Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease

Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.

Software↗

Devices based on surface plasmon interference filters

Devices based on surface plasmon filters having at least one metal-dielectric interface to support surface plasmon waves. A multi-layer-coupled surface plasmon notch filter is provided to have more than two symmetric metal-dielectric interfaces coupled with one another to produce a transmission spectral window with desired spectral profile and bandwidth. Such notch filters can form various color filtering devices for color flat panel displays.

Wang, Yu↗

High-resolution, continuous field-of-view (FOV), non-rotating imaging system

A high resolution CMOS imaging system especially suitable for use in a periscope head. The imaging system includes a sensor head for scene acquisition, and a control apparatus inclusive of distributed processors and software for device-control, data handling, and display. The sensor head encloses a combination of wide field-of-view CMOS imagers and narrow field-of-view CMOS imagers. Each bank of imagers is controlled by a dedicated processing module in order to handle information flow and image analysis of the outputs of the camera system. The imaging system also includes automated or manually controlled display system and software for providing an interactive graphical user interface (GUI) that displays a full 360-degree field of view and allows the user or automated ATR system to select regions for higher resolution inspection.

Huntsberger, Terrance L.↗

A New Process for Fabricating Random Silicon Nanotips

An improved process for the fabrication of random arrays of silicon nanotips has been demonstrated to be feasible. Relative to other such processes, this process offers advantages of low cost and simplicity. Moreover, this process can readily be combined with other processes used to fabricate integrated circuits and other monolithic silicon structures. Arrays of silicon nanotips are subjects of research and development efforts directed toward utilizing them as field emitters in flat-panel displays, vacuum microelectronics, and microwave devices. Other silicon-nanotip-fabrication processes developed thus far predominantly include lithography, etching, and/or elaborate deposition steps followed by oxide sharpening steps and are both process intensive as well as expensive. In addition to being cheaper and simpler, the present process can efficiently produce silicon nanotips that range in height from a few microns to several tens of microns and are distributed over large areas. The process mentioned here can be summarized as consisting of (1) the growth of micro-etch masks on a silicon substrate, followed by (2) etching away of the masks, along with some of the substrate, to make an array of sharp tips. In the first step of the process, a cleaned silicon substrate is subjected to reactive ion etching (RIE) in a certain mixture of oxygen and carbon tetrafluoride under radio-frequency excitation. This process step results in the growth of fluorine based compounds in the form of stumps randomly distributed on the substrate. These stumps are known in the art as polymer RIE grass. The dimensions of these stumps are of the order of hundreds of nanometers, the exact values depending on process time and gas composition. The areal density of the stumps decreases with increasing process time as they grow and merge with neighboring stumps. These stumps constitute the micro-etch masks for the next step of the process. In the second step of the process, the substrate covered with the microetch masks is subjected to deep reactive ion etching (DRIE) process, which consists of cycles of reactive ion etching alternating with passivation (the Bosch process). The gas used in the etching substeps is sulfur hexafluoride (SF6); the gas used in the passivation substeps is octafluorocyclobutane (C4F8). The portions of the substrate directly under the RIE grass stubs are etched more slowly than are the portions between the stubs. Hence, what remains at the end of the process, after the stubs and parts of the substrate have been etched away, are silicon spikes where the stubs were (see figure). In a variation of the process, one starts with a silicon or silicon-on-insulator substrate with the intent to etch through the full thickness of the substrate. That is to say, one chooses the thickness so that the DRIE step releases individual nanotips. Such individual silicon nanotips may have utility as microscopic probes in biomedical applications.

Manohara, Harish↗

Motion Sickness and Concerns for Urban Air Mobility Vehicles: A Literature Review

Motion sickness is a general term for a constellation of signs and symptoms, generally due to exposure to abrupt, periodic, or unnatural accelerations, especially when traveling in a vehicle. Motion sickness results from a mismatch of the visual and nonvisual (vestibular and kinesthetic) information, the observed scene and the motion felt or lack of it. Motion sickness onset is associated with a pattern of physiological changes in heart rate, peripheral blood flow, respiration, and skin conductance and the pattern is repeatable for a particular subject but variable between subjects. Demographic factors such as gender and age that affect motion sickness are well known with children, women, and older adults more likely to be susceptible. Often motion sickness is assessed and quantified using variations of the motion sickness susceptibility questionnaires including the Pensacola Diagnostic Rating Scale and the Simulator Sickness Questionnaire. Even though symptoms are easily identified by such questionnaires, they commonly are subjective. Tools such as these questionnaires for screening individuals susceptible to motion sickness are useful, however, they are only mildly predictive. Moreover, models for predicting motion sickness, which have largely been developed for sea sickness, do not consider task characteristics. Predictions of motion sickness rates and prevalence for Urban Air Mobility (UAM) vehicles are not possible at present because data from actual flight or full-fidelity simulation are simply not yet available. Extrapolation from other modes of transportation (i.e., automobiles, buses, trains, boats, other types of aircraft) is difficult because of differences in the motion stimulus experienced, trip duration, and other factors. How UAM vehicles will change the social dynamics of passenger interaction and vehicle interior design changes (e.g., seat orientations) is unknown. Should motion sickness prove to be an issue, vehicle design modifications such as having passengers face forward, providing additional seat recline, giving each person their own climate control for airflow, perhaps ensuring the horizon is visible to all passengers (reducing visual occlusion by the headrest) and visually stabilizing displays on carry-on devices (smart phones, tablets, etc.) may benefit passengers. Several commercial companies provide wearable devices for physiological monitoring that have been validated and are suitable for use with passengers in UAM vehicles or high-fidelity simulators. Potential countermeasures for motion sickness include user-worn devices, anti-motion sickness medications, and non-pharmacological approaches such as biofeedback and Autogenic Feedback Training Exercise. Both simulator and in-vehicle UAM research is needed to evaluate the effectiveness of any potential countermeasure.

motion sickness↗

Methods and apparatus for graphical display and editing of flight plans

Systems and methods are provided for an integrated graphical user interface which facilitates the display and editing of aircraft flight-plan data. A user (e.g., a pilot) located within the aircraft provides input to a processor through a cursor control device and receives visual feedback via a display produced by a monitor. The display includes various graphical elements associated with the lateral position, vertical position, flight-plan and/or other indicia of the aircraft's operational state as determined from avionics data and/or various data sources. Through use of the cursor control device, the user may modify the flight-plan and/or other such indicia graphically in accordance with feedback provided by the display. In one embodiment, the display includes a lateral view, a vertical profile view, and a hot-map view configured to simplify the display and editing of the aircraft's flight-plan data.

Gibbs, Michael J.↗

Visual specification of robot motion

The authors describe the use of stereo pairs of images to specify robot motion. The experimental setup includes a SUN workstation, a PUMA 560 robot, and an Imaging 151 vision system. An X-window environment displays stereo images of the work scene. Image processing is performed to extract linear edge segments from the images and the results are displayed on screen. Using a pointing device, the user selects a group of edges from the object relevant to the task. The 3D structure of this group of features is found by stereo triangulation and they can be displayed in 3D from any point of view. A viewpoint orthogonal to the plane defined by these 3D edges is used to specify the robot position relative to object position. The actual robot will then be moved to the specified position.

Shiu, Y. C.↗

Micro-video display with ocular tracking and interactive voice control

In certain space-restricted environments, many of the benefits resulting from computer technology have been foregone because of the size, weight, inconvenience, and lack of mobility associated with existing computer interface devices. Accordingly, an effort to develop a highly miniaturized and 'wearable' computer display and control interface device, referred to as the Sensory Integrated Data Interface (SIDI), is underway. The system incorporates a micro-video display that provides data display and ocular tracking on a lightweight headset. Software commands are implemented by conjunctive eye movement and voice commands of the operator. In this initial prototyping effort, various 'off-the-shelf' components have been integrated into a desktop computer and with a customized menu-tree software application to demonstrate feasibility and conceptual capabilities. When fully developed as a customized system, the interface device will allow mobile, 'hand-free' operation of portable computer equipment. It will thus allow integration of information technology applications into those restrictive environments, both military and industrial, that have not yet taken advantage of the computer revolution. This effort is Phase 1 of Small Business Innovative Research (SBIR) Topic number N90-331 sponsored by the Naval Undersea Warfare Center Division, Newport. The prime contractor is Foster-Miller, Inc. of Waltham, MA.

Miller, James E.↗

Liquid Crystal on Silicon Wavefront Corrector

A low cost, high resolution, liquid crystal on silicon, spatial light modulator has been developed for the correction of huge aberrations in an optical system where the polarization dependence and the chromatic nature are tolerated. However, the overall system performance suggests that this device is also suitable for real time correction of aberration in human eyes. This device has a resolution of 1024 x 768, and is driven by an XGA display driver. The effective stroke length of the device is 700 nm and 2000 nm for the visible and IR regions of the device, respectively. The response speeds are 50 Hz and 5 Hz, respectively, which are fast enough for real time adaptive optics for aberrations in human eyes. By modulating a wavefront of 2 pi, this device can correct for arbitrary high order wavefront aberrations since the 2-D pixel array is independently controlled by the driver. The high resolution and high accuracy of the device allow for diffraction limited correction of the tip and tilt or defocus without an additional correction loop. We have shown that for every wave of aberration, an 8 step blazed grating is required to achieve high diffraction efficiency around 80%. In light of this, up to 125 waves peak to valley of tip and tilt can be corrected if we choose the simplest aberration. Corrections of 34 waves of aberration, including high order Zernicke terms in a high magnification telescope, to diffraction limited performance (residual wavefront aberration less than 1/30 lambda at 632.8 nm) have been observed at high efficiency.

Pouch, John↗

Electrically Reconfigurable Liquid Metal Nanophotonic Platform for Color Display and Imaging

Dynamically tunable optical materials and device architectures are essential for future photonic technologies, yet conventional solid metals lack the intrinsic tunability required for advanced functionalities. Gallium-based liquid metals (LMs) present an appealing alternative thanks to their distinctive mechanical and optical properties; however, their practical integration in tunable photonic elements remains largely unexplored. Here, in this study, an electrochemically controlled nanophotonic platform is demonstrated that integrates a dynamically reconfigurable LM ground plane with gold nanoantenna arrays within a microfluidic system, enabling precise and reversible modulation of optical resonances across the visible to mid-infrared spectral ranges. By employing moderate operational voltages (1.5–3.0 V), real-time tuning of high-resolution structural color patterns is achieved through nanoscale control of the interfacial gap between the LM and Au nanoantennas. This innovative platform facilitates electrically programmable, high-contrast color patterns suitable for dynamic optical displays, secure anti-counterfeiting labels, and imaging applications. Additionally, this platform enables tunable mid-infrared spectral responses, which may be utilized for chemical and biological sensing applications. This versatile integrated LM-based nanophotonic platform opens new paths toward multifunctional, actively tunable/reconfigurable photonic device and system technologies.

Imaging↗

Nucleation and Growth of Blue Phase 3D Cubic Structure Under Continuously Changing Curved Boundary Conditions

The blue phase of liquid crystals (BPLCs) with a cubic lattice of disclination lines and 3D nanostructure enables the modulation of photonic bandgap thus casting them in the category of photonic crystals. Its unique nature promises applications in display technologies, electro‐optics, and sensors. To integrate these ordered materials into wearable devices a fundamental understanding of curvature, and spatial confinement is necessary. Although continuous confinement in flat geometries have been studied, confining curvature has shown to induce strong destabilization effects on the cubic structure and formation of topological defects, thereby deteriorating their optical performance. Moreover, limitations in controlling the curvature of droplets further hinder studies of nucleation and growth of BPLCs. Here, to address these challenges, micro‐scale patterned surfaces of concentric cylinders are exploited to systematically control curvatures. The impact of curvature on the confined BPLCs is revealed in terms of phase transition temperature, nucleation and growth, morphology, as well as phase transformation. This research offers valuable insights into the stability, and structural characteristics of BPLCs in adaptive photonic devices, paving the way for future advancements in flexible displays, sensors, and other technologies leveraging liquid crystal (LC) materials.

3D Cubic Structure↗

Promoting Real-Time Science in the Classroom using Wireless PDA Technology

The year is 2004, NASA has landed and deployed a fleet of rovers on the surface of Mars to continue the exploration of that planet and prepare the way for human visitors. Middle school students at Milton Elementary have been following the mission through the media and Internet as part of Mr. Johnson's Earth and space sciences class. The kids have been working in teams to track the rovers as they move across the surface of Mars on a scale model of the landing site they built from sand and rocks using pictures and video downloaded from the Internet. They also built their own version of a rover that can be driven around the model. The time is 3:36pm. Jim and a couple of his fellow students from class are sitting in the cafeteria waiting for a student council meeting to begin. Mary and several others are on the bus riding home. Kathy is in her father's car waiting to leave the parking lot. On Mars, Rover-3 has just stopped and issued an alert to ground control at NASA's Jet Propulsion Laboratory (JPL). Back at Milton Elementary chimes can be heard going off in the cafeteria, on the school bus, and in Kathy's car. The students are familiar with the drill and each brings up the Mars mission status display on their hand-held PDA device. They've been using their PDAs (those Palm devices that seem to be everywhere today) to obtain real-time position information for each of the rovers throughout the mission. The mission status display tells them that Rover-3 has stopped on the edge of a small gully and isn't quite sure what to do. The students begin considering the options amongst themselves. Should the rover just drive through the gully? If it does, what happens if it gets stuck? Maybe it should turnaround and look for away around the gully? Trough questions. Real questions. Real problems. The students know they will need to be prepared to discuss the options and conduct their own simulations using the models they built in Mr. Johnson's class tomorrow. Much the same way engineers and scientists will be working to solve the problem at NASA. It's a couple of days later, NASA has made a decision on what to do and has issued new commands for Rover-3 to execute at 9:15am Milton Elementary time. Interestingly, NASA's solution to the problem differs from the one favored by the students. 9:16am, chimes can be heard going off throughout Milton Elementary.

Matusow, David↗

Stereo Imaging Miniature Endoscope with Single Imaging Chip and Conjugated Multi-Bandpass Filters

A dual objective endoscope for insertion into a cavity of a body for providing a stereoscopic image of a region of interest inside of the body including an imaging device at the distal end for obtaining optical images of the region of interest (ROI), and processing the optical images for forming video signals for wired and/or wireless transmission and display of 3D images on a rendering device. The imaging device includes a focal plane detector array (FPA) for obtaining the optical images of the ROI, and processing circuits behind the FPA. The processing circuits convert the optical images into the video signals. The imaging device includes right and left pupil for receiving a right and left images through a right and left conjugated multi-band pass filters. Illuminators illuminate the ROI through a multi-band pass filter having three right and three left pass bands that are matched to the right and left conjugated multi-band pass filters. A full color image is collected after three or six sequential illuminations with the red, green and blue lights.

Shahinian, Hrayr Karnig↗

Stimulus factors in motion perception and spatial orientation

The Malcolm horizon utilizes a large projected light stimulus Peripheral Vision Horizon Device (PVHD) as an attitude indicator in order to achieve a more compelling sense of roll than is obtained with smaller devices. The basic principle is that the larger stimulus is more similar to visibility of a real horizon during roll, and does not require fixation and attention to the degree that smaller displays do. Successful implementation of such a device requires adjustment of the parameters of the visual stimulus so that its effects on motion perception and spatial orientation are optimized. With this purpose in mind, the effects of relevant image variables on the perception of object motion, self motion and spatial orientation are reviewed.

Post, R. B.↗

Enhanced Low Dose Rate Sensitivity at Ultra-Low Dose Rates

We have presented results of ultra-low dose rate irradiations (< or = 10 mrad(Si)/s) for a variety of radiation hardened and commercial linear bipolar devices. We observed low dose rate enhancement factors exceeding 1.5 in several parts. The worst case of dose rate enhancement resulted in functional failures, which occurred after 10 and 60 krad(Si), for devices irradiated at 0.5 and 10 mrad(Si)/s, respectively. Devices fabricated with radiation hardened processes and designs also displayed dose rate enhancement at below 10 mrad(Si)/s. Furthermore, the data indicated that these devices have not reached the damage saturation point. Therefore the degradation will likely continue to increase with increasing total dose, and the low dose rate enhancement will further magnify. The cases presented here, in addition to previous examples, illustrate the significance and pervasiveness of low dose rate enhancement at dose rates lower than 10 mrad(Si). These results present further challenges for radiation hardness assurance of bipolar linear circuits, and raise the question of whether the current standard test dose rate is conservative enough to bound degradations due to ELDRS.

Chen, Dakai↗

Display management subsystem, version 1: A user's eye view

The structure and application functions of the Display Management Subsystem (DMS) are described. The DMS, a subsystem of the Transportable Applications Executive (TAE), was designed to provide a device-independent interface for an image processing and display environment. The system is callable by C and FORTRAN applications, portable to accommodate different image analysis terminals, and easily expandable to meet local needs. Generic applications are also available for performing many image processing tasks.

Parker, Dolores↗

Surface Energy Modulated Self‐Assembly of Percolative Gallium Nanodroplet Films for Stretchable Electronics

Advancements in soft robotics and wearable technologies have led to an increased need for flexible and stretchable electronic systems. Liquid metals like Gallium (Ga) and its alloys offer high potential in the field of stretchable electronics and photonics due to their inherent high conductivity and malleability. However, their high surface tension and native oxide formation hinder uniform wetting and continuous film formation to get conducting films. Here, we report a fabrication strategy to realize electrically conductive Ga thin films with effective thicknesses around 100 nm on polymeric and elastomeric substrates. By enhancing the surface energy of the elastomer, we create uniform Ga nanodroplets capable of sustaining stretchability up to 200% strain. Our devices exhibit electronic conduction primarily through tunneling and display strain tunable piezoresistive characteristics, which are explained using Kirchhoff's resistive network and Simmon's analytical tunneling current model. To showcase the device's capability in fields of stretchable electronics, we demonstrate several functional prototypes, including flexible devices integrated with Light Emitting Diodes (LEDs), curvature and pressure sensors, and soft robotic grippers capable of sensing object curvature. The demonstrated devices highlight the potential of this approach for scalable integration of stretchable electronics in soft robotic and wearable platforms.

42 ENGINEERING↗

EPICS for small-scale laboratories with Python soft IOCs

While the Experimental Physics and Industrial Control System (EPICS) is widely used at large laboratories for slow controls and instrumentation, the deployment of a full EPICS installation can be difficult, with a steep learning curve to new users. Taking advantage of the pythonSoftIOC module, we developed an EPICS slow controls implementation for Jefferson Lab's Hall B cryotarget written entirely in Python and based on software IOCs that communicate with instruments over Ethernet. Here, this system ran successfully, interfacing with Jefferson Lab's full EPICS network, and we offer it as an example of the capabilities of pythonSoftIOC to build lightweight, yet robust and flexible instrumentation platforms that would be easily adapted for use at a small-scale laboratory. University groups can use these examples to build complete slow controls systems, from device communication to data archiving and display, using open-source, mature EPICS tools and student-friendly Python as an alternative to expensive and proprietary systems such as LabVIEW.

Computing↗