Search NASA⌕ Search

SEARCH · Search NASA

Results for “Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Optimization of the N ∥ Upshift in the DIII-D high field side lower hybrid current drive experiment

High field side lower hybrid current drive (LHCD) is one potential candidate for efficient non-inductive current drive in tokamak power plants, and the first test of this technology will occur on the DIII-D tokamak during the 2024 campaign. Previous LFS launch experiments operated in the multi-pass regime and relied on scrape-off layer interactions to close the spectral gap. In the DIII-D experiment, single-pass damping is achievable via an upshift in the parallel refractive index N ∥ caused by mode converting twice (slow → fast → slow). This mode conversion affects the ray trajectories and can lead to enhanced N ∥ upshift depending on where mode conversion occurs. Compared to multi-pass absorption experiments, the optimization of launched N ∥ and plasma parameters can be counter-intuitive: increased density may increase efficiency and smaller N ∥,launch tend to damp closer to the separatrix. A hard x-ray camera installed to measure the bremsstrahlung (50–250 keV) radiation from LHCD-generated fast electrons is capable of verifying the trends reporting in this paper through comparison to the ray-tracing/Fokker–Planck codes GENRAY/CQL3D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Continuum radiated power density $(P^{\textrm{C}}_{\textrm{rad}})$ and effective charge $(Z_{\textrm{eff}})$ estimates from multi-energy photon-counting measurements

Multi-energy soft x-ray pinhole cameras have been designed, built, calibrated, and operated at Madison symmetric Torus, Alcator C-Mod, and more recently at Tokamak a configuration variable and Tungsten Environment in Steady-State Tokamak (WEST), to measure plasma emission across multiple energy ranges. Here we describe a new methodology to estimate the local continuum radiated power density and the plasma effective charge (Z eff ) directly from photon-counting measurements of the line-free continuum emission (Bremsstrahlung and Radiative Recombination) in several energy bands between 11 and 18 keV. This capability is particularly valuable for confinement systems using metal plasma-facing components, where x-ray losses from interactions with the sputtered wall can represent a significant fraction of the total radiated power (P rad ). The approach leverages a well-characterized detector responsivity, modeled by a complementary error function, and interprets the differential multi-energy measurements between adjacent energy levels through the probability density function of a Gaussian distribution. The implementation of this diagnostic technique is currently under development on the WEST tokamak, aiming at the goal of providing real-time P rad and Z eff measurements during long-pulse operation (up to 1000 s) in the 2026 campaign.

WEST↗

Mass calibration of DES Year-3 clusters via SPT-3G CMB cluster lensing

We measure the stacked lensing signal in the direction of galaxy clusters in the DarkEnergy Survey Year 3 (DES Y3) redMaPPer sample, using cosmic microwave background (CMB)temperature data from SPT-3G, the third-generation CMB camera on the South PoleTelescope (SPT). Here, we estimate the lensing signal using temperature maps constructed fromthe initial 2 years of data from the SPT-3G 'Main' survey, covering 1500 deg$^{2}$ of the Southernsky. We then use this lensing signal as a proxy for the mean cluster mass of the DES sample. Thethermal Sunyaev-Zel'dovich (tSZ) signal, which can contaminate the lensing signal if notaddressed, is isolated and removed from the data before obtaining the mass measurement. In thiswork, we employ three versions of the redMaPPer catalogue: a Flux-Limited sample containing 8865clusters, a Volume-Limited sample with 5391 clusters, and a Volume&Redshift-Limited sample with4450 clusters. For the three samples, we detect the CMB lensing signal at a significance of12.4σ, 10.5σ and 10.2σ and find the mean cluster masses to be M$_{200m}$ = 1.66±0.13 [stat.]± 0.03 [sys.], 1.97±0.18 [stat.]± 0.05 [sys.],and 2.11±0.20 [stat.]± 0.05 [sys.]×10$^{14}$ M$_{⊙}$, respectively. Thisis a factor of ∼ 2 improvement relative to the precision of measurements with previousgenerations of SPT surveys and the most constraining cluster mass measurements using CMB clusterlensing to date. Overall, we find no significant tensions between our results and masses given byredMaPPer mass-richness scaling relations of previous works, which were calibrated using CMBcluster lensing, optical weak lensing, and velocity dispersion measurements from variouscombinations of DES, SDSS and Planck data. We then divide our sample into 3 redshift and 3richness bins, finding no significant discrepancies with optical weak-lensing calibrated masses inthese bins. We forecast a 5.7% constraint on the mean cluster mass of the DES Y3 sample withthe complete SPT-3G surveys when using both temperature and polarization data and including anadditional ∼ 1400 deg$^{2}$ of observations from the 'Extended' SPT-3G survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Selection of high-redshift Lyman-Break Galaxies from broadband and wide photometric surveys

Here, in this paper, we investigate the possibility of selecting high-redshift Lyman-Break Galaxies (LBG) using current and future broadband wide photometric surveys, such as the Ultraviolet Near Infrared Optical Northern Survey (UNIONS) or the Vera C. Rubin Legacy Survey of Space and Time (LSST), using a Random Forest algorithm. This work is conducted in the context of future large-scale structure spectroscopic surveys like DESI-II, the next phase of the Dark Energy Spectroscopic Instrument (DESI), which will start around 2029. We use deep imaging data from the Hyper Suprime Camera (HSC) and the Canada-France-Hawaii Telescope Large Area U-band Deep Survey (CLAUDS) on the COSMOS and XMM-LSS fields. To predict the selection performance of LBGs with image quality similar to UNIONS, we degrade the u,g,r,i and z bands to UNIONS depth. The Random Forest algorithm is trained with the u,g,r,i and z bands to classify LBGs in the 2.5 < z < 3.5 range. We find that fixing a target density budget of 1,100 deg -2 , the Random Forest approach gives a density of z > 2 targets of 873 deg -2 , and a density of 493 deg -2 of confirmed LBGs after spectroscopic confirmation with DESI. This UNIONS-like selection was tested in a dedicated spectroscopic observation campaign of 1,000 targets with DESI on the COSMOS field, providing a safe spectroscopic sample with a mean redshift of 3. This sample is used to derive forecasts for DESI-II, assuming a sky coverage of 5,000 deg 2 . We predict uncertainties on Alcock-Paczynski parameters α ⊥ and α ∥ to be 0.7% and 1% for 2.6 < z < 3.2, resulting in a potential 2% measurement of the dark energy fraction at high redshift. Additionally, we estimate the uncertainty in local non-Gaussianity and predict σ fNL ≈ 7, which would be comparable to the current best precision achieved by Planck. The latter forecast suggests that achieving the precision required to place stringent constraints on inflationary models (σ fNL ≈ 1) using spectroscopic galaxy surveys necessitates the development of a next-generation (Stage V) spectroscopic survey.

cosmological parameters from LSS↗

The Atacama Cosmology Telescope: DR6 maps

We present Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) maps of the Cosmic Microwave Background temperature and polarization anisotropy at arcminute resolution over three frequency bands centered on 98, 150 and 220 GHz. The maps are based on data collected with the AdvancedACT camera over the period 2017–2022 and cover 19,000 square degrees with a median combined depth of 10 μK arcmin. We describe the instrument, mapmaking and map properties and illustrate them with a number of figures and tables.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full calibration of the tomographic redshift distribution from the HSC PDR3 Shape Catalog with DESI

The calibration of tomographic redshift distributionsis essential for cosmological analysis of weak lensing data.In this work, we calibrate all four tomographic bins of the Hyper Suprime Camera (HSC) weak lensing catalog with the Dark Energy Spectroscopic Instrument (DESI) Data Release 1 and 2 using the clustering redshifts technique. We include z > 1.2 redshift sources such as emission line galaxies (ELG) and quasars (QSO) sources in our calibration, which were not available in the previous HSC calibration (Rau et al. (2022), Mon. Not. Roy. Astron. Soc. 524 (2023) 5109), allowing a complete calibration of all the redshift bins. We find the first tomographic bin exhibits a small shift towards low redshifts. The second bin is in good agreement with the photometric calibration, while third and fourth bin exhibit a shift towards higher redshifts. However, these shifts are considerably smaller than the shifts obtained in the HSC Year 3 cosmic shear analyses. We evaluate the impact of galaxy bias and magnification effects from all the samples on the measurements, finding them to be small, and we propose corrections to reduce them further. Specifically, we relax the assumption of linear bias and only assume no redshift evolution of the cross-correlation coefficient, allowing us to leverage smaller clustering scales. We model the redshift distributions with splines and compare our results to previous analyses as well as to other parameterizations found in literature. For the two high-redshift tomographic bins, we find the shifts to higher redshifts with respect to the measurements performed in Rau+2022 to be Δz$_{3}$ =-0.039$^{+0.020}$$_{-0.021}$ and Δz$_{4}$ = -0.048$^{+0.012}$$_{-0.012}$.

Choppin de Janvry, J. [LBL, Berkeley; UC, Berkeley↗

Overview of fast particle experiments in the first MAST Upgrade experimental campaigns

Abstract MAST-U is equipped with on-axis and off-axis neutral beam injectors (NBI), and these external sources of super-Alfvénic deuterium fast-ions provide opportunities for studying a wide range of phenomena relevant to the physics of alpha-particles in burning plasmas. The MeV range D-D fusion product ions are also produced but are not confined. Simulations with the ASCOT code show that up to 20% of fast ions produced by NBI can be lost due to charge exchange (CX) with edge neutrals. Dedicated experiments employing low field side (LFS) gas fuelling show a significant drop in the measured neutron fluxes resulting from beam-plasma reactions, providing additional evidence of CX-induced fast-ion losses, similar to the ASCOT findings. Clear evidence of fast-ion redistribution and loss due to sawteeth (ST), fishbones (FB), long-lived modes (LLM), Toroidal Alfvén Eigenmodes (TAE), Edge Localised Modes (ELM) and neoclassical tearing modes (NTM) has been found in measurements with a Neutron Camera (NCU), a scintillator-based Fast-Ion Loss Detector (FILD), a Solid-State Neutral Particle Analyser (SSNPA) and a Fast-Ion Deuterium- α (FIDA) spectrometer. Unprecedented FILD measurements in the range of 1–2 MHz indicate that fast-ion losses can be also induced by the beam ion cyclotron resonance interaction with compressional or global Alfvén eigenmodes (CAEs or GAEs). These results show the wide variety of scenarios and the unique conditions in which fast ions can be studied in MAST-U, under conditions that are relevant for future devices like STEP or ITER.

Physics↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Plasma modification through boron particulate injection in the full tungsten environment of WEST

Recent experiments have confirmed the compatibility of extended boron particulate injections with high performance plasma discharges in the full tungsten (W) environment of WEST. Utilizing an impurity powder dropper (IPD) equipped with boron (B) powders a series of extended experimental programs providing controlled injections have quantified plasma response to varying levels of injection rate and total injection quantity. Calibration of injection quantities confirmed through post-situ testing of the IPD and cross-correlated with both high-speed camera illumination and spectroscopic measurement have allowed for the first time a fine scale determination of the effects of powder introduction on plasma performance. Plasma enhancement, consistent with turbulence reduction through profile modification, has been observed with sustained increases in the stored energy (WMHD), by 18%, electron temperature (T e ) by 35%, and neutron rate (N n ) by up to 200%, all of which scale positively with increasing powder injection rates. These injections have also resulted in both prompt and extended reductions in native impurity content, decreases in post injection radiated power, and strong decreases in divertor deuterium signatures signifying a reduction in recycling suggesting enhanced boron layer formation which provides a reduction of source terms and leads to enhanced gettering of main ion and impurity sources.

Lunsford, R. [Princeton Plasma Physics Laboratory ↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

Regulation compliant AI for fusion: explainable image-based feedback control of divertor detachment in DIII-D tokamak

While artificial intelligence (AI) has been promising for fusion control, its inherent black-box nature will make compliant implementation in regulatory environments a challenge. This study implements and validates a real-time AI-enabled linear and interpretable control system for successful divertor detachment control with the DIII-D lower divertor camera. Using D 2 gas, we demonstrate successful feedback divertor detachment control with a mean absolute difference of 2% from the target for both detachment and reattachment. This automatic training and linear processing framework can be extended to any image-based diagnostic for future fusion reactors.

computer vision↗

Comparison of plasma response models for RMP effects on the divertor and scrape-off layer in KSTAR

Resonant magnetic perturbations (RMPs) are beneficial for control of edge localized modes (ELMs) in tokamaks. Nevertheless, a side effect of RMPs is the appearance of helical striations in the particle and heat loads onto divertor targets. The extent and field line connection of these striations is significantly altered by the plasma response to external perturbations. For an ELM suppressed high confinement (H-mode) plasma at KSTAR, magnetic footprints are computed by FLARE based on plasma response from GPEC, MARS-F, M3D-C1 and JOREK with substantial differences in the resulting footprints (from 2 cm to 14 cm). This is reflected in EMC3-EIRENE simulations of the resulting heat loads: it is found that either the peak value or the extent of the striations appears to be overestimated compared to infrared camera measurements. Reasonable agreement can only be achieved for the smallest footprint for lower input power and lower cross-field transport, or for higher upstream density and radiative power losses.

Frerichs, H. [Univ. of Wisconsin, Madison, WI (Uni↗

Design improvements to the SNS ion source and diagnostics

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed-neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. The accelerator system is fed by an RF-driven, multicusp, H - ion source which nominally provides pulsed beam currents of 50-60 mA (1ms, 60Hz). This report provides a discussion of ongoing design improvements to the SNS ion source and Low Energy Beam Transport (LEBT) as well as diagnostic upgrades undertaken since the previous ICIS conference. These improvements include (i) simple mechanical modifications to the source outlet aperture which resulted in dramatically increased extracted beam current and comparable or lower emittance at similar beam currents, (ii) design improvements to the LEBT chopper target which will enable full power beam-dumping during physics studies, (iii) refinement of the SNS Allison emittance scanner that has enabled the first reliable LEBT beam measurements at full beam power (65kV, 50-100mA, 1ms, 60Hz) on the SNS ion source test stand and (iv) the implementation of a thermal imaging camera for the monitoring the LEBT electrode temperatures. (v) The design of an advanced Cs system, capable of more efficient Cs utilization with significantly lower Cs losses from the source is also presented. Mechanical details, computational simulations and experimental results are discussed within the context of these improvements.

47 OTHER INSTRUMENTATION↗

A modular GUI-based program for genetic algorithm-based feedback-assisted wavefront shaping

Abstract We have developed a modular graphical user interface (GUI)-based program for use in genetic algorithm-based feedback-assisted wavefront shaping. The program uses a class-based structure to separate out the universal modules (e.g. GUI, multithreading, optimization algorithms) and hardware-specific modules (e.g. code for different SLMs and cameras). This modular design makes the program easily adaptable to a wide range of lab equipment, while providing easy access to a GUI, multithreading, and three optimization algorithms (phase-stepping, simple genetic, and microgenetic).

97 MATHEMATICS AND COMPUTING↗

Seasonal changes in occupancy and activity patterns in native Collared Peccary and non-native wild pig and Common Warthog in southern Texas, the United States

Abstract Southern Texas, USA, is home to native collared peccaries (Dicotyles tajacu) and introduced populations of invasive wild pigs (generally Sus scrofa × domesticus hybrids) and non-native African warthogs (Phacochoerus africanus). Although these ecologically similar mammals co-occur in this region, the potential impacts of invasive suids on collared peccaries are poorly understood. We examined co-occupancy and activity pattern overlap of collared peccaries, wild pigs, and warthogs across 3 seasons (fall, winter, and spring) using remote camera data collected from Chaparral Wildlife Management Area, Cotulla, Texas (November 2020 to June 2021). Using activity pattern analyses and single and 2-species occupancy models incorporating habitat and climate characteristics, we found evidence of extensive spatial overlap between all species pairs and varying degrees of temporal overlap depending on species pairs and season. Collared peccaries and wild pigs displayed moderate temporal overlap across all seasons. Collared peccaries appeared to alter fall activity in the presence of wild pigs to be active earlier in the morning and less active during the day. Collared peccaries and warthogs had low-to-moderate temporal overlap (low in fall, winter; moderate in spring). Wild pigs and warthogs had low temporal overlap (fall, spring) and wild pigs appeared to alter activity in the presence of warthogs (fall), becoming less active during the day during peak warthog activity. Overall, our results suggest that peccary, wild pig, and warthog interactions and activity are dynamic and vary seasonally according to the ecology and preferred environmental conditions of each species. Given the potential for interspecific competition and disease transmission with Collared Peccary and other native wildlife, resource partitioning between wild pigs and warthogs needs to be further examined to aid in effective management strategies.

Kupferman, Caitlin A. (ORCID:0009000953554860)↗

Deep drilling in the time domain with DECam – II: characterizing the light curves of candidates in the extragalactic fields

ABSTRACT In this second paper on the DECam deep-drilling field (DDF) program, we release 2020 optical $gri$-band light curves for transients and variables in the extragalactic COSMOS and ELAIS fields based on time series observations with a 3-d cadence from semester 2021A through 2023A. In order to demonstrate the wide variety of time domain events detected by the program and encourage others to use the data set, we characterize the sample by presenting a brief analysis of the light-curve parameters such as time span, amplitude, and peak brightness. We also present preliminary light-curve categorizations, and identify potential stellar variables, active galactic nuclei, tidal disruption events, supernovae (SNe) (such as Type Ia, Type IIP, superluminous, and gravitationally lensed SNe), and fast transients. Where relevant, the number of identified transients is compared to the predictions of the original proposal. We also discuss the challenges of analyzing DDF data in the context of the upcoming Vera C. Rubin Observatory and its Legacy Survey of Space and Time, which will include DDFs. Images from the Dark Energy Camera DDF program are available without proprietary period and the light curves presented in this work are publicly available for analysis.

Graham, Melissa L. (ORCID:0000000291543136)↗

Effect of the space weather conditions on the Earth magnetosphere soft X-ray emissivity

The aim of the study is to model and characterize the soft X-ray emissivity on the Earth magnetosphere for different space weather conditions (SWC), providing information to interpret the soft X-ray measurements of the Solar wind Magnetosphere Ionosphere Link Explorer space mission. The MHD code pluto in spherical coordinates is used to perform parametric studies with respect to the solar wind (SW) dynamic pressure (considering density and velocity effects independently) as well as the IMF intensity and orientation, predicting the soft X-ray emissivity for different SWC. The integrated soft X-ray emissivity inside the magnetosheath is calculated as a proxy of the soft X-ray emission dependencies with the SWC independently of the satellite orbit and camera line of sight. The analysis indicates fluctuations of the interplanetary magnetic field (IMF) orientation and magnitude may significantly affect the measured soft X-ray emission although changes in the SW dynamic pressure should be the main source of variability. The southward IMF orientation leads to the configuration with the largest soft X-ray emissivity and northward to the lowest. Strongly distorted magnetospheres explored in configurations showing SW and IMF parameters comparable to the impact of interplanetary coronal mass ejections may show a decrease of the soft X-ray emissivity as the IMF magnitude increases, explained by the strong magnetosphere compression and constriction of the magnetosheath region where the soft X-ray emissivity maximum is located. The simulations also indicate large excursions of the soft X-ray emissivity maximum inside the magnetosheath as the IMF magnitude and SW dynamic pressure fluctuate particularly for radial and ecliptic IMF orientations.

Earth↗

DAmodel: hierarchical Bayesian modelling of DA white dwarfs for spectrophotometric calibration

We use hierarchical Bayesian modelling to calibrate a network of 32 all-sky faint DA white dwarf (DA WD) spectrophotometric standards (⁠16.5 < V , 19.5⁠) alongside three CALSPEC standards, from 912 Å to 32 μm. The framework is the first of its kind to jointly infer photometric zero points and WD parameters (surface gravity log g⁠, effective temperature T eff ⁠, extinction A V ⁠, dust relation parameter R V ) by simultaneously modelling both photometric and spectroscopic data. We model panchromatic Hubble Space Telescope Wide Field Camera 3 (HST/WFC3) UVIS and IR photometry, HST/STIS UV spectroscopy, and ground-based optical spectroscopy to sub-per cent precision. Photometric residuals for the sample are the lowest yet yielding < 0.004 mag RMS on average from the UV to the NIR, achieved by jointly inferring time-dependent changes in system sensitivity and WFC3/IR count-rate nonlinearity. Our GPU-accelerated implementation enables efficient sampling via Hamiltonian Monte Carlo, critical for exploring the high-dimensional posterior space. The hierarchical nature of the model enables population analysis of intrinsic WD and dust parameters. Inferred spectral energy distributions from this model will be essential for calibrating the James Webb Space Telescope as well as next-generation surveys, including Vera Rubin Observatory’s Legacy Survey of Space and Time and the Nancy Grace Roman Space Telescope.

methods: statistical↗