w22_laser_radiography - Laser-Based MeV Radiography

This project seeks to develop novel x-ray sources based on high-power short-pulse lasers with unique advantages, including small spot size, flexible configuration, and tailorable spectra. Kinetic plasma simulations using the VPIC particle in cell code will be performed to support the R&D goals of this project. If successful, this effort will allow LANL to deploy flexible, compact x-ray sources for static tomographic radiography and dynamic multi-axis radiography at our firing sites and facilities such as pRad and U1a. The higher resolution, shorter pulse duration, and tunability of our proposed sources will enable new applications in the weapons program and broader scientific community. This effort advances the LANL FY22 Strategic Investment Plan priority of “[r]adiographic tools for dynamic and static imaging with improved spatial and temporal resolution, sensitivity, and dose.”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenically enhanced quasi-optical resonator for megawatt pulsed millimeter-wave sources

We report the design, cryogenic optimization, and performance modeling of a compact quasi-optical ring resonator intended to compress microwaves pulses at 170 and 250 GHz to the megawatt level. By combining ultra-low-loss CVD diamond and gold-doped silicon wafers with high-RRR copper mirrors, the calculated unloaded quality factor exceeds 4.3 × 10 5 at 20 K and yields simulated gains up to $\mathscr{G}$ = 4.1 × 10 3 . Coupling the resonator with a laser-driven semiconductor switch described by an extended Vogel model shows that 1 MW, nanosecond pulses can be generated from only 445 W of microwave drive power while dissipating 272 W into the cryostat. A practical cooling architecture using two Gifford–McMahon stages (20 and 80 K) is proposed, demonstrating that high-repetition-rate (10–20 kHz) operation is feasible with commercially available cryocoolers. The results outline a clear path toward cost-effective, table-top sources for extreme-ultraviolet lithography, dynamic nuclear polarization, and fusion systems.

Panisset, Constant [Ecole Polytechnique Federale L↗

The Effects of the Local Environment on a Compact Radio Interferometer I: Cross-Coupling in the Tianlai Dish Pathfinder Array

The visibilities measured by radio astronomical interferometers include non-astronomical correlated signals that arise from the local environment of the array. These correlated signals are especially important in compact arrays such as those under development for 21cm intensity mapping. The amplitudes of the contaminated visibilities can exceed the expected 21cm signal and represent a significant systematic effect. We study the receiver noise radiated by antennas in compact arrays and develop a model for how it couples to other antennas. We apply the model to the Tianlai Dish Pathfinder Array (TDPA), a compact array of 16, 6-m dish antennas. The coupling model includes electromagnetic simulations, measurements with a network analyzer, and measurements of the noise of the receivers. We compare the model to drift-scan observations with the array and set requirements on the level of antenna cross-coupling for 21cm intensity mapping instruments. Here, we find that for the TDPA, cross-coupling would have to be reduced by three orders of magnitude in order to contribute negligibly to the visibilities.

21cm intensity mapping↗

First 3D vector tracking of helium recoils for fast neutron measurements at Super$\mathrm{KEKB}$

Here we present results from the first deployment of novel, high definition, compact gas Time Projection Chambers (TPCs) with pixel chip readout as part of the BEAST II beam background measurement project at SuperKEKB. The TPCs provide detailed 3D imaging of ionization from neutron-induced nuclear recoils in a helium and carbon dioxide target gas mixture at standard temperature and pressure. We present the TPC performance and the neutron backgrounds observed during the initial stage of collider commissioning. We find excellent electron background rejection, leading to background-free nuclear recoil measurements above 50 keV ee , despite the extreme high-background environment. We measure an angular resolution better than 20° for recoil tracks longer than 1.7 mm, corresponding to an average ionization energy of approximately 100 keV ee . We also obtain the full 3D vector direction of helium recoils by utilizing charge profile measurements along the recoil axis, with a correct head/tail assignment efficiency of approximately 80%. With this performance, we present comparisons between measured and simulated event rates, recoil energy spectra, and directional distributions originating from beam–gas and Touschek beam losses at SuperKEKB. We utilize head/tail recognition to distinguish neutron components traveling with positive radial velocity in the Belle II coordinate system from those traveling in the opposite direction. Finally, we present a novel method of discriminating beam–gas interactions from Touschek beam losses that can eliminate the need for dedicated accelerator runs for background measurements. This method is still statistics-limited. However, future studies should be able to verify this method, which in turn could lead to neutron background analysis runs symbiotic with normal Belle II operation. The capabilities demonstrated here also suggest that high definition recoil imaging in gas TPCs is applicable to low energy, low-background experiments, such as directional dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EVOLUTION OF PRIMORDIAL STARS POWERED BY DARK MATTER ANNIHILATION UP TO THE MAIN-SEQUENCE STAGE

Primordial stars formed in the early universe are thought to be hosted by compact dark matter (DM) halos. If DM consists of weakly interacting massive particles (WIMPs), such stars may be powered by DM annihilation during the early phases of their evolution. We study the pre-main-sequence evolution of the primordial star using a detailed stellar evolution code under the assumption that the annihilation of adiabatically contracted WIMP DM within the star provides sufficient energy to sustain the stellar equilibrium. We follow the evolution of accreting stars using several gas mass accretion rates derived from cosmological simulations. We show that the stellar mass becomes very large, up to 900-1000 M{sub sun} when the star reaches the main-sequence phase for a reasonable set of model parameters such as DM particle mass and the annihilation cross section. During the dark star phase, the star expands by over a thousand solar radii, while the surface temperature remains below 10{sup 4} K. The energy generated by nuclear reactions is not dominant during this phase. We also study models with different gas mass accretion rates and the DM particle masses. All our models for different DM particle masses pass the dark star phase. The final mass of the dark stars is essentially unchanged for DM mass of m{sub {chi}} {<=} 10 GeV. Gravitational collapse of the massive dark stars will leave massive black holes with mass as large as 1000 M{sub sun} in the early universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Fission Product Inventory and Burnup Evaluation of the AGR-2 Irradiation by Gamma Spectrometry

Gamma spectrometry has been used to evaluate the burnup and fission product inventory of different components from the US Advanced Gas Reactor Fuel Development and Qualification Program's second TRISO-coated particle fuel irradiation test (AGR-2). TRISO fuel in this irradiation included both uranium carbide / uranium oxide (UCO) kernels and uranium oxide (UO 2 ) kernels. Four of the 6 capsules contained fuel from the US Advanced Gas Reactor program, and only those capsules will be discussed in this work. The inventories of gamma-emitting fission products from the fuel compacts, graphite compact holders, graphite spacers and test capsule shell were evaluated. These data were used to measure the fractional release of fission products such as Cs-137, Cs-134, Eu-154, Ce-144, and Ag-110m from the compacts. The fraction of Ag-110m retained in the compacts ranged from 1.8% to full retention. Additionally, the activities of the radioactive cesium isotopes (Cs-134 and Cs-137) have been used to evaluate the burnup of all US TRISO fuel compacts in the irradiation. The experimental burnup evaluations compare favorably with burnups predicted from physics simulations. Predicted burnups for UCO compacts range from 7.26 to 13.15 % fission per initial metal atom (FIMA) and 9.01 to 10.69 % FIMA for UO 2 compacts. Measured burnup ranged from 7.3 to 13.1 % FIMA for UCO compacts and 8.5 to 10.6 % FIMA for UO 2 compacts. Results from gamma emission computed tomography performed on compacts and graphite holders that reveal the distribution of different fission products in a component will also be discussed. Gamma tomography of graphite holders was also used to locate the position of TRISO fuel particles suspected of having silicon carbide layer failures that lead to in-pile cesium release.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Test Plan for the Second Reirradiation Heating Test of Fuel Particles from AGR 2 Compact 6-4-1

Post irradiation examination (PIE) and high-temperature heating tests of tristructural isotropic (TRISO)-coated fuel particles and compacts from the second Advanced Gas Reactor (AGR) irradiation experiment, AGR 2, are in progress. This test plan describes the reirradiation and subsequent high-temperature testing of loose fuel particles obtained from AGR 2 compact 6-4-1. Four of these particles will have been cracked, gamma counted, and re-irradiated in the Neutron Radiography (NRAD) reactor prior to the heating test. The heating test will involve heating the particles in the Fuel Accident Condition Simulator (FACS) furnace to a peak temperature of approximately 1600°C while collecting fission products released from the particles for post-heating test analysis. The intention of the test is to assess the retention of fission products in the fuel kernel. Reirradiation of the particles will allow a determination of the retention of short-lived fission products I-131 (t1/2 = 8.02 days) and Xe-133 (t1/2 = 5.2 days) in the kernel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Constraints on light QCD and CP-violating axions from the death line of rotation-powered pulsars

For axions that couple to nucleons, the presence of dense nuclear matter can displace the axion from its vacuum minimum, sourcing large field gradients around neutron stars (and, more generally, compact objects). These gradients, which we refer to as axion hair, couple to the local background magnetic field, inducing a large voltage drop near the surface of the star; here, we demonstrate that the presence of axion hair decouples local near-field particle acceleration in the open magnetic field line bundle from the rotational frequency of the pulsar itself. This is significant as the non-observation of old slowly-rotating pulsars is attributed to the fact the rotationally-induced electric fields are not strong enough to sustain $e^\pm$ pair production. In this work, we review the evidence for the existence for `pulsar death', i.e. the threshold at which $e^\pm$ pair production (and thus, by association, coherent radio emission) ceases, and demonstrate using both semi-analytics and particle-in-cell simulations that the existence of axion hair can dramatically extend pulsar lifetimes. We show that the non-observation of extremely old, slowly rotating, pulsars allows for a new probe of light QCD and CP-violating axions. We also demonstrate how the observation of emission from both poles of pulsars with nearly orthogonal rotational and magnetic axes, as seen e.g. in PSR J1906+0746, can be used to set competitive limits on CP-violating axion-nucleon interactions.

Witte, Samuel J. [Oxford U., Theor. Phys.; DESY; H↗

Note: Development of a compact x-ray particle image velocimetry for measuring opaque flows. II. Three-dimensional velocity field reconstruction

An x-ray particle image velocimetry (PIV) system using a cone-beam type x-ray was developed. The field of view and the spatial resolution are 36 x 24.05 mm{sup 2} and 20 {mu}m, respectively. The three-dimensional velocity field was reconstructed by adopting the least squares minimum residue and simultaneous multiplicative algebraic reconstruction techniques. According to a simulation study with synthetic images, the reconstructions were acceptable with 7 projections and 50 iterations. The reconstructed and supplied flow rates differed by only about 6.49% in experimental verification. The x-ray tomographic PIV system would be useful for 3D velocity field information of opaque flows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact streak camera for 150 fs time resolved measurement of bright pulses in ultrafast electron diffraction

We have developed a compact streak camera suitable for measuring the duration of highly charged subrelativistic femtosecond electron bunches with an energy bandwidth in the order of 0.1%, as frequently used in ultrafast electron diffraction (UED) experiments for the investigation of ultrafast structural dynamics. The device operates in accumulation mode with 50 fs shot-to-shot timing jitter, and at a 30 keV electron energy, the full width at half maximum temporal resolution is 150 fs. Measured durations of pulses from our UED gun agree well with the predictions from the detailed charged particle trajectory simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of single event transients with dual double-exponential current sources: Implications for logic cell characterization

Single event effects (SEE) are a reliability concern for modern microelectronics. Bit corruptions can be caused by single event upsets (SEUs) in the storage cells or by sampling single event transients (SETs) from a logic path. Likewise, an accurate prediction of soft error susceptibility from SETs requires good models to convert collected charge into compact descriptions of the current injection process. This paper describes a simple, yet effective, method to model the current waveform resulting from a charge collection event for SET circuit simulations. The model uses two double-exponential current sources in parallel, and the results illustrate why a conventional model based on one double-exponential source can be incomplete. Furthermore, a small set of logic cells with varying input conditions, drive strength, and output loading are simulated to extract the parameters for the dual double-exponential current sources. As a result, the parameters are based upon both the node capacitance and the restoring current (i.e., drive strength) of the logic cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-mode state-space dynamic model for Pyrofusion neutron sources - 371

Pyrofusion neutron sources are compact, low power systems which may be capable of producing short intense pulses of neutrons from D-D fusion reactions. The neutron pulse duration has been too short for use as a continuous wave source, and too long for application in interrogation techniques. However, initial analysis of Pyrofusion dynamics has indicated the potential to manipulate the pulse characteristics through system control. This paper introduces the development of state-space multimode system models in MATLAB/Simulink that may be used to support the predictability and control of the neutron pulse. Preliminary examples of frequency-domain studies, stability analysis and time-domain simulations are reported. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Quantum‐Classical Simulation of Quantum Field Theory by Quantum Circuit Learning

Abstract Quantum circuit learning is employed to simulate quantum field theories (QFTs). Typically, when simulating QFTs with quantum computers, significant challenges are encountered due to the technical limitations of quantum devices when implementing the Hamiltonian using Pauli spin matrices. To address this challenge, quantum circuit learning is leveraged, employing a compact configuration of qubits and low‐depth quantum circuits to predict real‐time dynamics in quantum field theories. The key advantage of this approach is that a single‐qubit measurement can accurately forecast various physical parameters, including fully‐connected operators. To demonstrate the effectiveness of this method, it is used to predict quench dynamics, chiral dynamics and jet production in a 1+1‐dimensional model of quantum electrodynamics. It is found that our predictions closely align with the results of rigorous classical calculations, exhibiting a high degree of accuracy. This hybrid quantum‐classical approach illustrates the feasibility of efficiently simulating large‐scale QFTs on cutting‐edge quantum devices.

Ikeda, Kazuki [Department of Physics University of↗

Proton Therapy At Siteman Cancer Center: The State Of The Art

Barnes-Jewish Hospital is on the verge of offering proton radiation therapy to its patients. Those treatments will be delivered from the first Monarch 250, a state-of-the-art cyclotron produced by Still River Systems, Inc., Littleton, MA. The accelerator is the world's first superconducting synchrocyclotron, with a field-strength of 10 tesla, providing the smallest accelerator for high-energy protons currently available. On May 14, 2010 it was announced that the first production unit had successfully extracted 250 MeV protons. That unit is scheduled for delivery to the Siteman Cancer Center, an NCI-designated Comprehensive Cancer Center at Washington University School of Medicine. At a weight of 20 tons and with a diameter of less than 2 meters the compact cyclotron will be mounted on a gantry, another first for proton therapy systems. The single-energy system includes 3 contoured scatterers and 14 different range modulators to provide 24 distinct beam delivery configurations. This allows proton fields up to 25 cm in diameter, with a maximum range from 5.5 to 32 cm and spread-out-Bragg-peak extent up to 20 cm. Monte Carlo simulations have been run using MCNPX to simulate the clinical beam properties. Those calculations have been used to commission a commercial treatment planning system prior to final clinical measurements. MCNPX was also used to calculate the neutron background generated by protons in the scattering system and patient. Additional details of the facility and current status will be presented.

43 PARTICLE ACCELERATORS↗

Large Eddy Simulations for a Helical Coil Steam Generator

The desire for scalable power plants in remote locations and specialized applications has brought forth the small modular reactor (SMR). Now, smaller light water reactors are seen as viable means for meeting global energy requirements. Generally, straight or U-shape tubes are used to exchange heat from the primary to secondary coolant; however this is not ideal when size is a criterion. Helical coil steam generators (HCSGs) are advantageous for SMRs due to their enhanced heat transfer in compact spaces. Still, there is the concern of safety as steam generator tubes could rupture due to vibrations and fatigue on the material. Understanding flow characteristics and quantifying pressures for these tubes are important components for the design of safety and efficiency in these steam generators. The current study uses the spectral element computational fluid dynamic (CFD) code, Nek5000, to develop large eddy simulations (LES) for validation against experiments that will be conducted at Texas A and M University. Time-averaged pressure data will be compared with pressure tap readings, and velocity profile with particle image velocimetry (PIV) measurements. The presented preliminary results investigate the differences between 5.-, 7.-, and 9.-order polynomial simulations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A compact light shield for the Psyche gamma-ray spectrometer

A compact, low-mass light shield has been designed for the Psyche space mission high-purity germanium gamma-ray spectrometer. The spectrometer will be vented to space, which can allow solar photons to enter the cryostat and cause charge-induced noise. The light shield was designed to block more than 99.9% of solar photons while maintaining high molecular conductance to space vacuum. COMSOL simulations and experiments were performed to characterize light shield photon attenuation and molecular conductance. Finally, the light shield was integrated onto the gamma-ray spectrometer and photon suppression and vacuum performance were demonstrated.

(16) Psyche↗

Development of a compact magnetic proton recoil spectrometer for measurement of deuterium-tritium neutrons

A new compact magnetic proton recoil (MPR) neutron spectrometer has been designed for precise measurement of deuterium-tritium (DT) neutrons. This design is presented emphasizing the magnetic analyzing system, which is based on a compact quadrupole-dipole (QD) electromagnet. The focal plane detector (FPD) is also discussed with respect to application for the next step. The characteristics of the MPR spectrometer were calculated by using Monte Carlo simulation. A preliminary experiment was performed to test the magnetic analyzing system and the proton images of the FPD. Since the QD electromagnet design allows for a larger foil thickness and solid angle to be utilized, the MPR spectrometer defined in this paper can achieve neutron detection efficiency more than 5 × 10{sup −7} at an energy resolution of 1.5% for measuring DT neutrons.