Operation of the mark 1 x-ray tube at elevated temperatures
Mark 1 X-ray tube operation at high temperatures to determine maximum temperature limit for operation in lunar X-ray diffractometer
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Mark 1 X-ray tube operation at high temperatures to determine maximum temperature limit for operation in lunar X-ray diffractometer
Sample preparation for X-ray diffractometer and guidelines for sample selection and handling of lunar rock specimens for analysis
Acquisition and transport components of X-ray diffractometer sampler breadboard
Feasibility of total iron analysis by X-ray fluorescence detection in X-ray diffractometer
The Sector 7 undulator beamline (7-ID) of the Advanced Photon Source (APS) is dedicated to time-resolved x-ray research and is capable of ultrafast measurements on the order of 100 ps. Beamline 7-ID has a laser laboratory featuring a Ti:Sapphire system (average power of 2.5W, pulse duration <50 fs, repetition rate 1-5 kHz) that can be synchronized to the bunch pattern of the storage ring. The laser is deliverable to x-ray enclosures, which contain diffractometers, as well as motorized optical tables for table-top experiments. Beamline 7-ID has a single APS Undulator A and uses a diamond (111) double-crystal monochromator, providing good energy resolution over a range of 6-24 keV. Available optics include Kirkpatrick-Baez (KB) mirrors to microfocus the x-ray beam. A variety of time-resolved diffraction and spectroscopy research is available at 7-ID, with experiments being done in the atomic, molecular, optical, chemistry, and solid state (bulk and surface) fields.
Using hollow cylinder samples with suitable geometry obtained from round bar stock, the deformation behavior of bcc Fe based 12L14 steel alloy is evaluated under multi-axial conditions. A stacked strain gage rosette and extensometer mounted on the cylindrical surface at the mid height of the specimen provided strain tensor as a function of applied stress for pure tensile and torsion tests prior to yielding. This study examines elastic and yield behavior and effects of these with respect to texture evolution. Hollow cylinder specimen geometry (tubes) with small wall thickness and relatively (to its thickness) large inner diameter is used. The variation of observed yield surface in deviatoric plane and the effect on mode of deformation (tension versus torsion versus its combination) on stress-strain behavior is discussed. Bulk texture was studied using neutron time-of-flight diffractometer at High-Pressure-Preferred Orientation (HIPPO) - Los Alamos Neutron Science Center (LANSCE) instrument and the evolution of texture and related anisotropy for pure tension versus torsion are also included.
We have utilized the SMARTS engineering neutron diffractometer to study the crystallographic orientation and phase transformations in the ferromagnetic shape memory alloy Ni 2MnGa under conditions of temperature (200-600K), stress (500MPa), and magnetic field (2T). Neutrons are uniquely suited to probe the crystallographic response of materials to external stimuli because of their high penetration, which allows them to sample the bulk of the material (as opposed to the surface) as well as pass through environmental chambers. A single crystal of Ni{sub 5}MnGa was repeatedly thermally cycled through the Austenitic-Martensitic phase transformation under varying conditions of applied stress, magnetic field or both. In-situ neutron diffraction was used to quantitatively monitor the population of the crystallographic variants in the martensitic phase as a function of the external stimuli during cooling. Neutron diffraction was used to monitor variant selection in the Ferromagnetic Shape Memory Alloy Ni{sub 2}Mn Ga during austenitic to martensitic transformation under varying conditions of externally applied stress and magnetic field. Qualitatively, the results were to be expected in this simple example. The shorter and magnetically soft c-axis of the tetragonal martensitic phase aligned with the compressive stress or magnetic field. However, neutron diffraction proved useful in directly quantifying the selection of the preferred variant by external influence. For instance, by quantifying the variant selection, the neutron diffraction results made apparent that the sample 'remembered' a loading cycle following a 'reset' cycle with no external applied stress. Moreover, the power of in-situ neutron diffraction will become more apparent when applied to more complex, less understood, samples such as polycrystalline samples or composite samples.
We have developed wavelength-Shifting-fiber Scintillator Detector (SSD) with 0.3 m2 area per module. Each module has 154 x 7 pixels and a 5 mm x 50 mm pixel size. Our goal is to design a large area neutron detector offering higher detection efficiency and higher count-rate capability for Time-Of-Flight (TOF) neutron diffraction in Spallation Neutron Source (SNS). A ZnS/6LiF scintillator combined with a novel fiber encoding scheme was used to record the neutron events. A channel read-out-card (CROC) based digital-signal processing electronics and position-determination algorithm was applied for neutron imaging. Neutron-gamma discrimination was carried out using pulse-shape discrimination (PSD). A sandwich flat-scintillator detector can have detection efficiency close to He-3 tubes (about 10 atm). A single layer flat-scintillator detector has count rate capability of 6,500 cps/cm2, which is acceptable for powder diffractometers at SNS.
Researchers have measured the phase behavior of green house gases in pores at the Angstrom-level, using small angle neutron scattering (SANS) at the Oak Ridge National Laboratory's High Flux Isotope Reactor. Yuri Melnichenko, an instrument scientist on the General Purpose Small Angle Neutron Scattering (GP SANS) Diffractometer at ORNL's High Flux Isotope Reactor, his postdoctoral associate Lilin He and collaborators Nidia Gallego and Cristian Contescu from the Material Sciences Division (ORNL) were engaged in the work. They were studying nanoporous carbons to assess their attractiveness as storage media for hydrogen, with a view to potential use for on-board hydrogen storage for transportation applications. Nanoporous carbons can also serve as electrode material for supercapacitors and batteries. The researchers successfully determined that the most efficiently condensing pore size in a carbon nanoporous material for hydrogen storage is less than one nanometer. In a paper recently published by the Journal of the American Chemical Society, the collaborators used small angle neutron scattering to study how hydrogen condenses in small pores at ambient temperature. They discovered that the surface-molecule interactions create internal pressures in pores that may exceed the external gas pressure by a factor of up to 50. 'This is an exciting result,' Melnichenko said, 'as you achieve extreme densification in pores 'for free', i.e. without spending any energy. These results can be used to guide the development of new carbon adsorbents tailored to maximize hydrogen storage capacities.' Another important factor that defines the adsorption capacity of sub-nanometer pores is their shape. In order to get accurate structural information and maximize sorption capacity, it is important that pores are small and of approximately uniform size. In collaboration with Drexel University's Yury Gogotsi who supplied the samples, Melnichenko and his collaborators used the GP SANS instrument to study how the size and shape of pores in sub-nanometer porous carbons varies, depending on the manufacturing conditions. While small angle X-ray scattering (SAXS) can do the job too, Melnichenko says, the SANS method broke new ground in analyzing the shape and behavior of pores at subnanometer size, when subjected to varying synthesis temperature. 'We found that these very small pores are in fact spherical, and that when we change the synthesis conditions, they become elongated, even 'slit-like', and all of this on a subnanometer scale,' Melnichenko said.
The combined utilization of an X-ray diffractometer and a high temperature chamber is used for the direct observation of phase transformations, changes in lattice imperfections, chemistry and the structure of the phases of a high speed steel powder. M{sub 6}C-carbides are at first suppressed for the high cooling rates during atomization and only MC-carbides are detected at room temperature. The high amount of retained austenite of the origin powder is associated with interstitially dissolved carbon. During heating-up above 710 deg. C the formation of M{sub 6}C-carbides occurs simultaneously with the transformation of austenite to a body centered cubic structure. Above 800 deg. C a significant decrease of the MC-carbides occurs; a direct transformation of the MC to M{sub 6}C-carbides was not found. The formation and dissolving of carbides occurs only in an interaction with the austenite, martensite and bainite. Therefore the carbon content of the matrix influences the nature and course of transformations. After the whole heat treatment the mixture of phases gets nearer to an equilibrium.
The Rietveld refinement has been employed for study of metastable phase of alloys U-2.5Zr-7.5Nb(wt%) and U-3Zr-9Nb(wt%). The ingots of both alloys were produced in vacuum induction furnace at temperature of about 1500 deg.C followed by cooling to room temperature. The samples with 2.5 cm in diameter and 0.3 cm of thickness was homogenized at 1000 deg.C/16 hours and treated isothermally at (i) 600 deg.C for 0.5, 3 and 24 hours and (ii) 300 deg.C for 4 minutes, 20 minutes and 17.5 hours. At the end of each treatment the samples were water quenched. Data from X-ray diffraction were collected at room temperature with a Rigaku diffractometer D Max-RAPID radiation Cuk{alpha} using steps of 0.02 deg. (2{theta}) with scan angle in the range of 20-80 deg. (2{theta}). The full diffraction pattern was analyzed by the Rietveld method using the GSAS program. The result shows that the non-resolved appearance of the XRD patterns added to the proximity of the Bragg reflections of the transition phase makes the refinement of alloys a challenging task. For the isothermal treatment at 600 deg.C during 0.5 and 3 hours both alloys showed the majority presence of {gamma}{sup S} phase fallow by {gamma}{sup 0} phase in minor amounts. For 24 hours at 600 deg.C occurred the decomposition of phases with the presence of {gamma}{sup S} + {alpha}. Isothermal treatment at 300 deg.C for both alloys is characterized by the presence of phases {gamma}{sup 0} + {alpha}'' where the concentration of the {alpha}'' phase increases with time of heat treatment. (authors)
Neutrons provide an effective tool to probe materials structure. Neutron diffraction is a method to determine the atomic and magnetic structure of a material based on neutron scattering. By this method a collimated incident beam of thermal neutrons heat the examined sample and based on the obtained diffraction pattern information on the structure of the material is provided. Research for developing a novel cold neutron detector for Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is underway at the NIST center for neutron research. The system unique design is aimed to provide over ten times fold faster analysis of materials than conventional system. In order to achieve the fast analysis a large number of neutron detectors is required. A key design constraint for this detector is the thickness of the neutron sensitive element. This is met using {sup 6}LiF:ZnS(Ag) scintillation material with embedded wavelength shifting (WLS) fibers conducting scintillation light to silicon photomultiplier photo-sensors. The detector sensitivity is determined by both the neutron capture probability ({sup 6}Li density) and the detectable light output produced by the ZnS(Ag) ionization, the latter of which is hindered by the fluorescence absorption of the scintillation light by the ZnS. Tradeoffs between the neutron capture probability, stimulated light production and light attenuation for determining the optimal stoichiometry of the {sup 6}LiF and ZnS(Ag) as well as the volume ratio of scintillator and fiber. Simulations performed using the GEANT4 Monte Carlo package were made in order to optimize the detector design. GEANT4 enables the investigation of the neutron interaction with the detector, the ionization process and the light transfer process following the nuclear process. The series of conversions required for this detector were modelled: - A cold neutron enters the sensor and is captured by {sup 6}Li in the scintillator mixture ({sup 6}Li (n,α) {sup 3}H reaction). The study of investigating the capture process probability for neutron energy of 5.1 meV to 2.27 meV (4 - 6 A) is presented. - Alpha particles and tritons travel for a few microns in the scintillation material (α ∼0.007 mm, T ∼0.04 mm) losing energy and ionizing the ZnS. The mean free path of the two particles in each of the component materials and the complete compound was investigated. - The ionization of the ZnS(Ag) scintillation material produces blue light photons with luminescence wavelength of 450 nm. The amount of light output produced for different grain sizes of ZnS is discussed. - A large portion of the scintillation photons are reabsorbed during their passage through the scintillation material. - The blue photons that reach the WLS fibers are absorbed by fluorescent dye and are re-emitted as green photons, conducted by the fiber to the SiPM photo-sensor. This work presents the CANDOR unique design and its design constrains, the results measured by the ultra-thin {sup 6}LiF:ZnS(Ag)-based neutron detector versus the simulation results for several binder concentrations. The light measurement attenuation results along with the measured stopping power were utilized to predict the sensitivity results of configuration with different ZnS grain size, weight ratios and fibers geometry (number and location). The simulations enable to optimize the final sensor design. This design successfully achieved both the high gamma rejection with a sensitive and accurate neutron event detection of 80 percent. (authors)
Neutron imaging is complementary to X-ray imaging where both are used to investigate the internal features of objects nondestructively. Historically, it only began three years after discovery of the neutron in 1932, however, neutron radiographs with reasonable quality were first made in the mid-fifties. Conventionally, the image is produced by placing the object between the neutron source and a two-dimensional position sensitive detector. The source commonly has a full energy spectrum (white beam) of thermal or cold neutrons to obtain high intensity in the sample and short exposure time. As a result, all neutron energies contribute to the obtained radiograph. Since the interaction of the neutron with matter is energy dependent, different energies produce different contrast on the radiographic image, hence, additional information about the object can be obtained. Neutron imaging that utilizes a narrow spectrum of energy instead of white beam is called energy selective neutron imaging. Many techniques have been explored to select a narrow band of neutron energy for the use in imaging such as the use velocity selectors, double crystal Monochromators, and time of flight techniques (at pulsed neutron sources). The PULSTAR reactor of North Carolina State University (1 MWth) currently has an operational neutron powder diffractometer (NPD) installed on beam tube no. 4, which was designed for neutron scattering experiments and can provide a monoenergetic beam of neutrons. The neutron energy could be selected by diffraction means using a Si bent perfect crystal as a Monochromator. In this work, an investigation of energy selective neutron imaging at the NPD is discussed in terms of the system performance and the ability of material discrimination on a test sample by observing the contrast variations of the neutron radiographs obtained using different neutron energies. Energy selective neutron imaging experiment was successfully tested at the PULSTAR reactor's NPD. Although, the uniform region is small and the exposure time is long in comparison with the NIF, both facilities exhibit similar spatial resolution which is a very important characteristic for any imaging facility. The contrast variation of neuron radiographs for the test sample obtained at different energies indicated a potential advantage for using energy selective neutron imaging over the white beam. (authors)
High temperature materials with a good resistance to oxidation or corrosion are crucial for the Generation IV nuclear system such as VHTR (Very High Temperature Reactor). While several commercial Ni-based high temperature alloys have been among the candidate ones for the IHX (intermediate heat exchanger) or HGD (hot gas duct) of VHTR, they disclose their insufficiency for the application to the anticipated outlet temperature range such as 900 deg. C or above. Unless the operating temperature is significantly lowered and the performance of the system drops in consequence, a breakthrough in the candidate materials for the key components shall be necessary for the realization of the system. Feasibility for the oxide dispersion strengthening (ODS) of Ni-based alloys was studied by fabrication of alloy 617-base ODS alloy. Alloy 617 powders were mechanically alloyed (MA) with 0.3 wt% Y{sub 2}O{sub 3} powders of around 30 nm in diameter using a horizontal ball mill (ZoZ CM 08). After degassing and canning procedure, MA powders were hot extruded. Extruded alloy samples were tensile tested at high temperatures as well as at room temperature. Also high temperature creep rupture tests were conducted at 950 deg. C in air under 20 and 25 MPa, respectively. The behavior of oxide particles within the Ni-based alloy matrix was investigated by mechanical alloying of Ni- Cr-Fe ternary alloy powders and pure Ni powders with oxide particles, respectively. Oxide such as Y{sub 2}O{sub 3}, Cr{sub 2}O{sub 3}, HfO{sub 2}, ZrO{sub 2}, TiO{sub 2}, La{sub 2}O{sub 3} were chosen from the thermodynamic point of view as the first stable candidates from more than twenty oxides, nitrides and carbides. The behavior of oxide particle within the MA powder matrix along with the temperature was characterized by using high temperature XRD (X-ray Diffractometer) and (HR)TEM (High Resolution Transmission Electron Microscope). Creep rupture tests of the ODS alloy samples at 950 deg. C showed one order of magnitude lower creep rates than those of the corresponding alloy. (authors)
The U.S. Department of Energy (DOE) has committed to provide funding to the Idaho National Laboratory (INL) for new post-irradiation examination (PIE) equipment in support of advanced fuels development. This equipment will allow researchers at the INL to accurately characterize the behavior of experimental test fuels after they are removed from an experimental reactor also located at the INL. The accurate and detailed characterization of the fuel from the reactor, when used in conjunction with computer modeling, will allow DOE to more quickly understand the behavior of the fuel and to guide further development activities consistent with the missions of the INL and DOE. Due to the highly radioactive nature of the specimen samples that will be prepared and analyzed by the PIE equipment, shielded enclosures are required. The shielded cells will be located in the existing Analytical Laboratory (AL) basement (Rooms B-50 and B-51) at the INL Material and Fuels Complex (MFC). AL Rooms B-50 and B-51 will be modified to establish an area where sample containment and shielding will be provided for the analysis of radioactive fuels and materials while providing adequate protection for personnel and the environment. The area is comprised of three separate shielded cells for PIE instrumentation. Each cell contains an atmosphere interface enclosure (AIE) for contamination containment. The shielding will provide a work area consistent with the as-low-as-reasonably-achievable (ALARA) concept, assuming a source term of 10 samples in each of the three shielded areas. Source strength is assumed to be a maximum of 3 Ci at 0.75 MeV gamma for each sample. Each instrument listed below will be installed in an individual shielded enclosure: Shielded electron probe micro-analyzer (EPMA) Focused ion beam instrument (FIB) Micro-scale x-ray diffractometer (MXRD). The project is designed and expected to be built incrementally as funds are allocated. The initial phase will be to fund the construction activities, which will include facility modifications and construction of one shielded enclosure. Follow-up activities will be to construct two additional shielded enclosures to complete the suite of three separate but connected remote operated examination areas. Equipment purchases are to be capital procurement spread out over several years on a funded schedule. This paper discusses safety and operational considerations given during the conceptual design phase of the project. The paper considers such things as project material at risk (MAR), new processes and equipment, potential hazards, and the major modification evaluation process to determine if a preliminary Documented Safety Analysis (PDSA) is required. As part of that process, an evaluation was made of the potential hazards with the new project compared to the existing and historical work and associated hazards in the affected facility.
A small addition of Li changes the orthorhombic structure of CuMg2 to hexagonal CuLixMg2-x (x = 0.08). Determining the Li content of the ternary phase and Li atomic positions was our main objective for this work. For this reason we performed neutron diffraction at several different temperatures below and above room temperature. The results obtained on two neutron powder diffractometers were compared with X-ray diffraction (XRD) data, and with first principles calculations. The first principles calculations are in good agreement with Rietveld-refined data from neutron diffraction, but do not show a marked preference for one of several possible Li sites. The Pair Distribution Function (PDF) fitting is consistent with Li substituting only Mg1 (1/2, 0, z). Interstitial spaces in the structure of CuMg2 and of CuLixMg2-x were also considered, but are unlikely to be occupied by Li. Neutron diffraction data for binary CuMg2 and Cu2Mg were also obtained.
Flux is a simple yet key indicator of overall beamline alignment. For many synchrotron measurements, the energy resolution and reproducibility are important characteristics as well. However, many beamlines do not have diffractometers capable of measuring the energy resolution in the experimental hutches. For absolute flux measurements, we have found that thickness calibrated Si photodiodes make very convenient, robust detectors capable of handling a wide flux range. For measuring the energy resolution, we have developed a simple, portable instrument analyzer applicable to any beamline with a scanning monochromator. This same instrument is capable of measuring the energy stability and reproducibility as well. We have used these to characterize many of the beamlines on the NSLS X-ray ring, and will present the methods and our experience to date to demonstrate their usefulness.
Abstract In operando powder diffraction remains one of the most powerful tools for non‐destructive investigation of battery electrode materials. While in operando X‐ray, especially synchrotron radiation, powder diffraction is by now a routine experimental technique, in operando neutron powder diffraction is still less established. We present a new electrochemical cell for in operando neutron powder diffraction, which is, first and foremost, easy to use, but can also cycle electrode materials under electrochemical conditions close to those achieved using standard laboratory cells. The cell has been designed in multiple sizes, and high‐quality electrochemical and neutron powder diffraction data is presented for sample sizes as low as 48 mg total active material. The cell handles lithium‐ion and sodium‐ion materials equally well, with no difference in how the cell is prepared and assembled. The cell is intended to be used as sample environment at powder diffractometers at the neutron facilities MLZ, ORNL and ACNS.