Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Modal Analysis with the Mobile Modal Testing Unit

Recently, National Aeronautics and Space Administration's (NASA's) White Sands Test Facility (WSTF) has tested rocket engines with high pulse frequencies. This has resulted in the use of some of WSTF's existing thrust stands, which were designed for static loading, in tests with large dynamic forces. In order to ensure that the thrust stands can withstand the dynamic loading of high pulse frequency engines while still accurately reporting the test data, their vibrational modes must be characterized. If it is found that they have vibrational modes with frequencies near the pulsing frequency of the test, then they must be modified to withstand the dynamic forces from the pulsing rocket engines. To make this determination the Mobile Modal Testing Unit (MMTU), a system capable of determining the resonant frequencies and mode shapes of a structure, was used on the test stands at WSTF. Once the resonant frequency has been determined for a test stand, it can be compared to the pulse frequency of a test engine to determine whether or not that stand can avoid resonance and reliably test that engine. After analysis of test stand 406 at White Sands Test Facility, it was determined that natural frequencies for the structure are located around 75, 125, and 240 Hz, and thus should be avoided during testing.

Wilder, Andrew J.↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Experimental Characterization of Hysteresis in a Revolute Joint for Precision Deployable Structures

Recent studies of the micro-dynamic behavior of a deployable telescope metering truss have identified instabilities in the equilibrium shape of the truss in response to low-energy dynamic loading. Analyses indicate that these micro-dynamic instabilities arise from stick-slip friction within the truss joints (e.g., hinges and latches). The present study characterizes the low-magnitude quasi-static load cycle response of the precision revolute joints incorporated in the deployable telescope metering truss, and specifically, the hysteretic response of these joints caused by stick-slip friction within the joint. Detailed descriptions are presented of the test setup and data reduction algorithms, including discussions of data-error sources and data-filtering techniques. Test results are presented from thirteen specimens, and the effects of joint preload and manufacturing tolerances are investigated. Using a simplified model of stick-slip friction, a relationship is made between joint load-cycle behavior and micro-dynamic dimensional instabilities in the deployable telescope metering truss.

Lake, Mark S.↗

Dynamic Modeling and Characterization of Nuclear-grade Graphite

Idaho National Labs serves as the spearhead for many innovative energy solutions to the world's energy crisis. One such solution is the INL's Microreactor which is designed to deploy to extreme/remote environments where other sources of power are either unavailable or unreliable. In order to best design these energy solutions for their operational environments, it is crucial to understand how the design, components, and materials will respond to the environmental conditions. One key material in these innovative designs is a nuclear-grade graphite known as PCEA. This study examines the behavior of PCEA graphite under dynamic loading, similar to that which may occur in extreme environments. The objective is to characterize the dynamic behavior and produce an accurate, reliable constitutive model suitable for use in simulation tools such as INL's MOOSE. Graphite specimens were tested using a Split Hopkinson Pressure Bar (SHPB) to administer the dynamic compressive load. The SHPB was charged at various pressures to produce a range of strain rates on the material in compression. Data was acquired via strain gauges on the SHPB setup, from which stress, strain, and time data were collected. Analysis revealed the stress-strain behavior of the material as well as insights into the material behavior's relationship to strain rate. Further work must continue to characterize the various other dynamic behaviors of the material which will combine to create a substantially trustworthy constitutive model for this grade of nuclear-grade graphite. Ultimately, this will allow for realistic simulation of the material in reactor designs, allowing for prediction of design weaknesses and leading to improved designs for increased resilience, security, and reliability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of a novel finite difference method to dynamic crack problems

A versatile finite difference method (HEMP and HEMP 3D computer programs) was developed originally for solving dynamic problems in continuum mechanics. It was extended to analyze the stress field around cracks in a solid with finite geometry subjected to dynamic loads and to simulate numerically the dynamic fracture phenomena with success. This method is an explicit finite difference method applied to the Lagrangian formulation of the equations of continuum mechanics in two and three space dimensions and time. The calculational grid moves with the material and in this way it gives a more detailed description of the physics of the problem than the Eulerian formulation.

Chen, Y. M.↗

A program for calculating load coefficient matrices utilizing the force summation method, L218 (LOADS). Volume 2: Supplemental system design and maintenance document

The LOADS computer program L218 which calculates dynamic load coefficient matrices utilizing the force summation method is described. The load equations are derived for a flight vehicle in straight and level flight and excited by gusts and/or control motions. In addition, sensor equations are calculated for use with an active control system. The load coefficient matrices are calculated for the following types of loads: (1) translational and rotational accelerations, velocities, and displacements; (2) panel aerodynamic forces; (3) net panel forces; and (4) shears, bending moments, and torsions.

Anderson, L. R.↗

Buckling of circular cylindrical shells under dynamically applied axial loads

A theoretical and experimental study was made of the buckling characteristics of perfect and imperfect circular cylindrical shells subjected to dynamic axial loading. Experimental data included dynamic buckling loads (124 data points), high speed photographs of buckling mode shapes and observations of the dynamic stability of shells subjected to rapidly applied sub-critical loads. A mathematical model was developed to describe the dynamic behavior of perfect and imperfect shells. This model was based on the Donnell-Von Karman compatibility and equilibrium equations and had a wall deflection function incorporating five separate modes of deflection. Close agreement between theory and experiment was found for both dynamic buckling strength and buckling mode shapes.

Tulk, J. D.↗

Simulation of Space Station loads with active control systems

A methodology for calculating dynamic loads for the Space Station Freedom is presented. The methodology minimizes the repeated calculation of duplicate structural elements, while analyzing a large number of different Space Station configurations with different alpha and beta joint angles. Particular attention is paid to the issue of model reduction using a combination of component mode synthesis (superelements) and component mode selection to generate accurate system level models with a minimum of modal degrees of freedom. The modeling of the control systems during simulation of the structural response is discussed.

Blelloch, P. A.↗

Omega-Limit Sets and Input-To-State Stability in Power Grids with Switching Equilibria

This paper studies a power transmission system with both conventional generators (CGs) and distributed energy assets (DEAs) providing frequency control. We consider an operating condition with demand aggregating two dynamic components: one that switches between different values on a finite set, and one that varies smoothly over time. Such dynamic operating conditions may result from protection scheme activations, external cyber-attacks, or due to the integration of dynamic loads, such as data centers. Mathematically, the dynamics of the resulting system are captured by a system that switches between a finite number of vector fields - or modes -, with each mode having a distinct equilibrium point induced by the demand aggregation. To analyze the stability properties of the resulting switching system, we leverage tools from hybrid dynamic inclusions and the concept of ..omega.. -limit sets from sets. Specifically, we characterize a compact set that is semi-globally practically asymptotically stable under the assumption that the switching frequency and load variation rate are sufficiently slow. For arbitrarily fast variations of the load, we use a level-set argument with multiple Lyapunov functions to establish input-to-state stability of a larger set and with respect to the rate of change of the loads. The theoretical results are illustrated via numerical simulations on the IEEE 39-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Modeling of Control-Structure Interaction in Thrust Vector Control Systems

The Space Launch System (SLS) Core Stage (CS) Thrust Vector Control (TVC) system is comprised of 8 mechanical feedback Shuttle heritage Type III TVC actuators and four RS-25 engines, each attached to a Shuttle heritage gimbal block/bearing. Two actuators are used to move each engine in two planes perpendicular to one another (i.e., pitch and yaw). The TVC system design leverages hardware from the Space Shuttle program as well as new hardware designed specifically for the Core Stage. During the development of the SLS TVC system, a family of advanced dynamics models were developed to extend and compliment the simplified quasi-linear “simplex” model historically used for flight control design and stability analysis. The importance of these advanced models became increasingly evident after ambient and hot fire testing of the Core Stage, which revealed a number of findings associated with the dynamic response of the TVC integrated system. Test responses suggested that the TVC did not meet its performance specifications and its step and frequency responses exhibited unexpected departures from prior lab tests and modeled behavior. One driving factor for these results was a higher-than-expected degree of coupling between the TVC system, the engine dynamics, and the Core Stage structure. This paper is the third installment in a seven-paper series surveying the design, engineering, test validation, and flight performance of the Core Stage Thrust Vector Control system. In this paper, a new method of modeling rocket vehicle thrust vectoring servoelastic dynamics is presented. In this approach, the load dynamics are replaced by a detailed finite element model containing both the rigid body and elastic modes. A partitioning technique is used to compute the effective compliance from the modal data and obtain accurate simulation results using a reduced number of generalized coordinates. Coupled backup structure and nozzle attach compliance effects on multiple engines are captured in higher fidelity than with a spring approximation, eliciting novel effects due to the complex load paths involved in the Core Stage structure. Validation of the model is demonstrated using a variety of structural/modal, laboratory, and full-scale hot fire test data.

Launch Vehicles↗

Advanced Modeling of Control-Structure Interaction in Thrust Vector Control Systems

The Space Launch System (SLS) Core Stage (CS) Thrust Vector Control (TVC) system is comprised of 8 mechanical feedback Shuttle heritage Type III TVC actuators and four RS-25 engines, each attached to a Shuttle heritage gimbal block/bearing. Two actuators are used to move each engine in two planes perpendicular to one another (i.e., pitch and yaw). The TVC system design leverages hardware from the Space Shuttle program as well as new hardware designed specifically for the Core Stage. During the development of the SLS TVC system, a family of advanced dynamics models were developed to extend and compliment the simplified quasi-linear “simplex” model historically used for flight control design and stability analysis. The importance of these advanced models became increasingly evident after ambient and hot fire testing of the Core Stage, which revealed a number of findings associated with the dynamic response of the TVC integrated system. Test responses suggested that the TVC did not meet its performance specifications and its step and frequency responses exhibited unexpected departures from prior lab tests and modeled behavior. One driving factor for these results was a higher-than-expected degree of coupling between the TVC system, the engine dynamics, and the Core Stage structure. This paper is the third installment in a seven-paper series surveying the design, engineering, test validation, and flight performance of the Core Stage Thrust Vector Control system. In this paper, a new method of modeling rocket vehicle thrust vectoring servoelastic dynamics is presented. In this approach, the load dynamics are replaced by a detailed finite element model containing both the rigid body and elastic modes. A partitioning technique is used to compute the effective compliance from the modal data and obtain accurate simulation results using a reduced number of generalized coordinates. Coupled backup structure and nozzle attach compliance effects on multiple engines are captured in higher fidelity than with a spring approximation, eliciting novel effects due to the complex load paths involved in the Core Stage structure. Validation of the model is demonstrated using a variety of structural/modal, laboratory, and full-scale hot fire test data.

Launch Vehicles↗