ComStock Measure Documentation: Thermostat Setbacks During Unoccupied Periods

This report assesses the potential for nationwide adoption of thermostat setbacks in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario— Thermostat Setbacks During Unoccupied Periods—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use cases (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Analysis of ASHRAE Standard 90.1-2019

This article summarizes the analysis conducted by Pacific Northwest National Laboratory (PNNL), assessing expected end-use energy consumption in commercial buildings, based on recent editions of the model energy code for the commercial sector, ANSI/ASHRAE/IES Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings. The results represent simulated energy use based on) Commercial Prototype Building Models1 across representative climate zones in the United States, as defined by Standard 90.1. PNNL examined the resulting simulation outputs to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Preliminary Study of a Novel Heat Pump Integrated Underground Thermal Energy Storage for Shaping Electric Demand of Buildings

A Dual-Purpose Underground Thermal Battery (DPUTB) innovatively integrates a ground heat exchanger with underground thermal energy storage. The DPUTB can be integrated with an Electric-Driven Heat Pump (EDHP) to enable more flexible electric load for meeting the thermal demands of a building (e.g., space cooling and space heating). A one-dimensional numerical model of the DPUTB is developed and validated against measured performance data of a small-scale DPUTB prototype. The validated DPUTB model is integrated with a heat pump model and a building energy simulation model to predict the load shifting performance and energy consumption of an integrated EDHP and DPUTB system. Preliminary simulation results indicate that the integrated system can flatten the electric load profile of a typical residential building and reduce the electric demand during peak hours by 37% on a typical summer day. In addition, the integrated EDHP and DPUTB system also reduces the daily power consumption of the building by 11% compared with a conventional residential space heating and cooling system.

Liu, Xiaobing↗

Lifting the Garage Door on Spawn, An Open-Source BEM-Controls Engine

Spawn is the latest whole-building energy simulation engine developed by the US Department of Energy, National Labs and industry. Whereas EnergyPlus was designed as a successor to DOE-2, Spawn is not a direct successor of–nor is it intended as an imminent replacement for– EnergyPlus. Instead, Spawn reuses parts of EnergyPlus while supporting new use cases in HVAC and controls. Spawn is intended to provide several capabilities that significantly advance beyond EnergyPlus. It is intended to support the evaluation of novel HVAC and district energy systems in a more physically realistic way. Critically, it can model control in a physically realistic way, using portable specifications that can be compiled for execution on control platforms. Spawn is also intended to support co-simulation in an intrinsic way to enable integration with third-party models. This paper describes the software architecture of Spawn from model authoring to compilation and simulation. It explains how Spawn reuses the envelope and daylighting modules of EnergyPlus and couples them to HVAC and control models from the Modelica Buildings Library using the Functional Mockup Interface (FMI) standard. It presents a number of examples that: i) validate Spawn’s coupled simulation approach by comparing its results to those of EnergyPlus, ii) illustrate the Spawn methodology for modeling and simulating HVAC systems, and iii) evaluate the performance of Spawn’s Quantized State System (QSS) time integration algorithms

Wetter, Michael↗

Coupling Mesoscale Budget Components to Large-Eddy Simulations for Wind-Energy Applications

To simulate the airflow through a wind farm across a wide range of atmospheric conditions, microscale models (e.g., large-eddy simulation, LES, models) have to be coupled with mesoscale models, because microscale models lack the atmospheric physical processes to represent time-varying local forcing. Here we couple mesoscale model outputs to a LES solver by applying mesoscale momentum- and temperature-budget components from the Weather Research and Forecasting model to the governing equations of the Simulator fOr Wind Farm Applications model. We test whether averaging the budget components affects the LES results with regard to quantities of interest to wind energy. Our study focuses on flat terrain during a quiescent diurnal cycle. The simulation results are compared with observations from a 200-m tall meteorological tower and a wind-profiling radar, by analyzing time series, profiles, rotor-averaged quantities, and spectra. However, while results show that averaging reduces the spatio-temporal variability of the mesoscale momentum-budget components, when coupled with the LES model, the mesoscale bias (in comparison with observations of wind speed and direction, and potential temperature) is not reduced. In contrast, the LES technique can correct for shear and veer. In both cases, however, averaging the budget components shows no significant impact on the mean flow quantities in the microscale and is not necessary when coupling mesocale budget components to the LES model.

17 WIND ENERGY↗

EnergyPlus Interior Radiant Heat Exchange Runtime Performance Improvements

EnergyPlus is the flagship whole-building energy simulation program developed by the US Department of Energy. This paper describes the various approaches to improve the performance of the interior radiant heat exchange algorithm. Vectorization, optimized Basic Linear Algebra Subprograms (BLAS) library, multithreading, and Graphical Processing Unit (GPU) computation are all investigated. The approach with the best performance, while maintaining drop-in compatibility with existing EnergyPlus code, is the optimized BLAS library. However, GPU computing has the potential to reduce simulation time by orders of magnitude with major refactoring to EnergyPlus.

Adams, Mark↗

Development of a simplified calibrated building simulation model of a supermarket for proposed ECMs and control strategies impact evaluation

Calibrated building energy simulation is an important pathway to more energy-efficient buildings, but the information requirements of some approaches to this problem are significant. This is particularly true for supermarkets and other so-called “big-box” retail stores. Another characteristic of supermarkets is the significant interaction between Heating Ventilating and Air Conditioning (HVAC) and refrigeration systems in these buildings. These buildings could contain a wide variety of systems and a degree of load diversity that makes calibrated modeling a challenge. This paper describes a simplified approach that uses OpenStudio and EnergyPlus to combine known building parameters with “typical” parameters, resulting in a simplified building that is amenable to calibration. This approach was applied to a big-box store located in Nashville, Tennessee, and a calibrated model was obtained that was used to study potential energy conservation measures. Further, the paper also explores the capabilities of whole-building energy modeling tools, such as EnergyPlus, for modeling the HVAC controls and sequences and their impact evaluation. Although some measures are precluded by the model simplicity, several measures were found to improve the efficiency of the model and demonstrate that the simplified modeling approach is effective. Practical Application: This paper introduces a hybrid approach of building energy model calibration using limited information available from the actual building in combination with characteristics of a “typical” building of the same type. This hybrid approach would also be applicable for other building types than discussed in this paper to calibrate the building energy model using limited information from the actual building.

42 ENGINEERING↗

Probabilistic reliability assessment and case studies for predicted energy savings in residential buildings

This study aims to (1) investigate the key influential parameters (KIPs) in estimating the uncertainty of energy savings using a residential building energy simulation model and (2) perform uncertainty quantification for energy savings for several different scenarios. The proposed methodology was successfully applied to the calculation of uncertainties associated with residential energy retrofits using two test houses designed for pre- and post-retrofit cases. Uncertainties were determined using basic parameters that might be supplied to an energy model and then reevaluated based on an audit of the KIPs identified, resulting in substantially reduced uncertainty. Of four different scenarios, the most uncertain scenario estimated the annual energy savings from the retrofit would be between 18% and 51% at a 95% confidence level, and the least uncertain scenario estimated the annual savings would be between 26% and 40% at a 95% confidence level. The actual measured annual savings from the two test houses was 28%, which shows an agreement with the uncertainty analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptation of fan motor and VFD efficiency correlations using Bayesian inference

Energy performance contracts (EPC) are types of agreements in which a service provider guarantees that customers’ buildings will achieve a specified energy performance (i.e., minimum energy savings) to reduce the risk of their investment in energy efficiency improvements. EPC requires prediction of future energy consumption of the building, at the design stage, before construction or major retrofit. To this end, building energy simulations taking into account all the major energy-using components are performed. In particular, fans can contribute significantly to the total building consumption. The overall efficiency of fans is the combination of three factors: mechanical, motor, and variable frequency drive (VFD). Manufacturers usually provide fan mechanical efficiency curves for a broad operating range. In contrast, motor and VFD efficiencies are generally given at rating conditions only. To represent part-load conditions, correlations are typically used to estimate motor and VFD efficiency variations, to evaluate the overall electricity consumption. The first aim of this study is to evaluate existing correlations for motor and VFD efficiency as a function of load and speed, by comparison with manufacturer data, for a vendor that has shared its detailed test data. While VFD efficiency correlations from the literature provide reasonable accuracy against real data, motor correlations under predict actual motor efficiency at low loads. Finally, the second aim of the paper is to improve such correlations using Bayesian inference to fit the available data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Reference Documentation (V.1)

The commercial building sector stock model, or ComStock™, is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. ComStock asks and answers two questions: how is energy used in the U.S. building stock and what are the impact of energy saving technologies. Specifically, ComStock identifies where energy is being consumed geographically, in what building types and end uses, and at what times of day. Simultaneously, it identifies the impact of efficiency measures: how much energy do efficiency measures save; where, or in what use cases do measures save energy; when, or at what time of day do savings occur; and which building stock segments have the biggest savings potential. This document contains the methodology and assumptions behind ComStock and serves as a guide to its use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying Uncertainties in Earth's Energy Budget by Cloud Feedback and Ocean Heat Uptake Using E3SM-Slab Ocean Configurations

In order to improve predictive skills of Earth System Model, we need to better understand processes that control Earth's energy budget via ocean, atmosphere, and cryosphere interactions. Simulated energy budget in comprehensive Earth System Models shows a wide range, leading to large uncertainties in predicting Earth system dynamic and thermodynamic variations and associated social-economic impacts. Uncertainties in cloud feedbacks have been identified as the main cause of the large inter-model spread, but oceanic adjustments, especially those associated with ocean heat uptake (OHU) and the Atlantic Meridional Overturning Circulation (AMOC), also play an important role. In this proposed work, we focus on understanding the individual and combined roles of cloud feedbacks and ocean adjustments on modulating Earth's energy balance. This research is motivated by our overarching hypothesis that oceanic adjustment is a key source of uncertainty, in addition to those associated with the cloud feedbacks; further, the ocean adjustment and associated OHU work through the cloud feedbacks to modulate Earth's energy budget and temperature variations. We test this hypothesis using numerical experiments where we systematically enable and disable cloud feedbacks in conjunction with perturbations to OHU.

58 GEOSCIENCES↗

EnergyPlus Performance Improvements via JSON Input Refactoring

EnergyPlus is the flagship whole-building energy simulation program developed by the U.S. Department of Energy. This paper describes the refactoring efforts around the EnergyPlus input processor to natively support JavaScript Object Notation (JSON), allow validation through use of a JSON schema validator, convert and validate typical EnergyPlus input data file (*.idf) files to JSON files, and improve related metrics such as: read time for schema and input files, parse time for processing input, and time to query/return data from EnergyPlus internal data structure. Performance improvements on sample files result in 14% and 60% reduction in schema and input file reads respectively, 36-62% reduction to process input, and 24-99+% query reduction for functions that take advantage of the new format. For the files tested, overall speedup realized as part of this JSON refactor is 1.6x to 5.4x.

Adams, Mark↗

Performance evaluation of radiant cooling system integrated with air system under different operational strategies

The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building using a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. Lastly, the energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bias Correction in Urban Building Energy Modeling for Chicago Using Machine Learning

Urban-scale building energy modeling (UBEM) holds promise for optimizing energy usage across extensive geographic regions. However, there is a recognized bias between simulated energy consumption and actual measured data. This study, based on building data from Chicago, delved into bias correction techniques for enhancing the accuracy of UBEM energy consumption estimates. Initially, the AutoBEM simulation yielded a normalized mean bias error (NMBE) of 1.1% and 51% of Coefficient of the Variation of the Root Mean Square Error (CVRMSE) after outlier exclusion. To address this, three bias correction methods were deployed: Average Mean Bias Error based bias correction, Quantile mapping bias correction, and Machine learning-based bias correction using Linear Regression and Random Forest models. Post-correction results exhibited marked improvement. The NMBE values were diminished to 0 for Average MBE-based, 0.36 for Quantile Mapping, and 0 for Machine Learning-based corrections. Concurrently, the CVRMSE values registered reductions from an original 51 to 50.8 for Quantile Mapping, and 38.56 for Machine Learning-based corrections, pointing towards the effectiveness of specific bias correction methods in refining the precision of UBEM energy predictions. Such accurate estimations are paramount for informed energy planning and urban policy-making.

Chowdhury, Shovan↗

Multifamily Tool for Energy Audits (MulTEA) Engineering Manual (Version 1)

The Multifamily Tool for Energy Audits (MulTEA) is an energy audit tool designed to provide auditors with an improved energy simulation tool for multifamily buildings and an improved tool for identifying cost-effective energy-efficiency retrofit measures for multifamily buildings. MulTEA is designed specifically to help states and local weatherization agencies implement the Department of Energy (DOE) Weatherization Assistance Program. MulTEA was developed jointly by the Oak Ridge National Laboratory (ORNL) and the Lawrence Berkeley National Laboratory (LBNL). MulTEA is part of ORNL’s web-based Weatherization Assistant suite of audit tools (https://weatherization.ornl.gov/softwaredescription/). The energy calculation engine including the DOE- 2 simulation model and supplementary calculation modules is shared by MulTEA and LBNL’s Home Energy Saver pro (HESpro) (http://hespro.lbl.gov/pro/). On the ORNL side, the energy calculation engine is coupled with a user interface and output reporting capabilities based on Weatherization Assistance Program regulations and guidelines pertinent to MulTEA. On the LBNL side, the same engine will be used in HESpro to expand it to handle multifamily buildings. MulTEA is designed to address small and large multifamily buildings with decentralized and centralized heating, ventilation, and air-conditioning (HVAC) and domestic hot water (DHW) systems. Version 1 of MulTEA addresses small multifamily buildings with decentralized HVAC systems, and decentralized or centralized DHW systems. The capability to model large buildings and centralized HVAC systems will be incorporated in Version 2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Statistical Analysis and Modeling of Occupancy Patterns in Open-Plan Offices using Measured Lighting-Switch Data

Occupancy profile is one of the driving factors behind discrepancies between the measured and simulated energy consumption of buildings. The frequencies of occupants leaving their offices and the corresponding durations of absences have significant impact on energy use and the operational controls of buildings. This study used statistical methods to analyze the occupancy status, based on measured lighting-switch data in five-minute intervals, for a total of 200 open-plan (cubicle) offices. Five typical occupancy patterns were identified based on the average daily 24-hour profiles of the presence of occupants in their cubicles. These statistical patterns were represented by a one-square curve, a one-valley curve, a two-valley curve, a variable curve, and a flat curve. The key parameters that define the occupancy model are the average occupancy profile together with probability distributions of absence duration, and the number of times an occupant is absent from the cubicle. The statistical results also reveal that the number of absence occurrences decreases as total daily presence hours decrease, and the duration of absence from the cubicle decreases as the frequency of absence increases. The developed occupancy model captures the stochastic nature of occupants moving in and out of cubicles, and can be used to generate a more realistic occupancy schedule. This is crucial for improving the evaluation of the energy saving potential of occupancy based technologies and controls using building simulations. Finally, to demonstrate the use of the occupancy model, weekday occupant schedules were generated and discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Open-Source Integrated Design-Analysis Environment For Nuclear Energy Advanced Modeling & Simulation Final Scientific/Technical Report

The framework created through the Open-Source Integrated Design-Analysis Environment (IDAE) for Nuclear Energy Advanced Modeling & Simulation grant has simplify and democratize advanced modeling and simulation in the nuclear energy industry that works on a range of nuclear engineering applications. It leverages millions of investment dollars from the Department of Energy's Office of Nuclear Energy for modeling and simulation of light water reactors and the Office of Nuclear Energy's research and development. The IDEA framework enhanced Kitware’s Computational Model Builder (CMB) while leveraging existing open-source toolkits and creating a graphical end-to-end umbrella guiding end-users and developers through the nuclear energy advanced modeling and simulation lifecycle. In addition, the work deliver strategic advancements in meshing and visualization for ensembles.