Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryogenic cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Stray radiation and the Infrared Astronomical Satellite /IRAS/ telescope

Stray light control is a major consideration in the design of infrared cryogenically cooled telescopes such as the Infrared Astronomical Satellite (IRAS). The basic design of the baffle system, and the placement, shape, and coating of the secondary support struts for the telescope subsystem are described. The intent of this paper is to highlight the stray light problems encountered while designing the system, and to illustrate how computer analysis can be a useful design aid. Scattering measurements of the primary mirror, and a full system level scatter measurement are presented. Comparisons of predicted performance with the measured results are also presented.

Noll, R. J.↗

Orbital operations with the Shuttle Infrared Telescope Facility /SIRTF/

The Shuttle Infrared Telescope Facility (SIRTF) is a cryogenically-cooled, 1-m-class telescope that will be operated from the Space Shuttle as an observatory for infrared astronomy. This paper discusses the scientific constraints on and the requirements for pointing and controlling SIRTF as well as several aspects of SIRTF orbital operations. The basic pointing requirement is for an rms stability of 0.25 arcsec, which is necessary to realize the full angular resolution of the 5-micron diffraction-limited SIRTF. Achieving this stability requires the use of hardware and software integral to SIRTF working interactively with the gyrostabilized Shuttle pointing-mount. The higher sensitivity of SIRTF, together with orbital and time constraints, puts a premium on rapid target acquisition and on efficient operational and observational procedures. Several possible acquisition modes are discussed, and the importance of source acquisition by maximizing the output of an infrared detector is emphasized.

Werner, M. W.↗

Shuttle infrared telescope facility pointing and control system

The Shuttle Infrared Telescope Facility (SIRTF) is being designed as a 0.85 m cryogenically cooled telescope capable of a three order of magnitude improvement over currently available infrared instruments. The SIRTF requires that the image at the focal plane be stabilized to better than 0.25 arcsec with an absolute accuracy of 1.0 arcsec. Current pointing-mount performance simulations indicate that neither of these requirements can be met without additional stabilization. The SIRTF pointing and control system will utilize gyro outputs, star field position measurements from a focal plane fine guidance sensor, and a steerable secondary mirror to provide the necessary stabilization and pointing control. The charge coupled device fine guidance sensor tracks multiple stars simultaneously and, through the use of multistar processing algorithms in a high performance microcomputer, generates three-axis attitude errors and gyro-drift estimates to correct the pointing-mount gyros. A high-bandwidth feedforward loop, driven directly from the pointing-mount gyro package, controls the steering mirror in order to correct disturbances not compensated for by the pointing-mount control system. A prototype design for the SIRTF pointing and control system is described in detail. Performance analyses made using a digital simulation of the pointing and control system as well as experimental data obtained in laboratory and field test measurements are presented.

Lorell, K. R.↗

The sixteen to forty micron spectroscopy from the NASA Lear jet

Two cryogenically cooled infrared grating spectrometers were designed, fabricated and used on the NASA Lear Jet Observatory. The first spectrometer was used to measure continuum sources such as dust in H II regions, the galactic center and the thermal emission from Mars, Jupiter, Saturn, and Venus over the 16 to 40 micron spectral range. The second spectrometer had higher resolution and was used to measure ionic spectral lines in H II regions (S III at 18.7 microns). It was later used extensively on NASA C-141 Observatory to make observations of numerous objects including H II regions, planetary nebulae, stars with circumstellar shells, the galactic center and extragalactic objects. The spectrometers are described including the major innovations and a list of the scientific contributions.

Houck, J. R.↗

Sunshade/radiative cooler for IRAS infrared astronomical satellite

The Infrared Astronomical Satellite (IRAS) is a joint project shared by the United States and the Netherlands with the United Kingdom providing tracking and ground support services. IRAS features a cryogenically cooled telescope designed to perform an unbiased all-sky survey of the far infrared spectrum from 8 to 120 microns and to observe objects of special interest. The sunshade is designed to protect the telescope aperture and sunshade radiators from: direct solar radiation; direct earth radiation; radiation exchange with satellite structures; excessive aperture heating caused by sunshade inner cone emission. The sunshade three-stage radiative cooler design meets the listed requirements and, in addition, provides some contamination protection for the telescope aperture and optical surfaces during pointing maneuvers when the telescope is tilted in the direction of the velocity vector. Unless protected by the sunshade, the ram effect can cause molecules to enter the aperture and deposit on the cooled optical surfaces. This paper describes the sunshade design, the thermal analyses, and the results of thermal balance testing of the flight hardware.

Anderson, R. R.↗

Closed-cycle cryogenic pump suitable for sounding rockets use

We have successfully used a closed-cycle cryogenic cooling system as a high-speed UHV pump for instruments carried into the upper atmosphere on board sounding rockets. The device utilizes a commercially available, Sterling-cycle refrigerator that has proven to be rugged and simple to use under field conditions.

Erdman, P. W.↗

Fourier spectroscopy on planetary missions including Voyager

For more than a decade, spaceborne Fourier transform spectrometers have been employed in investigations concerning the earth and other objects in the solar system. The wide spectral range at moderately high spectral resolution, the precise wavenumber and radiometric calibrations, and the reliability achieved by these instruments, have permitted scientific investigations which would otherwise have been impossible. Weight limitations and the long flight durations prohibited the use of highly sensitive, cryogenically cooled detectors on these missions. A brief review is presented of the evolution of the instruments known as IRIS (InfraRed Interferometric Spectrometer). The concept of remote sensing by infrared emission spectroscopy is discussed, and examples of results obtained with IRIS are presented. Attention is given to the most recent results from Voyager with emphasis on those from Titan.

Hanel, R. A.↗

The development and applications of charge-coupled devices for space astronomy

The developments in charge-coupled device technology over the past decade are reviewed, with emphasis on the relevance of these developments to astronomical applications. The characteristics and limitations of current commercial devices are described, and the future requirements on CCDs for space astronomy are summarized for the X-ray and near UV, optical, and infrared wavelength ranges. Emphasis is placed on the commonality of technological development which is called for, including the issues of quantum detection efficiency (photon entrance and depletion depth), charge transfer efficiency, modulation transfer function, output noise level, and array size. The system requirements on focal plane instrumentation for space astronomy are summarized, and shown to have much in common for the different wavelength bands. These requirements are discussed in terms of CCD mosaicing, cryogenic cooling, and electronics. The overlap in CCD developments in the defense, astronomical and commercial arenas is summarized.

Griffiths, R. E.↗

Si:Bi switched photoconducttor infrared detector array

A multiplexed infrared detector array is described. The small demonstration prototype consisted of two cryogenically cooled, bismuth doped silicon, extrinsic photoconductor pixels multiplexed onto a single output channel using an on focal plane switch integration sampling technique. Noise levels of the order of 400 to 600 rms electrons per sample were demonstrated for this chip and wire hybrid version.

Eakin, C. E.↗

The state-of-the-art of cryogenic thermometry and signal conditioners and their potential for standardized space hardware

The possibility of standard low temperature detector(s) for use in upcoming cryogenically cooled satellite and Space Shuttle payloads were investigated. These payloads operate from .3 kelvin to 300 kelvin. Standard detectors were selected and matching signal conditioning equipment compatible with the selected detector, typical spacecraft voltages, typical spacecraft telemetry systems, and the radiation encountered by a typical Earth orbiting spacecraft. Work statements to better define and advance detector performance were presented.

Source record↗

Stirling cycle cryogenic cooler

A long lifetime Stirling cycle cryogenic cooler particularly adapted for space applications is described. It consists of a compressor section centrally aligned end to end with an expansion section, and respectively includes a reciprocating compressor piston and displacer radially suspended in interconnecting cylindrical housings by active magnetic bearings and has adjacent reduced clearance regions so as to be in noncontacting relationship therewith and wherein one or more of these regions operate as clearance seals. The piston and displacer are reciprocated in their housings by linear drive motors to vary the volume of respectively adjacent compression and expansion spaces which contain a gaseous working fluid and a thermal regenerator to effect Stirling cycle cryogenic cooling.

Gasser, M. G.↗

Vibration isolation and pressure compensation apparatus for sensitive instrumentation

A system for attenuating the inherent vibration associated with a mechanical refrigeration unit employed to cryogenically cool sensitive instruments used in measuring chemical constituents of the atmosphere is described. A modular system including an instrument housing and a reaction bracket with a refrigerator unit floated there between comprise the instrumentation system. A pair of evacuated bellows that "float' refrigerator unit and provide pressure compensation at all levels of pressure from seal level to the vacuum of space. Vibration isolators and when needed provide additional vibration damping for the refrigerator unit. A flexible thermal strap (20 K) serves to provide essentially vibration free thermal contact between cold tip of the refrigerator unit and the instrument component mounted on the IDL mount. Another flexible strap (77 K) serves to provide vibration free thermal contact between the TDL mount thermal shroud and a thermal shroud disposed about the thermal shaft.

Averill, R. D.↗

X-ray spectroscopy and imagery of supernova remnants with the Einstein Observatory

The two complementary spectroscopic instruments of the Einsten Observatory make possible X-ray spectroscopy of SNRs with considerably increased sensitivity and spectral resolution. The Solid State Spectrometer is a cryogenically cooled detector with 160 eV resolution, which suffices not only for the separation of lines due to different elements, but also the resolution of H-like, He-like and neutral lines from the same element for Si and above. The Focal Plane Crystal Spectrometer uses Bragg crystals to achieve excellent spectral resolution, but at the expense of sensitivity. Both instruments operate over most of the 0.2-4 keV energy band of the Einstein telescope, and are able to detect most of the important X-ray lines except the K lines of Fe and Ni.

Winkler, P. F.↗

A microprocessor-based position control system for a telescope secondary mirror

The pointing requirements for the Shuttle IR Telescope Facility (SIRTF), which consists of an 0.85-m cryogenically cooled IR telescope, call for an image stability of 0.25 arcsec. Attention is presently given to a microprocessor-based position control system developed for the control of the SIRTF secondary mirror, employing a special control law (to minimize energy dissipation), a precision capacitive position sensor, and a specially designed power amplifier/actuator combination. The microprocessor generates the command angular position and rate waveforms in order to maintain a 90 percent dwell time/10 percent transition time ratio independently of chop frequency or amplitude. Performance and test results of a prototype system designed for use with a demonstration model of the SIRTF focal plane fine guidance sensor are presented.

Lorell, K. R.↗

A Sensitive Infrared Photodetector

Technique utilizing photodetachment of negative ions incorporated into sensitive photodetector which allows detection of low-energy infrared photons, without resorting to cryogenic cooling.

Srivastava, S. K.↗

Suitability of commercially available laboratory cryogenic refrigerators to support shipboard electro-optical systems in the 10 - 77 Kelvin region

The primary development of cryogenically cooled infrared systems was accomplished by FLIR systems designed for airborne, passive night vision. Essential to the development of these FLIR systems was a family of closed cycle refrigerators which had to meet a limited envelope requirement, utilize a nonlubricated compressor module, and be light in weight. Closed cycle refrigerators accomplished the same cooling function, they use modified oil lubricated reciprocating compressors which are limited in their axis of orientation to an angle of approximately 15-20 degrees maximum from horizon.

Hansen, R. G.↗

Atomic hydrogen for low temperature atomic hydrogen masers and in-vacuum dissociators for VLG-11 series masers

The operation of a cryogenically-cooled hydrogen maser using an RF plasma dissociator operating at liquid nitrogen temperature (77K) in confunction with a state selector magnet whose dimensions are suitable for slow atoms is studied. The focusing characteristics for a hexapole state selector magnet with maximum fields at the pole tips, provide a maximum acceptance angle for atoms at the most probable velocity in the beam. By thermally isolating the RF circuitry from the dissociator glassware, only dielectric losses in the glass and the energy coupled to the plasma will result in the boil-off of liquid nitrogen. It is estimated that this is about one watt and thus a loss rate of approximately .022 liters pr hour is anticipated.

Vessot, R. F. C.↗

Double arch mirror study. Part 2: Engineering analysis report

A method of mounting a cryogenically cooled, lightweight, double arch, class mirror for infrared, astronomical telescopes was developed. A 50 cm, fused silica mirror was modified for use in a new mount configuration. The flexures and the finite element analysis of the mirror stresses are reported.

Iraninejad, B.↗