Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The DREAM approach to demand-side emissions reductions in Indonesia, 2020–2060

Indonesia’s current energy system modeling is heavily focused on the supply side, but emissions reductions in the demand sector have a significant impact on advancing Indonesia’s ambitious emissions reductions goals. To address the gap, we develop a new modeling tool DREAM Indonesia based on a bottom-up, technology-rich demand side framework and formulate projections of demand-side emissions reductions in Indonesia in 2020–2060. We find that demand-side energy efficiency and electrification can halve the growth rate of final energy demand to 1.4% annually over 2020–2060 and reverse the growing trend of emissions. The feasibility of full electrification by 2060, coupled with rapid adoption of existing technologies, positions the building sector as a model for achievable decarbonization and a cornerstone of Indonesia’s emissions reductions ambitions. In the industrial sector, extensive emissions reductions of 87% by 2060 (compared to business-as-usual) are achievable through energy efficiency improvements, alongside enhanced material efficiency measures including optimized material usage, low-carbon substitutions, innovative technologies, and increased circularity. In the transportation sector, balancing final energy demand by incorporating energy efficiency improvements across all transport modes, along with electrification particularly in road transportation, could decrease the emissions by up to 82% in 2060 compared to business-as-usual. This study provides insights and modeling approaches for rapidly growing Asian economies as well as other developing countries facing combined development and decarbonization challenges.

DREAM Indonesia↗

A Perspective of Decarbonization Pathways in Future Buildings in the United States

The commitment of electrification and decarbonization goals in the United States (U.S.) will significantly change the performance of future buildings. To meet these goals, it is critical to summarize the existing research related to building electrification and decarbonization and discuss future research pathways. This paper provides a perspective on decarbonization pathways of future buildings in the U.S. A critical review of the existing research was conducted, which is divided into three closely linked categories: technologies, economic impacts, and code regulations. Technologies support investments and code regulations while marketing affects the design of building codes and standards. In the meantime, code regulations guide the development of technologies and marketing. Based on the review, future potential research directions for building decarbonization are then discussed. Due to the needs of building decarbonization, future research will be multidisciplinary, conducted at a large geographic scale, and involve a multitude of metrics, which will undoubtedly introduce new challenges. The perspective presented in this paper will provide policy-makers, researchers, building owners, and other stakeholders with a way to understand the impact of electrification and decarbonization of future buildings in the U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cradle-to-Grave Lifecycle Analysis of Greenhouse Gas Emissions of Light-Duty Passenger Vehicles in China: Towards a Carbon-Neutral Future

Vehicle electrification is considered a pathway for on-road transportation decarbonization in China. Different from the conventional gasoline vehicles whose emissions are mainly released from vehicle tailpipes, emissions of battery electric vehicles (BEVs) are from the upstream processes of electricity generation and vehicle manufacturing, thus a comprehensive lifecycle analysis and comparison of BEVs with gasoline vehicles is required to quantify the emission mitigation benefit of vehicle electrification and determine the path to a carbon-neutral future. In the study, we compare the cradle-to-grave (C2G) lifecycle greenhouse gas emissions of gasoline and electric vehicles in China and analyze the greenhouse gas emission reduction of vehicle electrification in different provinces. Results show that under the current technologies, the national average C2G GHG emissions for battery electric vehicles (BEVs) of 100 miles (i.e., 160 km) and 300 miles (i.e., 480 km) all-electric range (AER) are 231 and 279 g CO2eq/km, respectively, 22% and 5% lower than those for gasoline internal combustion engine vehicles (ICEVs). Improving vehicle fuel efficiency by hybridizing gasoline ICEVs can effectively reduce C2G emissions to 212 g CO2eq/km. At the provincial level, C2G GHG emissions of BEVs vary according to the provincial electricity mix. In eight provinces, C2G GHG emissions of BEVs with 300 miles AER (BEV300s) are higher than those of gasoline ICEVs due to the GHG-intensive coal-based electricity mix. In the future scenario, with low carbon fuels (such as high-level bioethanol blending gasoline) and electricity decarbonization, the national average C2G emissions of hybrid electric vehicles (HEVs) and BEV300s can be reduced to 55 and 73 g CO2eq/km, respectively. Further decrease of C2G GHG emissions relies on reducing vehicle-cycle emissions from material processing and vehicle component manufacturing.

33 ADVANCED PROPULSION SYSTEMS↗

Comparison of lightning observations from the KSC LDAR system with radar observations from the NCAR CP-2 radar

This grant supported observations of thunderstorms at Kennedy Space Center during the summer of 1995. In particular, we obtained detailed observations of lightning-producing storms over KSC with the CP2 radar of the National Center for Atmospheric Research (NCAR), for the purpose of comparing these with observations from KSC's Lightning Detection and Ranging (LDAR) system. The NCAR radar was a special purpose dual-polarization system for studying the development of precipitation in storms and was at KSC for another project, the Small Cumulus Microphysics Study - SCMS. We used the radar on a non-interference basis to obtain the desired observations. In addition we recorded the electrostatic field change of the lightning discharges at two locations. Subsequent to the field observational period we compared the LDAR lightning observations with the storm structure as indicated by the radar. The results obtained to date are summarized briefly as follows: (1) The initial lightning sequence in a small developing storm was observed to occur in a region of the storm where supercooled raindrops had frozen within the previous few minutes. This is consistent with the idea that the storm electrification is produced by interactions between ice particles. (2) The lightning discharges tended to avoid regions of supercooled liquid raindrops, possibly indicating that corona from the drops reduces any electrification in the vicinity of the drops. (3) 'Bilevel' lightning discharges within storms have been confirmed to be between the level of negative charge at mid-levels in the storm and the upper storm level. This is consistent with and expands upon our understanding that storms have a basic dipolar charge structure. (4) The upward channels of the intracloud lightning discharges are often aligned with shafts of strong precipitation, and often begin just above the upper extent of 40 dBZ reflectivity in the precipitation shaft. This is consistent with a precipitation-based mechanism of electrification.

Krehbiel, Paul↗

Radar Differential Phase Signatures of Ice Orientation for the Prediction of Lightning Initiation and Cessation

The majority of lightning-related casualties typically occur during thunderstorm initiation (e.g., first flash) or dissipation (e.g., last flash). The physics of electrification and lightning production during thunderstorm initiation is fairly well understood. As such, the literature includes a number of studies presenting various radar techniques (using reflectivity and, if available, other dual-polarimetric parameters) for the anticipation of initial electrification and first lightning flash. These radar techniques have shown considerable skill at forecasting first flash. On the other hand, electrical processes and lightning production during thunderstorm dissipation are not nearly as well understood and few, if any, successful techniques have been developed to anticipate the last flash and subsequent cessation of lightning. One promising approach involves the use of dual-polarimetric radar variables to infer the presence of oriented ice crystals in lightning producing storms. In the absence of strong vertical electric fields, ice crystals fall with their largest (semi-major) axis in the horizontal associated with gravitational and aerodynamic forces. In thunderstorms, strong vertical electric fields (100-200 kV m(sup -1)) have been shown to orient small (less than 2 mm) ice crystals such that their semi-major axis is vertical (or nearly vertical). After a lightning flash, the electric field is typically relaxed and prior radar research suggests that ice crystals rapidly resume their preferred horizontal orientation. In active thunderstorms, the vertical electric field quickly recovers and the ice crystals repeat this cycle of orientation for each nearby flash. This change in ice crystal orientation from primarily horizontal to vertical during the development of strong vertical electric fields prior to a lightning flash forms the physical basis for anticipating lightning initiation and, potentially, cessation. Research has shown that radar reflectivity (Z) and other co-polar back-scattering radar measurements like differential reflectivity (Z(sub dr)) typically measured by operational dual-polarimetric radars are not sensitive to these changes in ice crystal orientation. However, prior research has demonstrated that oriented ice crystals cause significant propagation effects that can be routinely measured by most dual-polarimetric radars from X-band (3 cm) to S-band (10 cm) wavelengths using the differential propagation phase shift (often just called differential phase, phi(sub dp)) or its range derivative, the specific differential phase (K(sub dp)). Advantages of the differential phase include independence from absolute or relative power calibration, attenuation, differential attenuation and relative insensitivity to ground clutter and partial beam occultation effects (as long as the signal remains above noise). In research mode, these sorts of techniques have been used to anticipate initial cloud electrification, lightning initiation, and cessation. In this study, we develop a simplified model of ice crystal size, shape, orientation, dielectric, and associated radar scattering and propagation effects in order to simulate various idealized scenarios of ice crystals responding to a hypothetical electric field and their dual-polarimetric radar signatures leading up to lightning initiation and particularly cessation. The sensitivity of the K(sub dp) ice orientation signature to various ice properties and radar wavelength will be explored. Since K(sub dp) is proportional to frequency in the Rayleigh- Gans scattering regime, the ice orientation signatures should be more obvious at higher (lower) frequencies (wavelengths). As a result, simulations at radar wavelengths from 10 cm down to 1 cm (Ka-band) will be conducted. Resonance effects will be considered using the T-matrix method. Since most K(sub dp) Vbased observations have been shown at S-band, we will present ice orientation signatures from C-band (UAH/NASA ARMOR) and X-bd (UAH MAX) dual-polarimetric radars located in Northern Alabama. Issues related to optimal radar scanning for the detection of oriented ice will be discussed. Preliminary suggestions on how these differential phase signatures of oriented ice could contribute to lightning initiation and cessation algorithms will be presented.

Carey, L.D.↗

Polarimetric and Multi-Doppler Radar Observations of Electrified and Unelectrified Wildfire Smoke Plumes

Pyrocumulus clouds above three Colorado wildfires (Hewlett Gulch, High Park, and Waldo Canyon; all occurred during summer 2012) electrified and produced small intracloud discharges whenever the smoke plumes grew to high altitudes (over 10 km above mean sea level, or MSL). This occurred during periods of rapid wildfire growth, as indicated by the shortwave infrared channel on a geostationary satellite, as well as by incident reports. In the Hewlett Gulch case, the fire growth led to increased updrafts within the plume, as inferred by multiple‐ Doppler radar syntheses, which led to the vertical development and subsequent electrification ‐ a life cycle as short as 30 minutes. The lightning, detected by a threedimensional lightning mapping network, was favored in high‐altitude regions (~10 km MSL) containing modest reflectivities (25 dBZ and lower), ~0 dB differential reflectivity, and reduced correlation coefficient (~0.6‐0.7). This indicated the likely presence of ice particles (crystals and aggregates, possibly rimed) mixed with ash. Though neither multiple‐Doppler nor polarimetric observations were available during the electrification of the High Park and Waldo Canyon plumes, their NEXRAD observations showed reflectivity structures consistent with Hewlett Gulch. In addition, polarimetric and multiple‐Doppler scanning of unelectrified High Park plumes indicated only irregularly shaped ash, and not ice, was present (i.e., reflectivities < 25 dBZ, differential reflectivity > 5 dB, correlation < 0.4), and there was no broaching of the 10 km altitude. Based on these results, the electrification likely was caused by ice‐based processes that did not involve significant amounts of graupel. The results demonstrate the scientific value of multiple‐Doppler and polarimetric radar observations of wildfire smoke plumes ‐ including the ability to distinguish between regions of pure hydrometeors, regions of pure ash, and mixtures of both ‐ and also suggest a possible new application for lightning data in monitoring wildfires.

Lang, Timothy J.↗

Hybrid Electric Aircraft Thermal Management: Now, New Visions and Future Concepts and Formulation

The global fuel consumption by commercial airlines has increased each year since 2009 and is predicted to reach an all-time high of 97 billion gallons in 2019. There is also an environmental impact from this: CO2 emissions from commercial passenger and freight operations totaled 918 Mt in 2018 (ICCT, 2019), or around 2.5% of global energy-related CO2 emissions. Passenger transport accounted for 81% of the total. Emissions from aviation have grown 32% over the past five years. Coupled with this aspect, there is a continuous and growing need to satisfy ever-growing electrical power needs on commercial and military aircraft. All the armed services (Army, Navy, and Air Force) are continuously trying to enhance UAV (unmanned aerial vehicle) endurance and range across a broad fleet of different aircraft. The commercial Boeing 787 requires about 1.2MWe and that is expected to grow. Current technologies used to supply increased on-board electrical power are generally: 1) “burn more fuel and convert through on-board generators” and 2) use additional heavy (i.e., weight-inefficient) and sometimes unsafe battery systems on-board the aircraft. The aircraft industry is seeking new, innovative ways to satisfy this increasing power demand. One as-yet-untapped power source is the enormous amount of “waste” thermal energy flowing out the jet engine exhaust; some estimates in smaller “by-pass” flow jet engines is several hundreds of kilowatts (e.g., Pratt & Whitney Canada PW545B turbofan). This quantity is much higher in large jet engines associated with commercial aircraft. This large waste thermal energy manifests itself in large temperature differences within the by-pass-flow engine exhaust system relative to outside ambient conditions, because of the actual by-pass engine design configuration. There is strong need to develop thermal technologies and systems that could harness and convert at least a portion of this thermal energy into useful electrical energy to satisfy growing on-board electrical needs. In addition, there is a strong desire within the aircraft and engine manufacturing community to reduce the “carbon footprint” of the industry though reduced fuel usage worldwide. NASA has a robust aircraft electrification program to meet these desires and support industry in its aircraft electrification objectives. This program is integrating thermoacoustic systems, advanced lightweight heat exchanger technology, and advanced heat pipe technology to capture and transport large amounts of engine waste thermal energy for on-board power conversion, advanced heat-pump cooling, and exergy enhancement (i.e., temperature lift). Advanced lightweight heat exchangers are envisioned to capture engine exhaust thermal energy at approximately 673 K and deliver it to efficient thermoacoustic power conversion systems operating at temperature ratios (Thot/Tcold) > 1.6. Advanced heat pipe systems are envisioned to transport thermal energy from low temperature sources, through thermoacoustic heat pumps, to high temperature needs such as wing anti-icing, fuel pre-heating, and combustion air pre-heating. The paper will discuss the current state-of-the-art, objectives, system design architecture, and remaining technical challenges in system formulation within the NASA aircraft electrification program.

Dyson, Rodger↗

Electric vehicle supply equipment location and capacity allocation for fixed-route networks

Electric vehicle (EV) supply equipment location and allocation (EVSELCA) problems for freight vehicles are becoming more important because of the trending electrification shift. Some previous works address EV charger location and vehicle routing problems simultaneously by generating vehicle routes from scratch. Although such routes can be efficient, introducing new routes may violate practical constraints, such as drive schedules, and satisfying electrification requirements can require dramatically altering existing routes. To address the challenges in the prevailing adoption scheme, we approach the problem from a fixed -route perspective. We develop a mixed -integer linear program, a clustering approach, and a metaheuristic solution method using a genetic algorithm (GA) to solve the EVSELCA problem. The clustering approach simplifies the problem by grouping customers into clusters, while the GA generates solutions that are shown to be nearly optimal for small problem cases. A case study examines how charger costs, energy costs, the value of time (VOT), and battery capacity impact the cost of the EVSELCA. Charger equipment costs were found to be the most significant component in the objective function, leading to a substantial reduction in cost when decreased. VOT costs exhibited a significant decrease with rising energy costs. Further, an increase in VOT resulted in a notable rise in the number of fast chargers. Longer EV ranges decrease total costs up to a certain point, beyond which the decrease in total costs is negligible.

33 ADVANCED PROPULSION SYSTEMS↗

In Hot Water! The Challenges and Barriers of Decarbonizing Water Heating in Multifamily Buildings: Preprint

Domestic hot water heating is responsible for 32% of the total energy consumption in multifamily buildings and offers a significant decarbonization opportunity. An extensive market assessment was conducted to understand and document key technical and economic barriers to electrification of domestic water heating in multifamily buildings throughout the U.S. Through the program, 77 interviews were conducted to understand key market drivers and technical challenges associated with electrification of water heating systems in both retrofit and new construction scenarios. Interviewees encompassed a wide range of stakeholders in the ecosystem surrounding water heating systems, including suppliers, manufacturers, designers, owners, utilities, and developers. This paper documents key interview takeaways, including an extensive list of market barriers, technical challenges, and sought-after technology attributes that can inform pertinent design criteria for electric water heating research, development, and deployment efforts. Among economics and energy efficiency features, interviewees overwhelmingly alluded to space constraints, cold air exhaust, and lack of clear guidance regarding distributed versus centralized design selections as key challenges associated with mass adoption of electric water heating. Owners and developers seek systems with minimal footprint, which maximize rentable space and profits. Moreover, distributed heat pump solutions should balance ducting costs that mitigate cold exhaust entrainment into conditioned zones. Lastly, the market needs clear guidance regarding the selection of distributed versus central electric hot water systems.

challenges of water heating electrification↗

Analyzing at-scale distribution grid response to extreme temperatures

Threats against power grids continue to increase, as extreme weather conditions and natural disasters (extreme events) become more frequent. Hence, there is a need for the simulation and modeling of power grids to reflect realistic conditions during extreme events conditions, especially distribution systems. Herein, this paper presents a modeling and simulation platform for electric distribution grids which can estimate overall power demand during extreme weather conditions. The presented platform's efficacy is shown by demonstrating estimation of electrical demand for 1) Electricity Reliability Council of Texas (ERCOT) during winter storm Uri in 2021, and 2) alternative hypothetical scenarios of integrating Distributed Energy Resources (DERs), weatherization, and load electrification. In comparing to the actual demand served by ERCOT during the winter storm Uri of 2021, the proposed platform estimates approximately 34 GW of peak capacity deficit. These numbers are consistent with state-of-the-art prediction results published in the literature. For the case of the future electrification of heating loads, peak capacity of 78 GW (124% increase) is estimated, which would be reduced to 47 GW (38% increase) with the adoption of efficient heating appliances and improved thermal insulation. Integrating distributed solar PV and storage into the grid causes improvement in the local energy utilization and hence reduces the potential unmet energy by 31% and 40%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

Decarbonization pathways for the residential sector in the United States

We report residential GHG emissions in the United States are driven in part by a housing stock where onsite fossil combustion is common, home sizes are large by international standards, energy efficiency potential is large and electricity generation in many regions is GHG intensive. In this analysis, we assess decarbonization pathways for the US residential sector to 2060, through 108 scenarios describing housing stock evolution, new housing characteristics, renovation levels and clean electricity. The lowest emission pathways involve very rapid decarbonization of electricity supply alongside extensive renovations to existing homes, including improving thermal envelopes and heat pump electrification of heating. Reducing the size and increasing the electrification of new homes provide further emission cuts and combining all strategies enables reductions of 91% between 2020 and 2050. The potential of individual mitigation strategies shows great regional variation. Reaching zero emissions will require simultaneous deployment of multiple strategies and greater reduction of embodied emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Optimization of a Fast-Switching Electromagnetic Valve Actuator for Off-highway Vehicle Hydraulic Systems

Electrification of off-highway vehicles offers improved efficiency and reduction in greenhouse gas emissions. However, the extremely low power densities of electric machines relative to the hydraulics used in conventional off-highway vehicles makes electrification challenging. Although the recently proposed Hybrid Hydraulic Electric Architecture (HHEA) can overcome this limitation, it requires frequent switching between the pressure rails using switching valves resulting in losses. Fast switching minimizes the switching losses in these valves, which otherwise significantly reduce the overall efficiency of the system. The primary contribution of this paper is the design and optimization of a linear electromagnetic actuator for a fast-switching valve. This paper identifies the actuator requirements to enable fast switching and presents a design and optimization technique to realize actuators that meet the design objectives. In addition, a multi-physics approach is proposed to model the performance of the complete switching valve by considering the electromagnetic, fluidic, and mechanical physics. An optimal actuator design is obtained using the developed optimization framework, and the multi-physics model demonstrates that the selected design achieves a 30% reduction in throttling-related switching losses by switching 70 % faster than comparable commercial valve designs.

Linear actuators, off-highway vehicle electrificat↗