Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIGESTIVE SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A Comparison of Four- Versus Three-Pass Transjugular Biopsy Using a 19-G Tru-Cut Needle and a Randomized Study Using a Cassette to Prevent Biopsy Fragmentation

Recently, it has been shown that transjugular liver biopsy (TJLB) with three passes gives comparable specimens to percutaneous liver biopsy (PLB). The aim of this study was to evaluate the adequacy of TJLB using four passes in a consecutive series of patients, and whether using a supportive cassette can prevent fragmentation. One hundred consecutive TJLBs in 92 patients (48 transplanted), always using four passes (19-G Tru-Cut), were compared to three-pass TJLBs. The four-pass TJLB specimens were randomized at a 1:1 ratio of liver cores placed in a cassette versus not. The four-pass TJLBs, compared to three-pass TJLBs, resulted in better specimens for length ({>=}25 mm: 50% vs. 35%; p = 0.026) and number of complete portal tracts (CPTs) ({>=}11: 40% vs. 26%; p = 0.027), without a higher complication rate. The four-pass TJLB with {>=}11 CPTs had a median length of 27 mm, and 57% of them longer than 28 mm contained {>=}11 CPTs. Putting the liver biopsy cores into a cassette did not improve the fragmentation rate or adequacy of the specimen (length and number of CPTs) of TJLB. We conclude that at least four passes with TJLB should be performed when liver specimens are needed for grading and staging. Using a supportive cassette did not reduce fragmentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gastrointestinal Amyloidosis Presenting with Multiple Episodes of Gastrointestinal Bleeding

Amyloidosis is characterized by the extracellular deposition of amyloid protein in various organs. Gastrointestinal involvement in amyloidosis is common, but a diagnosis of amyloidosis is often delayed. Severe gastrointestinal hemorrhage in amyloidosis is rare but can be fatal in some cases. We experienced a case of a 49-year-old man who presented with recurrent massive hematochezia. Although embolization was performed eight times for bleeding from different sites of the small intestine, hematochezia did not cease. We report the case, with a review of the literature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Malignant Gastroduodenal Obstruction: Treatment with Self-Expanding Uncovered Wallstent

Purpose: To retrospectively evaluate the clinical effectiveness of a self-expanding uncovered Wallstent in patients with malignant gastroduodenal obstruction. Materials and Methods: Under combined endoscopic and fluoroscopic guidance, 29 patients with a malignant gastroduodenal stenosis were treated with a self-expanding uncovered metallic Wallstent. A dysphagia score was assessed before and after the intervention to measure the success of this palliative therapy. The dysphagia score ranged between grade 0 to grade 4: grade 0 = able to tolerate solid food, grade 1 = able to tolerate soft food, grade 2 = able to tolerate thick liquids, grade 3 = able to tolerate water or clear fluids, and grade 4 = unable to tolerate anything perorally. Stent patency and patients survival rates were calculated. Results: The insertion of the gastroduodenal stent was technically successful in 28 patients (96.5%). After stenting, 25 patients (86.2%) showed clinical improvement by at least one score point. During follow-up, 22 (78.5%) of 28 patients showed no stent occlusion until death and did not have to undergo any further intervention. In six patients (20.6%), all of whom were treated with secondary stent insertions, occlusion with tumor ingrowth and/or overgrowth was observed after the intervention. The median period of primary stent patency in our study was 240 days. Conclusion: Placement of an uncovered Wallstent is clinically effective in patients with malignant gastroduodenal obstruction. Stent placement is associated with high technical success, good palliation effect, and high durability of stent function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unusual Severe Complication Following Transarterial Chemoembolization for Metastatic Malignant Melanoma: Giant Intrahepatic Cyst and Fatal Hepatic Failure

We describe a 45-year-old male patient with malignant melanoma who underwent hepatic arterial chemoembolization due to liver metastases. Four months after the procedure, the patient developed a giant cystic cavity in the liver. Cytologic examination of the cystic fluid retention revealed necrotic tumor material. The fluid was drained by percutaneous catheter, but the patient developed hepatic failure. This case represents another rare complication of transarterial chemoembolization and shows that transarterial chemoembolization may have rare fatal complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Cystgastrostomy as a Single-Step Procedure

The purpose of this study was to evaluate the success of percutaneous transgastric cystgastrostomy as a single-step procedure. We performed a retrospective analysis of single-step percutaneous transgastric cystgastrostomy carried out in 12 patients (8 male, 4 female; mean age 44 years; range 21-70 years), between 2002 and 2007, with large symptomatic pancreatic pseudocysts for whom up to 1-year follow-up data (mean 10 months) were available. All pseudocysts were drained by single-step percutaneous cystgastrostomy with the placement of either one or two stents. The procedure was completed successfully in all 12 patients. The pseudocysts showed complete resolution on further imaging in 7 of 12 patients with either enteric passage of the stent or stent removal by endoscopy. In 2 of 12 patients, the pseudocysts showed complete resolution on imaging, with the stents still noted in situ. In 2 of 12 patients, the pseudocysts became infected after 1 month and required surgical intervention. In 1 of 12 patients, the pseudocyst showed partial resolution on imaging, but subsequently reaccumulated and later required external drainage. In our experience, percutaneous cystgastrostomy as a single-step procedure has a high success rate and good short-term outcomes over 1-year follow-up and should be considered in the treatment of large symptomatic cysts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transhepatic Cutting Balloon Papillotomy for Removal of Common Bile Duct Stones

We report the case of a 66-year-old female who presented with jaundice secondary to recurrent adenocarcinoma of the gallbladder and several common bile duct stones. Percutaneous papillary dilatation was planned to remove the common bile duct stones. Papilla was dilated through the percutaneous approach with an 8-mm peripheral cutting balloon instead of a standard balloon. All the stones were pushed successfully into the duodenum with a saline flush. No complications were encountered. Use of a peripheral cutting balloon for dilatation of the papilla seems to be safe and effective because it has the advantage of controlled incision and dilatation of the target at low pressures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Liver Embolization with Four Different Spherical Embolic Materials: Impact on Inflammatory Tissue and Foreign Body Reaction

We sought to describe and compare material specific inflammatory and foreign body reactions after porcine liver embolization with spherical embolic agents. In 40 animals, superselective liver embolization was performed with four different spherical embolic agents of various sizes: 40-120 {mu}m (Embozene, Embosphere), and 100-300 {mu}m, 500-700 {mu}m, and 700-900 {mu}m (Embozene, Embosphere, Bead Block, and Contour SE, respectively). After 4 or 12 weeks, inflammatory reactions were evaluated microscopically according to the Banff 97 classification. For investigation of foreign body reactions, a newly designed giant cell score was applied. Banff 97 and giant cell scores closely correlated. At 4 weeks, small Embosphere particles (100-300 {mu}m) had a significantly higher Banff 97 score than Embozene, Bead Block, and Contour SE of the corresponding size. After 12 weeks, the calculated differences were not statistically significant. Comparison between the 4-week results and the 12-week results revealed a statistically higher Banff 97 score for Embosphere 100-300 {mu}m after 4 weeks than after 12 weeks (P = 0.02). The overall foreign body reaction was pronounced after embolization with smaller particles, especially in small Embosphere particles. Giant cell numbers with Embosphere 100-300 {mu}m were statistically higher compared with the other materials of corresponding size (P < 0.0001). Inflammatory and giant cell reactions after embolization procedures depend on the embolic material. The overall inflammatory reaction was low. However, marked inflammation was associated with small Embosphere particles at 4 weeks, a finding that might be caused by the allogeneic overcoat. Correspondingly, giant cells indicating a foreign body reaction were more frequently associated with small particle sizes, especially after embolization with small Embosphere particles.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization as an Alternative Treatment of Insulinoma in a Patient with Multiple Endocrine Neoplasia Type 1 Syndrome

Insulinoma is a rare neuroendocrine tumor, most commonly originating from the pancreas, which is either sporadic or familial as a component of multiple endocrine neoplasia type 1 syndrome (MEN1). It is characterized by increased insulin secretion leading to hypoglycemia. Surgical removal is considered the treatment of choice, with limited side effects and relatively low morbidity and mortality, both being improved by the laparoscopic procedure. We present the case of a 30-year-old patient with MEN1 and recurrent insulinoma with severe hypoglycemic episodes who could not be surgically treated due to the adherence of the tumor to large blood vessels and to prior multiple surgical operations. He was treated by repeated embolization using spherical polyvinyl alcohol particles, resulting in shrinkage of the tumor, improvement of the frequency and severity of the hypoglycemic episodes, and better quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal Protection During Percutaneous Thermal Ablation Procedures: Interest of Carbon Dioxide Dissection and Temperature Monitoring

Percutaneous image-guided thermal ablation of tumor is widely used, and thermal injury to collateral structures is a known complication of this technique. To avoid thermal damage to surrounding structures, several protection techniques have been reported. We report the use of a simple and effective protective technique combining carbon dioxide dissection and thermocouple: CO{sub 2} displaces the nontarget structures, and its low thermal conductivity provides excellent insulation; insertion of a thermocouple in contact with vulnerable structures achieves continuous thermal monitoring. We performed percutaneous thermal ablation of 37 tumors in 35 patients (4 laser, 10 radiofrequency, and 23 cryoablations) with protection of adjacent vulnerable structures by using CO{sub 2} dissection combined with continuous thermal monitoring with thermocouple. Tumor locations were various (19 intra-abdominal tumors including 4 livers and 9 kidneys, 18 musculoskeletal tumors including 11 spinal tumors). CO{sub 2} volume ranged from 10 ml (epidural space) to 1500 ml (abdominal). Repeated insufflations were performed if necessary, depending on the information given by the thermocouple and imaging control. Dissection with optimal thermal protection was achieved in all cases except two patients where adherences (one postoperative, one arachnoiditis) blocked proper gaseous distribution. No complication referred to this technique was noted. This safe, cost-effective, and simple method increases the safety and the success rate of percutaneous thermal ablation procedures. It also offers the potential to increase the number of tumors that can be treated via a percutaneous approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Percutaneous Embolization of Bleeding Stomal Varices

Stomal variceal bleeding can develop in patients with underlying cirrhosis and portal hypertension. Most patients are best treated with transjugular intrahepatic portosystemic shunt (TIPS) creation because this addresses the underlying problem of portal hypertension. However, some patients are not good candidates for TIPS creation because they have end-stage liver disease or encephalopathy. We describe such a patient who presented with recurrent bleeding stomal varices, which was successfully treated with percutaneous coil embolization. The patient had bleeding-free survival for 1 month before death from unrelated causes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Radiofrequency Ablation of a Pancreatic Tumor with a New Triple Spiral-Shaped Electrode

Image-guided, minimally invasive treatment modalities have become an area of considerable interest and research during the last few years for the treatment of primary and secondary liver tumors. We report our experience with an unresectable pancreatic tumor, treated with application of radiofrequency ablation under CT guidance that even though a complication occurred during the procedure, had excellent results on follow-up CT scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Treatment with a Covered Stent and 6-Year Follow-Up of Biliary Complication After Liver Transplantation

The role of covered stent in the management of biliary complications is not yet defined in liver transplant recipients. This Case Report presents a patient with anastomotic stricture and leakage with biloma treated with a covered stent 32 months following liver transplantation. Signs of in-stent restenosis developed 52 months following covered stent placement, which was resolved by balloon dilation. There were no complications during the interventions. The latest follow-up, at 69 months following primary and 19 months following secondary percutaneous intervention, shows a patent covered stent without any clinical or morphological sign of further restenosis. The clinical success with long-term follow-up data suggests that covered stent implantation can be a rational, minimally invasive option for simultaneous treatment of bile duct stenosis and bile leak following liver transplantation in selected cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Rhenium-188, Gemcitabine, and 5-Fluorouracil on Cholangiocellular Carcinoma Cells: An In Vitro Study

The purpose of this study was to compare the beneficial effects of radioactive stents and radioactive stents plus additional chemotherapy in the palliative treatment of cholangiocellular carcinomas. Cholangiocellular carcinoma cells (TFK-1 cells) were treated either with 8 Gy (RTB group) or 16 Gy (RTA group) {sup 188}Re or with {sup 188}Re irradiation (8 Gy) combined with either gemcitabine (8 Gy/Gem) or 5-fluorouracil (8 Gy/5-FU) at a dosage of 20 {mu}g/ml medium for 4 days and subsequently compared with an untreated control group. Proliferation kinetics were assessed on days 4, 7, 11, 18, 25, and 32. Colony formation assays were performed on days 7, 18, and 32 and cell cycle distribution was examined on days 4, 7, 11, 15, 25, and 39. Cell proliferation kinetics showed the lowest cell numbers in the 8 Gy/5-FU group (control, 15,390,000; RTA group, 8,394,000; RTB group, 5,609,000; 8 Gy/Gem group, 423,000; and 8 Gy/5-FU group, 297,667). In contrast, clonogenic activity on day 32 was lower in the 8 Gy/Gem group (control, 29.3 colonies; RTB group, 23.1 colonies; 8 Gy/5-FU group, 21.5 colonies; 8 Gy/Gem, 3.3 colonies; and even augmented in the RTA group, with 37.7 colonies). Cell cycle distribution showed similar curves for all groups on slightly different levels except for the 8 Gy/5-FU group, which showed a relatively augmented percentage of cells on day 7 in the G2 M cycle phase and on day 4 in the S phase. In conclusion, irradiation (8 Gy) with {sup 188}Re administered, e.g., via coated stents, combined with Gem could be a valid option for the treatment of CCCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Primary Patency of Wallstents in Malignant Bile Duct Obstruction: Single vs. Two or More Noncoaxial Stents

The purpose of this study was to determine the primary patency of two or more noncoaxial self-expanding metallic Wallstents (Boston Scientific, Natick, MA) and to compare this with the primary patency of a single stent in malignant bile duct obstruction. From August 2002 to August 2004, 127 patients had stents placed for malignant bile duct obstruction. Forty-five patients were treated with more than one noncoaxial self-expanding metallic stents and 82 patients had a single stent placed. Two patients in the multiple-stent group were lost to follow-up. The primary patency period was calculated from the date of stenting until the first poststenting intervention for stent occlusion, death, or the time of last documented follow-up. The patency of a single stent was significantly different from that of multiple stents (P = 0.0004). In the subset of patients with high bile duct obstruction, the patency of a single stent remained significantly different from that of multiple stents (P = 0.02). In the single-stent group, there was no difference in patency between patients with high vs. those with low bile duct obstruction (P = 0.43). The overall median patency for the multistent group and the single-stent group was 201 and 261 days, respectively. In conclusion, the patency of a single stent placed for malignant low or high bile duct obstruction is similar, and significantly longer than, that of multiple stents placed for malignant high bile duct obstruction. Given the median patency of 201 days, when indicated, percutaneous stenting of multiple bile ducts is an effective palliative measure for patients with malignant high bile duct obstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transcholecystic Placement of an ePTFE/FEP-Covered Stent in the Common Bile Duct

We report the case of a 78-year-old male patient with obstructive jaundice due to a pancreatic head neoplasm. The patient's general condition did not permit an endoscopic approach and the presence of diffuse liver metastases prohibited hepatic puncture for percutaneous biliary drainage, therefore the transcolecystic transperitoneal approach was decided to be the safest decompression route. Through a gallbladder access, a Viabil-covered stent with a mesh extension was placed in the distal common bile duct, without complications. The patient died 8 months later without signs of stent dysfunction or necessity of reintervention. Transcholecystic transperitoneal access is a safe option when diffuse liver metastases prohibit the transhepatic approach, even in cases where placement of a covered stent is considered necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Malignant Jaundice Due to Extrahepatic Cholangiocarcinoma: Covered Viabil Stent Versus Uncovered Wallstents

To compare clinical effectiveness of Viabil-covered stents versus uncovered metallic Wallstents, for palliation of malignant jaundice due to extrahepatic cholangiocarcinoma, 60 patients were enrolled in a prospective and randomized study. In half of the patients a bare Wallstent was used, and in the other half a Viabil biliary stent. Patients were followed up until death. Primary patency, survival, complication rates, and mean cost were calculated in both groups. Stent dysfunction occurred in 9 (30%) patients in the bare stent group after a mean period of 133.1 days and in 4 (13.3%) patients in the covered stent group after a mean of 179.5 days. The incidence of stent dysfunction was significantly lower in the covered stent group (P = 0.046). Tumor ingrowth occurred exclusively in the bare stent group (P = 0.007). Median survival was 180.5 days for the Wallstent and 243.5 days for the Viabil group (P = 0.039). Complications and mean cost were similar in the two groups. Viabil stent-grafts proved to be significantly superior to Wallstents for the palliation of malignant jaundice due to extrahepatic cholangiocarcinoma, with comparable cost and complication rates. Appropriate patient selection should be performed prior to stent placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transvenous Embolization to Treat Uncontrolled Hemobilia and Peritoneal Bleeding After Transjugular Liver Biopsy

Hemobilia is one of the complications that can occur after a transjugular liver biopsy. Various treatment options have been described for the management of this condition, including transarterial embolization and open surgery. We describe a patient who developed uncontrolled hemobilia after a transjugular liver biopsy that required a transvenous approach for embolization and treatment purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗