Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Ultra-high-dose-rate FLASH and Conventional-Dose-Rate Irradiation Differentially Affect Human Acute Lymphoblastic Leukemia and Normal Hematopoiesis

Ultra-high-dose-rate FLASH radiation therapy has been shown to minimize side effects of irradiation in various organs while keeping antitumor efficacy. This property, called the FLASH effect, has caused enthusiasm in the radiation oncology community because it opens opportunities for safe dose escalation and improved radiation therapy outcome. Here, we investigated the impact of ultra-high-dose-rate FLASH versus conventional-dose-rate (CONV) total body irradiation (TBI) on humanized models of T-cell acute lymphoblastic leukemia (T-ALL) and normal human hematopoiesis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose discrepancies in the buildup region and their impact on dose calculations for IMRT fields

Purpose: Dose accuracy in the buildup region for radiotherapy treatment planning suffers from challenges in both measurement and calculation. This study investigates the dosimetry in the buildup region at normal and oblique incidences for open and IMRT fields and assesses the quality of the treatment planning calculations. Methods: This study was divided into three parts. First, percent depth doses and profiles (for 5x5, 10x10, 20x20, and 30x30 cm{sup 2} field sizes at 0 deg., 45 deg., and 70 deg. incidences) were measured in the buildup region in Solid Water using an Attix parallel plate chamber and Kodak XV film, respectively. Second, the parameters in the empirical contamination (EC) term of the convolution/superposition (CVSP) calculation algorithm were fitted based on open field measurements. Finally, seven segmental head-and-neck IMRT fields were measured on a flat phantom geometry and compared to calculations using {gamma} and dose-gradient compensation (C) indices to evaluate the impact of residual discrepancies and to assess the adequacy of the contamination term for IMRT fields. Results: Local deviations between measurements and calculations for open fields were within 1% and 4% in the buildup region for normal and oblique incidences, respectively. The C index with 5%/1 mm criteria for IMRT fields ranged from 89% to 99% and from 96% to 98% at 2 mm and 10 cm depths, respectively. The quality of agreement in the buildup region for open and IMRT fields is comparable to that in nonbuildup regions. Conclusions: The added EC term in CVSP was determined to be adequate for both open and IMRT fields. Due to the dependence of calculation accuracy on (1) EC modeling, (2) internal convolution and density grid sizes, (3) implementation details in the algorithm, and (4) the accuracy of measurements used for treatment planning system commissioning, the authors recommend an evaluation of the accuracy of near-surface dose calculations as a part of treatment planning commissioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A framework to measure myocardial extracellular volume fraction using dual-phase low dose CT images

Purpose: Myocardial extracellular volume fraction (ECVF) is a surrogate imaging biomarker of diffuse myocardial fibrosis, a hallmark of pathologic ventricular remodeling. Low dose cardiac CT is emerging as a promising modality to detect diffuse interstitial myocardial fibrosis due to its fast acquisition and low radiation; however, the insufficient contrast in the low dose CT images poses great challenge to measure ECVF from the image. Methods: To deal with this difficulty, the authors present a complete ECVF measurement framework including a point-guided myocardial modeling, a deformable model-based myocardium segmentation, nonrigid registration of pre- and post-CT, and ECVF calculation. Results: The proposed method was evaluated on 20 patients by two observers. Compared to the manually delineated reference segmentations, the accuracy of our segmentation in terms of true positive volume fraction (TPVF), false positive volume fraction (FPVF), and average surface distance (ASD), were 92.18% ± 3.52%, 0.31% ± 0.10%, 0.69 ± 0.14 mm, respectively. The interobserver variability measured by concordance correlation coefficient regarding TPVF, FPVF, and ASD were 0.95, 0.90, 0.94, respectively, demonstrating excellent agreement. Bland-Altman method showed 95% limits of agreement between ECVF at CT and ECVF at MR. Conclusions: The proposed framework demonstrates its efficiency, accuracy, and noninvasiveness in ECVF measurement and dramatically advances the ECVF at cardiac CT toward its clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Medical imaging using ionizing radiation: Optimization of dose and image quality in fluoroscopy

The 2012 Summer School of the American Association of Physicists in Medicine (AAPM) focused on optimization of the use of ionizing radiation in medical imaging. Day 2 of the Summer School was devoted to fluoroscopy and interventional radiology and featured seven lectures. These lectures have been distilled into a single review paper covering equipment specification and siting, equipment acceptance testing and quality control, fluoroscope configuration, radiation effects, dose estimation and measurement, and principles of flat panel computed tomography. This review focuses on modern fluoroscopic equipment and is comprised in large part of information not found in textbooks on the subject. While this review does discuss technical aspects of modern fluoroscopic equipment, it focuses mainly on the clinical use and support of such equipment, from initial installation through estimation of patient dose and management of radiation effects. This review will be of interest to those learning about fluoroscopy, to those wishing to update their knowledge of modern fluoroscopic equipment, to those wishing to deepen their knowledge of particular topics, such as flat panel computed tomography, and to those who support fluoroscopic equipment in the clinic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-Institution Prospective Trial of Reduced-Dose Craniospinal Irradiation (23.4 Gy) Followed by Conformal Posterior Fossa (36 Gy) and Primary Site Irradiation (55.8 Gy) and Dose-Intensive Chemotherapy for Average-Risk Medulloblastoma

Purpose: Limiting the neurocognitive sequelae of radiotherapy (RT) has been an objective in the treatment of medulloblastoma. Conformal RT to less than the entire posterior fossa (PF) after craniospinal irradiation might reduce neurocognitive sequelae and requires evaluation. Methods and Materials: Between October 1996 and August 2003, 86 patients, 3-21 years of age, with newly diagnosed, average-risk medulloblastoma were treated in a prospective, institutional review board-approved, multi-institution trial of risk-adapted RT and dose-intensive chemotherapy. RT began within 28 days of definitive surgery and consisted of craniospinal irradiation (23.4 Gy), conformal PF RT (36.0 Gy), and primary site RT (55.8 Gy). The planning target volume for the primary site included the postoperative tumor bed surrounded by an anatomically confined margin of 2 cm that was then expanded with a geometric margin of 0.3-0.5 cm. Chemotherapy was initiated 6 weeks after RT and included four cycles of high-dose cyclophosphamide, cisplatin, and vincristine. Results: At a median follow-up of 61.2 months (range, 5.2-115.0 months), the estimated 5-year event-free survival and cumulative incidence of PF failure rate was 83.0% {+-} 5.3% and 4.9% {+-} 2.4% ({+-} standard error), respectively. The targeting guidelines used in this study resulted in a mean reduction of 13% in the volume of the PF receiving doses >55 Gy compared with conventionally planned RT. The reductions in the dose to the temporal lobes, cochleae, and hypothalamus were statistically significant. Conclusion: This prospective trial has demonstrated that irradiation of less than the entire PF after 23.4 Gy craniospinal irradiation for average-risk medulloblastoma results in disease control comparable to that after treatment of the entire PF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Generalized Equivalent Uniform Dose Atlases to Combine and Analyze Prospective Dosimetric and Radiation Pneumonitis Data From 2 Non-Small Cell Lung Cancer Dose Escalation Protocols

Purpose: To demonstrate the use of generalized equivalent uniform dose (gEUD) atlas for data pooling in radiation pneumonitis (RP) modeling, to determine the dependence of RP on gEUD, to study the consistency between data sets, and to verify the increased statistical power of the combination. Methods and Materials: Patients enrolled in prospective phase I/II dose escalation studies of radiation therapy of non-small cell lung cancer at Memorial Sloan-Kettering Cancer Center (MSKCC) (78 pts) and the Netherlands Cancer Institute (NKI) (86 pts) were included; 10 (13%) and 14 (17%) experienced RP requiring steroids (RPS) within 6 months after treatment. gEUD was calculated from dose-volume histograms. Atlases for each data set were created using 1-Gy steps from exact gEUDs and RPS data. The Lyman-Kutcher-Burman model was fit to the atlas and exact gEUD data. Heterogeneity and inconsistency statistics for the fitted parameters were computed. gEUD maps of the probability of RPS rate {>=}20% were plotted. Results: The 2 data sets were homogeneous and consistent. The best fit values of the volume effect parameter a were small, with upper 95% confidence limit around 1.0 in the joint data. The likelihood profiles around the best fit a values were flat in all cases, making determination of the best fit a weak. All confidence intervals (CIs) were narrower in the joint than in the individual data sets. The minimum P value for correlations of gEUD with RPS in the joint data was .002, compared with P=.01 and .05 for MSKCC and NKI data sets, respectively. gEUD maps showed that at small a, RPS risk increases with gEUD. Conclusions: The atlas can be used to combine gEUD and RPS information from different institutions and model gEUD dependence of RPS. RPS has a large volume effect with the mean dose model barely included in the 95% CI. Data pooling increased statistical power.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Moderate Hypofractionated Protracted Radiation Therapy and Dose Escalation for Prostate Cancer: Do Dose and Overall Treatment Time Matter?

Purpose: This was a retrospective study of 2 sequential dose escalation regimens of twice-weekly 4 Gy/fractions hypofractionated intensity modulated radiation therapy (IMRT): 56 Gy and 60 Gy delivered within a protracted overall treatment time (OTT) of 6.5 and 7 weeks, respectively. Methods and Materials: 163 prostate cancer patients with cT1c-T3a disease and nodal involvement risk ≤20% (Roach index) were treated twice weekly to the prostate ± seminal vesicles with 2 sequential dose-escalated IMRT schedules: 56 Gy (14 × 4 Gy, n=81) from 2003 to 2007 and 60 Gy (15 × 4 Gy, n=82) from 2006 to 2010. Patient repositioning was made with bone matching on portal images. Gastrointestinal (GI) and genitourinary (GU) toxicities were scored according to the Common Terminology Criteria for Adverse Events version 3.0 grading scale. Results: There were no significant differences regarding the acute GU and GI toxicities in the 2 dose groups. The median follow-up times were 80.2 months (range, 4.5-121 months) and 56.5 months (range, 1.4-91.2 months) for patients treated to 56 and 60 Gy, respectively. The 5-year grade ≥2 late GU toxicity-free survivals with 56 Gy and 60 Gy were 96 ± 2.3% and 78.2 ± 5.1% (P=.001), respectively. The 5-year grade ≥2 late GI toxicity-free survivals with 56 Gy and 60 Gy were 98.6 ± 1.3% and 85.1 ± 4.5% (P=.005), respectively. Patients treated with 56 Gy showed a 5-year biochemical progression-free survival (bPFS) of 80.8 ± 4.7%, worse than patients treated with 60 Gy (93.2 ± 3.9%, P=.007). A trend for a better 5-year distant metastasis-free survival was observed among patients treated in the high-dose group (95.3 ± 2.7% vs 100%, P=.073, respectively). On multivariate analysis, only the 60-Gy group predicted for a better bPFS (P=.016, hazard ratio = 4.58). Conclusions: A single 4-Gy additional fraction in patients treated with a hypofractionated protracted IMRT schedule of 14 × 4 Gy resulted in a similar and minimal acute toxicity, in worse moderate to severe urinary and GI late effects, but a significantly better biochemical control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Fractionation During Puberty Is More Detrimental to Mammary Gland Development Than an Equivalent Acute Dose of Radiation Exposure

Computed tomographic (CT) scans in adolescents have increased dramatically in recent years. However, the effects of cumulative low-dose exposures on the development of radiation sensitive organs, such as the mammary gland, is unknown. The purpose of this work was to define the effects of dose rate on mammary organ formation during puberty, an especially sensitive window in mammary development. We used a fractionated low-dose x-ray exposure to mimic multiple higher dose CT scans, and we hypothesized that fractionated exposure would have less of an effect on the number of mammary gland defects compared with an acute exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose calculation software for helical tomotherapy, utilizing patient CT data to calculate an independent three-dimensional dose cube

Purpose: Treatment plans for the TomoTherapy unit are produced with a planning system that is integral to the unit. The authors have produced an independent dose calculation system, to enable plans to be recalculated in three dimensions, using the patient's CT data. Methods: Software has been written using MATLAB. The DICOM-RT plan object is used to determine the treatment parameters used, including the treatment sinogram. Each projection of the sinogram is segmented and used to calculate dose at multiple calculation points in a three-dimensional grid using tables of measured beam data. A fast ray-trace algorithm is used to determine effective depth for each projection angle at each calculation point. Calculations were performed on a standard desktop personal computer, with a 2.6 GHz Pentium, running Windows XP. Results: The time to perform a calculation, for 3375 points averaged 1 min 23 s for prostate plans and 3 min 40 s for head and neck plans. The mean dose within the 50% isodose was calculated and compared with the predictions of the TomoTherapy planning system. When the modified CT (which includes the TomoTherapy couch) was used, the mean difference for ten prostate patients, was -0.4% (range -0.9% to +0.3%). With the original CT (which included the CT couch), the mean difference was -1.0% (range -1.7% to 0.0%). The number of points agreeing with a gamma 3%/3 mm averaged 99.2% with the modified CT, 96.3% with the original CT. For ten head and neck patients, for the modified and original CT, respectively, the mean difference was +1.1% (range -0.4% to +3.1%) and 1.1% (range -0.4% to +3.0%) with 94.4% and 95.4% passing a gamma 4%/4 mm. The ability of the program to detect a variety of simulated errors has been tested. Conclusions: By using the patient's CT data, the independent dose calculation performs checks that are not performed by a measurement in a cylindrical phantom. This enables it to be used either as an additional check or to replace phantom measurements for some patients. The software has potential to be used in any application where one wishes to model changes to patient conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-AB-BRC-09: Fast Dose-Averaged LET and Biological Dose Calculations for Proton Therapy Using Graphics Cards

Purpose: To demonstrate fast and accurate Monte Carlo (MC) calculations of proton dose-averaged linear energy transfer (LETd) and biological dose (BD) on a Graphics Processing Unit (GPU) card. Methods: A previously validated GPU-based MC simulation of proton transport was used to rapidly generate LETd distributions for proton treatment plans. Since this MC handles proton-nuclei interactions on an event-by-event using a Bertini intranuclear cascade-evaporation model, secondary protons were taken into account. The smaller contributions of secondary neutrons and recoil nuclei were ignored. Recent work has shown that LETd values are sensitive to the scoring method. The GPU-based LETd calculations were verified by comparing with a TOPAS custom scorer that uses tabulated stopping powers, following recommendations by other authors. Comparisons were made for prostate and head-and-neck patients. A python script is used to convert the MC-generated LETd distributions to BD using a variety of published linear quadratic models, and to export the BD in DICOM format for subsequent evaluation. Results: Very good agreement is obtained between TOPAS and our GPU MC. Given a complex head-and-neck plan with 1 mm voxel spacing, the physical dose, LETd and BD calculations for 10{sup 8} proton histories can be completed in ∼5 minutes using a NVIDIA Titan X card. The rapid turnover means that MC feedback can be obtained on dosimetric plan accuracy as well as BD hotspot locations, particularly in regards to their proximity to critical structures. In our institution the GPU MC-generated dose, LETd and BD maps are used to assess plan quality for all patients undergoing treatment. Conclusion: Fast and accurate MC-based LETd calculations can be performed on the GPU. The resulting BD maps provide valuable feedback during treatment plan review. Partially funded by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Phase II Trial of Radiation Dose Escalation With Conformal External Beam Radiotherapy and High-Dose-Rate Brachytherapy Combined With Long-Term Androgen Suppression in Unfavorable Prostate Cancer: Feasibility Report

Purpose: To determine the feasibility of combined long-term luteinizing hormone-releasing hormone agonist-based androgen suppressive therapy (AST) and dose escalation with high-dose-rate (HDR) brachytherapy for high-risk (HRPC) or very-high-risk prostate cancer (VHRPC). Methods and Materials: Between January 2001 and October 2006, 134 patients (median age, 70 years) with either National Comprehensive Cancer Network criteria-defined HRPC (n = 47, 35.1%) or VHRPC (n = 87, 64.9%) were prospectively enrolled in this Phase II trial. Tumor characteristics included a median pretreatment prostate-specific antigen level of 14.6 ng/mL, a median clinical stage of T2c, and a median Gleason score of 7. Three-dimensional conformal radiotherapy (54 Gy in 30 fractions) was followed by HDR brachytherapy (19 Gy in 4 b.i.d. treatments). Androgen suppressive therapy started 0-3 months before three-dimensional conformal radiotherapy and continued for 2 years. Results: One implant was repositioned with a new procedure (0.7%). Five patients (3.7%) discontinued AST at a median of 13 months (range, 6-18 months) because of disease progression (n = 1), hot flashes (n = 2), fatigue (n = 1), and impotence (n = 1). After a median follow-up of 37.4 months (range, 24-90 months), the highest Radiation Therapy Oncology Group-defined late urinary toxicities were Grade 0 in 47.8%, Grade 1 in 38.1%, Grade 2 in 7.5%, and Grade 3 in 6.7% of patients. Maximal late gastrointestinal toxicities were Grade 0 in 73.1%, Grade 1 in 16.4%, Grade 2 in 7.5%, and Grade 3 in 2.9% of patients. There were no Grade 4 or 5 events. Conclusions: Intermediate-term results show that dose escalation with HDR brachytherapy combined with long-term AST is feasible and has a toxicity profile similar to that reported by previous HDR brachytherapy studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

'In vivo' Dose Measurements in High-Dose-Rate Brachytherapy Treatments for Cervical Cancer: A Project Proposal

The aim of this thesis project is to compare doses calculated from the treatment planning system using computed tomography images, with those measured 'in vivo' by using thermoluminescent dosimeters placed at different regions of the rectum and bladder of a patient during high-dose-rate intracavitary brachytherapy treatment of uterine cervical carcinoma. The experimental dosimeters characterisation and calibration have concluded and the protocol to carry out the 'in vivo' measurements has been established. In this work, the calibration curves of two types of thermoluminescent dosimeters (rods and chips) are presented, and the proposed protocol to measure the 'in vivo' dose is fully described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Defect sink characteristics of specific grain boundary types in 304 stainless steels under high dose neutron environments

Radiation induced segregation (RIS) is a well-studied phenomena which occurs in many structurally relevant nuclear materials including austenitic stainless steels. RIS occurs due to solute atoms preferentially coupling to mobile point defect fluxes that migrate and interact with defect sinks. Here, a 304 stainless steel was neutron irradiated up to 47.1 dpa at 320 °C. Investigations into the RIS response at specific grain boundary types were utilized to determine the sink characteristics of different boundary types as a function of irradiation dose. A rate theory model built on the foundation of the modified inverse Kirkendall (MIK) model is proposed and benchmarked to the experimental results. This model, termed the GiMIK model, includes alterations in the boundary conditions based on grain boundary structure and includes expressions for interstitial binding. This investigation, through experiment and modeling, found specific grain boundary structures exhibit unique defect sink characteristics depending on their local structure. Such interactions were found to be consistent across all doses investigated and had larger global implications including precipitation of Ni-Si clusters near different grain boundary types.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

ASCENDE-RT: An Analysis of Treatment-Related Morbidity for a Randomized Trial Comparing a Low-Dose-Rate Brachytherapy Boost with a Dose-Escalated External Beam Boost for High- and Intermediate-Risk Prostate Cancer

Purpose: To report the genitourinary (GU) and gastrointestinal (GI) morbidity and erectile dysfunction in a randomized trial comparing 2 methods of dose escalation for high- and intermediate-risk prostate cancer. Methods and Materials: ASCENDE-RT (Androgen Suppression Combined with Elective Nodal and Dose Escalated Radiation Therapy) enrolled 398 men, median age 68 years, who were then randomized to either a standard arm that included 12 months of androgen deprivation therapy and pelvic irradiation to 46 Gy followed by a dose-escalated external beam radiation therapy (DE-EBRT) boost to 78 Gy, or an experimental arm that substituted a low-dose-rate prostate brachytherapy (LDR-PB) boost. At clinic visits, investigators recorded GU and GI morbidity and information on urinary continence, catheter use, and erectile function. Exclusion of 15 who received nonprotocol treatment and correction of 14 crossover events left 195 men who actually received a DE-EBRT boost and 188, an LDR-PB boost. Median follow-up was 6.5 years. Results: The LDR-PB boost increased the risk of needing temporary catheterization and/or requiring incontinence pads. At 5 years the cumulative incidence of grade 3 GU events was 18.4% for LDR-PB, versus 5.2% for DE-EBRT (P<.001). Compared with the cumulative incidence, the 5-year prevalence of grade 3 GU morbidity was substantially lower for both arms (8.6% vs 2.2%, P=.058). The 5-year cumulative incidence of grade 3 GI events was 8.1% for LDR-PB, versus 3.2% for DE-EBRT (P=.124). The 5-year prevalence of grade 3 GI toxicity was lower than the cumulative incidence for both arms (1.0% vs 2.2%, respectively). Among men reporting adequate baseline erections, 45% of LDR-PB patients reported similar erectile function at 5 years, versus 37% after DE-EBRT (P=.30). Conclusions: The incidence of acute and late GU morbidity was higher after LDR-PB boost, and there was a nonsignificant trend for worse GI morbidity. No differences in the frequency of erectile dysfunction were observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose and dose rate effects on the microstructural and mechanical stability of long-range ordered precipitates in Inconel 718

Nickel-based alloys offer exceptional mechanical properties and corrosion resistance for various applications in extreme environments such as high neutron flux, temperature, and stress. Precipitates, resulting from thermal treatments, increase the strength and creep resistance of these alloys. Here, heavy ion irradiation is shown to destabilize the γ' and γ" precipitates in Inconel 718 nickel-based alloy by disordering and dissolution processes. Transmission electron microscopy and atom probe tomography reveal that the disordering and dissolution rates of the precipitates are proportional to both irradiation dose and dose rate. Irradiation induced disordering occurs at a higher rate than the dissolution. From analyzing the hardening contributions, microscale mechanical results suggest radiation-induced disordering is responsible for the majority of the softening response at low dose. In addition, low dose radiation-induced disordering results in strain localization and is believed to be the primary cause for the drastic degradation of uniform elongation and toughness in irradiated Inconel 718.

36 MATERIALS SCIENCE↗

Increased pattern transfer fidelity ZEP 520A during reactive ion etching through chemical modifications by additional dosing of the electron beam resist.

This article describes a postdevelopment, additional electron exposure to enhance the etch selectivity and improve pattern transfer fidelity of an electron beam resist, ZEP 520A, through chemical changes of the resist. After the critical features were patterned and developed, the resist was exposed at 5 kV accelerating voltage to a second dose of electrons ranging from 300 to 300,000 {micro}C/cm{sup 2}. The etch rate of the resist decreased by approximately 25% in a CHF{sub 3} and O{sub 2} plasma. More critically, the fidelity of the pattern transfer was improved. Infrared and Raman spectroscopies were used to characterize the resist before and after electron beam exposure for doses up to 3000 {micro}C/cm{sup 2}. The carbonyl bonding in the polymer showed significant changes after electron beam exposure that can be associated with improvement in the etch performance of this resist.

36 MATERIALS SCIENCE↗

PNNL Dose-per-Unit-Release Factors for Calculating Radionuclide Emissions Potential-to-Emit Doses

Revised PNNL-Richland campus dose-per-unit release factors based on the Environmental Protection Agency code CAP88-PC Version 4.1.1 code are provided. In addition to maximum receptor dose factors, maximum air concentration dose factors are provided. The PNNL-Sequim campus dose-per-unit release factors are included, as well, based on the Environmental Protection Agency code COMPLY Version 1.7.1.

40 CFR 61 Subpart H↗

Iron Oxide Nanoparticle Agglomeration Influences Dose-Rates and Modulates Oxidative Stress Mediated Dose-Response Profiles In Vitro

Spontaneous agglomeration of engineered nanoparticles (ENPs) is a common problem in cell culture media which can confound interpretation of in vitro nanotoxicity studies. The authors created stable agglomerates of iron oxide nanoparticles (IONPs) in conventional culture medium, which varied in hydrodynamic size (276 nm-1.5 μm) but were composed of identical primary particles with similar surface potentials and protein coatings. Studies using C10 lung epithelial cells show that the dose rate effects of agglomeration can be substantial, varying by over an order of magnitude difference in cellular dose in some cases. Quantification by magnetic particle detection showed that small agglomerates of carboxylated IONPs induced greater cytotoxicity and redox-regulated gene expression when compared with large agglomerates on an equivalent total cellular IONP mass dose basis, whereas agglomerates of amine-modified IONPs failed to induce cytotoxicity or redox-regulated gene expression despite delivery of similar cellular doses. Dosimetry modelling and experimental measurements reveal that on a delivered surface area basis, large and small agglomerates of carboxylated IONPs have similar inherent potency for the generation of ROS, induction of stress-related genes and eventual cytotoxicity. The results suggest that reactive moieties on the agglomerate surface are more efficient in catalysing cellular ROS production than molecules buried within the agglomerate core. Because of the dynamic, size and density-dependent nature of ENP delivery to cells in vitro, the biological consequences of agglomeration are not discernible from static measures of exposure concentration (μg/ml) alone, highlighting the central importance of integrated physical characterisation and quantitative dosimetry for in vitro studies. The combined experimental and computational approach provides a quantitative framework for evaluating relationships between the biocompatibility of nanoparticles and their physical and chemical characteristics.

agglomeration↗