Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distribution Islanding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Multi-Agency Annual Southeastern Beach Mouse Habitat Occupancy Monitoring

The southeastern beach mouse (Peromyscus polionotus niveiventris, hereafter SEBM), a federally threatened species was identified by Merritt Island National Wildlife Refuge (MINWR) as one of the top five priorities for management. The Kennedy Space Center (KSC) Environmental Management Branch was asked to provide support in the form of population monitoring for SEBM on KSC and the surrounding properties. When we began the project, the SEBM was known to occupy sites ranging from Volusia through Brevard and Indian River Counties, but the exact distribution within the Federal lands encompassing the Cape Canaveral Barrier Island Complex (CCBIC) was not well known. The broad range of habitat conditions encompassing the species’ historical range and the diversity of sites historically known to contain SEBM required a landscape-scale approach for both monitoring the population and for investigating species habitat relationships. We designed a monitoring plan for the SEBM with the goal of estimating the habitat occupancy of beach mice annually each winter/spring throughout the entire area of suitable coastal habitat (approximately 72 km linear distance along the beach). Methods were tested in a 2008 pilot study, and during 2010-2018 we monitored the proportion of coastal habitat occupied by the SEBM on the CCBIC. Monitoring was focused on using dynamic habitat occupancy surveys with data collected with rapid assessment techniques (i.e., track tubes or live-traps) to detect SEBM occurrence at sampling stations. An important component of the study design was the use of repeated samples that provided the information needed to estimate detectability. Measuring detectability was required to account for the fact that surveys could fail to detect animals at sites at which they were actually present (Mackenzie et al., 2002). This monitoring framework is very flexible, allowing numerous hypothesis to be tested about how various factors influence beach mouse occupancy using habitat, geographic, and environmental covariates. Our survey has been the longest survey conducted for any of the seven extant beach mouse subspecies and has encompassed nearly the entire remaining range of the SEBM. Although occupancy surveys of other beach mouse subspecies via track tubes have been conducted on the Gulf coast of Florida by Florida Fish and Wildlife Conservation Commission (FWC), United States Fish and Wildlife Service (USFWS), and various universities, we expanded previous methods to fit unique aspects of the SEBM, and thus our study was very different from any of the previous studies. To achieve this specificity, we employed an adaptive approach throughout the study, with all activities aimed at providing managers with information related to environmental compliance and natural resource management on KSC and the surrounding Federal lands.

Eric Douglas Stolen↗

Particle Acceleration and Fractional Transport in Turbulent Reconnection

We consider a large-scale environment of turbulent reconnection that is fragmented into a number of randomly distributed unstable current sheets (UCSs), and we statistically analyze the acceleration of particles within this environment. We address two important cases of acceleration mechanisms when particles interact with the UCS: (a) electric field acceleration and (b) acceleration by reflection at contracting islands. Electrons and ions are accelerated very efficiently, attaining an energy distribution of power-law shape with an index 1–2, depending on the acceleration mechanism. The transport coefficients in energy space are estimated from test-particle simulation data, and we show that the classical Fokker–Planck (FP) equation fails to reproduce the simulation results when the transport coefficients are inserted into it and it is solved numerically. The cause for this failure is that the particles perform Levy flights in energy space, while the distributions of the energy increments exhibit power-law tails. We then use the fractional transport equation (FTE) derived by Isliker et al., whose parameters and the order of the fractional derivatives are inferred from the simulation data, and solving the FTE numerically, we show that the FTE successfully reproduces the kinetic energy distribution of the test particles. We discuss in detail the analysis of the simulation data and the criteria that allow one to judge the appropriateness of either an FTE or a classical FP equation as a transport model.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy supply time in an islanded grid portion re-energized by local renewable sources

When a portion of the low-voltage distribution network, typically a village, is disconnected from the upstream network, due to a fault or maintenance, it can be re-energized temporarily by the distribution system operator. Usually, if closing of a normally open tie-switch connected to a neighboring feeder is not possible, a diesel generator is conveyed to the islanded grid portion and used towards temporary energy supply. This solution though can be costly, environmentally detrimental or n

Marchand, Jane [University Grenoble Alpes]↗

Diffusive shock acceleration and reconnection acceleration processes

Shock waves, as shown by simulations and observations, can generate high levels of downstream vortical turbulence, including magnetic islands. We consider a combination of diffusive shock acceleration (DSA) and downstream magnetic-island-reconnection-related processes as an energization mechanism for charged particles. Observations of electron and ion distributions downstream of interplanetary shocks and the heliospheric termination shock (HTS) are frequently inconsistent with the predictions of classical DSA. We utilize a recently developed transport theory for charged particles propagating diffusively in a turbulent region filled with contracting and reconnecting plasmoids and small-scale current sheets. Particle energization associated with the anti-reconnection electric field, a consequence of magnetic island merging, and magnetic island contraction, are considered. For the former only, we find that (i) the spectrum is a hard power law in particle speed, and (ii) the downstream solution is constant. For downstream plasmoid contraction only, (i) the accelerated spectrum is a hard power law in particle speed; (ii) the particle intensity for a given energy peaks downstream of the shock, and the distance to the peak location increases with increasing particle energy, and (iii) the particle intensity amplification for a particular particle energy, f(x,c/c{sub 0})/f(0,c/c{sub 0}), is not 1, as predicted by DSA, but increases with increasing particle energy. The general solution combines both the reconnection-induced electric field and plasmoid contraction. The observed energetic particle intensity profile observed by Voyager 2 downstream of the HTS appears to support a particle acceleration mechanism that combines both DSA and magnetic-island-reconnection-related processes.

79 ASTRONOMY AND ASTROPHYSICS↗

Decentralized Energy Management System for Networked Microgrids in Grid-connected and Islanded Modes

This paper proposes a decentralized energy management system (EMS) for the coordinated operation of networked Microgirds (MGs) in a distribution system. In the grid-connected mode, the distribution network operator (DNO) and each MG are considered as distinct entities with individual objectives to minimize their own operation costs. It is assumed that both dispatchable and renewable energy source (RES)-based distributed generators (DGs) exist in the distribution network and the networked MGs. In order to coordinate the operation of all entities, we apply a decentralized bi-level algorithm to solve the problem with the first level to conduct negotiations among all entities and the second level to update the non-converging penalties. In the islanded mode, the objective of each MG is to maintain a reliable power supply to its customers. In order to take into account the uncertainties of DG outputs and load consumption, we formulate the problems as two-stage stochastic programs. The first stage is to determine base generation setpoints based on the forecasts and the second stage is to adjust the generation outputs based on the realized scenarios. Case studies of a distribution system with networked MGs demonstrate the effectiveness of the proposed methodology in both grid-connected and islanded modes.

Distributed Generator (DG)↗

Atomic assembly during ion-beam assisted growth: Kinetic modeling

The influence of an additional bombardment with low-energy ions during conventional molecular beam epitaxy deposition is studied. A model is proposed describing the initial growth stages during conventional molecular beam epitaxy and ion-beam assisted molecular beam epitaxy. The additional bombardment with low-energy ions leads to a transformation of the growth mode from island growth to layer-by-layer growth. In the first stages of film growth, the hyperthermal ion bombardment causes an increasing detachment of atoms from the tops of the growing islands. Based on the model, using simulation by the kinetic-equation method, the size distribution function of growing clusters is calculated. The theoretical results are in good agreement with experimental results obtained upon the deposition of GaN films.

36 MATERIALS SCIENCE↗

Robust Scheduling of Microgrids Considering Unintentional Islanding Conditions

This paper proposes a robust scheduling model for microgrids considering the stochastic unintentional islanding conditions. The proposed model minimizes the total operating cost of the microgrid by efficiently coordinating the supply of power from local distributed energy resources and the main grid. To capture the prevailing uncertainties in renewable generation and demand as well as unintentional islanding conditions, a two-stage adaptive robust optimization model is formulated to minimize the total operating cost under the worst realization of the modeled uncertainties. The column and constraint generation (C&CG) method is used to solve the problem in an iterative manner. The solution of the proposed scheduling model ensures robust microgrid operation in consideration of all possible realization of renewable generation, demand and unintentional islanding condition. Numerical simulations on a microgrid consisting of a wind turbine, a PV panel, a fuel cell, two micro-turbines, a diesel generator and a battery demonstrate the effectiveness of the proposed approach.

Liu, Guodong↗

2017 Distributed Wind Market Report

The U.S. Department of Energy’s (DOE’s) annual Distributed Wind Market Report provides stakeholders with market statistics and analysis along with insights into its trends and characteristics. Cumulative U.S. distributed wind installed capacity for 2003 to 2017 now stands at 1,076 MW from over 81,000 wind turbines across all 50 states, Puerto Rico, the U.S. Virgin Islands (USVI), and Guam. In 2017, 21 states added 83.7 MW of new distributed wind capacity, representing 3,311 units and $274 million in investment. By providing a comprehensive overview of the distributed wind market, this report can help guide future investments and decisions by industry, utilities, federal and state agencies, and other interested parties.

17 WIND ENERGY↗

Optical design study of an infrared visible viewing system for Wendelstein 7-X divertor observation and control

For the Wendelstein 7-X stellarator, which will allow quasicontinuous operation ({tau}{<=}30 min) with 10 MW of electron cyclotron radiation heating power, a conceptual design study for an IR/visible viewing system (IVVS) has been elaborated. Ten such systems, as part of the machine protection system, will be required for real time monitoring of all ten discrete, water cooled divertor modules with high spatial (<10 mm) resolution, in order to prevent local overheating of the target tiles, which could easily lead to their destruction. On the physics side, the systems will be used for divertor symmetry investigations by studying the power load distribution on all targets modules and by observing the island divertor plasmas in the light of H{alpha}, C II, and C III using the visible imaging section of the systems. The optics of the system can be divided into three parts: a mirror based optical head, creating an intermediate image, a Cassegrain telescope system, and individual lens based imaging optics adapted to the various detectors for IR (3-5 {mu}m and 8-14 {mu}m) and visible observations, with their optical light paths being separated by in-vacuum dichroic beam splitters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shaping the composition profiles in heteroepitaxial quantum dots: Interplay of thermodynamic and kinetic effects

Atomistic Monte Carlo simulations, coupling thermodynamic and kinetic effects, resolve a longstanding controversy regarding the origin of composition profiles in heteroepitaxial SiGe quantum dots. It is shown that profiles with cores rich in the unstrained (Si) component derive from near-equilibrium processes and intraisland diffusion. Profiles with cores rich in the strained (Ge) component are of nonequilibrium nature, i.e., they are strain driven but kinetically limited. They are shaped by the distribution of kinetic barriers of atomic diffusion in the islands. The diffusion pathways are clearly revealed for the first time. Geometrical kinetics play a minor role.

36 MATERIALS SCIENCE↗

Test-Based Modeling of Photovoltaic Inverter Impact on Distribution Systems

Distributed PV has important effects on overcurrent, overvoltage and islanding protection. These effects are more difficult to analyze because the faulted behavior of PV inverters is less well understood than for rotating machines. Full transient models of the inverter can be accurate, but that approach requires inverter design details and simulation software that doesn’t easily interoperate with utility protection system software. Further, anomalous model behaviors often emerge at different grid conditions, and these are difficult to fix in a proprietary model. Testing provides another approach to characterize inverters, validate models or answer questions of application. This earlier work found major impacts from the inverter design, firmware, operating point and balance-of-system components. Our objective is to characterize PV inverters from black-box testing, leading to standard test reports that could provide parameter sets for widely-implemented models in software tools. The tool vendors can then develop standard inverter models, as they did for rotating machines and exciters. Besides fully detailed transient models, inverters can be represented with steady-state current sources, dynamically controlled current sources or non-linear frequency-dependent black boxes. Type-test data could support the last three kinds of model. Short circuit and sag tests would encompass the basic fault types, reporting the maximum transient and rms currents over all power levels and points-on-wave within four time ranges : 1) 0 to 1 cycles, for close and latch consideration 2) 1 to 4 cycles, for equipment withstand 3) 4 to 30 cycles, for interrupt ratings 4) 30 cycles and beyond, for backup protection analysis Open circuit tests would vary output power and power factor, and report the maximum rms voltage from 1 to 10 cycles after the event. Without models, the type-test data could also provide upper limits on the expected overvoltages and overcurrents.

Wieserman, Laura M.↗

Three-Phase Unbalanced Transient Dynamics and Powerflow for Modeling Distribution Systems With Synchronous Machines

Unlike transmission systems, distribution feeders in North America operate under unbalanced conditions at all times, and generally have a single strong voltage source. When a distribution feeder is connected to a strong substation source, the system is dynamically very stable, even for large transients. However if a distribution feeder, or part of the feeder, is separated from the substation and begins to operate as an islanded microgrid, transient dynamics become more of an issue. To assess the impact of transient dynamics at the distribution level, it is not appropriate to use traditional transmission solvers, which generally assume transposed lines and balanced loads. Full electromagnetic solvers capture a high level of detail, but it is difficult to model large systems because of the required detail. This paper proposes an electromechanical transient model of synchronous machine for distribution-level modeling and microgrids. This approach includes not only the machine model, but also its interface with an unbalanced network solver, and a powerflow method to solve unbalanced conditions without a strong reference bus. The presented method is validated against a full electromagnetic transient simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Raindrop Size Distribution Measurements in Tropical Cyclones

Characteristics of the raindrop size distribution in seven tropical cyclones have been studied through impact-type disdrometer measurements at three different sites during the 2004-06 Atlantic hurricane seasons. One of the cyclones has been observed at two different sites. High concentrations of small and/or midsize drops were observed in the presence or absence of large drops. Even in the presence of large drops, the maximum drop diameter rarely exceeded 4 mm. These characteristics of raindrop size distribution were observed in all stages of tropical cyclones, unless the storm was in the extratropical stage where the tropical cyclone and a midlatitude frontal system had merged. The presence of relatively high concentrations of large drops in extratropical cyclones resembled the size distribution in continental thunderstorms. The integral rain parameters of drop concentration, liquid water content, and rain rate at fixed reflectivity were therefore lower in extratropical cyclones than in tropical cyclones. In tropical cyclones, at a disdrometercalculated reflectivity of 40 dBZ, the number concentration was 700 plus or minus 100 drops m(sup -3), while the liquid water content and rain rate were 0.90 plus or minus 0.05 g m(sup -3) and 18.5 plus or minus 0.5 mm h(sup -1), respectively. The mean mass diameter, on the other hand, was 1.67 plus or minus 0.3 mm. The comparison of raindrop size distributions between Atlantic tropical cyclones and storms that occurred in the central tropical Pacific island of Roi-Namur revealed that the number density is slightly shifted toward smaller drops, resulting in higher-integral rain parameters and lower mean mass and maximum drop diameters at the latter site. Considering parameterization of the raindrop size distribution in tropical cyclones, characteristics of the normalized gamma distribution parameters were examined with respect to reflectivity. The mean mass diameter increased rapidly with reflectivity, while the normalized intercept parameter had an increasing trend with reflectivity. The shape parameter, on the other hand, decreased in a reflectivity range from 10 to 20 dBZ and remained steady at higher reflectivities. Considering the repeatability of the characteristics of the raindrop size distribution, a second impact disdrometer that was located 5.3 km away from the primary site in Wallops Island, Virginia, had similar size spectra in selected tropical cyclones.

Tokay, Ali↗

Controlled Islanding Strategy Considering Uncertainty of Renewable Energy Sources Based on Chance-constrained Model

Controlled islanding plays an essential role in preventing the blackout of power systems. Although there are several studies on this topic in the past, not enough attention is paid to the uncertainty brought by renewable energy sources (RESs) that may cause unpredictable unbalanced power and the observability of power systems after islanding that is essential for back-up black-start measures. Therefore, a novel controlled islanding model based on mixed-integer second-order cone and chance-constrained programming (MISOCCP) is proposed to address these issues. First, the uncertainty of RESs is characterized by their possibility distribution models with chance constraints, and the requirements, e. g., system observ-ability, for rapid back-up black-start measures are also considered. Then, a law of large numbers (LLN) based method is employed for converting the chance constraints into deterministic ones and reformulating the non-convex model into convex one. Finally, case studies on the revised IEEE 39-bus and 118-bus power systems as well as the comparisons among different models are given to demonstrate the effectiveness of the proposed model. The results show that the proposed model can result in less unbalanced power and better observability after islanding compared with other models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic Microgrid Scheduling With Chance‐Constrained Resilience Consideration

Traditionally, it is assumed that microgrids transition seamlessly from grid‐connected operation to islanded mode in the event of sudden main grid outages. In reality, the islanding process, especially unintentional islanding, is rarely seamless. Instead, it is subject to voltage and frequency fluctuations caused by the instantaneous disconnection of the point of common coupling (PCC) switch, variations in loads and renewable generation output and even the protection tripping of distributed energy resources (DERs). To mitigate these fluctuations and facilitate a smooth islanding process, we propose a stochastic microgrid scheduling model that incorporates chance‐constrained resilience measures. Specifically, the resilience measure is defined as the probability of successful islanding (PSI), that is, the probability that a microgrid can mitigate the generation‐demand imbalance caused by the disconnection of the PCC switch, variations in load and renewable generation and DER tripping. This measure is modelled using chance constraints. Unlike existing reliability and resilience indices, which typically neglect the possibility of microgrid/DER failure under extreme events and assume their survival while primarily focussing on reducing impact duration or magnitude, the proposed PSI‐based framework explicitly addresses microgrid and DER survival during the islanding transition. The formulated nonlinear chance constraints are approximated using a multiinterval approach and equivalently represented as a mixed‐integer linear programming (MILP) formulation. Case study results validate the proposed method, showing that the PSI estimation error is reduced to less than 8%, compared to approximately 28% with existing methods. Various sensitivity analyses on the DER tripping rate and PSI settings were performed to validate the robustness of the proposed method. In particular, the necessity of accounting for DER tripping in the PSI calculation was demonstrated.

chance constrained optimization↗

Relative Roles of Low‐Level Wind Speed and Moisture in the Diurnal Cycle of Rainfall Over a Tropical Island Under Monsoonal Flows

Abstract Using satellite observations and reanalysis data, this study investigates the relative roles of low‐level wind speed and moisture content in the rainfall diurnal cycle over a tropical island influenced by monsoonal winds. Results show that the spatiotemporal characteristics of rainfall over the island are evidently influenced by the two factors. Specifically, the spatial distribution of rainfall is primarily determined by the low‐level wind speeds, while the rainfall diurnal cycle is influenced by both factors. Weaker low‐level wind speed leads to stronger and wider inland convergence and afternoon precipitation, which are mainly produced by the inland penetrating sea breeze fronts. Nighttime rainfall over the island is closely related to the inertial oscillation. Stronger nocturnal rainfall can be found with higher low‐level moisture content and stronger monsoonal winds. The multiscale interactions between the large‐scale circulation, land–sea breezes, and inertial oscillation play essential roles in modulating the rainfall over this tropical island.

Zhu, Lei↗

Geometry optimization for micro-pressure sensor considering dynamic interference

Presented is the geometry optimization for piezoresistive absolute micro-pressure sensor. A figure of merit called the performance factor (PF) is defined as a quantitative index to describe the comprehensive performances of a sensor including sensitivity, resonant frequency, and acceleration interference. Three geometries are proposed through introducing islands and sensitive beams into typical flat diaphragm. The stress distributions of sensitive elements are analyzed by finite element method. Multivariate fittings based on ANSYS simulation results are performed to establish the equations about surface stress, deflection, and resonant frequency. Optimization by MATLAB is carried out to determine the dimensions of the geometries. Convex corner undercutting is evaluated. Each PF of the three geometries with the determined dimensions is calculated and compared. Silicon bulk micromachining is utilized to fabricate the prototypes of the sensors. The outputs of the sensors under both static and dynamic conditions are tested. Experimental results demonstrate the rationality of the defined performance factor and reveal that the geometry with quad islands presents the highest PF of 210.947 Hz{sup 1/4}. The favorable overall performances enable the sensor more suitable for altimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

De-Energized Line Testing Interface (DELTI) Report

To guarantee the safety of power system operations, it is crucial to understand a de-energized power line’s status before restoring power. It is hypothesized that the Grid Resonance Probe (GRP) and De-Energized Line Testing Interface (DELTI) can be utilized to identify a faulted distribution line. Therefore, the project team is targeting development of a methodology to identify faulted distribution lines by using the DELTI system. In this R&D task, two field tests on Plum Island have been conducted, including DELTI tests with multiple configurations and fault scenarios. This report provides the analysis results of distribution line fault identification from the two field tests. In the remainder of this report, Section 1 is the introduction of the DELTI system, Section 2 provides the analyses of the two field tests in June and October of 2021, respectively, Section 3 discusses the existing line fault detection devices on market and how they compare to DELTI and Section 4 includes the lessons learned and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗