Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cleaned”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

State of the States 2010: The Role of Policy in Clean Energy Market Transformation

This report builds on the emerging body of literature seeking to identify quantitative connections between clean energy policy and renewable energy. The methods presented test the relationships between a broad set of policies and clean energy resources (energy efficiency, biomass, geothermal, solar, and wind). Energy efficiency findings are an initial foray into this type of analysis and indicatesignificant connections between reduced energy use and buildings codes, energy efficiency resource standards (in some cases), and electricity price. Renewable energy findings specify that there is most often a relationship between state policies and solar and wind development, indicating that while policies might apply to a wide variety of renewable resources, further tailoring of policyspecifics to resource needs may lead to increased development of a wider variety of renewable energy resources. Further research is needed to refine the connections between clean energy development and policy, especially in the area of the impact of the length of time that a policy has been in place.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ANALYSIS OF SAMPLES FROM TANK 6F CHEMICAL CLEANING

Savannah River Remediation (SRR) is preparing Tank 6F for closure. The first step in preparing the tank for closure is mechanical sludge removal. In mechanical sludge removal, personnel add liquid (e.g., inhibited water or supernate salt solution) to the tank to form a slurry. They mix the liquid and sludge with pumps, and transfer the slurry to another tank for further processing. Mechanical sludge removal effectively removes the bulk of the sludge from a tank, but is not able to remove all of the sludge. In Tank 6F, SRR estimated a sludge heel of 5,984 gallons remained after mechanical sludge removal. To remove this sludge heel, SRR performed chemical cleaning. The chemical cleaning included two oxalic acid strikes, a spray wash, and a water wash. SRR conducted the first oxalic acid strike as follows. Personnel added 110,830 gallons of 8 wt % oxalic acid to Tank 6F and mixed the contents of Tank 6F with two submersible mixer pumps (SMPs) for approximately four days. Following the mixing, they transferred 115,903 gallons of Tank 6F material to Tank 7F. The SMPs were operating when the transfer started and were shut down approximately five hours after the transfer started. SRR collected a sample of the liquid from Tank 6F and submitted it to SRNL for analysis. Mapping of the tank following the transfer indicated that 2,400 gallons of solids remained in the tank. SRR conducted the second oxalic acid strike as follows. Personnel added 28,881 gallons of 8 wt % oxalic acid to Tank 6F. Following the acid addition, they visually inspected the tank and transferred 32,247 gallons of Tank 6F material to Tank 7F. SRR collected a sample of the liquid from Tank 6F and submitted it to SRNL for analysis. Mapping of the tank following the transfer indicated that 3,248 gallons of solids remained in the tank. Following the oxalic acid strikes, SRR performed Spray Washing with oxalic acid to remove waste collected on internal structures, cooling coils, tank top internals, and tank walls. The Acid Spray Wash was followed by a Water Spray Wash to remove oxalic acid from the tank internals. SRR conducted the Spray Wash as follows. Personnel added 4,802 gallons of 8 wt % oxalic acid to Tank 6F through the spray mast installed in Riser 2, added 4,875 gallons of oxalic acid through Riser 7, added 5,000 gallons of deionized water into the tank via Riser 2, and 5,000 gallons of deionized water into the tank via Riser 7. Following the Spray Wash, they visually inspected the tank and transferred 22,430 gallons of Tank 6F material to Tank 7F. SRR collected a sample of the liquid from Tank 6F and submitted it to SRNL for analysis. Following the Spray Wash and transfer, Savannah River Site (SRS) added 113,935 gallons of well water to Tank 6F. They mixed the tank contents with a single SMP and transferred 112,699 gallons from Tank 6F to Tank 7F. SRR collected a sample of the liquid from Tank 6F and submitted to SRNL for analysis. Mapping of the tank following the transfer indicated that 3,488 gallons of solids remained in the tank. Following the Water Wash, SRR personnel collected a solid sample and submitted it to SRNL for analysis to assess the effectiveness of the chemical cleaning and to provide a preliminary indication of the composition of the material remaining in the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TREATMENT TANK OFF-GAS TESTING FOR THE ENHANCED CHEMICAL CLEANING PROCESS

The purpose of this activity was to provide a bounding estimate of the volume of hydrogen gas generated during Enhanced Chemical Cleaning (ECC) of residual sludge remaining in a Type I or Type II treatment tank as well as to provide results independent of the sludge volume in the waste tank to be cleaned. Previous testing to support Chemical Cleaning was based on a 20:1 oxalic acid to sludge ratio. Hydrogen gas evolution is the primary safety concern. Sealed vessel coupon tests were performed to estimate the hydrogen generation rate due to corrosion of carbon steel by 2.5 wt.% oxalic acid. These tests determined the maximum instantaneous hydrogen generation rate, the rate at which the generation rate decays, and the total hydrogen generated. These values were quantified based on a small scale methodology similar to the one described in WSRC-STI-2007-00209, Rev. 0. The measured rates support identified Safety Class functions. The tests were performed with ASTM A285 Grade C carbon steel coupons. Bounding conditions were determined for the solution environment. The oxalic acid concentration was 2.5 wt.% and the test temperature was 75 C. The test solution was agitated and contained no sludge simulant. Duplicate tests were performed and showed excellent reproducibility for the hydrogen generation rate and total hydrogen generated. The results showed that the hydrogen generation rate was initially high, but decayed rapidly within a couple of days. A statistical model was developed to predict the instantaneous hydrogen generation rate as a function of exposure time by combining both sets of data. An upper bound on the maximum hydrogen generation rate was determined from the upper 95% confidence limit. The upper bound confidence limit for the hydrogen generation rate is represented by the following equation. ln (G{sub v}) = -8.22-0.0584 t + 0.0002 t{sup 2}. This equation should be utilized to estimate the instantaneous hydrogen generation rate per unit surface area, G{sub v}, at a given time, t. The units for G{sub v} and t are ft{sup 3}/ft{sup 2}/min and hours, respectively. The total volume of hydrogen gas generated during the test was calculated from the model equation. An upper bound on the total gas generated was determined from the upper 95% confidence limit. The upper bound limit on the total hydrogen generated during the 163 hour test was 0.332 ft{sup 3}/ft{sup 2}. The maximum instantaneous hydrogen generation rate for this scenario is greater than that previously measured in the 8 wt.% oxalic acid tests due to both the absence of sludge in the test (i.e., greater than 20:1 ratio of acid to sludge) and the use of polished coupons (vs. mill scale coupons). However, due to passivation of the carbon steel surface, the corrosion rate decays by an order of magnitude within the first three days of exposure such that the instantaneous hydrogen generation rates are less than that previously measure in the 8 wt.% oxalic acid tests. While the results of these tests are bounding, the conditions used in this study may not be representative of the ECC flowsheet, and the applicability of these results to the flowsheet should be evaluated for the following reasons: (1) The absence of sludge results in higher instantaneous hydrogen generation rates than when the sludge is present; and (2) Polished coupons do not represent the condition of the carbon steel interior of the tank, which are covered with mill scale. Based on lower instantaneous corrosion rates measured on mill scale coupons exposed to oxalic acid, lower instantaneous hydrogen generation rates are expected for the tank interior than measured on the polished coupons. Corrosion rates were determined from the coupon tests and also calculated from the measured hydrogen generation rates. Excellent agreement was achieved between the time averaged corrosion rate calculated from the hydrogen generation rates and the corrosion rates determined from the coupon tests. The corrosion rates were on the order of 18 to 28 mpy. Good agreement was also observed between the maximum instantaneous corrosion rate as calculated from the hydrogen generation rate and the corrosion rate determined by previous electrochemical tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Clean Cities 2012 Annual Metrics Report

The U.S. Department of Energy's (DOE) Clean Cities program advances the nation's economic, environmental, and energy security by supporting local actions to cut petroleum use in transportation. A national network of nearly 100 Clean Cities coalitions brings together stakeholders in the public and private sectors to deploy alternative and renewable fuels, idle-reduction measures, fuel economy improvements, and new transportation technologies, as they emerge. Each year DOE asks Clean Cities coordinators to submit annual reports of their activities and accomplishments for the previous calendar year. Data and information are submitted via an online database that is maintained as part of the Alternative Fuels Data Center (AFDC) at the National Renewable Energy Laboratory (NREL). Coordinators submit a range of data that characterizes the membership, funding, projects, and activities of their coalitions. They also submit data about sales of alternative fuels, deployment of alternative fuel vehicles (AFVs) and hybrid electric vehicles (HEVs), idle-reduction initiatives, fuel economy activities, and programs to reduce vehicle miles traveled (VMT). NREL analyzes the data and translates them into petroleum-use reduction impacts, which are summarized in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Materials Science Clean Room Facility at Tulane University (Final Technical Report)

The project involves conversion of a 3,000 sq. ft. area into a clean room facility for materials science research. It will be accomplished in phases. Phase I will involve preparation of the existing space, acquisition and installation of clean room equipped with a pulsed laser deposition (PLD) processing system, and conversion of ancillary space to facilitate the interface with the clean room. From a capital perspective, Phases II and III will involve the acquisition of additional processing, fabrication, and characterization equipment and capabilities.

36 MATERIALS SCIENCE↗

State of the States 2010: The Role of Policy in Clean Energy Market Transformation

This report builds on the emerging body of literature seeking to identify quantitative connections between clean energy policy and renewable energy. The methods presented test the relationships between a broad set of policies and clean energy resources (energy efficiency, biomass, geothermal, solar, and wind). Energy efficiency findings are an initial foray into this type of analysis and indicate significant connections between reduced energy use and buildings codes, energy efficiency resource standards (in some cases), and electricity price. Renewable energy findings specify that there is most often a relationship between state policies and solar and wind development, indicating that while policies might apply to a wide variety of renewable resources, further tailoring of policy specifics to resource needs may lead to increased development of a wider variety of renewable energy resources. Further research is needed to refine the connections between clean energy development and policy, especially in the area of the impact of the length of time that a policy has been in place.

09 BIOMASS FUELS↗

Clean Energy in City Codes: A Baseline Analysis of Municipal Codification across the United States

Municipal governments in the United States are well positioned to influence clean energy (energy efficiency and alternative energy) and transportation technology and strategy implementation within their jurisdictions through planning, programs, and codification. Municipal governments are leveraging planning processes and programs to shape their energy futures. There is limited understanding in the literature related to codification, the primary way that municipal governments enact enforceable policies. The authors fill the gap in the literature by documenting the status of municipal codification of clean energy and transportation across the United States. More directly, we leverage online databases of municipal codes to develop national and state-specific representative samples of municipal governments by population size. Our analysis finds that municipal governments with the authority to set residential building energy codes within their jurisdictions frequently do so. In some cases, communities set codes higher than their respective state governments. Examination of codes across the nation indicates that municipal governments are employing their code as a policy mechanism to address clean energy and transportation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Clean Cities 2015 Annual Metrics Report

The U.S. Department of Energy's (DOE's) Clean Cities program advances the nation's economic, environmental, and energy security by supporting local actions to cut petroleum use and greenhouse gas (GHG) emissions in transportation. A national network of nearly 100 Clean Cities coalitions, whose territory covers 80% of the U.S. population, brings together stakeholders in the public and private sectors to deploy alternative and renewable fuels, idle-reduction (IR) measures, fuel economy improvements, and new transportation technologies as they emerge. Each year, DOE asks Clean Cities coordinators to submit annual reports of their activities and accomplishments for the previous calendar year. Progress reports and information are submitted online as a function of the Alternative Fuels Data Center (AFDC) at the National Renewable Energy Laboratory (NREL). Coordinators report a range of information that characterize the membership, funding, projects, and activities of their coalitions. They also document activities in their region related to the development of refueling/charging infrastructure, sales of alternative fuels; deployment of alternative fuel vehicles (AFVs), plug-in electric vehicles (PEVs), hybrid electric vehicles (HEVs), and plug-in hybrid electric vehicles (PHEVs); idle reduction initiatives; fuel economy improvement activities; and programs to reduce vehicle miles traveled (VMT). NREL analyzes the data and translates them into petroleum-use and GHG emission reduction impacts, which are summarized in this report.

33 ADVANCED PROPULSION SYSTEMS↗

Clean Energy Manufacturing Analysis Center Benchmark Report: Framework and Methodologies

This report documents the CEMAC methodologies for developing and reporting annual global clean energy manufacturing benchmarks. The report reviews previously published manufacturing benchmark reports and foundational data, establishes a framework for benchmarking clean energy technologies, describes the CEMAC benchmark analysis methodologies, and describes the application of the methodologies to the manufacturing of four specific clean energy technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Clean Cities Coalitions: 2016 Activity Report

The U.S. Department of Energy's (DOE's) national network of Clean Cities Coalitions advance the nation's economic, environmental, and energy security by supporting local actions to promote the use of domestic fuels within transportation. The nearly 100 Clean Cities coalitions, whose territory covers 80% of the U.S. population, bring together stakeholders in the public and private sectors to use alternative and renewable fuels, idle-reduction (IR) measures, fuel economy improvements, and new transportation technologies as they emerge. To ensure success, coalitions leverage a robust set of expert resources and tools provided by national laboratories and DOE. Each year, Clean Cities coordinators submit annual reports of their activities and accomplishments for the previous calendar year. Data and information are submitted via an online tool that is maintained as part of the Alternative Fuels Data Center (AFDC) at the National Renewable Energy Laboratory (NREL). Coordinators submit a range of data that characterize the membership, funding, projects, and activities of their coalitions. They also submit data about sales of alternative fuels; use of alternative fuel vehicles (AFVs), plug-in electric vehicles (PEVs), and hybrid electric vehicles (HEVs); IR initiatives; fuel economy improvement activities; and programs to reduce vehicle miles traveled (VMT). NREL analyzes the submitted data to determine how broadly energy use in the U.S. has shifted due to coalition activities, which are summarized in this report.

2016 metrics↗

Clean Cities Coalitions (2018 Activity Report)

Clean Cities coalition activities resulted in an energy use impact (EUI) of over 1 billion gasoline-gallons equivalent (GGE), comprised of net alternative fuels used and energy savings from efficiency projects, in 2018. Participation in vehicle and infrastructure development projects remained strong, as did alternative fuel use and resulting overall EUI. Clean Cities coalition activities reduce emissions as they impact energy use. Coalition-reported activities prevented 5 million carbon dioxide-equivalent tons of emissions (only greenhouse gas [GHG] emissions are reported here; criteria pollutants and other emissions are not included in this report). Coalitions were successful in securing project grant awards from numerous (non-DOE) outside sources. For other Federal, State, and local agencies and private sector foundations, see funding section on page 25. The 84 project grant awards in 2018 generated $251 million in funds from coalition members and project partners along with $1.9 million in DOE grant funds. Coalitions also collected $1.1 million in stakeholder dues and $2.9 million in operational funds from host organizations. In macro terms, this supplemental funding represents nearly a 7:1 leveraging of the $37.8 million that was included in the VTO Technology Integration budget in Fiscal Year 2018. Clean Cities coordinators spent nearly 121,000 hours pursuing their coalitions' goals in 2018. The average coordinator is quite experienced and has held his or her position for at least eight years. Coordinators logged more than 3,805 outreach, education, and training activities in 2018, which reached an estimated 35 million people.

33 ADVANCED PROPULSION SYSTEMS↗

Integration of Clean Energy into Oil Field Operations

Integrating clean energy into oil and gas operations could reduce emissions and maximize higher-value use of produced hydrocarbons. In this published study, analysts from the Joint Institute for Strategic Energy Analysis (JISEA) and the National Renewable Energy Laboratory (NREL) evaluated clean power technologies for an oil field in the Delaware Basin using NREL’s Renewable Energy Integration and Optimization, or REopt, tool. The analysts evaluated different configurations of distributed energy resources based on the technologies available and the load they could satisfy, available land, and hypothetical carbon pricing. The analysis is part of a collaborative program with industry to understand site-specific energy consumption and prices in the oil and gas supply chain and determine under what conditions clean energy options are economically attractive. This work was sponsored by a consortium including ConocoPhillips, Baker Hughes, Extraction Oil & Gas, Kinder Morgan, and the Interstate Natural Gas Association of America Foundation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Clean Cities: A Model of Collaborative Technology Innovation Built Over 30 Years

The Clean Cities Coalition Network is an example of successful government-sponsored efforts to reduce petroleum use and facilitate collaborative governance across sectors and levels of government within the transportation sector. In 1993, under what is now the Vehicle Technologies Office (VTO), the U.S. Department of Energy (DOE) established Clean Cities in response to a requirement in the Energy Policy Act (EPAct) of 1992 to implement voluntary alternative fuel deployment activities. VTO's Technology Integration Program is responsible for the Clean Cities Coalition Network and many other activities. DOE created a collaborative governance effort that has translated higher-level policy goals into multiple local collaborative practices for more than 30 years.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Clean Energy Cybersecurity Accelerator Cohort 1: Authentication and Authorization

In the 2023 National Cybersecurity Strategy, the Biden-Harris Administration defines the need for a "defensible, resilient digital ecosystem where it is costlier to attack systems than defend them." The strategy cites the Clean Energy Cybersecurity Accelerator (CECA) as an exemplary effort to bolster the security and resilience of clean energy generation. These efforts help "secure the clean energy grid of the future and [generate] security best practices that extend to other critical infrastructure sectors" and promise broad and far-reaching impacts to bridge the capabilities of private industry and the needs of energy production. Cohort 1 of CECA launched in the fall of 2022 with a focus on solutions that provide strong authentication and authorization for industrial control systems to mitigate attacks on the energy grid. Authentication and authorization verify that the identity (authentication) and permissions (authorization) of a user or device are aligned with their assigned roles. Weaknesses in either can have serious repercussions. To assess the strength of Cohort 1's solutions, CECA devised threat scenarios grounded in historical precedents: the CECA team reviewed exploits from real-world case studies of state-sponsored actors to match the assessment's attack paths and targets. Cohort 1 results provided the energy industry, product vendors, and related agencies valuable insights into the efficacy and applicability of solutions in common system configurations under realistic threat scenarios. The results of the assessment highlight points for interrogation and improvement in subsequent technology iterations. CECA's evaluations are part of an ongoing conversation and collaboration to bolster U.S. cyber resilience against adversaries today and in the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Evaluation Framework for State Energy Offices' Energy Efficiency and Clean Energy Workforce Programs

Historic levels of funding for energy efficiency and clean energy projects from the Bipartisan Infrastructure Law and Inflation Reduction Act will be flowing through State Energy Offices (SEOs) in the coming years, including funds specifically for supporting workforce development efforts. This report offers a workforce evaluation framework that they can use to track and measure the progress, performance, and effectiveness of energy efficiency and clean energy workforce programs that they fund and/or implement. This evaluation step is essential to ensuring that SEOs' workforce efforts remain relevant to the evolving needs of the energy efficiency and clean energy sector and advance a workforce that is inclusive and diverse thus maximizing the success of their programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

State Clean Energy Policies Analysis (SCEPA): State Tax Incentives

As a policy tool, state tax incentives can be structured to help states meet clean energy goals. Policymakers often use state tax incentives in concert with state and federal policies to support renewable energy deployment or reduce market barriers. This analysis used case studies of four states to assess the contributions of state tax incentives to the development of renewable energy markets. State tax incentives that are appropriately paired with complementary state and federal policies generally provide viable mechanisms to support renewable energy deployment. However, challenges to successful implementation of state tax incentives include serving project owners with limited state tax liability, assessing appropriate incentive levels, and differentiating levels of incentives for technologies with different costs. Additionally, state tax incentives may result in moderately higher federal tax burdens. These challenges notwithstanding, state tax incentives that consider certain policy design characteristics can support renewable energy markets and state clean energy goals.The scale of their impact though is directly related to the degree to which they support the renewable energy markets for targeted sectors and technologies. This report highlights important policy design considerations for policymakers using state tax incentives to meet clean energy goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NREL Helps Clean Cities Displace Billions of Gallons of Petroleum, One Vehicle at a Time (Fact Sheet)

With more than 15 years and nearly 3 billion gallons of displaced petroleum under its belt, the Clean Cities program relies on the support and expertise of the National Renewable Energy Laboratory (NREL). An initiative of the U.S. Department of Energy (DOE), Clean Cities creates public-private partnerships with a common mission: to reduce petroleum consumption in the transportation sector. Sincethe inception of Clean Cities in 1993, NREL has played a central role in supporting the program, an effort that stems from the laboratory's strategy to put scientific innovation into action in the marketplace.

02 PETROLEUM↗

Corrosion Behavior of Copper Thin Films in Organic HF-Containing Cleaning Solution for Semiconductor Applications

The corrosion behavior of electrochemically deposited copper thin films in deaerated and non-deaerated commercial cleaning solutions containing HF was investigated. Potentiodynamic polarization experiments were carried out to determine active, active-passive, passive, and transpassive regions. Corrosion rates were calculated from Tafel slopes. The addition of hydrogen peroxide to the solution and its influence on corrosion was also investigated by employing inductively coupled plasma-mass spectroscopy (ICP-MS) and X-ray photoelectron spectroscopy (XPS). The ICP-MS and potentiodynamic methods yielded comparable Cu dissolution rates. Surface analysis using atomic force microscopy and scanning electron microscopy, performed before and after the cleaning solution treatment, did not reveal any indication of pitting corrosion. The presence of hydrogen peroxide in the cleaning solution led to more than an order of magnitude suppression of copper dissolution rate. We ascribe this phenomenon to the formation of interfacial CuO detected by XPS on the wafer surface that dissolves at a slower rate in dilute HF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗