Search NASA⌕ Search

SEARCH · Search NASA

Results for “Consumption database”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Analysis of Space-Conditioning Loads in Commercial Buildings

Space conditioning end-uses, which include heating, cooling, and ventilation, represent a significant fraction of commercial building energy use, with a wide variety of heating and cooling technology options available in the market. In the interest of improving the overall efficiency of heating, ventilation and air-conditioning (HVAC) technologies, governments, utilities and private sector entities have implemented a variety of market transformation policies that aim to influence consumer purchase decisions. To evaluate the costs and benefits of such programs, analysts typically postulate a hypothetical default equipment choice, and compare it to one that provides comparable service with lower energy and/or power use. The corresponding reduced operating cost provides a benefit that offsets the potential higher cost of improved efficiency. Typically, life-cycle cost or cash-flow analyses are used to quantify the net economic benefit. These analyses require the capability to assess how a given equipment design would perform across a broad range of characteristics, both of the building and of the local weather. While these assessments can be performed using customized building simulations, it is generally not practical to develop and validate detailed building simulation code to cover all the potential variations of equipment design and installation. An alternative, and somewhat simpler, approach is to solely use detailed building simulations to generate time series of heating and cooling loads in commercial buildings. These loads can then be used as input to more detailed, stand-alone engineering models that simulate HVAC system performance under different equipment designs. This approach was used to evaluate a range of high-efficiency commercial packaged air conditioner design options for the Department of Energy’s Appliance and Equipment Standards Program (DOE-EERE 2015). While there may be some loss of precision relative to full simulation, the accuracy of this approach is sufficient for practical applications of cost-benefit analysis. This report describes the development of a database of commercial building heating and cooling loads, generated using the EnergyPlus software package, a whole building energy use model supported by the Department of Energy (DOE-EERE 2020a). EnergyPlus takes as input a set of configuration files that describe the building itself (size, zoning, envelope characteristics, etc.) and the various systems within it (HVAC, lighting, water heating, etc.). This analysis uses a publicly available collection of commercial reference buildings (CRB), comprised of sixteen building types and three vintages (DOE-EERE 2020b; Deru et al 2011). Each building is simulated in eighteen different locations, covering a wide range of climatic conditions. The prototype building description files assign the type of HVAC equipment used, and capacities across climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling the Interaction Between Energy Efficiency and Demand Response on Regional Grid Scales: Preprint

With increasing penetration of intermittent renewable generation at grid and distributed scales, flexible building loads can provide significant system value and support the evolving needs of the grid. The growing value of load flexibility may complicate the traditional separation between energy efficiency (EE) and demand response (DR). EE measures may compete in some cases with a building’s DR capabilities but complement one another in other cases. EE can also increase or decrease the need for DR at the system level and change the availability of DR to meet system needs. In this study we present a bottom-up approach to modeling interactive effects between EE and DR in buildings within two regions of the US electricity grid. From a library of building simulation models for different buildings and climates, we synthesize system-level demand profiles and the impacts of potential future EE portfolios. Coupling the underlying building models with a database of DR-enabling technologies, we then compute the quantity of DR that can be delivered in each scenario. The results show that EE and DR interactions are largely driven by the timing of EE savings that are measure-specific and the coincidence with system peak demand that is region-specific. We also find that perspective of the impacts matters – for instance that some EE measures reduce the system need for DR but also reduce the DR potential. Our results imply that utility EE and DR programs developed without considering interactive effects may lead to increased grid-management challenges over the long term.

buildings↗

Generating realistic building electrical load profiles through the Generative Adversarial Network (GAN)

Building electrical load profiles can improve understanding of building energy efficiency, demand flexibility, and building-grid interactions. Current approaches to generating load profiles are time-consuming and not capable of reflecting the dynamic and stochastic behaviors of real buildings; some approaches also trigger data privacy concerns. In this study, we proposed a novel approach for generating realistic electrical load profiles of buildings through the Generative Adversarial Network (GAN), a machine learning technique that is capable of revealing an unknown probability distribution purely from data. The proposed approach has three main steps: (1) normalizing the daily 24-hour load profiles, (2) clustering the daily load profiles with the k-means algorithm, and (3) using GAN to generate daily load profiles for each cluster. The approach was tested with an open-source database – the Building Data Genome Project. We validated the proposed method by comparing the mean, standard deviation, and distribution of key parameters of the generated load profiles with those of the real ones. The KL divergence of the generated and real load profiles are within 0.3 for majority of parameters and clusters. Additionally, results showed the load profiles generated by GAN can capture not only the general trend but also the random variations of the actual electrical loads in buildings. We report the proposed GAN approach can be used to generate building electrical load profiles, verify other load profile generation models, detect changes to load profiles, and more importantly, anonymize smart meter data for sharing, to support research and applications of grid-interactive efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture Transfer in Commercial Buildings Due to Air Leakage: A New Feature in the Online Airtightness Savings Calculator

Air leakage through the building envelopes is responsible for a large amount of energy use. The US Department of Energy Windows and Building Envelope Research and Development Roadmap for Emerging Technologies states that, in 2010, air infiltration was responsible for 20% of primary energy consumption attributable to the fenestration and building envelopes of commercial buildings. Despite this fact, improving airtightness is not always recognized by commercial building owners, as they have been slow in acknowledging and diminishing the detrimental effects of air leakage on energy use, comfort, indoor air quality, and building material durability.The design and construction industry would benefit from a credible, easy-to-use tool that estimates potential energy and financial savings in a standardized manner so designers and contractors can give building owners compelling reasons to invest in reducing air leakage. In 2016–2017, Oak Ridge National Laboratory, the National Institute of Standards and Technology, the Air Barrier Association of America, and the US-China Clean Energy Research Center for Building Energy Efficiency collaborated to develop an online calculator. This user-friendly calculator is free to the public and uses the simulation results of the whole building energy simulation tool EnergyPlus and the airflow simulation tool CONTAM. In 2018–2019, the calculator was expanded to add moisture transfer calculations given that air leakage through the building envelope can have a significant impact on moisture transfer and associated impacts. Four more commercial building types were also added to the existing database of three building types as part of this update. This paper describes the procedure used to calculate moisture transfer due to air leakage and provides examples that demonstrate the moisture transfer for each of the seven commercial building types that are currently part of the calculator.

Shrestha, Som↗

Refining seasonal performance metrics for room air-conditioning in emerging markets: Integrating building simulations with real-world equipment performance data

Buildings significantly impact worldwide energy consumption, emphasizing the need to reduce the cooling energy demand, especially in warm climates. Minimum energy performance standards (MEPS) and seasonal performance metrics such as the Cooling Seasonal Performance Factor (CSPF) are crucial for improving room air conditioning (RAC) efficiency. However, challenges remain, particularly in emerging markets like Brazil, where seasonal performance metrics have recently been introduced. This study assesses the factors influencing country-level seasonal efficiency metrics and proposes a framework to refine these calculations by considering local climates and expected RAC usage in real-world households via building simulations. Key considerations include outdoor air temperature binning for different climates, RAC usage patterns (i.e., daytime and nighttime usages), envelope thermal performance of households, and urban heat island (UHI) effects. The results reveal that CSPF values can vary significantly based on climate conditions, with observed CSPF ranging from 4.10 to 11.59 Wh/Wh across 577 Brazilian climates. The inclusion of UHI effects led to a reduction in CSPF values by up to 29% during nighttime operations in hot urban areas. Additionally, building envelope efficiency showed contrasting impacts on RAC performance, with CSPFs reaching up to 15.35 Wh/Wh under specific optimized conditions. These findings highlight the need for transparent policymaking in RAC performance databases, facilitating the application of approaches like those proposed in this study and supporting diverse stakeholders in decision-making.

Bavaresco, Mateus↗

NLR HPC Eagle Jobs Data and Additional Energy Metrics

Overview: Anonymized job-level records from the Eagle high-performance computing (HPC) system at the National Laboratory of the Rockies (NLR). Each record represents a Slurm batch job with scheduling metadata, resource requests, resource utilization, CPU/GPU energy consumption, and efficiency metrics. Sensitive fields (user, account, job name) are replaced with cryptographic hashes. System & Timeframe: Eagle was a 2,000-node, 8-petaflop system operated at NLR from 2019–2024. Data covers the full operational lifetime of the system. Slurm data was processed nightly; timestamps are in Mountain Time. Funding provided by the U.S. Department of Energy, EERE. Files: esif.hpc.eagle.job-anon.zip — Core anonymized job records (Hive-partitioned Parquet) esif.hpc.eagle.job-anon-energy-metrics.zip — Same records with additional iLO and Ganglia energy metrics datacard.md — Full dataset documentation ~13.8 million rows, 62 variables. Readable with PyArrow, pandas, DuckDB, Apache Spark, or any Parquet-compatible tool. Data Collection: Jobs collected via sacct through a pipeline: Eagle Jobs API → Redpanda → StreamSets → HPCMON API → PostgreSQL. Node-level power from iLO (HP Integrated Lights-Out); GPU power from Ganglia monitoring, joined to jobs via node lists and time ranges. Preprocessing: Anonymization of name, user, and account fields via cryptographic hashing Derived columns: queue_wait, cpu_eff, max_mem_eff Simplified job state mapping (e.g., "CANCELLED BY 12345" → "CANCELLED") QoS accounting rules (buy-in, standby, or Slurm QoS value) CPU energy estimated from TDP (200W, Intel Xeon Gold 6154, 18 cores) Timezone-aware columns (_tz) sourced from LEX accounting database to correctly handle DST transitions Key Variables: Scheduling: job_id, partition, state_simple, submit_time_tz, start_time_tz, end_time_tz, queue_waitResources: nodes_req/used, processors_req/used, memory_req, wallclock_req/used, gpus_requested Efficiency: cpu_eff, max_mem_eff Energy: cpu_energy_tdp_estimated_max/used_watt_hours, node_energy_total_watt_hours (iLO), gpu0/1_energy_total_watt_hours (Ganglia) Partitions: bigmem, bigmem-8600, bigscratch, csc, dav, ddn, debug, gpu, haswell, long, mono, short, standard Job States: CANCELLED, COMPLETED, FAILED, NODE_FAIL, OUT_OF_MEMORY, PENDING, RUNNING, TIMEOUT QoS Levels: Unknown, normal, buy-in, debug, penalty, high, standby Important Notes: Non-_tz timestamp columns may be off by one hour across DST boundaries; use _tz columns for time difference calculations Energy fields are null for jobs without monitoring coverage Job step records and raw Slurm JSONB fields are excluded from this extract Do not attempt to re-identify individuals from hashed fields

97 MATHEMATICS AND COMPUTING↗

Enabling Detailed Energy Analyses via the Technology Performance Exchange: Preprint

One of the key tenets to increasing adoption of energy efficiency solutions in the built environment is improving confidence in energy performance. Current industry practices make extensive use of predictive modeling, often via the use of sophisticated hourly or sub-hourly energy simulation programs, to account for site-specific parameters (e.g., climate zone, hours of operation, and space type) and arrive at a performance estimate. While such methods are highly precise, they invariably provide less than ideal accuracy due to a lack of high-quality, foundational energy performance input data. The Technology Performance Exchange was constructed to allow the transparent sharing of foundational, product-specific energy performance data, and leverages significant, external engineering efforts and a modular architecture to efficiently identify and codify the minimum information necessary to accurately predict product energy performance. This strongly-typed database resource represents a novel solution to a difficult and established problem. One of the most exciting benefits is the way in which the Technology Performance Exchange's application programming interface has been leveraged to integrate contributed foundational data into the Building Component Library. Via a series of scripts, data is automatically translated and parsed into the Building Component Library in a format that is immediately usable to the energy modeling community. This paper (1) presents a high-level overview of the project drivers and the structure of the Technology Performance Exchange; (2) offers a detailed examination of how technologies are incorporated and translated into powerful energy modeling code snippets; and (3) examines several benefits of this robust workflow.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Soiling of building envelope surfaces and its effect on solar reflectance. Part I: Analysis of roofing product databases

The use of highly reflective “cool” roofing materials can decrease demand for air conditioning, mitigate the urban heat island effect, and potentially slow global warming. However, initially high roof solar reflectance can be degraded by natural soiling and weathering processes. We evaluated solar reflectance losses after three years of natural exposure reported in two separate databases: the Rated Products Directory of the US Cool Roof Rating Council (CRRC) and information reported by manufacturers to the US Environmental Protection Agency (EPA)’s ENERGY STAR® rating program. Many product ratings were culled because they were duplicative (within a database) or not measured. A second, site-resolved version of the CRRC dataset was created by transcribing from paper records the site-specific measurements of aged solar reflectance in Florida, Arizona and Ohio. Products with high initial solar reflectance tended to lose reflectance, while those with very low initial solar reflectance tended to become more reflective as they aged. Within the site-resolved CRRC database, absolute solar reflectance losses for samples of medium-to-high initial solar reflectance were 2 - 3 times greater in Florida (hot and humid) than in Arizona (hot and dry); losses in Ohio (temperate but polluted) were intermediate. Disaggregating results by product type, factory-applied coating, field-applied coating, metal, modified bitumen, shingle, singleply membrane and tile, revealed that absolute solar reflectance losses were largest for fieldapplied coating, modified bitumen and single-ply membrane products, and smallest for factoryapplied coating and metal products.The 2008 Title 24 provisional aged solar reflectance formula overpredicts the measured aged solar reflectance of 0% to 30% of each product type in the culled public CRRC database. The rate of overprediction was greatest for field-applied coating and single-ply membrane products and least for factory-applied coating, shingle, and metal products. New product-specific formulas can be used to estimate provisional aged solar reflectance from initial solar reflectance pending measurement of aged solar reflectance. The appropriate value of soiling resistance varies by product type and is selected to attain some desired overprediction rate for the formula. The correlations for shingle products presented in this paper should not be used to predict aged solar reflectance or estimate provisional aged solar reflectance because the data set is too small and too limited in range of initial solar reflectance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Consumer Benefits of Clean Energy: Energy Efficiency

Meeting national and state decarbonization goals requires a transition to clean energy technologies. Energy efficiency, demand flexibility, renewable energy and storage can reduce consumers’ electricity bills, lower total electricity system costs, and provide health and resilience benefits. Berkeley Lab developed a series of briefs that explore these consumer benefits of a clean energy transition. This brief focuses on energy efficiency benefits, and builds on prior analysis from Berkeley Lab’s Cost of Saved Energy database. We show that energy efficiency remains a low-cost energy and capacity resource; the levelized cost of saving energy for the programs included in the analysis is $\$0.02$/kilowatt-hour and the cost of saving peak demand is less $\$120$/kilowatt. Understanding the impact of the program mix, portfolio size, and duration of implementation for customer-funded energy efficiency portfolios can guide regulatory oversight of these programs, help utilities better utilize energy efficiency as a resource, and inform building energy decarbonization policies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

Cs-137 Body-burdens in Wild Pigs on the Department of Energy's Savannah River Site: Determination of an Appropriate Framework for Spatiotemporal Analysis of Hunter Dose Tracking System Data

The Savannah River Site (SRS) is a U.S. Department of Energy facility with an area of 310 square miles. Since its opening in 1951, SRS has produced and processed nuclear materials for national defense and industrial purposes. These activities have resulted in the release of radiocesium (Cs-137) which has led to contamination of associated streams, floodplains, man-made reservoirs, soil and vegetation. Contamination is spread to wild pigs as they move about SRS, consume vegetation, drink water and wallow in soil. SRS provides annual deer hunts open to the public in which wild pigs may be taken as well. The Cs-137 concentration of each animal is determined before it is released to the hunter for consumption and a cumulative dose is retained for each individual hunter. These tasks are accomplished using the Hunter Dose Tracking System (HDTS). The data collected on SRS by the HDTS for White-Tailed deer has been extensively analyzed. A repeatable method for calculating the background radiocesium body burden for the SRS deer population was established by Gaines and Novak (2009,2016). This model was framed using Cs-137 contamination obtained via gamma over-flight data, the decay rate of radiocesium and the historical behavior observed in the SRS deer population. These parameters were used in a spatiotemporal analysis to estimate background Cs-137 body burdens (from global fallout, etc.), as well as the effect SRS activities may have. The purpose of this project is to modify the framework to represent the behavior of the wild pig population on SRS such that HDTS data collected may be analyzed similarly. The 2018 data were collected via the HDTS in the field to screen wild pigs dispatched by Forest Service - Savannah River. These data will provide insight for an analysis of seasonal variance in the body burdens of the SRS wild pig population. The HDTS quickly provided Cs-137 concentrations in the field, as well as automatically updated the electronic database. Space: Historically, the average home range of wild pigs on the Savannah River Site has been reported at approximately six square miles. This range was confirmed accurate as of July 2018, with the observed minimum and maximum at one and ten square miles respectively. This range was geoprocessed using ArcMap to project buffers based on 1991 gamma over-flight data. The buffers were constructed to originate at all Cs-137 contamination point coordinates and protrude outward in all directions for 1.5, 2.45 and 6 square miles. While the 2.45 mile buffer is theoretically representative of potential hog exposure based on the average home range, it does not consider the possibility of home ranges not uniform in shape. Therefore, the 1.5 and 6 mile buffers were also constructed as visual aids for determining the appropriate hunt compartments for background level considerations. The SRS is divided into numbered hunt compartments of varying size and shape. These compartment numbers are used during sponsored hunts to record the location in which a wild pig was dispatched. Time: The Gaines report determined deer analysis should be carried out at the half-decade level for the best representation of true body burdens. This is due to the impact natural factors, such as drought or flood, can have on the bioaccumulation of Cs-137. To determine the appropriate time scale for hog analysis, all available data was totaled and averaged at 1, 2, 3 and 7 year increments. The annual averages and running average are provided. The appropriate compartments for the determination of the SRS hog population background level should be: 2, 3, 4, 9, 10, 14 and 15. Hogs dispatched within other compartments are most likely exposed to Cs-137 contamination and should not be included in the background level. The current dataset is small, but was still able to demonstrate the relationship between where hogs on SRS and the Cs-137 body burdens they incur. Geoprocessing the data using the average home range of wild pigs highlighted the importance of collecting additional samples from areas surrounding SRS if an accurate background is to be determined. When the average concentration of Cs-137 in pigs from background compartments is compared against that of pigs from contaminated compartments, a significant difference can be seen. A Table provides a summary of the analyzed data from the 15 years processed thus far.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2024 Buildings Technology Baseline: Dataset Documentation

The Buildings Technology Baseline is a curated and regularly updated dataset of current and projected performance, retail, and installed price data for all major building energy technologies needed to enable cost/benefit analyses. Building technology analyses require an up-to-date understanding of installation costs and cost-effectiveness of key building energy efficiency technologies. The dataset was assembled by Guidehouse during fiscal year 2024. Data was gathered from the 2024 National Residential Efficiency Measures Database (NREMDB), the 2023 Energy Information Administration Updated Buildings Sector Appliance and Equipment Costs and Efficiencies ("EIA Building Data Report"), DOE Lighting Market Model, the 2023 RSMeans database, and the 2020 Grid-Interactive Efficient Building Technology Cost, Performance, and Lifetime Characteristics ("GEB Data Report"), Lawrence Berkeley National Laboratory, various literature, as well as new data from online retailers, stakeholder interviews, and contractor databases in 2023 and 2024. The dataset has been reviewed by subject matter experts at NREL and DOE. The 2024 dataset release is intended to be a starting point for interested users to provide feedback. This database is not intended to provide specific cost estimates for a specific project. The cost estimates do not include any rebates or tax incentives that may be available for the measures. Rather, it is meant to help determine which measures may be more cost-effective. The National Renewable Energy Laboratory (NREL) makes every effort to ensure accuracy of the data; however, NREL does not assume any legal liability or responsibility for the accuracy or completeness of the information.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Adaptive behavior and different thermal experiences of real people: A Bayesian neural network approach to thermal preference prediction and classification

Various observed and unquantifiable factors affect the thermal comfort of occupants in indoor environments and can lead to high uncertainty in the prediction and classification of their thermal preferences. The behavioral adaptation of occupants, by operating window systems for example, changes their thermal experience and expectations and therefore contributes to even higher prediction uncertainty. In this study, we applied a Bayesian neural network (BNN) algorithm to build a predictive model for occupant thermal preference using the ASHRAE Global Thermal Comfort Database II. The Bayesian method allows us to synthesize prior knowledge and available measurements into a unified modeling framework. It also offers a way to express and quantify uncertainty. Here we have performed a systematic study to test the efficiency and robustness of different BNN model configurations. In this study, the results show that the BNN model outperforms conventional thermal comfort models such as Predicted Mean Vote (PMV) and adaptive comfort model. The BNN model tends to produce more confident “prefer cooler” predictions with high possibility and low uncertainty. In contrast, the BNN model produces less certain predictions for “prefer no change” and “prefer warmer” across all occupants. Our findings suggest that linking occupants’ subjective evaluation measures and window opening/closing behavior to thermal comfort modeling effectively improves predictive performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EVSE Characterization

NextGen Profiles' EVSE characterization efforts explored performance variability in production EVSE through the use of EV emulation equipment and assessed how different operational conditions influence charging behavior. Data were collected at a frequency of 10 Hz from both the EV emulator and EVSE during each charge session and stored in a time-series database for further analysis. As part of the NextGen Profiles project, characterization of high-power EVSE was performed on both conductive and wireless charging infrastructure; however, only conductive charging data are currently included in this repository. This EVSE characterization was performed over a range of DC output currents and voltages, covering both nominal and off-nominal test conditions. This EVSE characterization dataset includes high-power charging data from two types of 350-kW-capable EVSE using liquid-cooled Combined Charging System-1 (CCS1, North American version) cables and connectors. To protect confidentiality, all EVSE metadata are anonymized, and the publicly released datasets are metered at 10-Hz frequency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Storage Cost and Performance Database

In support of the U.S. Department of Energy’s Energy Storage Grand Challenge, Pacific Northwest National Laboratory is applying its rich history of battery research and development to provide the U.S. Department of Energy (DOE) and industry with a guide to current energy storage costs and performance metrics for various technologies. Cost and performance metrics for individual technologies track the following to provide an overall cost of ownership for each technology: cost to procure, install, and connect an energy storage system; associated operational and maintenance costs; and end-of-life costs. These metrics are intended to support DOE and industry stakeholders in making sound decisions about future R&D directions and priorities that move the United States closer to its goal of energy independence. The technologies currently being evaluated are lithium-ion [lithium iron phosphate (LFP) and nickel manganese cobalt (NMC)] batteries, vanadium redox flow batteries, lead-acid batteries, zinc-based batteries, hydrogen energy storage, pumped storage hydropower, gravitational energy storage, compressed air energy storage, and thermal energy storage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robustness of topological persistence in knowledge distillation for wearable sensor data

Topological data analysis (TDA) has shown great success in various applications involving wearable sensor data. However, there are difficulties in leveraging topological features in machine learning and wearable sensors because of the large time consumption and computational resources required to extract the features. To address this problem, knowledge distillation (KD) is utilized to generate a small model and accommodate topological features with persistence image (PI) representations from the raw time series data. Deploying topological knowledge in KD enables the student to achieve better performance compared to the one trained solely on raw time series data. However, it is not yet known if there are coherent characteristics for topological features in PI, which can aid in improving the performance during KD. In this paper, we investigate the suitability and challenges of utilizing topological features in KD for wearable sensor data, thereby contributing to the advancement of the field. Our study explores the impact of transferred topological features by comparing the Teacher-to-Student framework with Multiple Teachers-to-Student where teachers utilize both time series data and persistence images obtained by TDA as inputs. Additionally, we conduct a rigorous examination of topological knowledge effects by testing under various corruptions, knowledge types, and learning strategies in the context of human activity recognition tasks. Our analysis of topological features in KD presents the optimal strategy for incorporating these features. This study includes datasets of varying scales, window lengths, and activity classes, providing a comprehensive evaluation. Our results demonstrate that leveraging topological features in KD to enhance performance across databases.

97 MATHEMATICS AND COMPUTING↗

Technical analysis of filter testing at the U.S. Department of Energy Filter Test Facility

The U.S. Department of Energy (DOE) technical standard DOE-STD-3020-2015 requires verification testing at the Filter Test Facility (FTF) of high-efficiency particulate air (HEPA) filters to be installed in nuclear facility (Hazard Category 1, 2, 3, and radiological facilities) confinement ventilation systems, or to be installed in habitability systems (e.g., filters for protection of workers required to act for the control and mitigation of emergency situations). Filters in these applications perform a safety function in accident situations, are designated as important to safety, or are necessary for habitability systems. Different FTFs have operated for decades, and results of tests are available to examine the need for and benefits of continued execution of 100 percent QA verification testing. The objective of this study and resulting report was to assess the need for 100 percent QA testing at the current FTF in Maryland, based on an examination of a database of test results from 2013 to August 2020. Filters that require independent testing per DOE-STD-3020-2015 to be installed in nuclear facilities are sent to the FTF before being shipped to the facilities. The FTF examines the documentation (e.g., certificates of compliance, results of particle penetration and airflow resistance testing by the manufacturers, labels affixed to filters and packages, and other requirements specified in purchase orders by the nuclear facility operators), implements visual inspections of the physical state of the filters, and checks the dimensions of frames. Filters that meet the documentation and visual inspection requirements are subjected to particle penetration and airflow resistance testing. In case of rejections, the filters are shipped back to the manufacturers, at the cost of the manufacturers, for replacement. Filters that pass all tests are shipped to the nuclear facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of electric vehicle interconnection with commercial building microgrids

The outline of this presentation is: (1) global concept of microgrid and electric vehicle (EV) modeling; (2) Lawrence Berkeley National Laboratory's Distributed Energy Resources Customer Adoption Model (DER-CAM); (3) presentation summary - how does the number of EVs connected to the building change with different optimization goals (cost versus CO{sub 2}); (3) ongoing EV modeling for California: the California commercial end-use survey (CEUS) database, objective: 138 different typical building - EV connections and benefits; (4) detailed analysis for healthcare facility: optimal EV connection at a healthcare facility in southern California; and (5) conclusions. Conclusions are: (1) EV Charging/discharging pattern mainly depends on the objective of the building (cost versus CO{sub 2}); (2) performed optimization runs show that stationary batteries are more attractive than mobile storage when putting more focus on CO{sub 2} emissions. Why? Stationary storage is available 24 hours a day for energy management - more effective; (3) stationary storage will be charged by PV, mobile only marginally; (4) results will depend on the considered region and tariff - final work will show the results for 138 different buildings in nine different climate zones and three major utility service territories.

25 ENERGY STORAGE↗