Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cherenkov”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Charged Kaon Mass Measurement using the Cherenkov Effect

The two most recent and precise measurements of the charged kaon mass use X-rays from kaonic atoms and report uncertainties of 14 ppm and 22 ppm yet differ from each other by 122 ppm. We describe the possibility of an independent mass measurement using the measurement of Cherenkov light from a narrow-band beam of kaons, pions, and protons. This technique was demonstrated using data taken opportunistically by the Main Injector Particle Production experiment at Fermi National Accelerator Laboratory which recorded beams of protons, kaons, and pions ranging in momentum from +37 GeV/c to +63 GeV/c. The measured value is 491.3 {+-} 1.7 MeV/c{sup 2}, which is within 1.4{sigma} of the world average. An improvement of two orders of magnitude in precision would make this technique useful for resolving the ambiguity in the X-ray data and may be achievable in a dedicated experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark matter substructure modelling and sensitivity of the Cherenkov Telescope Array to Galactic dark halos

Hierarchical structure formation leads to a clumpy distribution of dark matter in the Milky Way. These clumps are possible targets to search for dark matter annihilation with present and future γ-ray instruments. Many uncertainties exist on the clump distribution, leading to disputed conclusions about the expected number of detectable clumps and the ensuing limits that can be obtained from non-detection. In this paper, we use the CLUMPY code to simulate thousands of skymaps for several clump distributions. This allows us to statistically assess the typical properties (mass, distance, angular size, luminosity) of the detectable clumps. Varying parameters of the clump distributions allows us to identify the key quantities to which the number of detectable clumps is the most sensitive. Focusing our analysis on two extreme clump configurations, yet consistent with results from numerical simulations, we revisit and compare various calculations made for the Fermi -LAT instrument, in terms of number of dark clumps expected and the angular power spectrum for the Galactic signal. We then focus on the prospects of detecting dark clumps with the future CTA instrument, for which we make a detailed sensitivity analysis using open-source CTA software. Based on a realistic scenario for the foreseen CTA extragalactic survey, and accounting for a post-trial sensitivity in the survey, we show that we obtain competitive and complementary limits to those based on long observation of a single bright dwarf spheroidal galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation studies of the high-energy component of a future imaging Cherenkov telescope array

The current generation of Imaging Atmospheric telescopes (IACTs) has demonstrated the power of the technique in an energy range between {approx}100 GeV up to several tens of TeV. At the high-energy end, these instruments are limited by photon statistics. Future arrays of IACTs such as CTA or AGIS are planned to push into the energy range beyond 100 TeV. Scientifically, this region is very promising, providing a probe of particles up to the 'knee' in the cosmic ray spectrum and access to an unexplored region in the spectra of nearby extragalactic sources. We present first results from our simulation studies of the high-energy part of a future IACT array and discuss the design parameters of such an array.

79 ASTRONOMY AND ASTROPHYSICS↗

Superradiant Ka-band Cherenkov oscillator with 2-GW peak power

The generation of a 2-GW microwave superradiance (SR) pulses has been demonstrated at 29-GHz using a single-mode relativistic backward-wave oscillator possessing the beam-to-wave power conversion factor no worse than 100%. A record-breaking radiation power density in the slow-wave structure (SWS) of ∼1.5 GW/cm{sup 2} required the use of high guiding magnetic field (7 T) decreasing the beam losses to the SWS in strong rf fields. Despite the field strength at the SWS wall of 2 MV/cm, a single-pass transmission mode of a short SR pulse in the SWS allows one to obtain extremely high power density in subnanosecond time scale due to time delay in the development of the breakdown phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron tagging following atmospheric neutrino events in a water Cherenkov detector

We present the development of neutron-tagging techniques in Super-Kamiokande IV using a neural network analysis. The detection efficiency of neutron capture on hydrogen is estimated to be 26%, with a mis-tag rate of 0.016 per neutrino event. The uncertainty of the tagging efficiency is estimated to be 9.0%. Measurement of the tagging efficiency with data from an Americium-Beryllium calibration agrees with this value within 10%. The tagging procedure was performed on 3,244.4 days of SK-IV atmospheric neutrino data, identifying 18,091 neutrons in 26,473 neutrino events. The fitted neutron capture lifetime was measured as 218±9 μs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Picosecond timing of microwave Cherenkov impulses from high-energy particle showers using dielectric-loaded waveguides

Here, we report on the first measurements of coherent microwave impulses from high-energy particle-induced electromagnetic showers generated via the Askaryan effect in a dielectric-loaded waveguide. Bunches of 12.16 GeV electrons with total bunch energy of ∼10 3 – 10 4 GeV were preshowered in tungsten, and then measured with WR-51 rectangular (12.6 mm by 6.3 mm) waveguide elements loaded with solid alumina (Al 2⁢ O 3 ) bars. In the 5–8 GHz 𝑇⁢𝐸 10 single-mode band determined by the presence of the dielectric in the waveguide, we observed band-limited microwave impulses with amplitude proportional to bunch energy. Signals in different waveguide elements measuring the same shower were used to estimate relative time differences with 2.3 ps precision. These measurements establish a basis for using arrays of alumina-loaded waveguide elements, with exceptional radiation hardness, as very high precision timing planes for high-energy physics detectors.

43 PARTICLE ACCELERATORS↗

Search for Proton Decay via p{yields}e{sup +}{pi}{sup 0} and p{yields}{mu}{sup +}{pi}{sup 0} in a Large Water Cherenkov Detector

We have searched for proton decays via p{yields}e{sup +}{pi}{sup 0} and p{yields}{mu}{sup +}{pi}{sup 0} using data from a 91.7 kt{center_dot}yr exposure of Super-Kamiokande-I and a 49.2 kt{center_dot}yr exposure of Super-Kamiokande-II. No candidate events were observed with expected backgrounds induced by atmospheric neutrinos of 0.3 events for each decay mode. From these results, we set lower limits on the partial lifetime of 8.2x10{sup 33} and 6.6x10{sup 33} years at 90% confidence level for p{yields}e{sup +}{pi}{sup 0} and p{yields}{mu}{sup +}{pi}{sup 0} modes, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Clear Fiber Cherenkov Counter

We have developed a new PID detector consists of clear fibers. PID efficiency was measured with 470 MeV e{sup +} beam. As a result, this detector with thickness of 5 cm has the PID efficiency of 95 %. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

About compensation the electronic beam dynamic stratification influence in super-power relativistic Cherenkov oscillators

On the basis of the exact nonlinear theory relativistic TWT and BWO on irregular hollow waveguides with cathode filters-modulators with the account as propagating, and beyond cut-off waves, with the account of losses in walls of a waveguide and inhomogeneity directing an electronic beam magnetostatic fields finds out influence of dynamic stratification influence on efficiency of the generator. Possibility of almost fill compensation the electronic beam dynamic stratification influence on efficiency by optimization of an electronic beam arrangement in inhomogeneous high frequency and magnetic fields and characteristics of the irregular corrugated waveguide is shown. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗