaction and unimolecular decomposition of its 1-oxo-n-butadienyl primary product are shown not to be a substantial source of ketene.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutrons in MINERvA and the Antineutrino Multi-Neutron Production Cross Section

Neutrinos are among a handful of particles in the Standard Model of particle physics whose properties have not yet been fully measured. Neutrino oscillations, discovered in the late 1990s, still have yet to be fully characterized. Early evidence suggests that neutrinos and antineutrinos may undergo neutrino oscillations differently. So, multiple collaborations are building and operating kTon-scale particle detectors to try to measure this CP violation in the neutrino sector of the Standard Model. Measuring neutrino and antineutrino energies is essential to characterizing oscillation phenomena. But neutrons interfere with (anti)neutrino energy measurements because they are hard to detect in (anti)neutrino detectors. Furthermore, there are very few measurements of neutrons produced by (anti)neutrinos in the energy range of interest to accelerator-based oscillation experiments. The MINERvA collaboration initially tried to fill this gap by measuring the rate of neutron-induced activity i n plastic. The data deviated significantly from leading model predictions, but it could not be determined which models needed to be tuned. MINERvA’s first neutron counting result also cannot be compared to future models because it was not suitable for unsmearing. This thesis first expands upon MINERvA’s first foray into neutron detection at higher antineutrino energy. Neutron detection efficiency is enhanced by advances in analysis algorithms. Then, an unsmeared cross section for producing two or more neutrons is measured. Existing antineutrino interaction models again over-predict the rate of neutron production by antineutrinos. Preliminary neutron production rate measurements in MINERvA’s iron and lead targets suggest that models are also over-predicting neutron production in heavier nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radon-induced backgrounds in the NEXT-100 experiment

The NEXT-100 detector at the LSC aims at the first competitive search for the 0νββ decay using a high-pressure $^{136}$Xe electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal $^{222}$Rn activity is found to be (0.95±0.04(stat)±0.09(sys)) Bq/m$^{3}$, while no traces of $^{220}$Rn have been observed. Most of the $^{222}$Rn progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced $^{214}$Bi of (0.97±0.05(stat)±0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the 0νββ region of interest is evaluated as (7.3±1.5(stat)±0.8(sys))×10$^{−4}$ counts/(keV·kg·yr) after selection of the fully contained events. This background index is reduced to ∼4×10$^{−5}$ counts/(keV·kg·yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.[graphic not available: see fulltext]

Cortes-Parra, C. [Valencia U., IFIC] (ORCID:000000↗

Chitosan Coating Functionalized with Flaxseed Oil and Green Tea Extract as a Bio-Based Solution for Beef Preservation

Ecological and safe packaging solutions arise as pivotal points in the development of an integrated system for sustainable meat production. The aim of this study was to assess the effect of a combined chitosan (Ch) + green tea extract (GTE) + essential oil (thyme oil, TO; flaxseed oil, FO; or oregano oil, OO) coating on the safety and quality of vacuum-packaged beef during storage at 4 °C. An optimized bio-based coating formulation was selected (2% Ch + 2% GTE + 0.1% FO) to be applied to three fresh beef cuts (shoulder, Sh; knuckle, Kn; Striploin, St) based on its pH (5.8 ± 0.1), contact angle (22.3 ± 0.4°) and rheological parameters (viscosity = 0.05 Pa.s at shear rate > 20 s−1). Shelf-life analysis showed that the Ch–GTE–FO coating delayed lipid oxidation and reduced total viable counts (TVC) and Enterobacteriaceae growth compared with uncoated beef samples over five days. In addition, Ch–GTE–FO coating decreased total color changes of beef samples (e.g., ∆E* = 9.84 and 3.94, for non-coated and coated Kn samples, respectively) for up to five days. The original textural parameters (hardness, adhesiveness and springiness) of beef cuts were maintained during storage when Ch–GTE–FO coating was applied. Based on the physicochemical and microbial characterization results, the combination of the Ch–GTE–FO coating developed was effective in preserving the quality of fresh beef cuts during refrigerated storage along with vacuum packaging.

Mendes, Cíntia G.↗

Digital encoding algorithm for pixelated detectors

A detector for imaging and efficiently digitizing a spatial distribution of photon flux includes pixel circuits that compressively encode pixel values generated by integrated analog to digital converters (ADCs). On-pixel digital compression circuits (DCCs) implement compression to increase continuous frame rate by reducing the number of bits per pixel while keeping quantization error below Poisson noise. Several mapping algorithms for photon-counting and charge-integrating detectors and compact digital logic implementations are presented.

Hammer, Michael P.↗

eDNAjoint: An R package for interpreting paired or semi‐paired environmental DNA and traditional survey data in a Bayesian framework

Abstract Environmental DNA (eDNA) sampling is increasingly used in surveys of species distribution as a potentially sensitive and efficient monitoring method. Yet access to modelling tools designed specifically for interpreting this new data type lags behind its ubiquity. While occupancy modelling software has dominated the analytical landscape for eDNA data analysis of single species, this type of model may not always be the most appropriate. The rate of eDNA detection often corresponds to species density, rather than just occupancy, and researchers often have access to observations from non‐genetic sampling methods at the same sites. To provide users access to a modelling framework designed to maximize the use of all available data, we developed an R package, eDNAjoint . The package provides an easy‐to‐use interface for fitting a ‘joint’ model that integrates data from paired or semi‐paired eDNA and traditional surveys in a Bayesian framework. The model can be used to estimate parameters like the probability of a false positive eDNA detection and mean catch rate at a site, and the package allows access to multiple model variations and Bayesian prior customization. Additional functionality can be used for model selection, summarising posteriors and comparing the relative sensitivities of the two survey methods. We demonstrate the use of eDNAjoint by fitting a variation of the model with site‐level covariates that scale the sensitivity of eDNA sampling relative to traditional sampling. The example workflow uses binary eDNA and seine count data for the endangered tidewater goby ( Eucyclogobius newberryi ) from a study by Schmelzle and Kinziger (2016). This use case includes a prior sensitivity analysis and an evaluation of the relationship between detection rates and environmental variables. eDNAjoint has the potential to greatly increase the range of users who will be able to rigorously analyse eDNA and traditional survey data in a Bayesian framework, understand if and how eDNA can improve monitoring practices, and gain confidence in the interpretability of eDNA data.

Keller, Abigail G. [Department of Environment Scie↗

Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

Demonstration and Concept of Operations for a Zero-Knowledge Protocol Passive Imaging Measurement for Arms Control

Here, we present an imaging system that employs zero-knowledge protocols to protect sensitive geometrical information, along with procedures to increase confidence in the result. The goal of this work is to enable the inclusion of warhead confirmation measurements in future arms control treaties. We present a demonstration of both true positive and true negative measurements that validate models and establish authenticating procedures toward meeting acceptance requirements for use in nuclear facilities. We use a two-dimensional time-encoded fast neutron imaging system with an anti-symmetric mask pattern; the fast neutron count values exceeding minimum or maximum thresholds indicate that two measured items are not identical. Laboratory measurements over twenty trials show that alarm rates for negative confirmation measurements are within uncertainties of model predictions. Positive confirmation measurements indicate that alarm rates are large enough to encourage treaty compliance.

Sweany, Melinda Dominique [Sandia National Laborat↗

The Pixel Luminosity Telescope: a detector for luminosity measurement at CMS using silicon pixel sensors

The Pixel Luminosity Telescope is a silicon pixel detector dedicated to luminosity measurement at the CMS experiment at the LHC. It is located approximately 1.75 m from the interaction point and arranged into 16 “telescopes”, with eight telescopes installed around the beam pipe at either end of the detector and each telescope composed of three individual silicon sensor planes. The per-bunch instantaneous luminosity is measured by counting events where all three planes in the telescope register a hit, using a special readout at the full LHC bunch-crossing rate of 40 MHz. The full pixel information is read out at a lower rate and can be used to determine calibrations, corrections, and systematic uncertainties for the online and offline measurements. This paper details the commissioning, operational history, and performance of the detector during Run 2 (2015–18) of the LHC, as well as preparations for Run 3, which will begin in 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measured Thermal And Fast Neutron Fluence Rates ATR Cycle 169A

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 169A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of ( 1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, (3) plots of both the thermal and fast neutron fluence rates, and (4) an optical record (compact disk) containing a listing of the thermal and the fast neutron fluence rates, their assigned elevations and proper header identification of all monitor positions contained herein. The fluence rates reported are for the average power levels given in the table of power history and distribution. No neutron monitors were located in the N-2 position during this cycle. All "SR" holder monitor wires for this cycle are 55 inches long. This length allows measurements from 24.73 inches above core midplane to 25.25 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectra-to-exposure conversion using polynomial response models for gamma-ray field characterization

Accurate measurement of exposure rate from gamma-ray spectral data remains a critical challenge during radiological emergency response operations. Conventional methods rely on pre-defined static conversion factors derived from fixed geometries and isotopic compositions, which often fail to capture real-world environmental variability. This study presents a generalized approach as a "next-step" for converting gamma-ray spectral data into exposure rate using polynomial response models. The method introduces a flexible weighting scheme based on the in-situ detector response to distributed sources, enabling a pathway towards improved correspondence between measured spectra and "ground-truth" exposure rates. Experimental data from sodium iodide NaI(Tl) detectors were used to validate the approach as, at least equivalent to the current count-to-exposure method employed in emergency response CONOPS. Results show that the polynomial weighting model is sufficiently equal to the count-to-exposure method and may help improve accuracy given its adaptability to real-world conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

The role of quantum computing in advancing scientific high-performance computing: A perspective from the ADAC institute

Quantum computing (QC) has gained significant attention over the past two decades due to its potential for speeding up classically demanding tasks. This transition from an academic focus to a thriving commercial sector is reflected in substantial global investments. While advancements in qubit counts and functionalities continue at a rapid pace, current quantum systems still lack the scalability for practical applications, facing challenges such as too high error rates and limited coherence times. Here, this perspective paper examines the relationship between QC and high-performance computing (HPC), highlighting their complementary roles in enhancing computational efficiency. It is widely acknowledged that even fully error-corrected QC will not be suited for all computational tasks. Rather, future compute infrastructures are anticipated to employ quantum acceleration within hybrid systems that integrate HPC and QC. While QC can enhance classical computing, traditional HPC remains essential for maximizing quantum acceleration. This integration is a priority for supercomputing centers and companies, sparking innovation to address the challenges of merging these technologies. The novelty of this work lies in its unique perspective, reflecting the collective insights of the Accelerated Data Analytics and Computing (ADAC) Institute, a global consortium of over 20 leading HPC centers. Recognizing the growing importance of QC, ADAC established a Quantum Computing Working Group in 2023 to foster collaboration and knowledge-sharing among its members. This paper synthesizes insights from the group’s collaborative efforts and incorporates findings from a member survey that captures shared experiences, ongoing projects, and strategic directions. By outlining the current landscape and challenges of QC integration into HPC ecosystems, this work offers HPC specialists practical and forward-looking guidance on the opportunities and implications of QC in computationally intensive endeavors.

Accelerated Data Analytics and↗

Boundaries of quantum supremacy via random circuit sampling

Abstract Google’s quantum supremacy experiment heralded a transition point where quantum computers can evaluate a computational task, random circuit sampling, faster than classical supercomputers. We examine the constraints on the region of quantum advantage for quantum circuits with a larger number of qubits and gates than experimentally implemented. At near-term gate fidelities, we demonstrate that quantum supremacy is limited to circuits with a qubit count and circuit depth of a few hundred. Larger circuits encounter two distinct boundaries: a return of a classical advantage and practically infeasible quantum runtimes. Decreasing error rates cause the region of a quantum advantage to grow rapidly. At error rates required for early implementations of the surface code, the largest circuit size within the quantum supremacy regime coincides approximately with the smallest circuit size needed to implement error correction. Thus, the boundaries of quantum supremacy may fortuitously coincide with the advent of scalable, error-corrected quantum computing.

97 MATHEMATICS AND COMPUTING↗