Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Nonstochastic magnetic reversal in artificial quasicrystalline spin ice

We have measured the isothermal DC magnetization of Penrose P2 tilings (P2T) composed of wire segments of permalloy thin film. Micromagnetic simulations reproduce the coercive fields and “knee anomalies” observed in experimental data and show magnetic shape anisotropy constrains segments to be single-domain (Ising spins) at low fields, similar to artificial spin ice (ASI). Mirror symmetry controls the initial reversal of individual segments oriented parallel to the applied field, followed by complex switching of multiple adjacent segments (“avalanches”) of various orientations such that closed magnetization loops (“vortices”) are favored. Ferromagnetic P2T differ from previously studied ASI systems due to their aperiodic translational symmetry and numerous inequivalent pattern vertices, which drive nonstochastic switching of segment polarizations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Focused Ion Beam Tomography of Alloy 617 Corroded in Molten Chloride Salt

Materials qualification of reactor structural materials is a critical step in rapid implementation of advanced nuclear reactor technologies, particularly to assess the corrosion performance in these designs. Accelerated qualification of reactor structural materials requires incorporating powerful computational toolsets, such as phase field modelling in the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework, to predict the evolution of structural materials due to corrosion. Accordingly, computational toolsets will require experimental data generated at appropriate length scales to validate accuracy. Focused ion beam (FIB) provides a high degree of control over manipulation of materials for analytical purposes, including capturing data on the evolution in the microstructure and elemental composition of materials at the mesoscale, an appropriate length scale for phase field modelling of intergranular diffusion phenomena using the MOOSE framework. For instance, the FEI Helios G4 UX dual beam plasma FIB microscope at the Irradiated Materials Characterization Laboratory (IMCL) is capable of backscatter diffraction (EBSD) and energy-dispersive x-ray spectroscopy (EDS) documenting the evolution in the microstructure and elemental composition, respectively. The Helios can perform EDS and EBSD three-dimensionally (3D) using tomography, which is then combined using different software packages to visualize 3D volumes correlating elemental composition to microstructural data. The purpose of this investigation was to develop a streamlined characterization and data processing workflow for 3D tomography studies on the FEI Helios G4 plasma FIB. The investigation is segmented into three parts: 1) Optimizing the data collection workflow, 2) identifying appropriate data processing and visualization software (i.e. DREAM.3D, MIPAR, and VGStudioMax), and 3) establishing an infrastructure for public release. The optimization of the data collection workflow is in collaboration with members of the U220 department to setup formal training on the tomography operation of the G4, through ThermoFisher Scientific, and exploring DREAM.3D, MIPAR, and VGStudioMax data processing/visualization software packages. VGStudioMax currently demonstrates the most promise for future use. Optimization of the data collection and processing workflow is still ongoing. A collaboration with INL High Performance Computing (HPC) established an open-source license for expediting the public release of FIB tomography datasets through HPC. FIB tomography data generated by the G4 will provide comprehensive data for validating 3D phase field mesoscale modelling tools within the MOOSE framework for accelerated qualification of reactor structural materials.

Copeland-Johnson, Trishelle↗

Automated segmentation and analysis of point clouds of pier foundations using Pier Inspection and Evaluation Report (PIER)

Pier foundations are commonly used in locations with unstable soil or where other types of foundations are unsuitable or cost prohibitive. A pier foundation consists of vertical columns to support the structure and elevate it above the ground. Common materials for pier foundations include masonry, concrete, timber, and steel. The methods for accurate placement of pier foundations have remained relatively unchanged for decades. For simple installations, construction chalk lines are used to layout the locations of piers to ensure accurate placement and elevation. For more complex installations, surveying instruments operated by trained professionals are employed to accurately locate piers and assess correct elevation before construction. After installation, another survey may need to be performed to assess the quality of the as-built foundation. However, with the advent of terrestrial laser scanners (TLS), the means now exist for contractors to conduct their own assessments of as-built foundations. The major barrier preventing contractors from performing their own assessments of as-built foundation quality is the segmentation and analysis of point cloud data, a skill that often requires a trained user. The objective of this research is to develop a software tool (PIER: Pier Inspection and Evaluation Report) to enable automated segmentation and analysis of point clouds of pier foundations. In this paper, the automated segmentation and analysis algorithms are detailed. A mockup lay out of pier foundations was built using concrete masonry units, and the algorithms were tested to evaluate performance. Limitations of the current algorithms and future research direction are discussed.

Turki, Amine [ORNL]↗

Automatic Point Cloud Building Envelope Segmentation (AutoCuBES)

The Auto-CuBES algorithm is based on unsupervised machine learning that automatically labels 3D point cloud data and reduces the time spent in manual segmentation. The algorithm can process high-resolution point clouds and generate a wire-frame building envelope model with a small set of calibration parameters. The algorithm inputs a 3D point cloud generated by commonly available surveying equipment and outputs a wire-frame model of the building envelope. Unsupervised machine learning methods were used to identify facades, windows, and doors while minimizing the number of calibration parameters.

Puente, BryanMaldonado↗

Predicting Search Task Difficulty through a Discrete‐Time Action Log Representation on Spectrum Kernel

ABSTRACT Predicting perceived difficulty on a web search task is an open problem in the interactive information retrieval field. A common approach to tackle it, is through features obtained from full search sessions, which are then used to train classification models. In this poster we attempt to predict perceived task difficulty at different stages of the search process. To do so, we use the spectrum kernel for support vector machine (SVM) classification. Our preliminary results suggest that by using behavioral data from the first query segment, it is possible to provide timely classifications of whether a search task is perceived as hard or easy.

Gacitúa, Daniel↗

Differentiation of pancreatic neuroendocrine tumors from pancreas renal cell carcinoma metastases on CT using qualitative and quantitative features

Purpose: To assess qualitative and quantitative imaging features on enhanced CT that may differentiate pancreatic neuroendocrine tumors (PNETs) from pancreatic renal cell carcinoma (RCC) metastases. Methods: This IRB-approved multi-center retrospective case–control study compared 43 resected PNETs and 28 resected RCC metastases with pre-operative enhanced CT identified consecutively between 2003 and 2017. Two blinded radiologists (R1/R2) independently assessed tumor location, attenuation (relative to pancreas), composition (solid/cystic/mixed), homogeneity (homogeneous/heterogeneous), calcification, multiplicity, and for main pancreatic duct (MPD) dilation. Tumors were segmented for quantitative texture analysis. Data were analyzed with Chi square, logistic regression, and receiver operating characteristic (ROC). Inter-observer agreement was assessed (Cohen’s kappa). Results: There was no difference in age, gender, location, attenuation, or composition (P > 0.05) between groups. PNETs were larger than RCC metastases (37 ± 23 mm vs. 26 ± 21 mm, P = 0.038), more frequently solitary (P < 0.001), subjectively more heterogeneous (P = 0.033/0.144, R1/R2), and associated with calcification (P = 0.002/0.004) and MPD dilation (P = 0.025/0.006). Agreement for subjective features was moderate-to-almost perfect (K = 0.4879–0.9481). Quantitative texture analysis showed higher entropy in PNETs (6.32 ± 0.49 versus 5.96 ± 0.53; P = 0.004) with no difference in other features studied (P > 0.05). Entropy had ROC area under the curve for diagnosis of PNET of 0.77 ± 0.06, with optimal sensitivity/specificity of 71.4/79.1%. Conclusions: Compared to pancreatic RCC metastases, PNETs are larger, more frequently solitary, contain calcification, show MPD dilation, and are subjectively and quantitatively more heterogeneous tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solution NMR and X-ray Crystal Structures of Membrane-associated Lipoprotein-17 Domain Reveal a Novel Fold

The conserved Lipoprotein-17 domain of membrane-associated protein Q9PRA0{_}UREPA from Ureaplasma parvum was selected for structure determination by the Northeast Structural Genomics Consortium, as part of the Protein Structure Initiative's program on structure-function analysis of protein domains from large domain sequence families lacking structural representatives. The 100-residue Lipoprotein-17 domain is a 'domain of unknown function' (DUF) that is a member of Pfam protein family PF04200, a large domain family for which no members have characterized biochemical functions. The three-dimensional structure of the Lipoprotein-17 domain of protein Q9PRA0{_}UREPA was determined by both solution NMR and by X-ray crystallography at 2.5 {angstrom}. The two structures are in good agreement with each other. The domain structure features three {alpha}-helices, {alpha}1 through {alpha}3, and five {beta}-strands. Strands {beta}1/{beta}2, {beta}3/{beta}4, {beta}4/{beta}5 are anti-parallel to each other. Strands {beta}1 and {beta}2 are orthogonal to strands {beta}3, {beta}4, {beta}5, while helix {alpha}3 is formed between the strands {beta}3 and {beta}4. One-turn helix {alpha}2 is formed between the strands {beta}1 and {beta}2, while helix {alpha}1 occurs in the N-terminal polypeptide segment. Searches of the Protein Data Bank do not identify any other protein with significant structural similarity to Lipoprotein-17 domain of Q9PRA0{_}UREPA, indicating that it is a novel protein fold.

59 BASIC BIOLOGICAL SCIENCES↗

Geometrical characterization of perlite-metal syntactic foam

This paper introduces an improved method for the detailed geometrical characterization of perlite-metal syntactic foam. This novel metallic foam is created by infiltrating a packed bed of expanded perlite particles with liquid aluminium alloy. The geometry of the solidified metal is thus defined by the perlite particle shape, size and morphology. The method is based on a segmented micro-computed tomography data and allows for automated determination of the distributions of pore size, sphericity, orientation and location. The pore (i.e. particle) size distribution and pore orientation is determined by a multi-criteria k-nearest neighbour algorithm for pore identification. The results indicate a weak density gradient parallel to the casting direction and a slight preference of particle orientation perpendicular to the casting direction. - Highlights: •A new method for identification of pores in porous materials was developed. •It was applied on perlite-metal syntactic foam samples. •A porosity decrease in the axial direction of the samples was determined. •Pore shape analysis showed a high percentage of spherical pores. •Orientation analysis showed that more pores are oriented in the radial direction.

36 MATERIALS SCIENCE↗

Assessing XMT-Measurement Variability of Air-Water Interfacial Areas in Natural Porous Media

This study investigates the accuracy and reproducibility of air-water interfacial areas measured with high-resolution synchrotron X-ray microtomography (XMT). Columns packed with one of two relatively coarse-grained monodisperse granular media, glass beads or a well-sorted quartz sand, were imaged over several years, encompassing changes in acquisition equipment, improved image quality, and enhancements to image acquisition and to processing software. For the glass beads, the specific solid surface area (SSSA-XMT) of 31.6 ± 1 cm -1 determined from direct analysis of the segmented solid-phase image data is statistically identical to the independently calculated geometric smooth-sphere specific solid surface area (GSSA, 32 ± 1 cm -1 ) and to the measured SSSA (28 ± 3 cm -1 ) obtained with the N2-Brunauer, Emmett, and Teller method. The maximum specific air-water interfacial area (Amax) is 27.4 (±2) cm -1 , which compares very well to the SSSA-XMT, GSSA, and SSSA-N2-Brunauer, Emmett, and Teller values. For the sand, the SSSA-XMT (111 ± 2 cm -1 ) and GSSA (113 ± 1 cm -1 ) are similar. The mean Amax is 96 ± 5 cm -1 , which compares well to both the SSSA and the GSSA values. The XMT-SSSA values deviated from the GSSA values by 7–16% for the first four experiments but were essentially identical for the later experiments. This indicates that enhancements in image acquisition and processing improved data accuracy. The Amax values ranged from 74 cm -1 to 101 cm -1 , with a coefficient of variation (COV) of 9%. The maximum capillary interfacial area ranged from 12 cm-1 to 19 cm -1 , for a COV of 10%. The COVs for both decreased to 5–6% for the latter five experiments. These results demonstrate that XMT imaging provides accurate and reproducible measurements of total and capillary interfacial areas.

54 ENVIRONMENTAL SCIENCES↗

A novel use of frequency-banded synthetic aperture focusing technique for reconstructions of alkali-silica reaction in thick-reinforced concrete structures

As they degrade and age, concrete structures are susceptible to the development of multiple defects, such as alkali-silica reaction (ASR). ASR forms a gel that occurs over time between alkaline cement paste and reactive, noncrystalline silica in aggregates [1]. With the continuing extension of the life span of nuclear power plants, it is important to monitor the structural integrity of concrete structures after 40+ years. Compression strength, modulus of elasticity, flexural stiffness, shear strength, and tensile strength are performance characteristics susceptible to the development of ASR. Current methods for monitoring for defects and degradation within thick concrete structures require damaging the concrete. Oak Ridge National Laboratory, in collaboration with the University of Pittsburgh, has developed a nondestructive evaluation (NDE) and reconstruction technique that enables deep-image reconstruction of damaged concrete. The frequency-banded synthetic aperture focusing technique (FB-SAFT) is an augmented SAFT reconstruction that segments the time-series data into different frequency bands using wavelets immediately before performing SAFT reconstructions [2]. This paper presents the NDE instrumentation and reconstruction techniques applied to thick-reinforced concrete structures and concludes with preliminary results.

Ezell, N Dianne↗

Human-in-the-Loop: The Future of Machine Learning in Automated Electron Microscopy

Machine learning (ML) methods are progressively gaining acceptance in the electron microscopy community for de-noising, semantic segmentation, and dimensionality reduction of data post-acquisition. The introduction of the application programming interfaces (APIs) by major instrument manufacturers now allows the deployment of ML workflows in microscopes, not only for data analytics but also for real-time decision-making and feedback for microscope operation. However, the number of use cases for real-time ML remains remarkably small. Furthermore, we discuss some considerations in designing ML-based active experiments and pose that the likely strategy for the next several years will be human-in-the-loop automated experiments (hAE). In this paradigm, the ML learning agent directly controls beam position and image and spectroscopy acquisition functions, and a human operator monitors experiment progression in real and feature space of the system and tunes the policies of the ML agent to steer the experiment toward specific objectives.

47 OTHER INSTRUMENTATION↗

MO-D-213-02: Quality Improvement Through a Failure Mode and Effects Analysis of Pediatric External Beam Radiotherapy

Purpose: To conduct a failure mode and effects analysis (FMEA) as per AAPM Task Group 100 on clinical processes associated with teletherapy, and the development of mitigations for processes with identified high risk. Methods: A FMEA was conducted on clinical processes relating to teletherapy treatment plan development and delivery. Nine major processes were identified for analysis. These steps included CT simulation, data transfer, image registration and segmentation, treatment planning, plan approval and preparation, and initial and subsequent treatments. Process tree mapping was utilized to identify the steps contained within each process. Failure modes (FM) were identified and evaluated with a scale of 1–10 based upon three metrics: the severity of the effect, the probability of occurrence, and the detectability of the cause. The analyzed metrics were scored as follows: severity – no harm = 1, lethal = 10; probability – not likely = 1, certainty = 10; detectability – always detected = 1, undetectable = 10. The three metrics were combined multiplicatively to determine the risk priority number (RPN) which defined the overall score for each FM and the order in which process modifications should be deployed. Results: Eighty-nine procedural steps were identified with 186 FM accompanied by 193 failure effects with 213 potential causes. Eighty-one of the FM were scored with a RPN > 10, and mitigations were developed for FM with RPN values exceeding ten. The initial treatment had the most FM (16) requiring mitigation development followed closely by treatment planning, segmentation, and plan preparation with fourteen each. The maximum RPN was 400 and involved target delineation. Conclusion: The FMEA process proved extremely useful in identifying previously unforeseen risks. New methods were developed and implemented for risk mitigation and error prevention. Similar to findings reported for adult patients, the process leading to the initial treatment has an associated high risk.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-06: Texture Feature Reproducibility Between PET/CT and PET/MR Imaging Modalities

Purpose: Radiomics involves the extraction of texture features from different imaging modalities with the purpose of developing models to predict patient treatment outcomes. The purpose of this study is to investigate texture feature reproducibility across [18F]FDG PET/CT and [18F]FDG PET/MR imaging in patients with primary malignancies. Methods: Twenty five prospective patients with solid tumors underwent clinical [18F]FDG PET/CT scan followed by [18F]FDG PET/MR scans. In all patients the lesions were identified using nuclear medicine reports. The images were co-registered and segmented using an in-house auto-segmentation method. Fifty features, based on the intensity histogram, second and high order matrices, were extracted from the segmented regions from both image data sets. One-way random-effects ANOVA model of the intra-class correlation coefficient (ICC) was used to establish texture feature correlations between both data sets. Results: Fifty features were classified based on their ICC values, which were found in the range from 0.1 to 0.86, in three categories: high, intermediate, and low. Ten features extracted from second and high-order matrices showed large ICC ≥ 0.70. Seventeen features presented intermediate 0.5 ≤ ICC ≤ 0.65 and the remaining twenty three presented low ICC ≤ 0.45. Conclusion: Features with large ICC values could be reliable candidates for quantification as they lead to similar results from both imaging modalities. Features with small ICC indicates a lack of correlation. Therefore, the use of these features as a quantitative measure will lead to different assessments of the same lesion depending on the imaging modality from where they are extracted. This study shows the importance of the need for further investigation and standardization of features across multiple imaging modalities.

60 APPLIED LIFE SCIENCES↗

SU-F-I-01: Normalized Mean Glandular Dose Values for Dedicated Breast CT Using Realistic Breast-Shaped Phantoms

Purpose: To estimate normalized mean glandular dose values for dedicated breast CT (DgN-CT) using breast CT-derived phantoms and compare to estimations using cylindrical phantoms. Methods: Segmented breast CT (bCT) volume data sets (N=219) were used to measure effective diameter profiles and were grouped into quintiles by volume. The profiles were averaged within each quintile to represent the range of breast sizes found clinically. These profiles were then used to generate five voxelized computational phantoms (V1, V2, V3, V4, V5 for the small to large phantom sizes, respectively), and loaded into the MCNP6 lattice geometry to simulate normalized mean glandular dose coefficients (DgN-CT) using the system specifications of the Doheny-prototype bCT scanner in our laboratory. The DgN-CT coefficients derived from the bCT-derived breast-shaped phantoms were compared to those generated using a simpler cylindrical phantom using a constant volume, and the following constraints: (1) Length=1.5*radius; (2) radius determined at chest wall (Rcw), and (3) radius determined at the phantom center-of-mass (Rcm). Results: The change in Dg-NCT coefficients averaged across all phantom sizes, was - 0.5%, 19.8%, and 1.3%, for constraints 1–3, respectively. This suggests that the cylindrical assumption is a good approximation if the radius is taken at the breast center-of-mass, but using the radius at the chest wall results in an underestimation of the glandular dose. Conclusion: The DgN-CT coefficients for bCT-derived phantoms were compared against the assumption of a cylindrical phantom and proved to be essentially equivalent when the cylinder radius was set to r=1.5/L or Rcm. While this suggests that for dosimetry applications a patient’s breast can be approximated as a cylinder (if the correct radius is applied), this assumes a homogenous composition of breast tissue and the results may be different if the realistic heterogeneous distribution of glandular tissue is considered. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.

60 APPLIED LIFE SCIENCES↗

Technical Note: Development of a 3D printed subresolution sandwich phantom for validation of brain SPECT analysis

Purpose: To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. Methods: A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain by adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding {sup 99m}Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. Results: Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. Conclusions: The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable for use in PET.

60 APPLIED LIFE SCIENCES↗

Deep Learning Image Segmentation for Atmospheric Rivers

Abstract The identification of atmospheric rivers (ARs) is crucial for weather and climate predictions as they are often associated with severe storm systems and extreme precipitation, which can cause large impacts on society. This study presents a deep learning model, termed ARDetect, for image segmentation of ARs using ERA5 data from 1960 to 2020 with labels obtained from the TempestExtremes tracking algorithm. ARDetect is a convolutional neural network (CNN)-based U-Net model, with its structure having been optimized using automatic hyperparameter tuning. Inputs to ARDetect were selected to be the integrated water vapor transport (IVT) and total column water (TCW) fields, as well as the AR mask from TempestExtremes from the previous time step to the one being considered. ARDetect achieved a mean intersection-over-union (mIoU) rate of 89.04% for ARs, indicating its high accuracy in identifying these weather patterns and a superior performance than most deep learning–based models for AR detection. In addition, ARDetect can be executed faster than the TempestExtremes method (seconds vs minutes) for the same period. This provides a significant benefit for online AR detection, especially for high-resolution global models. An ensemble of 10 models, each trained on the same dataset but having different starting weights, was used to further improve on the performance produced by ARDetect, thus demonstrating the importance of model diversity in improving performance. ARDetect provides an effective and fast deep learning–based model for researchers and weather forecasters to better detect and understand ARs, which have significant impacts on weather-related events such as floods and droughts.

Galea, Daniel↗

NucMesh: nuclear reactor geometry creation and mesh generation module in NEMoSys

NucMesh is a parameterized geometry and mesh generator for nuclear reactors developed within the Nuclear Energy Modeling System NEMoSys at Illinois Rocstar. NEMoSys is a platform developed for mesh generation, adaptive refinement, and solution verification. NucMesh is implemented to be generalized and extensible with a robust computer aided design engine and multiple mesh generation algorithms for unstructured triangular, quad-dominant, and structured quadrilateral meshing. In this paper, we present the geometric and meshing features of NucMesh. Geometrically objects are constructed bottom-to-top and overlaps are addressed automatically. A sophisticated object tracking algorithm prevents data from being lost for segmented objects. We discuss the primitive objects of circle and polygons that constitute the module and show how they are used with example inputs. Arrays of primitives and arrays of arrays are utilized to build large assemblies of objects. The concept of saved objects is discussed to demonstrate how repetitive objects can be reused easily and augmented in place. Three dimensional meshes can be obtained through mesh extrusion where all materials and side sets are extended to three dimensions. We show that side sets can be defined nearly anywhere within the geometry and can then be applied to the mesh. Finally, example reactor meshes are demonstrated for the Idaho National Laboratory Advanced Test Reactor and Los Alamos National Lab Empire reactor, both of which use control drums that NucMesh handles easily. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fine-tuning TrailMap: The utility of transfer learning to improve the performance of deep learning in axon segmentation of light-sheet microscopy images

Light-sheet microscopy has made possible the 3D imaging of both fixed and live biological tissue, with samples as large as the entire mouse brain. However, segmentation and quantification of that data remains a time-consuming manual undertaking. Machine learning methods promise the possibility of automating this process. This study seeks to advance the performance of prior models through optimizing transfer learning. We fine-tuned the existing TrailMap model using expert-labeled data from noradrenergic axonal structures in the mouse brain. By changing the cross-entropy weights and using augmentation, we demonstrate a generally improved adjusted F1-score over using the originally trained TrailMap model within our test datasets.

97 MATHEMATICS AND COMPUTING↗