Somatic Mutation in Mice on the International Space Station (ISS): Guanine Substitution Suggests Link to Cancer Risk

We conducted comprehensive analysis of single nucleotide somatic mutations in mice exposed to microgravity and other factors aboard the International Space Station (ISS), using data archived in GeneLab. Animals in the experimental cohort consisted of mice that spent 37 days on the ISS within the Rodent Habitat. Ground control animals consisted of mice of identical age, sex, strain, in a terrestrial Rodent Habitat controlled for temperature, humidity and carbon dioxide levels, to match ISS conditions as closely as possible. RNA extracted from eye, liver, skeletal muscle, and kidney tissue specimens was subjected to next-generation sequencing to acquire primary data. Our analysis employed cutting-edge software developed at NASA Ames Research Center, executed on the NASA Ames Supercomputer and on another high-performance computer, for accurate variant calling of single point mutations. ISS-flown mice exhibited a notably heightened level of somatic mutation compared to control mice. The degree of somatic mutation correlated with the degree of gene expression across the four tissue types, i.e., the greatest rate of mutation accumulation was seen in highly expressed genes. We discovered that guanine substitutions were the most common type of somatic mutation. This observation is consistent with the hypothesis that DNA mutation events stem from reactive oxygen/nitrogen/chlorine species-mediated guanine oxidation induced by the spaceflight environment. Since guanine oxidation is a prominent feature of the DNA mutation landscape that accompanies malignant transformation, our findings suggest a possible link between the spaceflight environment and cancer risk that is independent of radiation carcinogenesis.

ISS↗

Ionospsheric observation of enhanced convection-initiated gravity waves during tornadic storms

Atmospheric gravity waves associated with tornadoes, with locally severe storms occuring with tornadoes, and with hurricanes were studied through the coupling between the ionosphere and the troposphere. Reverse group ray tracing computations of gravity waves observed by an ionospheric Doppler sounder array were analyzed. The results of ray tracing computations and comparisons between the computed location of the wave sources and with conventional meteorological data indicate that the computed sources of the waves were near the touchdown of the tornadoes, near the eye of the hurricanes, and directly on the squall line of the severe thunderstorms. The signals excited occurred one hour in advance of the tornadoes and three hours in advance of the hurricanes. Satellite photographs show convective overshooting turrets occurring at the same locations and times the gravity waves were being excited. It is suggested that gravity wave observations, conventional meteorological data, and satellite photographs be combined to develop a remote sensing technique for detecting severe storms.

Hung, R. J.↗

Systems analysis of the vestibulo-ocular system

The vestibulo-ocular system is examined from the standpoint of system theory. The evolution of a mathematical model of the vestibulo-ocular system in an attempt to match more and more experimental data is followed step by step. The final model explains many characteristics of the eye movement in vestibularly induced nystagmus. The analysis of the dynamic behavior of the model at the different stages of its development is illustrated in time domain, mainly in a qualitative way.

Schmid, R. M.↗

Space telescope

This paper describes the Space Telescope, a program of the National Aeronautics and Space Administration (NASA). The Space Telescope is the largest and most powerful optical and ultraviolet astronomical observatory to be operated in space. Through the remote eyes of this telescope, astronomers will look further into space and time to produce data including imagery of unequaled quality of galaxies, star systems, quasars and other objects of scientific interest. The Space Telescope will do this by observing the sky from a nominal 550 kilometer low earth orbit via an optical system with a 2.4 meter diameter primary mirror. Additionally, this observatory has a precision pointing control system that is capable of maintaining a locked state on an object for extended periods accurately to within 0.01 arc seconds. The observatory instrument complement, optical system and pointing control system is presented.

Wojtalik, F. S.↗

Improving survival after tissue vaporization (Ebullism)

Exposure of unprotected humans to altitudes above 63,000 ft results in ebullism. Ebullism occurs when the vapor pressure of tissues is less than the ambient pressure and the tissues spontaneously 'boil'. This may result in rapid unconsciousness, cardiac vaporlock, pulmonary collapse, cerebral anoxia, and sometimes even death. Potential places for this include EVA accidents in space, aircraft experiencing rapid decompression at high altitudes with cabin or pressure suit failure, and accidents during pressure suit training exercises. The pathophysiology of ebullism was studied in the 40's to 60's using animal models. There is one report of a prolonged, unprotected human exposure and several anecdotal of unprotected short term exposures to near vacuum. In addition to pulmonary and neurologic concerns, unprotected exposure of the head may result in freezing of the corneal surface of the eye. Surface eye freezing may impair vision and significantly impact mission completion. At this time, little data are available on the effectiveness of conventional treatment protocols, such as hyperbaric oxygen, for ebullism induced injuries. Research is needed to assess the efficacy of other adjunctive therapies such as high frequency ventilation and cerebral protective drugs that are still under development.

Stegmann, Barbara J.↗

Archeological Surveys

NASA remote sensing technology is being employed in archeological studies of the Anasazi Indians, who lived in New Mexico one thousand years ago. Under contract with the National Park Service, NASA's Technology Applications Center at the University of New Mexico is interpreting multispectral scanner data and demonstrating how aerospace scanning techniques can uncover features of prehistoric ruins not visible in conventional aerial photographs. The Center's initial study focused on Chaco Canyon, a pre-Columbia Anasazi site in northeastern New Mexico. Chaco Canyon is a national monument and it has been well explored on the ground and by aerial photography. But the National Park Service was interested in the potential of multispectral scanning for producing evidence of prehistoric roads, field patterns and dwelling areas not discernible in aerial photographs. The multispectral scanner produces imaging data in the invisible as well as the visible portions of the spectrum. This data is converted to pictures which bring out features not visible to the naked eye or to cameras. The Technology Applications Center joined forces with Bendix Aerospace Systems Division, Ann Arbor, Michigan, which provided a scanner-equipped airplane for mapping the Chaco Canyon area. The NASA group processed the scanner images and employed computerized image enhancement techniques to bring out additional detail.

Source record↗

First Image Products from EcoSAR - Osa Peninsula, Costa Rica

Designed especially for forest ecosystem studies, EcoSAR employs state-of-the-art digital beamforming technology to generate wide-swath, high-resolution imagery. EcoSARs dual antenna single-pass imaging capability eliminates temporal decorrelation from polarimetric and interferometric analysis, increasing the signal strength and simplifying models used to invert forest structure parameters. Antennae are physically separated by 25 meters providing single pass interferometry. In this mode the radar is most sensitive to topography. With 32 active transmit and receive channels, EcoSARs digital beamforming is an order of magnitude more versatile than the digital beamforming employed on the upcoming NISAR mission. EcoSARs long wavelength (P-band, 435 MHz, 69 cm) measurements can be used to simulate data products for ESAs future BIOMASS mission, allowing scientists to develop algorithms before the launch of the satellite. EcoSAR can also be deployed to collect much needed data where BIOMASS satellite wont be allowed to collect data (North America, Europe and Arctic), filling in the gaps to keep a watchful eye on the global carbon cycle. EcoSAR can play a vital role in monitoring, reporting and verification schemes of internationals programs such as UN-REDD (United Nations Reducing Emissions from Deforestation and Degradation) benefiting global society. EcoSAR was developed and flown with support from NASA Earth Sciences Technology Offices Instrument Incubator Program.

InSAR↗

A Multi-Faceted Approach to Demonstrating Multi-Functional Integrated Medical Devices to Advance Earth-Independent Medical Operations

INTRODUCTION TO MIM DEVICES Multi-functional Integrated Medical (MIM) devices conveniently incorporate multiple medical system capabilities within one device. The NASA Exploration Medical Integrated Product Team (XM-IPT) sponsored a market survey and trade study which identified the Tempus ProTM and the LifeBot 10® as the MIM devices that best met the evaluation criteria of the trade study. The Tempus ProTM (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) and LifeBot 10® (LifeBot Health, Chicago, IL) both provide vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature along with ultrasound imaging. A video laryngoscopy capability is unique to the Tempus ProTM, while the LifeBot 10® supports connectivity with a digital stethoscope, otoscope, eye exam camera, and dermatoscope. Both devices include procedural guidance capabilities and have various data transmission and report generation features. TECHNOLOGY DEMONSTRATIONS NASA’s exploration-class missions will have severe resource constraints, long return trip durations, significant communication delays, and limited resupply opportunities. The medical systems of these missions will need to fit within an Earth-Independent Medical Operations (EIMO) construct. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. Evaluations are underway to determine if it will be beneficial to include MIM devices within exploration medical systems by conducting a series of planned technical demonstrations. Exploration Atmosphere Chamber studies are being performed to determine MIM functionality in a high oxygen concentration atmosphere. A side-by-side comparison of the Tempus ProTM and LifeBot 10® will be performed during ground-based demonstrations. Use of the MIM devices within an EIMO medical scenario simulation will be practiced during ground-based demonstrations in preparation for International Space Station (ISS) demonstrations of the MIM device. These various demonstrations are designed to gather evidence for or against the inclusion of MIM devices within an EIMO medical system. EXPECTED DEMONSTRATION OUTCOMES Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis. Information will also be collected about performance differences as available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities, which take the EIMO construct into consideration.

B. E. Lewandowski↗

Clipping polygon faces through a polyhedron of vision

A flight simulator combines flight data and polygon face terrain data to provide a CRT display at each window of the simulated aircraft. The data base specifies the relative position of each vertex of each polygon face therein. Only those terrain faces currently appearing within the pyramid of vision defined by the pilots eye and the edges of the pilots window need be displayed at any given time. As the orientation of the pyramid of vision changes in response to flight data, the displayed faces are correspondingly displaced, eventually moving out of the pyramid of vision. Faces which are currently not visible (outside the pyramid of vision) are clipped from the data flow. In addition, faces which are only partially outside of pyramid of vision are reconstructed to eliminate the outside portion. Window coordinates are generated defining the distance between each vertex and each of the boundary planes forming the pyramid of vision. The sign bit of each window coordinate indicates whether the vertex is on the pyramid of vision side of the associated boundary panel (positive), or on the other side thereof (negative). The set of sign bits accompanying each vertex constitute the outcode of that vertex. The outcodes (O.C.) are systematically processed and examined to determine which faces are completely inside the pyramid of vision (Case A--all signs positive), which faces are completely outside (Case C--All signs negative) and which faces must be reconstructed (Case B--both positive and negative signs).

Rohner, Michel A.↗

Observations and impressions from lunar orbit

On Apollo 16, the command module pilot made observations of particular surface features and processes to complement photographic and other remotely sensed data. Emphasis was placed on geological problems that required the extreme dynamic range and color sensitivities of the human eye; repetitive observations of varying sun angles and viewing directions; and, in some cases, on-the-scene interpretations. Visual observations and impressions recorded during the mission verified the effectiveness of the hardware and techniques used. The orbiting observer functioned both as a sensor, in otherwise inaccessible areas such as earthshine and shadows, and as a designator of potentially significant data that were acquired on the photographic record.

Mattingly, T. K.↗

A Lagrangian trajectory view on transport and mixing processes between the eye, eyewall, and environment using a high resolution simulation of Hurricane Bonnie (1998)

The transport and mixing characteristics of a large sample of air parcels within a mature and vertically sheared hurricane vortex is examined. Data from a high-resolution (2 km grid spacing) numerical simulation of "real-case" Hurricane Bonnie (1998) is used to calculate Lagrangian trajectories of air parcels in various subdomains of the hurricane (namely, the eye, eyewall, and near-environment) to study the degree of interaction (transport and mixing) between these subdomains. It is found that 1) there is transport and mixing from the low-level eye to the eyewall that carries high- Be air which can enhance the efficiency of the hurricane heat engine; 2) a portion of the low-level inflow of the hurricane bypasses the eyewall to enter the eye, that both replaces the mass of the low-level eye and lingers for a sufficient time (order 1 hour) to acquire enhanced entropy characteristics through interaction with the ocean beneath the eye; 3) air in the mid- to upper-level eye is exchanged with the eyewall such that more than half the air of the eye is exchanged in five hours in this case of a sheared hurricane; and 4) that one-fifth of the mass in the eyewall at a height of 5 km has an origin in the mid- to upper-level environment where thet(sub e) is much less than in the eyewall, which ventilates the ensemble average eyewall theta(sub e) by about 1 K. Implications of these findings to the problem of hurricane intensity forecasting are discussed.

Cram, Thomas A.↗

Deep Gaze Velocity Analysis During Mammographic Reading for Biometric Identification of Radiologists

Several studies have confirmed that the gaze velocity of the human eye can be utilized as a behavioral biometric or personalized biomarker. In this study, we leverage the local feature representation capacity of convolutional neural networks (CNNs) for eye gaze velocity analysis as the basis for biometric identification of radiologists performing breast cancer screening. Using gaze data collected from 10 radiologists reading 100 mammograms of various diagnoses, we compared the performance of a CNN-based classification algorithm with two deep learning classifiers, deep neural network and deep belief network, and a previously presented hidden Markov model classifier. The study showed that the CNN classifier is superior compared to alternative classification methods based on macro F1-scores derived from 10-fold cross-validation experiments. Our results further support the efficacy of eye gaze velocity as a biometric identifier of medical imaging experts.

59 BASIC BIOLOGICAL SCIENCES↗

Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique

Purpose: This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Methods: Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings. Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. Results: ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%–20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head) relative to SmartmA. Conclusions: ODM reduced dose in all experimental and simulation studies over a range of phantoms, while increasing noise. The results suggest a net dose/noise benefit for breast and eye lens for all studied phantoms, negligible lung dose effects for two phantoms, increased lung dose and/or noise for eight phantoms, and increased dose and/or noise for brain and spine for all studied phantoms compared to the reference protocol.

60 APPLIED LIFE SCIENCES↗

Off-Angle Iris Correction Methods

In many real world iris recognition systems obtaining consistent frontal images is problematic do to inexperienced or uncooperative users, untrained operators, or distracting environments. As a result many collected images are unusable by modern iris matchers. In this chapter we present four methods for correcting off-angle iris images to appear frontal which makes them compatible with existing iris matchers. The methods include an affine correction, a retraced model of the human eye, measured displacements, and a genetic algorithm optimized correction. The affine correction represents a simple way to create an iris image that appears frontal but it does not account for refractive distortions of the cornea. The other method account for refraction. The retraced model simulates the optical properties of the cornea. The other two methods are data driven. The first uses optical flow to measure the displacements of the iris texture when compared to frontal images of the same subject. The second uses a genetic algorithm to learn a mapping that optimizes the Hamming Distance scores between off-angle and frontal images. In this paper we hypothesize that the biological model presented in our earlier work does not adequately account for all variations in eye anatomy and therefore the two data-driven approaches should yield better performance. Results are presented using the commercial VeriEye matcher that show that the genetic algorithm method clearly improves over prior work and makes iris recognition possible up to 50 degrees off-angle.

iris recognition↗

Looking at Hubble Through the Eyes of JWST

The phase retrieval algorithm developed for the James Webb Space Telescope (JWST) is used to process archival image data that was originally used to characterize the Hubble primary mirror edge defect. The Hubble mirror conic constant is inferred from these results and comparisons are made with earlier conic values reported by teams comprising the HARP (Hubble Aberration Recovery Project) study. A number of important lessons learned from the Hubble phase retrieval problem are described and a discussion is given on how these have been incorporated into the JWST Observatory design.

Dean, Bruce H.↗

Thresholds for Shifting Visually Perceived Eye Level Due to Incremental Pitches

Visually perceived eye level (VPEL) was judged by subjects as they viewed a luminous grid pattern that was pitched by 2 or 5 deg increments between -20 deg and +20 deg. Subjects were dark adapted for 20 min and indicated--VPEL by directing the beam of a laser pointer to the rear wall of a 1.25 m cubic pitch box that rotated about a horizontal axis midpoint on the rear wall. Data were analyzed by ANOVA and the Tukey HSD procedure. Results showed a 10.0 deg threshold for pitches P(sub i) above the reference pitch P(sub 0), and a -10.3 deg threshold for pitches P(sub i) below-the reference-pitch P(sub 0). Threshold data for pitches P(sub i) < P(sub 0) suggest an asymmetric threshold for VPEL below and above physical eye level.

Scott, Donald M.↗

Summary of results and conclusions based on analysis of volume imaging and high spectral resolution lidar data acquired during FIRE phase 1, part 2

Since the fall of 1986, cirrus clouds were observed with backscatter cross sections ranging from less than 1 x 10(exp -7) to 4.2 x 10(exp -5)m/sr, optical thicknesses ranging from less than .003 to greater than 2.7, and bulk average backscatter phase functions from .02 to .065/sr. Cirrus cloud structures were recorded ranging in vertical extent from 0.1 to 8 km, having horizontal scales from 10's of meters to 266 km, and exhibiting aspect ratios of from 1:5 to 1:100. The altitude relationship between cloud top and bottom boundaries and the optical center of the cloud is influenced by the type of formation observed. Cirrus morphology and generation processes appear to be related to the wind field. The high spectral resolution lidar (HSRL) was adapted to the task of cirrus cloud optical property measurement. The HSRL data reported were collected with the CuCl2 transmitter producing 50 mW of output power, achieving eye safe, direct optical depth and backscatter cross section measurements with 10 minute averaging times.

Grund, Christian J.↗

Micro-video display with ocular tracking and interactive voice control

In certain space-restricted environments, many of the benefits resulting from computer technology have been foregone because of the size, weight, inconvenience, and lack of mobility associated with existing computer interface devices. Accordingly, an effort to develop a highly miniaturized and 'wearable' computer display and control interface device, referred to as the Sensory Integrated Data Interface (SIDI), is underway. The system incorporates a micro-video display that provides data display and ocular tracking on a lightweight headset. Software commands are implemented by conjunctive eye movement and voice commands of the operator. In this initial prototyping effort, various 'off-the-shelf' components have been integrated into a desktop computer and with a customized menu-tree software application to demonstrate feasibility and conceptual capabilities. When fully developed as a customized system, the interface device will allow mobile, 'hand-free' operation of portable computer equipment. It will thus allow integration of information technology applications into those restrictive environments, both military and industrial, that have not yet taken advantage of the computer revolution. This effort is Phase 1 of Small Business Innovative Research (SBIR) Topic number N90-331 sponsored by the Naval Undersea Warfare Center Division, Newport. The prime contractor is Foster-Miller, Inc. of Waltham, MA.