Check of a three-dimensional reactor shielding code by comparison with ML-1 reactor experiment
Three dimensional Monte Carlo reactor shielding code evaluation by comparison with dose rate measurement on reactor shield assembly
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Three dimensional Monte Carlo reactor shielding code evaluation by comparison with dose rate measurement on reactor shield assembly
Purpose: The introduction of radioembolization with microspheres represents a significant step forward in the treatment of patients with metastatic disease to the liver. This technique uses semiempirical formulae based on body surface area or liver and target volumes to calculate the required total activity for a given patient. However, this treatment modality lacks extremely important information, which is the three-dimensional (3D) dose delivered by microspheres to different organs after their administration. The absence of this information dramatically limits the clinical efficacy of this modality, specifically the predictive power of the treatment. Therefore, the aim of this study is to develop a 3D dose calculation technique that is based on the PET imaging of the infused microspheres.Methods: The Fluka Monte Carlo code was used to calculate the voxel dose kernel for {sup 90}Y source with voxel size equal to that of the PET scan. The measured PET activity distribution was converted to total activity distribution for the subsequent convolution with the voxel dose kernel to obtain the 3D dose distribution. In addition, dose-volume histograms were generated to analyze the dose to the tumor and critical structures.Results: The 3D inpatient dose distribution can be reconstructed from the PET data of a patient scanned after the infusion of microspheres. A total of seven patients have been analyzed so far using the proposed reconstruction method. Four patients underwent treatment with SIR-Spheres for liver metastases from colorectal cancer and three patients were treated with Therasphere for hepatocellular cancer. A total of 14 target tumors were contoured on post-treatment PET-CT scans for dosimetric evaluation. Mean prescription activity was 1.7 GBq (range: 0.58–3.8 GBq). The resulting mean maximum measured dose to targets was 167 Gy (range: 71–311 Gy). Mean minimum dose to 70% of target (D70) was 68 Gy (range: 25–155 Gy). Mean minimum dose to 90% of target (D90) was 53 Gy (range: 13–125 Gy).Conclusions: A three-dimensional inpatient dose reconstruction method has been developed that is based on the PET/CT data of a patient treated with {sup 90}Y microspheres. It allows for a complete description of the absorbed dose by the tumor and critical structures. It represents the first step in building predictive models for treatment outcomes for patients receiving this therapeutic modality as well as it allows for better analysis of patients' dose response and will ultimately improve future treatment administration.
Purpose: Elekta Leksell Gamma Knife{sup ®} (LGK) is a radiotherapy beam machine whose features are not compliant with the international calibration protocols for radiotherapy. In this scope, the Laboratoire National Henri Becquerel and the Pitié-Salpêtrière Hospital decided to conceive a new LKG dose calibration method and to compare it with the currently used one. Furthermore, the accuracy of the dose delivered by the LGK machine was checked using an “end-to-end” test. This study also aims to compare doses delivered by the two latest software versions of the Gammaplan treatment planning system (TPS). Methods: The dosimetric method chosen is the electron paramagnetic resonance (EPR) of alanine. Dose rate (calibration) verification was done without TPS using a spherical phantom. Absolute calibration was done with factors calculated by Monte Carlo simulation (MCNP-X). For “end-to-end” test, irradiations in an anthropomorphic head phantom, close to real treatment conditions, are done using the TPS in order to verify the delivered dose. Results: The comparison of the currently used calibration method with the new one revealed a deviation of +0.8% between the dose rates measured by ion chamber and EPR/alanine. For simple fields configuration (less than 16 mm diameter), the “end-to-end” tests showed out average deviations of −1.7% and −0.9% between the measured dose and the calculated dose by Gammaplan v9 and v10, respectively. Conclusions: This paper shows there is a good agreement between the new calibration method and the currently used one. There is also a good agreement between the calculated and delivered doses especially for Gammaplan v10.
Purpose: Assessing the performance and uncertainty of a pre-calculated Monte Carlo (PMC) algorithm for proton and electron transport running on graphics processing units (GPU). While PMC methods have been described in the past, an explicit quantification of the latent uncertainty arising from recycling a limited number of tracks in the pre-generated track bank is missing from the literature. With a proper uncertainty analysis, an optimal pre-generated track bank size can be selected for a desired dose calculation uncertainty. Methods: Particle tracks were pre-generated for electrons and protons using EGSnrc and GEANT4, respectively. The PMC algorithm for track transport was implemented on the CUDA programming framework. GPU-PMC dose distributions were compared to benchmark dose distributions simulated using general-purpose MC codes in the same conditions. A latent uncertainty analysis was performed by comparing GPUPMC dose values to a “ground truth” benchmark while varying the track bank size and primary particle histories. Results: GPU-PMC dose distributions and benchmark doses were within 1% of each other in voxels with dose greater than 50% of Dmax. In proton calculations, a submillimeter distance-to-agreement error was observed at the Bragg Peak. Latent uncertainty followed a Poisson distribution with the number of tracks per energy (TPE) and a track bank of 20,000 TPE produced a latent uncertainty of approximately 1%. Efficiency analysis showed a 937× and 508× gain over a single processor core running DOSXYZnrc for 16 MeV electrons in water and bone, respectively. Conclusion: The GPU-PMC method can calculate dose distributions for electrons and protons to a statistical uncertainty below 1%. The track bank size necessary to achieve an optimal efficiency can be tuned based on the desired uncertainty. Coupled with a model to calculate dose contributions from uncharged particles, GPU-PMC is a candidate for inverse planning of modulated electron radiotherapy and scanned proton beams. This work was supported in part by FRSQ-MSSS (Grant No. 22090), NSERC RG (Grant No. 432290) and CIHR MOP (Grant No. MOP-211360)
Purpose: To investigate methods of generating accurate patient-specific computational phantoms for the Monte Carlo calculation of lung brachytherapy patient dose distributions. Methods: Four metallic artifact mitigation methods are applied to six lung brachytherapy patient computed tomography (CT) images: simple threshold replacement (STR) identifies high CT values in the vicinity of the seeds and replaces them with estimated true values; fan beam virtual sinogram replaces artifact-affected values in a virtual sinogram and performs a filtered back-projection to generate a corrected image; 3D median filter replaces voxel values that differ from the median value in a region of interest surrounding the voxel and then applies a second filter to reduce noise; and a combination of fan beam virtual sinogram and STR. Computational phantoms are generated from artifact-corrected and uncorrected images using several tissue assignment schemes: both lung-contour constrained and unconstrained global schemes are considered. Voxel mass densities are assigned based on voxel CT number or using the nominal tissue mass densities. Dose distributions are calculated using the EGSnrc user-code BrachyDose for{sup 125}I, {sup 103}Pd, and {sup 131}Cs seeds and are compared directly as well as through dose volume histograms and dose metrics for target volumes surrounding surgical sutures. Results: Metallic artifact mitigation techniques vary in ability to reduce artifacts while preserving tissue detail. Notably, images corrected with the fan beam virtual sinogram have reduced artifacts but residual artifacts near sources remain requiring additional use of STR; the 3D median filter removes artifacts but simultaneously removes detail in lung and bone. Doses vary considerably between computational phantoms with the largest differences arising from artifact-affected voxels assigned to bone in the vicinity of the seeds. Consequently, when metallic artifact reduction and constrained tissue assignment within lung contours are employed in generated phantoms, this erroneous assignment is reduced, generally resulting in higher doses. Lung-constrained tissue assignment also results in increased doses in regions of interest due to a reduction in the erroneous assignment of adipose to voxels within lung contours. Differences in dose metrics calculated for different computational phantoms are sensitive to radionuclide photon spectra with the largest differences for{sup 103}Pd seeds and smallest but still considerable differences for {sup 131}Cs seeds. Conclusions: Despite producing differences in CT images, dose metrics calculated using the STR, fan beam + STR, and 3D median filter techniques produce similar dose metrics. Results suggest that the accuracy of dose distributions for permanent implant lung brachytherapy is improved by applying lung-constrained tissue assignment schemes to metallic artifact corrected images.
Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with {sup 90}Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than other methods of dose calculation usually applied in the clinic.
Purpose: The detailed study of a new permanent iodine-125 brachytherapy source, SmartSeed, is presented in this article. It is the first iodine seed made with biocompatible polymer and is manufactured by the IBt-Bebig group. Methods: Three dosimetric studies have been performed: The first one used thermoluminescent detectors in a solid water phantom with NIST (National Institute of Standards and Technology, USA) calibrated seeds, and two separate studies were of Monte Carlo photon transport calculations (MCNP5 code). The TG-43U1 protocol was applied to derive dosimetric parameters for clinical applications. Results: The radial dose function g(r) was determined at different distances ranging from 0.5 to 10 cm; and the anisotropy function F(r,{theta}) at angles ranging from 0 deg. to 350 deg. in 10 deg. increments. Monte Carlo calculations were performed in liquid water to obtain values for {Lambda}, g(r), F(r,{theta}), and {phi}{sub an}(r) as recommended by the TG-43U1 protocol for use in treatment planning system software. SmartSeed's biocompatible polymer capsule permits fluorescence x rays (3, 5, and 12 keV), generated by lead glass marker, to be present in the emission spectrum, influencing the dose rate constant. The impact on near field dosimetry in water from these x rays was also investigated and reported. The capsule also attenuates iodine-125 energies much less than typical titanium encased sources, resulting in a highly isotropic source. Conclusions: SmartSeed has a dose rate constant of 0.895{+-}7.3% cGy h{sup -1} U{sup -1}, a radial dose function nearly identical to the IBt-Bebig model I25.S06 seed, and a highly isotropic dose distribution. Fluorescence x rays account for the relatively low value of {Lambda}, yet their variable contribution to dosimetry arising from seed dimensional uncertainties is estimated to be <0.2%.
While in orbit, Astronauts are exposed to a much higher dose of ionizing radiation than when on the ground. It is important to model how shielding designs on spacecraft reduce radiation effective dose pre-flight, and determine whether or not a danger to humans is presented. However, in order to calculate effective dose, dose equivalent calculations are needed. Dose equivalent takes into account an absorbed dose of radiation and the biological effectiveness of ionizing radiation. This is important in preventing long-term, stochastic radiation effects in humans spending time in space. Monte carlo simulations run with the particle transport code FLUKA, give absorbed and equivalent dose data for relevant shielding. The shielding geometry used in the dose calculations is a layered slab design, consisting of aluminum, polyethylene, and water. Water is used to simulate the soft tissues that compose the human body. The results obtained will provide information on how the shielding performs with many thicknesses of each material in the slab. This allows them to be directly applicable to modern spacecraft shielding geometries.
ADETS (Automated DEpletion Transport System) calculates coupled neutronic/isotopic results for nuclear systems and produces a large number of criticality and burnup results based on various material feed/removal specifications, power(s), and time intervals. ADETS is a fully automated tool that links the LANL MCNP Monte Carlo transport code with the SCALE system, specifically ORIGEN-ARP (radioactive decay and burnup code). Additionally, ADETS can compute the dose at various distances of the reactor using a point gamma source, whose characteristics are computed by ORIGEN-ARP. In addition, ADETS is fully coupled with the Uncertanty Quantification, Probabilistic Risk Assessment, Parameter Optimization and Data Analysis code RAVEN (developed at the Idaho National Laboratory as well). RAVEN is released with ADETS but MCNP and SCALE (ORIGEN-ARP) are not included.
Purpose: To commission Monte Carlo beam models for five Varian megavoltage photon beams (4, 6, 10, 15, and 18 MV). The goal is to closely match measured dose distributions in water for a wide range of field sizes (from 2x2 to 35x35 cm{sup 2}). The second objective is to reinvestigate the sensitivity of the calculated dose distributions to variations in the primary electron beam parameters. Methods: The GEPTS Monte Carlo code is used for photon beam simulations and dose calculations. The linear accelerator geometric models are based on (i) manufacturer specifications, (ii) corrections made by Chibani and Ma [''On the discrepancies between Monte Carlo dose calculations and measurements for the 18 MV Varian photon beam,'' Med. Phys. 34, 1206-1216 (2007)], and (iii) more recent drawings. Measurements were performed using pinpoint and Farmer ionization chambers, depending on the field size. Phase space calculations for small fields were performed with and without angle-based photon splitting. In addition to the three commonly used primary electron beam parameters (E{sub AV} is the mean energy, FWHM is the energy spectrum broadening, and R is the beam radius), the angular divergence ({theta}) of primary electrons is also considered. Results: The calculated and measured dose distributions agreed to within 1% local difference at any depth beyond 1 cm for different energies and for field sizes varying from 2x2 to 35x35 cm{sup 2}. In the penumbra regions, the distance to agreement is better than 0.5 mm, except for 15 MV (0.4-1 mm). The measured and calculated output factors agreed to within 1.2%. The 6, 10, and 18 MV beam models use {theta}=0 deg., while the 4 and 15 MV beam models require {theta}=0.5 deg. and 0.6 deg., respectively. The parameter sensitivity study shows that varying the beam parameters around the solution can lead to 5% differences with measurements for small (e.g., 2x2 cm{sup 2}) and large (e.g., 35x35 cm{sup 2}) fields, while a perfect agreement is maintained for the 10x10 cm{sup 2} field. The influence of R on the central-axis depth dose and the strong influence of {theta} on the lateral dose profiles are demonstrated. Conclusions: Dose distributions for very small and very large fields were proved to be more sensitive to variations in E{sub AV}, R, and {theta} in comparison with the 10x10 cm{sup 2} field. Monte Carlo beam models need to be validated for a wide range of field sizes including small field sizes (e.g., 2x2 cm{sup 2}).
Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.
This report discusses a preliminary assessment of the capabilities of current state-of-the-art stochastic codes Shift and MCNP6 to calculate the ex-core radiation dose rates for a simplified Molten Salt Reactor (MSR) model. The Monte Carlo code Shift has been under significant development in recent years at ORNL as part of the CASL program and is now supported by NEAMS. Originally, Shift was developed for LWR ex-core calculations but with dose rate and shielding calculations specifically requested by the NEAMS program’s MSR industry partners, the MSR Application Drivers team was tasked with assessing Shift for non-LWR applications. This was the first application of the Shift code for non-LWRs and the findings can be considered preliminary due to the activities occurring only over a 5-month period. Attractive features of Shift include massive parallelization and advanced automated variance reduction techniques such as CADIS and FW-CADIS.
A bremsstrahlung source term has been developed by the Radiation Protection (RP) group at SLAC National Accelerator Laboratory for high-intensity short-pulse laser–solid experiments between 10 17 and 10 22 W cm –2 . This source term couples the particle-in-cell plasma code EPOCH and the radiation transport code FLUKA to estimate the bremsstrahlung dose yield from laser–solid interactions. EPOCH characterizes the energy distribution, angular distribution, and laser-to-electron conversion efficiency of the hot electrons from laser–solid interactions, and FLUKA utilizes this hot electron source term to calculate a bremsstrahlung dose yield (mSv per J of laser energy on target). The goal of this paper is to provide RP guidelines and hazard analysis for high-intensity laser facilities. In conclusion, a comparison of the calculated bremsstrahlung dose yields to radiation measurement data is also made.
Simulation by the Monte Carlo method is widely used to calculate the character of ionizing radiation interaction with substance. A wide variety of programs based on the given method allows users to choose the most suitable package for solving computational problems. In turn, it is important to know exactly restrictions of numerical systems to avoid gross errors. Results of estimation of the feasibility of application of the program PCLab (Computer Laboratory, version 9.9) for numerical simulation of the electron energy distribution absorbed in beryllium, aluminum, gold, and water for industrial, research, and clinical beams are presented. The data obtained using programs ITS and Geant4 being the most popular software packages for solving the given problems and the program PCLab are presented in the graphic form. A comparison and an analysis of the results obtained demonstrate the feasibility of application of the program PCLab for simulation of the absorbed energy distribution and dose of electrons in various materials for energies in the range 1–20 MeV.
This report documents work performed supporting the US Department of Energy (DOE) Office of Nuclear Energy (NE) Spent Fuel and Waste Disposition (SFWD) Integrated Waste Management activities under work breakdown structure element 1.08.02.04.01, “Data and Tools Development, Validation, and Maintenance.” In particular, this report fulfills milestone M3SF-21OR020401016, “Implement on-the-fly dose analysis methodology in UNF-ST&DARDS” within work package SF-21OR02040101, “Commercial SNF Characterization - ORNL.” The Used Nuclear Fuel - Storage, Transportation & Disposal Analysis Resource and Data System (UNFST& DARDS) enables automated dose rate calculations for spent nuclear fuel (SNF) transportation packages and storage casks using a Monte Carlo radiation transport code. The explicit method uses a detailed model of the SNF system and its contents. Therefore, a dose rate calculation is required for each as-loaded transportation package or storage cask because the SNF assemblies within a canister typically have unique irradiation characteristics. An alternate method, referred to as the “on-the-fly” shielding analysis method, has been proposed that requires only a set of Monte Carlo dose rate calculations for each transportation packaging/storage cask design. The results of the Monte Carlo dose rate calculations are independent of the SNF assembly irradiation and decay characteristics. The dose rate values may then be combined with the radiation source strength of the SNF assemblies associated with a particular transportation packaging/storage cask design to determine actual dose rates. This report presents on-the-fly dose rate calculations for a representative SNF storage cask and verification of the on-the-fly dose rate calculation results by comparison with reference dose rate calculations using the explicit Monte Carlo dose rate calculation. The on-the-fly shielding analysis method was implemented in UNF-ST&DARDS. A Python program was developed to process the MAVRIC dose rate results obtained by source particle type, energy group, and fuel geometry region. A Python processor created binary files, which were saved as a special UNF-ST&DARDS library for on-the- fly shielding analyses. UNF-ST&DARDS uses the precalculated on-the-fly binary libraries generated by the Python data processor and directly executes the Python code for on-the-fly dose analysis. This Python code unzips the pre-generated binary files mentioned above, reads the data, and combines them with user-specified sources for dose and uncertainty calculations. The Python programs were verified using Excel calculations and by comparison with the values obtained with the MAVRIC post-processing utilities applied to the 3dmap files. This method can currently be used to determine dose rates for as-loaded HI-STORM FW storage casks. The UNF-ST&DARDS analysis wizard for on-the-fly shielding analysis is described in this report.
Purpose: In prostate HDR brachytherapy dose distributions are highly sensitive to changes in prostate volume and catheter displacements. We investigate the maximum deformations in implant geometry before planning objectives are violated. Methods: A typical prostate Ir-192 HDR brachytherapy reference plan was calculated on the Oncentra planning system, which used CT images from a tissue equivalent prostate phantom (CIRS Model 053S) embedded inside a pelvis wax phantom. The prostate was deformed and catheters were displaced in simulations using a code written in MATLAB. For each deformation dose distributions were calculated, based on TG43 methods, using the MATLAB code. The calculations were validated through comparison with Oncentra calculations for the reference plan, and agreed within 0.12%SD and 0.3%SD for dose and volume, respectively. Isotropic prostate volume deformations of up to +34% to −27% relative to its original volume, and longitudinal catheter displacements of 7.5 mm in superior and inferior directions were simulated. Planning objectives were based on American Brachytherapy Society guidelines for prostate and urethra volumes. A plan violated the planning objectives when less than 90% of the prostate volume received the prescribed dose or higher (V{sub 100}), or the urethral volume receiving 125% of prescribed dose or higher was more than 1 cc (U{sub 125}). Lastly, the dose homogeneity index (DHI=1-V{sub 150}/V{sub 100}) was evaluated; a plan was considered sub-optimal when the DHI fell below 0.62. Results and Conclusion: Planning objectives were violated when the prostate expanded by 10.7±0.5% or contracted by 11.0±0.2%; objectives were also violated when catheters were displaced by 4.15±0.15 mm and 3.70±0.15 mm in the superior and inferior directions, respectively. The DHI changes did not affect the plan optimality, except in the case of prostate compression. In general, catheter displacements have a significantly larger impact on plan optimality than prostate volume changes.
External photon beam radiotherapy is carried out in a way to achieve an 'as low as possible' a dose in healthy tissues surrounding the target. One of these surroundings can be heart as a vital organ of body. As it is impossible to directly determine the absorbed dose by heart, using phantoms is one way to acquire information around it. The other way is Monte Carlo method. In this work we have presented a simulation of heart geometry by introducing of different surfaces in MCNP code. We used 14 surface equations in order to determine human heart modeling. Those surfaces are borders of heart walls and contents.
Purpose: To develop a quantitative method for the estimation of kV cone beam computed tomography (kVCBCT) doses in pediatric patients undergoing image-guided radiotherapy. Methods and Materials: Forty-two children were retrospectively analyzed in subgroups of different scanned regions: one group in the head-and-neck and the other group in the pelvis. Critical structures in planning CT images were delineated on an Eclipse treatment planning system before being converted into CT phantoms for Monte Carlo simulations. A benchmarked EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions of kVCBCT scans with full-fan high-quality head or half-fan pelvis protocols predefined by the manufacturer. Based on planning CT images and structures exported in DICOM RT format, occipital-frontal circumferences (OFC) were calculated for head-and-neck patients using DICOMan software. Similarly, hip circumferences (HIP) were acquired for the pelvic group. Correlations between mean organ doses and age, weight, OFC, and HIP values were analyzed with SigmaPlot software suite, where regression performances were analyzed with relative dose differences (RDD) and coefficients of determination (R{sup 2}). Results: kVCBCT-contributed mean doses to all critical structures decreased monotonically with studied parameters, with a steeper decrease in the pelvis than in the head. Empirical functions have been developed for a dose estimation of the major organs at risk in the head and pelvis, respectively. If evaluated with physical parameters other than age, a mean RDD of up to 7.9% was observed for all the structures in our population of 42 patients. Conclusions: kVCBCT doses are highly correlated with patient size. According to this study, weight can be used as a primary index for dose assessment in both head and pelvis scans, while OFC and HIP may serve as secondary indices for dose estimation in corresponding regions. With the proposed empirical functions, it is possible to perform an individualized quantitative dose assessment of kVCBCT scans.