At least 307 records · Page 17

Cryogenic Optical Performance of a Lightweighted Mirror Assembly for Future Space Astronomical Telescopes: Correlating Optical Test Results and Thermal Optical Model

A 43cm diameter stacked core mirror demonstrator was interferometrically tested at room temperature down to 250 degrees Kelvin for thermal deformation. The 2.5m radius of curvature spherical mirror assembly was constructed by low temperature fusing three abrasive waterjet core sections between two CNC pocket milled face sheets. The 93% lightweighted Corning ULE® mirror assembly represents the current state of the art for future UV, optical, near IR space telescopes. During the multiple thermal test cycles, test results of interferometric test, thermal IR images of the front face were recorded in order to validate thermal optical model.

Eng, Ron↗

The Origins Space Telescope Cryo-Thermal Architecture

The Origins Space Telescope (OST) is studied as a future Mid- and Far-Infrared flagship-class observatory. OST will cover the wavelength range from 6 to 600 microns. To reach the sky background for 200-micron wavelengths temperatures of 4 degrees Kelvin or lower are required. To achieve this low temperature active cooling is required, along with passive shielding and passive radiation to deep space. Currently two concepts are being studied: Concept 1 with a 9-meter-diameter primary and a suite of 5 extremely capable instruments providing both imaging and spectroscopy over the entire wavelength range. Concept 2 is a more modest sized telescope with a collecting area equivalent to a 5-meter primary, fewer deployments and 3 or 4 instruments also covering the entire wavelength range for imaging and spectroscopy, although with somewhat reduced spectroscopic resolution, and somewhat slower mapping speed. This paper will describe OST Concept 2's cryogenic thermal architecture and thermal model results.

Space Telescope↗

Cryogenics program overview

An overview of the cryogenics program of the Goddard Space Flight Center is given in viewgraph form. Goddard's role and the flight programs requiring cryogenics are outlined. Diagrams are given of the Cosmic Background Explorer, the Broad Band X-Ray Telescope, the Hubble Space Telescope, an adiabatic demagnetization refrigerator, a liquid cryogenic cooler for the Shuttle Glow Experiment, a liquid helium dewar, and the X-ray spectrometer on the Advanced X-Ray Astrophysics Facility.

Castles, Stephen H.↗

Positional repeatability measurements of stepper motors at cryogenic temperatures

For cryogenically-cooled infrared instruments and telescopes employed in space, reliable and predictable motor operations at 4 K in vacuum are in most cases necessary. For the Shuttle Infrared Telescope Facility (SIRTF), stepper motors may be employed in a number of applications. A test facility was designed and built for measuring stepper motor positional repeatability, in vacuum, over a temperature range from ambient to liquid helium temperature. Tests regarding positional repeatability were conducted at different motor speeds, directions of motor rotation, step sizes, and power conditions. In addition, tests were performed with respect to the ability of the motor to remain in a position with no power applied to the motor.

Pompea, S. M.↗

Far-infrared and submillimeter survey of the galactic center and nearby galactic plane

Maps are presented with 12-arcmin resolution of the Galactic Center and adjacent galactic plane, from l(Pc) = 359 deg to l(Pc) = 5 deg. The data were obtained with the Steward Observatory's cryogenically-cooled, balloon-borne telescope. The data are from channels filtered for a bandpass of 70 to 110 microns and for a longpass of wavelength greater than 80 microns. For the typical effective temperature of 25 K of a galactic H II region at this spatial resolution, the effective wavelengths of the channels are 93 microns and 145 microns. Continuous emission is mapped along the galactic plane in both wavelengths. There are two contrasts between the immediate vicinity of SgrA l(Pc) smaller than 1 deg, and the galactic plane in general. Firstly, for l(Pi) greater than 1 deg the galactic plane narrows dramatically at 93 microns, while retaining its width at 145 microns. Secondly, the individual sources at l(Pc) (which are associated with H II regions) have greater peak brightness in the 145-micron channel than the 93-micron channel, while SgrA has approximately equal peak brightness in each. The maps demonstrate the importance of submillimeter wavelengths to galactic surveys.

Campbell, M. F.↗

XRCF Testing Capabilities

The Space Optics Manufacturing Technology Center's X-ray Calibration Facility has been recently modified to test Next Generation Space Telescope (NGST) developmental mirrors at cryogenic temperatures (35 degrees Kelvin) while maintaining capability for performance testing of x-ray optics and detectors. The facility's current cryo-optical testing capability and potential modifications for future support of NGST will be presented.

Reily, Cary↗

Assembly, alignment, and cold focus test methods utilized on CLAES optics

This paper describes the techniques and the equipment used in the assembly and alignment of the Cryogenic Limb Array Etalon Spectrophotometer (CLAES) Telescope and Spectrometer, together with those used to test the system at operating temperatures in order to establish the correct focus for the detector array and other system components. In addition, cryogenic tests were used to determine the stability of the optics over the specified environment, and blur size measurements were performed at operational temperatures.

Dawson, Juan C.↗

Arrays: The Heart and Soul of SIRTIF

This paper describes the status of NASA's Space Infrared Telescope Facility (SIRTF) program. SIRTF will be a cryogenically cooled observatory for infrared astronomy from space and is planned for launch early in the next decade. It will be the first cryogenic observatory to make extensive use of the powerful infrared detector array technology discussed at this conference. We summarize a newly developed SIRTF mission concept and show how the availability of detector arrays has shaped the scientific rationale for SIRTF, and how the arrays themselves have become part of the definition of the SIRTF mission.

SIRTF infrared detector arrays Space Infrared Tele↗

Impact of chopping on image quality in the SIRTF telescope

The initial Phase-A concept for the Space Infrared Telescope Facility (SIRTF), which was established in 1981, is concerned with a cryogenically cooled, 85 cm diameter, f/24 Ritchey-Chretien telescope, followed by a Multiple Instrument Chamber (MIC), containing six scientific instruments. In 1982, the Phase-A concept was reviewed with the aim to assess the technical readiness for the next phase of development. Various areas of concern were subsequently investigated in three parallel studies by industry. Two of the arising questions are considered in the present paper, taking into account the system and technology implications of achieving diffraction-limited resolution at 2 microns, and the limitations on the size of the imaging field under this condition. The conducted study takes into account an evaluation of the different methods of chopping. Attention is given to the telescope parameters, symmetric chopping, asymmetrical chopping, focus and alignment errors, the wavefront-error budget, and image quality.

Bottema, M.↗

Cryogenic mirror analysis

Due to extraordinary distances scanned by modern telescopes, optical surfaces in such telescopes must be manufactured to unimaginable standards of perfection of a few thousandths of a centimeter. The detection of imperfections of less than 1/20 of a wavelength of light, for application in the building of the mirror for the Space Infrared Telescope Facility, was undertaken. Because the mirror must be kept very cold while in space, another factor comes into effect: cryogenics. The process to test a specific morror under cryogenic conditions is described; including the follow-up analysis accomplished through computer work. To better illustrate the process and analysis, a Pyrex Hex-Core mirror is followed through the process from the laser interferometry in the lab, to computer analysis via a computer program called FRINGE. This analysis via FRINGE is detailed.

Nagy, S.↗

Space Infrared Telescope Facility science instruments overview

The Space Infrared Telescope Facility (SIRTF) will contain three cryogenically cooled infrared instruments: the Infrared Array Camera (IRAC), the Infrared Spectrograph (IRS), and the Multiband Infrared Photometer for SIRTF (MIPS). These instruments are sensitive to infrared radiation in the 1.8-1,200 micrometer range. This paper will discuss the three instruments' functional requirements and their accommodation in the SIRTF telescope system.

Bothwell, Mary↗

The Atacama Cosmology Telescope: The Receiver and Instrumentation

The Atacama Cosmology Telescope was designed to measure small-scale anisotropies in the Cosmic Microwave Background and detect galaxy clusters through the Sunyaev-Zel'dovich effect. The instrument is located on Cerro Taco in the Atacama Desert, at an altitude of 5190 meters. A six-met.er off-axis Gregorian telescope feeds a new type of cryogenic receiver, the Millimeter Bolometer Array Camera. The receiver features three WOO-element arrays of transition-edge sensor bolometers for observations at 148 GHz, 218 GHz, and 277 GHz. Each detector array is fed by free space mm-wave optics. Each frequency band has a field of view of approximately 22' x 26'. The telescope was commissioned in 2007 and has completed its third year of operations. We discuss the major components of the telescope, camera, and related systems, and summarize the instrument performance.

Swetz, D. S.↗

The Mid-Infrared Spectrometer on the Infrared Telescope in Space (IRTS) mission

The Mid-Infrared Spectrometer (MIRS) is one of the four focal plane instruments on the Infrared Telescope in Space (IRTS) mission. The instrument has been constructed, tested, and calibrated in the laboratory and is presently scheduled to be launched by a Japanese expendable launch vehicle as part of the Space Flyer Unit-1 mission in early 1995. The wavelength coverage of the MIRS ranges from 4.5 to 11.7 microns, with a spectral resolution of 0.23 to 0.36 microns. With the cryogenically cooled optics of the IRTS telescope assembly, the MIRS will be able to make an extremely sensitive survey of both point-source and extended objects over an estimated 10% of the sky.

Roellig, Thomas L.↗

Cryogenic Optical Performance of a Light-weight Mirror Assembly for Future Space Astronomical Telescopes: Optical Test Results and Thermal Optical Model

A 40 cm diameter mirror assembly was interferometrically tested at room temperature down to 250 degrees Kelvin for thermal deformation. The 2.5 m radius of curvature spherical mirror assembly was constructed by low temperature fusing three abrasive waterjet core sections between two face sheets. The 93% lightweighted Corning ULE mirror assembly represents the current state of the art for future UV, optical, near IR space telescopes. During the multiple thermal test cycles, test results of interferometric test, thermal IR images of the front face were recorded in order to validate thermal optical model.

Eng, Ron↗

The AstroBiology Explorer (ABE) MIDEX Mission Concept: Using Infrared Spectroscopy to Identify Organic Molecules in Space

One of the principal means by which organic compounds are detected and identified in space is by infrared spectroscopy. Past IR telescopic and laboratory studies have shown that much of the carbon in the interstellar medium (ISM) is in complex organic species but the distribution, abundance and evolutionary relationships of these materials are not well understood. The Astrobiology Explorer (ABE) is a MIDEX mission concept designed to conduct IR spectroscopic observations to detect and identify these materials and address outstanding problems in astrobiology, astrochemistry, and astrophysics. ABE's core science program includes observations of planetary nebulae and stellar outflows, protostellar objects, Solar System objects, and galaxies, and lines of sight through dense molecular clouds and the diffuse ISM. ABE is a cryogenically-cooled 60 cm diameter space telescope equipped with 3 cross-dispersed R-2000 spectrometers that share a single common slit. Each spectrometer measures one spectral octave and together cover the entire 2.5-20 micron region simultaneously. The spectrometers use state-of-the-art InSb and Si:As 1024x1024 pixel detectors. ABE would operate in a heliocentric, Earth drift-away orbit and have a core science mission lasting approximately 1.5 years. ABE is currently under study at NASA's Ames Research Center in collaboration with Ball Aerospace and Technologies Corp.

Sandford, Scott A.↗

Photometer dewar system for NASA C141 airborne telescope (Kuiper Flying Observatory)

The design, calibration, and testing of a photometer to be used in an airborne telescope is described. A description of the cryogenics of the photometer is given, and photographs and blueprints of the photometer are included. The photometer is designed with a focal plane beam switching system so that the airplane telescope can be used in a normal optical mode at the bent Cassegrain focus and with the photometer operating in the pressurized cabin of the airplane. The concept was to produce a system which could be used in almost the same manner as ground based infrared photometers and dewars of the O'Brien Observatory at the University of Minnesota.

Ney, E. P.↗

Design and Lessons Learned on the Development of a Cryogenic Pupil Select Mechanism (PSM)

Calibration and testing of the instruments on the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST) is being performed by the use of a cryogenic, full-field, optical simulator that was constructed for this purpose. The Pupil Select Mechanism (PSM) assembly is one of several mechanisms and optical elements that compose the Optical Telescope Element SIMulator, or OSIM. The PSM allows for several optical elements to be inserted into the optical plane of OSIM, introducing a variety of aberrations, distortions, obscurations, and other calibration states into the pupil plane. The following discussion focuses on the details of the design evolution, analysis, build, and test of this mechanism along with the challenges associated with creating a sub arc-minute positioning mechanism operating in an extreme cryogenic environment. In addition, difficult challenges in the control system design will be discussed including the incorporation of closed-loop feedback control into a system that was designed to operate in an open-loop fashion.

PSM Design↗