Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Speed estimates from grating patches are not contrast-normalized

We have previously shown that the perceived speed of a moving grating depends upon its contrast, with lower-contrast patterns appearing to move more slowly than otherwise identical higher-contrast patterns. To explain this finding while remaining consistent with the findings of McKee, Silverman and Nakayama [(1986) Vision Research, 26, 609-619], we proposed that this misperception might arise from a modified version of the contrast-normalization procedure, envisaged by Adelson and Bergen [(1986) The extraction of spatio-temporal energy in human and machine vision (pp. 135-139). Charleston, S.C.: IEEE Computer Society] as a necessary second stage of motion-energy models of human motion processing. Specifically, our previous results might be explained if the two gratings to be compared interfered with each other's normalization. To test this hypothesis we performed two experiments. Experiment 1 demonstrates that the contrast effects persist even when two grating patches to be compared are presented up to 5 sec apart so that they would not be expected to bias each other's normalization. Experiment 2 shows that the contrast effects are unchanged when the two grating patches are surrounded by a range of patterns whose contrast would be expected to interfere with any normalization process. These two results allow the rejection of the contrast-normalized motion-energy hypothesis as an explanation of human speed perception. We discuss the consequences of these results on models of speed processing in the human visual system.

NASA Center ARC↗

Carbon management technology pathways for reaching a U.S. Economy-Wide net-Zero emissions goal

The Carbon Management Study Group of the 37 th Energy Modeling Forum (EMF 37) designed seven scenarios to explore the role of three potentially key technology suites – point source carbon dioxide capture and storage (PSCCS), direct air capture of carbon dioxide (DACCS), and hydrogen systems (H 2 ) – in shaping the broader technology pathways to reaching net-zero carbon dioxide (CO 2 ) emissions in United States by 2050. Each scenario was run by up to 13 models participating in the EMF 37 study. Results show that carbon dioxide removal technologies were consistently a major part of successful pathways to net-zero U.S. CO 2 emissions in 2050. Achieving this net-zero CO 2 goal without any form of carbon dioxide capture and storage was found to be impossible for most models; some models also found it impossible to reach net-zero without DACCS. The marginal cost of achieving net-zero CO 2 emissions in 2050 was between two and 10 times higher without PSCCS and/or DACCS available. The carbon price at which DACCS was deployed as a backstop technology depended upon the assumed cost at which DACCS was available at scale. Carbon prices were between $\$$250 and $\$$500 per ton CO 2 when DACCS deployed as a backstop. The average CO 2 capture rate across all models in 2050 in the central net-zero scenario was 1.3 GtCO 2 /year, which implies a substantial upscaling of capacity to move and store CO 2 . Finally, hydrogen sensitivity scenarios showed that H 2 typically constituted a relatively small share of the overall U.S. energy system; however, H 2 deployed in applications that are considered hard to decarbonize, facilitating transition towards net-zero emissions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Solar energy market penetration models - Science or number mysticism

The forecast market potential of a solar technology is an important factor determining its R&D funding. Since solar energy market penetration models are the method used to forecast market potential, they have a pivotal role in a solar technology's development. This paper critiques the applicability of the most common solar energy market penetration models. It is argued that the assumptions underlying the foundations of rigorously developed models, or the absence of a reasonable foundation for the remaining models, restrict their applicability.

Warren, E. H., Jr.↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Polar cap models of gamma-ray pulsars: Emision from single poles of nearly aligned rotators

We compare a new Monte Carlo simulation of polar cap models for gamma-ray pulsars with observations of sources detected above 10 MeV by the Compton Observatory (CGRO). We find that for models in which the inclination of the magnetic axis is comparable to the angular radius of the polar cap, the radiation from a single cap may exhibit a pusle with either a single broad peak as in PSR 1706-44 and PSR 1055-52, or a doubly peaked profile comparable to those observed from the Crab, Vela and Geminga pulsars. In general, double pulses are seen by observers whose line of sight penetrates into the cap interior and are due to enhanced emission near the rim. For cascades induced by culvature radiation, increased rim emission occurs even when electrons are accelerated over the entire cap, since electrons from the interior escape along magnetic field lines with less curvature and hence emit less radiation. However, we obtain better fits to the duty cycles of observed profiles if we make the empirical assumption that acceleration occurs only near the rim. In either case, the model energy spectra are consistent with most of the observed sources. The beaming factors expected from nearly aligned rotators, based on standard estimates for the cap radius, imply that their luminosities need not be as large as in the case of orthogonal rotators. However, small beam angles are also a difficutly with this model because they imply low detection probablities. In either case the polar cap radius is a critical factor, and in this context we point out that plasma loading of the field lines should make the caps larger than the usual estimates based on pure dipole fields.

Daugherty, Joseph K.↗

Community Geothermal: Mechanical, Electrical, and Plumbing Design Report and Drawings - Wallingford, CT

Included here are the mechanical, electrical, and plumbing design report and drawings for the proposed community geothermal system at an affordable housing complex in Wallingford, Connecticut. The report and drawings were developed by LN Consulting, in partnership with the University of Connecticut, which completed the energy modeling that formed the basis of the design work. The drawings can be used as a basis for a Request for Proposals to procure entities to complete construction-ready design documents.

15 GEOTHERMAL ENERGY↗

Investigating Building Energy Consumption and CO2 Emission in Phoenix Using AutoBEM and Future Typical Meteorological Year (fTMY) Weather Data

This research investigates the energy performance and CO2 emissions of each building stock across the Phoenix metropolitan area using the Automatic Building Energy Modeling (AutoBEM) framework and Model America v2 (MAv2) dataset from Oak Ridge National Laboratory (ORNL). Typical Meteorological Year (TMY) and Future Typical Meteorological Year (fTMY) files were used for AutoBEM simulation. The simulation results from TMY and fTMY were compared. It was found that a projected 10.28% increase in total CO2 emissions and a 9.30% rise in total energy consumption by 2080–2099 relative to current typical conditions. The results highlight the disparities in emissions among different building stocks and the influence of climate change on future energy demand. The findings underscore the necessity of targeted policy interventions and retrofitting strategies (eg. advanced HVAC systems, improved insulation, reflective roofing) to mitigate emissions in high-energy-use and emission-intensed buildings, particularly as climate conditions evolve. This study contributes to the growing understanding of building-sector emissions and their long-term implications under future climate scenarios.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

TEAMER: Crossflow Turbine Fairing Geometry Optimization - Report and CFD Modeling Files

The dataset includes computational fluid dynamics (CFD) models and simulation files for crossflow turbines as well as a detailed project report. The report documents the project undertaken by the Ocean Renewable Power Company (ORPC) to design and optimize a modular fairing for the Modular RivGen Marine Hydrokinetic (MHK) turbine, which enhances the efficient deployment and operation of turbine arrays. The project focused on optimizing the hydrodynamic performance of the fairing using CFD, with an emphasis on two key geometric parameters: the fairing's cross-sectional shape and the spacing between the rotor and the fairing. The analysis aimed to maximize net power output while also assessing discretized loading to evaluate ultimate and fatigue loads on the turbine components. The numerical modeling was conducted using both the commercial CFD software Star-CCM+ and the open-source code openFOAM, with the latter utilizing the actuator line library, turbinesFOAM. This dual-code approach was intended to increase confidence in the results and demonstrate the viability of using open-source tools for high-fidelity marine energy modeling. This dataset includes all necessary files for actuator line simulations in openFOAM, as well as 2D blade-resolved CFD results, along with Python and Java scripts for setting up and post-processing simulations.

16 TIDAL AND WAVE POWER↗

Machine Learning based Aircraft Performance Model Estimation for Trajectory Prediction

The accurate prediction of aircraft trajectory by ground-based decision support tools is a critical component of air traffic management in the US National Airspace System (NAS). Accurate predictions of where the aircraft will be in the future or when they will arrive at specific locations (e.g., fixes) is a key enabler for sequencing and efficient arrival management of flights. Traditional physics based aircraft trajectory prediction relies on a simplified point-mass total energy model whose parameters are referred to as Aircraft Performance Model (APM) parameters. Even though the performance coefficients and weight of an aircraft are a vital part of the aircraft performance model’s predictions and accuracy, these coefficients are proprietary in nature and therefore, unavailable to decision-support tools. Current approaches freeze some coefficients to default base of aircraft data (BADA) values and optimize others. However, the APM parameters are highly coupled by the flight dynamics and prioritizing one parameter over others leads to bias and skewed predictions. To alleviate this problem, we provide a combined optimization framework to predict all the critical (thrust, drag and weight) APM parameters. This paper is focused on training Machine Learning (ML) models that map historical flights to optimized APM parameters that provide the best fit (in terms of prediction error). Our dataset obtained from NASA’s Sherlock data warehouse is comprised of thousands of historical flights and includes weather and track data collected from 2019. Using different subsets of relevant features (e.g., aircraft type), we trained several ML models to estimate the aircraft’s take off weight, drag polar coefficients (both parasitic and lift induced), and thrust settings (multiplier applied to the maximum engine thrust). The chosen flights are from three of the most common aircraft types (B738, B737, and A320) arriving at four airports (LAX, DEN, MSP, and DFW). Our ML approach is comprised of two different solutions: 1- using a subset of features that are known prior to the flight departure and do not change during flight (such as engine type, current temperature at departure & destination airports, aircraft type) and 2 - using a subset of temporal features of the flight trajectory (such as cruise altitude, Mach, airspeed, and rate of climb) in addition to the pre-departure features from the first solution. The labels or target variables are the APM parameters that were obtained by an optimized ordinary differential equations (ODE) fitting process (applied to individual flights). The ODE-fitting is very time intensive and is therefore performed offline. Thus, training an ML model to learn the relationship between the flight features and ODE-generated labels enables faster estimation of the APM parameters and is therefore amenable to real-time prediction. Various ML models including linear regression, random forest, XGBoost, and neural network were trained, and the results are compared. After model validation and hyperparameter-tuning, we observed that the Random Forest model outperformed the other three models by the overall mean square error (MSE) of 2% for the first solution and 1.5% for the second solution. Finally, the ML-derived parameters are compared against default BADA APM parameters using NASA’s Autonomy Development toolkit (ADK) simulation software. The simulation results for one of each aircraft type is shown and discussed.

Aida Sharif Rohani↗

Powered by dsgrid [Slides]

NREL's demand-side grid (dsgrid) toolkit harnesses decades of sector-specific energy modeling expertise to understand current and future U.S. electricity load for power systems analyses. The primary purpose of dsgrid is to create comprehensive electricity load data sets at high temporal, geographic, sectoral, and end-use resolution. These data sets enable detailed analyses of current patterns and future projections of end-use loads. This presentation will include NREL power grid researcher Elaine Hale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Background Count Rates and the Anti-Coincidence Detector on the Instrument on Astro-E2

Minimum ionizing particles incident on the XRS microcalorimeter array will deposit energy in the pixels on the same scale as an x-ray photon and would be confused with x-rays without an anti-coincidence detector. The XRS anti-coincidence detector is a silicon ionization detector placed directly behind the calorimeter array. Given an isotropic particle flux, 98% of those particles that pass through a calorimeter pixel will also deposit energy in the anti-coincidence detector. Particle events that are not rejected by coincidence are those that pass through at small angles relative to the plane of the array, and thus deposit more energy. Modeling with GEANT4 showed that only 0.1% of all protons incident on the array miss the anti-coincidence detector yet deposit less than 10 keV in a pixel. The unrejected background will thus be dominated by secondary events; we will provide an estimate of this rate. Protons incident on the thick silicon frame around the active area of the array deposit enough energy t o heat the whole chip slightly. This results in small simultaneous pulses on multiple pixels. These can be easily rejected by pixel-to-pixel coincidence. We will discuss the impact of these events on the instrument dead time and will present the expected rate. We will present laboratory background data demonstrating the performance of the anti-coincidence detector and the effectiveness of coincidence analysis in the laboratory environment.

Kilbourne, C. A.↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strong Correlation DMRG and DFT

This project developed new ways to improve computer simulations of materials where electrons interact strongly with each other, a challenge for today’s most widely used method, density functional theory (DFT). We used an exact numerical method, the density matrix renormalization group (DMRG), to create highly accurate reference results for simple model systems, and used these to test DFT, prove when it will converge, and even train machine-learned functionals. We also invented new kinds of localized basis functions (“gausslets” and “multi-sliced gausslets”) and a “sliced-basis” approach that make high-accuracy simulations faster and more practical. These methods were applied to extended hydrogen systems, enabling the direct derivation of accurate low-energy models from first-principles calculations. We also introduced a new formalism, Conditional-Probability DFT, which could bypass traditional approximations. The tools and results from this work, including open-source software releases, will help scientists design and understand complex quantum materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structure prediction of porous organic crystals

In this work, we explore the possibility of applying automated crystal structure prediction to reproduce the experimentally identified metastable porous polymorphs. Using our recently developed High-Throughput Organic Crystal Structure Prediction ( HTOCSP ) framework, we conducted a systematic study on five representative organic crystalline systems including hydrogen-bonded frameworks (HOFs), featured by the presence of significant porosity, in conjunction with different choices of energy models from classical, machine learning force fields, tight binding to density functional theory. Our results suggest that the current structure generation framework, with careful selection of symmetry conditions, is likely to generate rather complex and abundant metastable crystal candidates for porous crystals. In conjunction with the recent advance in universal machine learning force fields, it becomes possible to identify experimental structures as the energetically favorable candidates from a simple energy versus density analysis, thus paving the way for computational design of complex porous materials with the target systems prior to the experimental synthesis and characterization.

36 MATERIALS SCIENCE↗

Net Zero World 2024 Achievements

Net Zero World, launched at COP26, aims to expedite the transition to clean energy systems worldwide. This report details Net Zero World's achievements in 2024. Leveraging expertise from ten U.S. Department of Energy national laboratories and nine federal agencies, Net Zero World has provided specialized technical support and energy modeling to eight partner countries: Argentina, Chile, Egypt, Indonesia, Nigeria, Singapore, Thailand, and Ukraine.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Novel Standard Gibbs Energy of Formation Model for High-Enthalpy Water Systems

This work provides an advanced standard molar Gibbs energy of formation model, informed by molecular statistical thermodynamics (MST), and validated by mineral solubility and ion association reactions. This new model aligns with experimental data within uncertainties and highlights the role of specific MST interactions around the critical point. This work will provide a reliable tool for the optimization of industrial processes operating at the edges of the supercritical domain.

Hall, Derek↗

Wasserstein Normalized Autoencoder for Anomaly Detection in ProtoDUNE Vertical-Drift Detector

ProtoDUNE Vertical Drift needs a selective triggering algorithm. The detector sits on Earth's surface, so cosmic activity dominates its data. Our goal in this paper is to trigger on neutrino events more robustly than the current deployed Analog-to-Digital Converter Simple Window (ADCSW) model and, eventually, search for signals of Beyond Standard Model (BSM) physics at DUNE as our ultimate North Star objective. As a step towards this goal, we evaluate a Wasserstein Normalized Autoencoder (WNAE) on simulated collection-plane only windows of shape $1\times10\times10$ where Neutrinos act as our BSM-proxy and Cosmic-ray Muons serve as our learned background. The network parameters are fitted using only cosmic-ray muon events as background in order to maintain an unsupervised pipeline. Training uses finite-step Langevin $x^-$ samples, positive-sample reconstruction energy, and an empirical sliced $2$-Wasserstein objective to learn a normalized Boltzmann energy model. We then calibrate on a nominal $5\,\mathrm{Hz}$ operating threshold calculated from cosmic validation data. Both WNAE and ADCSW accept 311 of 194,083 held-out cosmic background events at this $5\,\mathrm{Hz}$ threshold. We found that WNAE accepts 9,677 of 34,634 neutrino-proxy events $(27.9\pm0.24)\%$, compared with 10,076 $(29.1\pm0.24)\%$ for ADCSW, an observed WNAE-minus-ADCSW difference of $-1.15\%$. At another nominal $2\,\mathrm{Hz}$ target threshold, the corresponding efficiencies are $(20.5\pm0.22)\%$ and $(22.6\pm0.22)\%$, respectively. Of the WNAE-selected neutrino proxies at $5\,\mathrm{Hz}$, $(20.8\pm0.4)\%$ of the classified neutrino-proxy events are unique to WNAE, where the uncertainty is an absolute binomial standard error of $0.4\%$.

Zheng, Jake [U. Chicago (main)] (ORCID:00090002189↗