Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed wind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Fish Friendly Water Rules' Impact On the Power Grid with High VRE Levels

Columbia River basin multipurpose reservoirs are operated for hydropower production and many other purposes considering the aquatic habitat of the river basin. Specifically, the river basin fish population is a vital element for the tribal community of the river basin. When conventional thermal power plants are retired, hydropower flexibility balances the wind and solar variability of the power grid and provides grid services to maximize the high renewable power absorption. On the other hand, over-reliance on hydropower could harm the river basin fish habitat. For example, water release pulses during peak electricity demand hours and shorter-term water release variation could harm the fish population. Power grid planners, environmentalists, Columbia Basin tribes, hydro regulators, and water resource planners work together to understand the impacts of Columbia River basin operation in a fish-friendly way in the current power grid and power grid with higher renewable power share. We examine different levels of renewable share in the Western Interconnection to understand the multiple weather years and future climate projection and operating scenario impact on the power grid and water system. We measure power grid impacts for various water resources planning scenarios in terms of total system operating cost, system reliability indicators, changes in wind and solar generation and curtailments, local marginal prices, and revenue for hydropower producers. The study results inform reservoir operating rules decisions from hydropower power producers, system operators, other water users, tribes, environmentalists, and other stakeholders.

environmental↗

Sea spray aerosol production flux retrieval based on Doppler lidar measurements

Supermicron sea spray aerosols (SSA) play a crucial role in stratocumulus cloud microphysics and drizzle formation. However, our understanding of SSA's spatiotemporal distribution, production mechanisms, and fluxes in the marine boundary layer remains limited. This study introduces a novel approach to determine supermicron SSA production flux and number concentration at various heights above the ocean surface. Our method leverages Doppler lidar data, specifically attenuated backscatter and vertical velocity, collected at a 105 m range gate during the Eastern Pacific Clouds and Aerosols for Precipitation Experiment (EPCAPE) at Scripps Pier, La Jolla, California. To focus on nascent SSA, we analyzed data from periods with wind directions between 225° and 315° and wind speeds exceeding 4 m s −1 . Cloud and precipitation events were excluded using relative humidity, backscatter thresholds, and 2D Video Disdrometer observations. Results show that calculated supermicron SSA number concentrations at 105 m ranged from 0.26 to 2.93 cm −3 for surface wind speeds between 4 and 6 ms −1 . When exceeding the method's Limit of Detection, estimated production fluxes ranged from 0.20 to 1.53 cm −2 s −1 . This methodology has potential for application in various oceanic locations, likely enhancing our understanding of SSA's role in atmospheric processes and climate interactions.

54 ENVIRONMENTAL SCIENCES↗

Use Case Specification

Over the past three years, the Use Case Specification project has provided scenarios that have driven the development of key E-COMP capabilities and demonstrated their application to problems that the electric power industry is facing. These scenarios have provided the basis for which each Thrust has performed technical work, tying together E-COMP work under a common umbrella. Documented in this report is a summary of the background, motivations, and work – completed or proposed – under the three E-COMP use cases pursued to date: Offshore Wind, Remote Communities on the Olympic Peninsula, and Large Electric Loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient Probabilistic Visualization of Local Divergence of 2D Vector Fields with Independent Gaussian Uncertainty

This work focuses on visualizing uncertainty of local divergence of two-dimensional vector fields. Divergence is one of the fundamental attributes of fluid flows, as it can help domain scientists analyze potential positions of sources (positive divergence) and sinks (negative divergence) in the flow. However, uncertainty inherent in vector field data can lead to erroneous divergence computations, adversely impacting downstream analysis. While Monte Carlo (MC) sampling is a classical approach for estimating divergence uncertainty, it suffers from slow convergence and poor scalability with increasing data size and sample counts. Thus, we present a two-fold contribution that tackles the challenges of slow convergence and limited scalability of the MC approach. (1) We derive a closed-form approach for highly efficient and accurate uncertainty visualization of local divergence, assuming independently Gaussian-distributed vector uncertainties. (2) We further integrate our approach into Viskores, a platform-portable parallel library, to accelerate uncertainty visualization. In our results, we demonstrate significantly enhanced efficiency and accuracy of our serial analytical (speed-up up to 1946×) and parallel Viskores (speed-up up to 19698×) algorithms over the classical serial MC approach. We also demonstrate qualitative improvements of our probabilistic divergence visualizations over traditional mean-field visualization, which disregards uncertainty. We validate the accuracy and efficiency of our methods on wind forecast and ocean simulation datasets.

Ouermi, Timbwaoga [University of Utah]↗

Metal-Insulation REBCO Pancake Coil With Solder Surface Shunt: Testing and Modeling

Rare-earth barium copper oxide (REBCO) high-temperature superconducting (HTS) magnets can generate very high magnetic fields with superior engineering current density and robust mechanical integrity. The no-insulation (NI) winding technique, including its metal-insulation (MI) variant, enables “self-protection” against localized overheating through inter-turn current sharing, improving defect tolerance and allowing temporary current overloads. In REBCO pancake coils, the current-sharing path is predominantly confined to the edges of the REBCO tapes due to insulating buffer layers. Applying a surface shunt using solder can effectively enhance current sharing in NI/MI coils via the REBCO tape edges. Here, in this paper, we present both experimental and numerical research on the current distribution in surface-shunt metal-insulation (SSMI) REBCO pancake coils. We tested a stainless steel co-wound MI REBCO double-pancake coil, before and after applying a soldered surface shunt, in a saturated liquid nitrogen bath. The SSMI coil was modeled using the H-formulation and rotated anisotropic resistivity to study its dynamic behavior, including inter-turn current sharing and intra-turn screening currents. Benchmarked by experimental data, the numerical model is able to study the defect tolerance of the SSMI coil during energization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Current potential patches

A novel form of the current potential, a mathematical tool for the design of stellarators and stellarator coils, is developed. Specifically, these are current potentials with a finite-element basis, called current potential patches. Current potential patches leverage the relationship between distributions of magnetic dipoles and current potentials to explore limits of the access properties of stellarator coil sets. An example calculation is shown using the Helically Symmetric Experiment (HSX) equilibrium, demonstrating the method's use in coil design and understanding the limits of the access properties of coil sets. Current potential patches have additional desirable properties such as of promoting sparse current sheet solutions and identifying crucial locations of shaping current placement. A result is found for the HSX equilibrium that shaping currents covering only 22% of the winding surface are sufficient to produce the equilibrium to a good accuracy, provided a toroidal field is generated by an exterior coil set.

Elder, Todd↗

Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology

The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. Furthermore this has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A method for assessing economic, environmental, and reliability tradeoffs of interregional transmission connecting ERCOT (the Texas grid) to the eastern and western grids

Reliable development of the power grid is an evolving concern for humanity due to extreme weather that frequently threatens power sector infrastructure. The state of Texas is a uniquely structured testbed for grid planners to study when looking for solutions to development, innovation, and overcoming such challenges. Because of its size and islanded structure, Texas is small enough to model, but big enough to matter. Texas is a global leader in energy production, energy consumption, and maintains an unusually diverse fuel mix. In addition, the state has experienced winter freezes, heat waves, wind storms, droughts and floods that have threatened power sector infrastructure or caused recent blackouts and calls for demand side conservation. One of the most devastating of these events was the North American winter storm, dubbed “Winter Storm Uri” by the Weather Channel, that froze the region in February 2021 and led to an extended power outage event that put the majority of Texan residents in darkness for days. While preparing to avoid such outage events in the future, various tools have been proposed to improve grid reliability, including energy efficiency, demand response, and distributed energy resources. An additional option would be to develop interregional transmission that connects the Texas grid to other national grids. To assess the merits of this idea, we developed a novel, universally-applicable and internationally-relevant framework to study how the Texas grid would evolve alongside access to various interregional ties. This method allows us to stress the synthetic grid structure and analyze how it would respond to the shock of a simulated winter storm event. Our method leverages open-source modeling tools, such as PowerGenome, pyGRETA, and GenX to synthesize unique zonal grid data, construct a consolidated network of model regions, and simulate different developmental pathways of capacity expansion and operational dispatch. We demonstrate our method with an analysis connecting the Electric Reliability Council of Texas (ERCOT), the grid that serves most of Texas, the Western Electricity Coordinating Council (WECC), the grid that serves the western half of the contiguous U.S., and the Eastern Interconnect, the grid that serves the eastern half of the contiguous U.S. Our results indicate that the cost-optimal capacity of interregional transmission connecting the ERCOT grid to other grids lies between 9–13 GW assuming baseline conditions. Building this amount of connecting capacity in one or multiple directions lowers the costs and emissions of development and operation by up to $16 billion and 257 million metric tonnes (MMT) respectively. Additionally, our results show that the interregional connections between ERCOT and other national grids reduce the amount of total load shed required through mild winter storm events. However, our results also show that there is a threshold of very extreme winter storm conditions, spanning multiple service areas, above which the connections exacerbate resource adequacy problems. Therefore, the results indicate that the connections need to be carefully planned alongside the rest of the grid infrastructure to avoid over-reliance on specific resources or technology options.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deployment Potential of Concentrating Solar Power Technologies in California

As states within the United States respond to future grid development goals, there is a growing demand for reliable and resilient nighttime generation that can be addressed by low-cost, long-duration energy storage solutions. This report studies the potential of including concentrating solar power (CSP) in the technology mix to support California’s goals as defined in Senate Bill 100. A joint agency report study that determined potential pathways to achieve the renewable portfolio standard set by the bill did not include CSP, and our work provides information that could be used as a follow-up. This study uses a capacity expansion model configured to have nodal spatial fidelity in California and balancing-area fidelity in the Western Interconnection outside of California. The authors discovered that by applying current technology cost projections CSP fulfills nearly 15% of the annual load while representing just 6% of total installed capacity in 2045, replacing approximately 30 GWe of wind, solar PV, and standalone batteries compared to a scenario without CSP included. The deployment of CSP in the results is sensitive to the technology’s cost, which highlights the importance of meeting cost targets in 2030 and beyond to enable the technology’s potential contribution to California’s carbon reduction goals.

14 SOLAR ENERGY↗

Data efficiency assessment of generative adversarial networks in energy applications

This study investigates the data requirements of generative artificial intelligence (AI), particularly generative adversarial networks (GANs), for reliable data augmentation in energy applications. Generative AI, though seen as a solution to data limitations, requires substantial data to learn meaningful distributions—a challenge often overlooked. This study addresses the challenge through synthetic data generation for critical heat flux (CHF) and power grid demand, focusing on renewable and nuclear energy. Two variants of GAN employed are conditional GAN (cGAN) and Wasserstein GAN (wGAN). Our findings include the strong dependency of GAN on data size, with performance declining on smaller datasets and varying performance when generalizing to unseen experiments. Mass flux and heated length significantly influence CHF predictions. wGAN is more robust to feature exclusion, making it suitable for constrained synthetic data generation. In energy demand forecasting, wGAN performed well for solar, wind, and load predictions. Longer lookback hours and larger datasets improved predictions, especially for load power. Seasonal variations posed challenges, with wGAN achieving a relatively high error of Root Mean Squared Error (RMSE) of 0.32 for load power prediction, compared to RMSE of 0.07 under same-season conditions. Feature exclusions impacted cGAN the most, while wGAN showed greater robustness. This study concludes that, while generative AI is effective for data augmentation, it requires substantial data and careful training to generate realistic synthetic data and generalize to new experiments in engineering applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Multi-Gigawatt Electric Highway

Ultra-Compact Electrical Transmission Lines are a new transmission line technology that uses large, hollow, aluminum beams to carry current instead of thin wires. Capacity is 4.5 times higher, power losses are 3 times lower, and cost per mile is a little lower than conventional lines. Resilience and reliability are higher. The beams are enclosed within concrete walls and out of the weather, protected from high winds, ice storms, fires, and lightning. The 230 kV version is 9 feet high x 11 feet wide and can use existing rights of way next to existing transmission lines or highways. With a little landscaping, these transmission lines are not an eyesore and will be much easier to permit on existing rights of way.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large-scale Linear Magnetic Holes with Magnetic Mirror Properties in Hybrid Simulations of Solar Wind Turbulence

Magnetic holes (MHs) are coherent magnetic field dips whose size ranges from fluid to kinetic scale, ubiquitously observed in the heliosphere and in planetary environments. Despite the long-standing effort in interpreting the abundance of observations, the origin and properties of MHs are still debated. In this Letter, we investigate the interplay between plasma turbulence and MHs, using a 2D hybrid simulation initialized with solar wind parameters. We show that fully developed turbulence exhibits localized elongated magnetic depressions, whose properties are consistent with linear MHs frequently encountered in space. The observed MHs develop self-consistently from the initial magnetic field perturbations by trapping hot ions with large pitch angles. Ion trapping produces an enhanced perpendicular temperature anisotropy that makes MHs stable for hundreds of ion gyroperiods, despite the surrounding turbulence. We introduce a new quantity, based on local magnetic field and ion temperature values, to measure the efficiency of ion trapping, with potential applications to the detection of MHs in satellite measurements. We complement this method by analyzing the ion velocity distribution functions inside MHs. Our diagnostics reveal the presence of trapped gyrotropic ion populations, whose velocity distribution is consistent with a loss cone, as expected for the motion of particles inside a magnetic mirror. Our results have potential implications for the theoretical and numerical modeling of MHs.

79 ASTRONOMY AND ASTROPHYSICS↗

National serosurvey and risk mapping reveal widespread distribution of Coxiella burnetii in Kenya

Coxiella burnetii, the causative agent of Q fever, is an emerging pathogen that has the potential to cause severe chronic infections in animals and humans worldwide. The detrimental impact on public health is projected to be higher in the low- and middle-income countries given their lower capacity to sustain effective surveillance and response measures. We implemented a national serosurvey of cattle in Kenya to map the spatial distribution of the pathogen. The study used serum samples that were collected from randomly selected cattle in different ago-ecological zones across the country. These samples were screened for the pathogen using PrioCHECK Ruminant Q Fever AB Plate ELISA kit. The laboratory findings were analyzed using INLA package to identify risk factors for C. burnetii exposure from herd- and animal-level factors, area, and bioclimatic datasets accessed from online databases. A total of 6,593 cattle were recruited for the study; of these, 7.9% (95% CI; 7.2–8.5) were seropositive. Outputs from the multivariable analysis revealed that the animal age and some of the geographical variables including wind speed, area under shrubs and “petric calcisols” type of soil were significantly associated with C. burnetii seropositivity. Being a calf, weaner or subadult was associated with lower odds of exposure compared to being an adult by 0.24 (credibility interval: 2.5% and 97.5%), 0.41 (0.30–0.55) and 0.51 (0.38–0.69), respectively. In addition, a unit increase in the wind speed increased the odds of C. burnetii seropositivity by 1.27 (1.05–1.52) while an increase on the land area under shrubs was associated with lower odds of exposure (0.67 [0.47–0.69]). The effect of petric calcisols was non-linear; an increase of the land area with this soil type was associated with an exponential increase in C. burnetii seropositivity. This study provides new data on C. burnetii seroprevalence, information of its risk factors and a prevalence map that can be used for C. burnetii risk surveillance and control. The identification of environmental risk factors for C. burnetii exposure, and the increasing awareness of the zoonotic potential of the pathogen, calls for the need to enhance the existing collaborations for the surveillance and control of C. burnetii in line with the One Health framework. The evidence generated on the potential role of environmental factors can also be used to design nature-based interventions, such as replacement of vegetation in denuded areas, to reduce potential for the aerosolization of the pathogen. Livestock vaccination in the hotspots would also reduce animal infections and hence the contamination of the environment.

60 APPLIED LIFE SCIENCES↗

Stratus and Stratocumulus Cloud Microphysics and Drizzle Relationships With CCN Modality

High resolution extended-range cloud condensation nuclei (CCN) spectral comparisons with cloud microphysics and drizzle of the Physics of Stratocumulus Tops (POST) field experiment confirmed results in the Marine Stratus/Stratocumulus Experiment (MASE). Both of these stratus cloud projects demonstrated that bimodal CCN spectra typically caused by cloud processing were associated with clouds that exhibited higher concentrations of smaller droplets with narrower distributions and less drizzle than clouds associated with unimodal CCN spectra. Resulting brighter clouds and increased cloudiness could enhance both indirect aerosol effects (IAE). These stratus findings are opposite of analogous measurements in two cumulus cloud projects, which showed bimodal CCN associated with fewer larger droplets more broadly distributed and with more drizzle than clouds associated with unimodal CCN. Resulting reduced cumulus brightness and cloudiness could reduce both IAE. Physics of Stratocumulus Tops (POST) flights in air masses with higher CCN concentrations, N CCN , showed more extremes of the stratus characteristics. However, POST flights with lower N CCN showed opposite droplet characteristics similar to the cumulus clouds, yet still showed less drizzle in clouds associated with bimodal CCN, but not as much less as the flights with higher N CCN . Since all MASE clouds were in polluted air masses, while the two cumulus projects were in clean air masses we deduce from these four projects that both the dynamic stratus/cumulus differences (vertical wind) and N CCN are responsible for the microphysics and drizzle differences among these projects. This is because the clean POST characteristics are a hybrid between MASE/POST high N CCN and the two cumulus projects.

bimodality↗

Queued Up: 2025 Edition – Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2024 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with interconnection.fyi, Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 49 non-ISO balancing areas), which collectively represent ~97% of currently installed U.S. electric generating capacity. The dataset includes requests submitted to queues through the end of 2024, and only includes requests seeking to connect to the transmission grid (not distribution-connected or behind-the-meter projects). The files below include both a PDF report and an Excel data file. The PDF report analyzes interconnection data and metrics through the end of 2024. The Excel data file includes (a) the full project-level interconnection queue dataset through 2024, (b) a codebook (data dictionary) describing each data field, and (c) 35 additional tabs featuring tables summarizing a range of interconnection metrics. Key highlights from the Queued Up: 2025 Edition (featuring data through 2024) include: • As of the end of 2024, there were ~10,300 projects actively seeking grid interconnection in the U.S., representing 1,400 GW of generation and approximately 890 GW of storage. • Historic withdrawal rates alongside relatively fewer new requests resulted in a 12% decrease in total active queue volume compared to the prior year. • Active natural gas capacity (136 GW, +72% year-over-year) increased in 2024, while solar (956 GW, -12%), storage (890 GW, -13%), and wind (271 GW, -26%) capacity decreased. • 408 GW of capacity already has a draft or executed interconnection agreement (IA) but has not yet reached commercial operations. • The time projects spend in queues before reaching COD is increasing. For the regions with available data, the median duration from IR to COD has doubled from <2 years for projects built in 2000-2007 to over 4 years for those built in 2018-2024. • Ultimately, most of this proposed capacity will not be built. Only 13% of capacity that submitted interconnection requests from 2000-2019 had reached commercial operations by the end of 2024; 77% of that capacity had been withdrawn and 10% was still active. • FERC Order 2023 and various other reforms are being implemented. These are important measures to reduce interconnection bottlenecks and enhance grid system reliability, but it is too early to measure and assess their full impact. • New additions for the 2025 edition include: (a) additional detail on data processing and gaps; (b) updates on interconnection reforms; (c) new analysis on interconnection agreements, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TRACER Soil Moisture Data, Guy TX

The purpose of this study was to collect and distribute ground-truth soil water content and meteorological data in the Houston, TX, area, supporting the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility, and the 2022 field campaign for the Tracking Aerosol Convection Interactions ExpeRiment (TRACER). The files herein contain soil water content and meteorological data for the Guy, Texas station that the Bureau of Economic Geology at UT Austin installed in the area of study during period of performance. This station produces two data files. First, the file ending with “_Soil_flagged.dat” contains mean hourly volumetric soil water content and temperature measured at 5, 10, 20 and 50 cm depths. The file ending with “_Meteoro_flagged.dat” contains mean hourly measured precipitation, air temperature and humidity, wind speed and direction, and solar radiation. All data have undergone QA/QC procedures that are described by Caldwell et al. (2019) and Dorigo et al. (2013) for the soil-specific data, and EPA (2008) for the meteorological data.

precipitation↗

Uncertainty in Synthetic Tropical Cyclone Hazard and Risk Estimates: Insights from RAFT, CHAZ, MIT, STORM, and CLIMADA

We synthesize five complementary tropical cyclone (TC) hazard frameworks—RAFT (physics-based machine learning), CHAZ and MIT (statistical–dynamical), STORM (fully statistical), and CLIMADA (observation-driven resampling)—to characterize uncertainty in wind-related TC metrics relevant to energy applications. All datasets and the IBTrACS observational record are harmonized to a common 6-hourly, 2.5° grid. We compare basin-wide and coastal properties using consistent definitions for TC frequency, mean and maximum intensity, 24-hour intensification, and 6-hour translation speed, and quantify agreement with Pearson r, RMSE, and Kling–Gupta efficiency (KGE) alongside resampling-based confidence intervals. CLIMADA is included for basin context but excluded from coastal skill scoring because it resamples historical IBTrACS; if supplied with projected future tracks from an external hazard model, CLIMADA can be used to simulate future TC scenarios. Results show robust, cross-model signals: (i) a corridor of activity from the tropical Atlantic through the Caribbean into the Bahamas and western subtropical Atlantic; (ii) a meridional dipole in 24-hour intensification (low-latitude strengthening, subtropical weakening); and (iii) a transition from slower tropical motion to faster midlatitude translation. Coastal winds (mean and maximum) consistently cluster from the eastern Gulf into the Bahamas–western Atlantic transition. The largest structural spread occurs in the amplitude and footprint of lifetime maximum intensity and, secondarily, in translation speed; intensification exhibits similar central behavior across frameworks with variability in extremes. Translation speed shows the most uniform coastal agreement. These findings provide a decision envelope for wind-focused risk screening and clarify where uncertainty should be carried forward; wind-only results represent a lower bound on total hazard, motivating integration of surge and rainfall modules and a companion, asset-level damage analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗