Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC FIELD STRENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The steady state toroidal magnetic field at the core-mantle boundary

Recent measurements indicate that the strength of the toroidal magnetic field at Earth's core-mantle boundary is comparable in strength to the poloidal field - 5 to 10 gauss. Calculations are given to show that this is an inevitable result of the external boundary condition on the core, in which the mantle electrical conductivity is several orders of magnitude lower than that of the core. The measurements are shown to imply that the internal core magnetic field is in the range of several hundred gauss. Thus the measurements imply that the Earth's core contains a strong toroidal magnetic field. They also support the idea that Earth's dynamo, and by implication, other planetary magnetic fields, involves efficient toroidal magnetic field generation through strong differential rotation.

Pearce, S. J.↗

Plasma wave turbulence in the strong coupling region at comet Giacobini-Zinner

Within 100,000 km of comet Giacobini-Zinner's nucleus, strong plasma wave turbulence was detected by the ICE electric and magnetic field wave instruments. The spatial profiles of the wave amplitudes are compared with measurements of the heavy ion fluxes of cometary origin, the plasma electron density, and the magnetic field strength. The general similarity of the wave and heavy ion profiles suggest that the waves might be generated by free energy in the pick-up ion distribution function. However, the expected parallel streaming instability of electrostatic modes generates waves with frequencies that are too low to explain the observations. The observed low frequency magnetic turbulence is plausibly explained by the lower hybrid loss-cone instability of heavy ions.

Coroniti, F. V.↗

Classification of Tropical Oceanic Precipitation using High Altitude Aircraft: Microwave and Electric Field Measurements

During the 1998 and 2001 hurricane seasons of the western Atlantic Ocean and Gulf of Mexico, the Advanced Microwave Precipitation Radiometer (AMPR), the ER-2 Doppler (EDOP) radar, and the Lightning Instrument Package (LIP) were flown aboard the National Aeronautics and Space Administration ER-2 high altitude aircraft as part of the Third Convection and Moisture Experiment (CAMEX-3) and the Fourth Convection and Moisture Experiment (CAMEX-4). Several hurricanes, tropical storms, and other precipitation systems were sampled during these experiments. An oceanic rainfall screening technique has been developed using AMPR passive microwave observations of these systems collected at frequencies of 10.7, 19.35,37.1, and 85.5 GHz. This technique combines the information content of the four AMPR frequencies regarding the gross vertical structure of hydrometeors into an intuitive and easily executable precipitation mapping format. The results have been verified using vertical profiles of EDOP reflectivity and lower altitude horizontal reflectivity scans collected by the National Oceanic and Atmospheric Administration WP-3D Orion radar. Matching the rainfall classification results with coincident electric field information collected by the LIP readily identifies convective rain regions within the precipitation fields. This technique shows promise as a real-time research and analysis tool for monitoring vertical updraft strength and convective intensity from airborne platforms such as remotely operated or uninhabited aerial vehicles. The technique is analyzed and discussed for a wide variety of precipitation types using the 26 August 1998 observations of Hurricane Bonnie near landfall.

Hood, Robbie E.↗

Classification of Tropical Oceanic Precipitation using High-Altitude Aircraft Microwave and Electric Field Measurements

During the 1998 and 2001 hurricane seasons of the western Atlantic Ocean and Gulf of Mexico, the Advanced Microwave Precipitation Radiometer (AMPR), the ER-2 Doppler (EDOP) radar, and the Lightning Instrument Package (LIP) were flown aboard the NASA ER-2 high-altitude aircraft as part of the Third Convection and Moisture Experiment (CAMEX-3) and the Fourth Convection and Moisture Experiment (CAMEX-4). Several hurricanes, tropical storms, and other precipitation systems were sampled during these experiments. An oceanic rainfall screening technique has been developed using AMPR passive microwave observations of these systems collected at frequencies of 10.7, 19.35, 37.1, and 85.5 GHz. This technique combines the information content of the four AMPR frequencies regarding the gross vertical structure of hydrometeors into an intuitive and easily executable precipitation mapping format. The results have been verified using vertical profiles of EDOP reflectivity and lower-altitude horizontal reflectivity scans collected by the NOAA WP3D Orion radar. Matching the rainfall classification results with coincident electric field information collected by the LIP readily identifies convective rain regions within the precipitation fields. This technique shows promise as a real-time research and analysis tool for monitoring vertical updraft strength and convective intensity from airborne platforms such as remotely operated or uninhabited aerial vehicles. The technique is analyzed and discussed for a wide variety of precipitation types using the 26 August 1998 observations of Hurricane Bonnie near landfall.

Hood, Robbie E.↗

Surface electrical properties experiment, Part 3

A complete unified discussion of the electromagnetic response of a plane stratified structure is reported. A detailed and comprehensive analysis of the theoretical parts of the electromagnetic is given. The numerical problem of computing numbers of the electromagnetic field strengths is discussed. It is shown that the analysis of the conductive media is not very far removed from the theoretical analysis and the numerical difficulties are not as accute as for the low-loss problem. For Vol. 1, see N75-15570; for Vol. 2 see N75-15571.

Source record↗

The physics of the oscillating lightning

The lightning is proposed to start in a limited region of electric breakdown field. A growing charge pool in a cumulonimbus cloud is likely to produce such a field in its outer layers. When the field is not aligned with the potential surfaces, the electric force pushes positive charge in one direction and negative in the opposite. Self inductance develops and an embryo open electric circuit is born. Oscillations swiftly grow in strength when potential energy of the cloud is released. The channel extends in steps during those cycle stages where charge is crammed into the channel terminals. Electrostatic consequences of a narrow conductor among the cloud charges are computed. The conductor is charged by influence to such a degree that the charge is bound to leak out to the ambient air and appear as a charge sheath some distance off the channel. Ample energy is released to sustain the oscillations. The period increases with channel length and agrees well with observed time between steps. A ground strike leads to a shock pulse travelling up the channel.

Storebo, Per B.↗

Strain Sensitivity in Single Walled Carbon Nanotubes for Multifunctional Materials

Single walled carbon nanotubes represent the future of structural aerospace vehicle systems due to their unparalleled strength characteristics and demonstrated multifunctionality. This multifunctionality rises from the CNT's unique capabilities for both metallic and semiconducting electron transport, electron spin polarizability, and band gap modulation under strain. By incorporating the use of electric field alignment and various lithography techniques, a single wall carbon nanotube (SWNT) test bed for measurement of conductivity/strain relationships has been developed. Nanotubes are deposited at specified locations through dielectrophoresis. The circuit is designed such that the central, current carrying section of the nanotube is exposed to enable atomic force microscopy and manipulation in situ while the transport properties of the junction are monitored. By applying this methodology to sensor development a flexible single wall carbon nanotube (SWNT) based strain sensitive device has been developed. Studies of tensile testing of the flexible SWNT device vs conductivity are also presented, demonstrating the feasibility of using single walled HiPCO (high-pressure carbon monoxide) carbon nanotubes as strain sensing agents in a multi-functional materials system.

Heath, D. M.↗

Observations of the internal structure of the magnetopause

Magnetic field, plasma flux, and ELF wave data have been studied for several encounters of Ogo 5 with the earth's magnetopause. In one case of a crossing in the near-earth region of the geomagnetic tail, the structure agreed closely with a simple Chapman-Ferraro type of model with nearly complete neutralization of the charge separation electric field. Departures from the simple structure were observed at other magnetopause crossings. One crossing revealed a well-defined double structure with a large change in field direction closer to the earth than the ion flux and field strength gradients. The thickness of the magnetopause often depended on whether the change in field strength, the change in field direction, or the change in ion flux was being considered. Bursts of ELF waves were occasionally observed at the magnetopause.

Neugebauer, M.↗

Avionics electromagnetic interference immunity and environment

Aircraft electromagnetic spectrum and radio frequency (RF) field strengths are charted, profiling the higher levels of electromagnetic voltages encountered by the commercial aircraft wiring. Selected military, urban, and rural electromagnetic field levels are plotted and provide a comparison of radiation amplitudes. Low frequency magnetic fields and electric fields from 400 H(Z) power systems are charted versus frequency and wire separation to indicate induced voltages on adjacent or neighboring circuits. Induced EMI levels and attenuation characteristics of electric, magnetic, RF fields, and transients are plotted and graphed for common types of wire circuits. The significance of wire circuit returns and shielding is emphasized to highlight the techniques that help block the paths of electromagnetic interference and maintain avionic interface signal quality.

Clarke, C. A.↗

Production and Characterization of Carbon Nanotubes and Nanotube-Based Composites

The Nobel Prize winning discovery of the Buckuball (C60) in 1985 at Rice University by a group including Dr. Richard Smalley led to the whole new class of carbon allotropes including fullerenes and nanotubes. Especially interesting from many viewpoints are single-walled carbon nanotubes, which structurally are like a single graphitic sheet wrapped around a cylinder and capped at the ends. This cylinders have diameter as small as 0.5 - 2 nm (1/100,000th the diameter of a human hair) and are as long as 0.1 - 1 mm. Nanotubes are really individual molecules and believed to be defect-free, leading to high tensile strength despite their low density. Additionally, these fibers exhibit electrical conductivity as high as copper, thermal conductivity as high as diamond, strength 100 times higher than steel at one-sixth the weight, and high strain to failure. Thus it is believed that developments in the field of nanotechnology will lead to stronger and lighter composite materials for next generation spacecraft. Lack of a bulk method of production is the primary reason nanotubes are not used widely today. Toward this goal JSC nanotube team is exploring three distinct production techniques: laser ablation, arc discharge and chemical vapor deposition (CVD, in collaboration with Rice University). In laser ablation technique high-power laser impinges on the piece of carbon containing small amount of catalyst, and nanotubes self-assemble from the resulting carbon vapor. In arc generator similar vapor is created in arc discharge between carbon electrodes with catalyst. In CVD method nanotubes grow at much lower temperature on small catalyst particles from carbon-containing feedstock gas (methane or carbon monoxide). As of now, laser ablation produces cleanest material, but mass yield is rather small. Arc discharge produces grams of material, but purity is low. CVD technique is still in baby steps, but preliminary results look promising, as well as perspective of scaling the process up. We are also working on necessary purification of nanotubes. Applications of nanotubes are in such various fields as lightweight composites, molecular electronics, energy storage (electrodes in Li ion batteries), flat panel displays, conductive polymers, etc. JSC nanotube team is focused on development of lightweight materials. We work on the injection thermoset epoxies reinforced with nanotubes. Early results show good wetting of nanotube surface with epoxy, which is very important. More research will be possible as more nanotubes become available.

Nikolaev, Pavel↗

Tunnel effect measuring systems and particle detectors

Methods and apparatus for measuring gravitational and inertial forces, magnetic fields, or wave or radiant energy acting on an object or fluid in space provide an electric tunneling current through a gap between an electrode and that object or fluid in space and vary that gap with any selected one of such forces, magnetic fields, or wave or radiant energy acting on that object or fluid. These methods and apparatus sense a corresponding variation in an electric property of that gap and determine the latter force, magnetic fields, or wave or radiant energy in response to that corresponding variation, and thereby sense or measure such parameters as acceleration, position, particle mass, velocity, magnetic field strength, presence or direction, or wave or radiant energy intensity, presence or direction.

Kaiser, William J.↗

Tunnel effect measuring systems and particle detectors

Methods and apparatus for measuring gravitational and inertial forces, magnetic fields, or wave or radiant energy acting on an object or fluid in space provide an electric tunneling current through a gap between an electrode and that object or fluid in space and vary that gap with any selected one of such forces, magnetic fields, or wave or radiant energy acting on that object or fluid. These methods and apparatus sense a corresponding variation in an electric property of that gap and determine the latter force, magnetic fields, or wave or radiant energy in response to that corresponding variation, and thereby sense or measure such parameters as acceleration, position, particle mass, velocity, magnetic field strength, presence or direction, or wave or radiant energy intensity, presence or direction.

Kaiser, William J.↗

Tunnel effect wave energy detection

Methods and apparatus for measuring gravitational and inertial forces, magnetic fields, or wave or radiant energy acting on an object or fluid in space provide an electric tunneling current through a gap between an electrode and that object or fluid in space and vary that gap with any selected one of such forces, magnetic fields, or wave or radiant energy acting on that object or fluid. These methods and apparatus sense a corresponding variation in an electric property of that gap and determine the latter force, magnetic fields, or wave or radiant energy in response to that corresponding variation, and thereby sense or measure such parameters as acceleration, position, particle mass, velocity, magnetic field strength, presence or direction, or wave or radiant energy intensity, presence or direction.

Kaiser, William J.↗

Tunnel effect measuring systems and particle detectors

Methods and apparatus for measuring gravitational and inertial forces, magnetic fields, or wave or radiant energy acting on an object or fluid in space provide an electric tunneling current through a gap between an electrode and that object or fluid in space and vary that gap with any selected one of such forces, magnetic fields, or wave or radiant energy acting on that object or fluid. These methods and apparatus sense a corresponding variation in an electric property of that gap and determine the latter force, magnetic fields, or wave or radiant energy in response to that corresponding variation, and thereby sense or measure such parameters as acceleration, position, particle mass, velocity, magnetic field strength, presence or direction, or wave or radiant energy intensity, presence or direction.

Kaiser, William J.↗

Ion Velocity Characterization of the 12.5-kW Advanced Electric Propulsion System Engineering Hall Thruster

During development testing of the 12.5-kW Advanced Electric Propulsion System engineering unit Hall thruster, which is magnetically shielded, a laser-induced fluorescence test was performed. During this test, a third medium-energy ion population was found near the inner front pole cover in addition to two low-energy counter-streaming ion populations that were found in previous testing. This newly found ion population matched in characteristics with the single population found near the outer front pole cover. The measured characteristics of the medium-energy ions matched the behavior expected of them if they were energized by a plasma wave with magnetized electrons, such as a lower hybrid wave. Comparison of the data from this test to prior tests showed that this engineering thruster had very similar ion characteristics as the precursor laboratory thruster. The acceleration zone was found to move upstream with increasing background pressure, decreasing anode flowrate, and increasing magnetic field strength. For the low-energy ions, the energy of the ions arriving at the inner pole did not vary noticeably with background pressure but did increase with increasing magnetic field strength and decreasing anode flow rate. For the medium-energy ions, the energy of the ions increased with decreasing background pressure, decreasing anode flow rate, and increasing magnetic field strength. Testing at different cathode flow fraction showed that the energy of the low-energy ions from the cathode decreased with increasing cathode flow.

Electric propulsion↗

Pulsar Polar Cap Heating and Surface Thermal X-ray Emission: Curvature Radiation Pair Fronts - 1

We investigate the effect of pulsar polar cap (PC) heating produced by positrons returning from the upper pair formation front. Our calculations are based on a self-consistent treatment of the pair dynamics and the effect of electric field screening by the returning positrons. We calculate the resultant X-ray luminosities and discuss the dependence of the PC heating efficiencies on pulsar parameters, such as characteristic spin-down age, spin period, and surface magnetic field strength. In this study we concentrate on the regime where the pairs are produced in a magnetic field by curvature photons emitted by accelerating electrons. Our theoretical results are not in conflict with the available observational x-ray data and suggest that the effect of PC heating should significantly contribute to the thermal x-ray fluxes from middle-aged and old pulsars. The implications for current and future x-ray observations of pulsars are briefly outlined.

Harding, Alice K.↗

Measuring electrically charged particle fluxes in space using a fiber optic loop sensor

The purpose of this program was to demonstrate the potential of a fiber optic loop sensor for the measurement of electrically charged particle fluxes in space. The key elements of the sensor are a multiple turn loop of low birefringence, single mode fiber, with a laser diode light source, and a low noise optical receiver. The optical receiver is designed to be shot noise limited, with this being the limiting sensitivity factor for the sensor. The sensing element is the fiber optic loop. Under a magnetic field from an electric current flowing along the axis of the loop, there is a non-vanishing line integral along the fiber optic loop. This causes a net birefringence producing two states of polarization whose phase difference is correlated to magnetic field strength and thus, current in the optical receiver electronic processing. The objectives in this program were to develop a prototype laser diode powered fiber optic sensor. The performance specification of a minimum detectable current density of 1 (mu)amp/sq m-(radical)Hz, should be at the shot noise limit of the detection electronics. OPTRA has successfully built and tested a 3.2 m diameter loop with 137 turns of low birefringence optical fiber and achieved a minimum detectable current density of 5.4 x 10(exp-5) amps/(radical)Hz. If laboratory space considerations were not an issue, with the length of optical fiber available to us, we would have achieved a minimum detectable current density of 4 x 10(exp -7) amps/(radical)Hz.

Source record↗