Search NASA⌕ Search

SEARCH · Search NASA

Results for “Equipment Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Refining seasonal performance metrics for room air-conditioning in emerging markets: Integrating building simulations with real-world equipment performance data

Buildings significantly impact worldwide energy consumption, emphasizing the need to reduce the cooling energy demand, especially in warm climates. Minimum energy performance standards (MEPS) and seasonal performance metrics such as the Cooling Seasonal Performance Factor (CSPF) are crucial for improving room air conditioning (RAC) efficiency. However, challenges remain, particularly in emerging markets like Brazil, where seasonal performance metrics have recently been introduced. This study assesses the factors influencing country-level seasonal efficiency metrics and proposes a framework to refine these calculations by considering local climates and expected RAC usage in real-world households via building simulations. Key considerations include outdoor air temperature binning for different climates, RAC usage patterns (i.e., daytime and nighttime usages), envelope thermal performance of households, and urban heat island (UHI) effects. The results reveal that CSPF values can vary significantly based on climate conditions, with observed CSPF ranging from 4.10 to 11.59 Wh/Wh across 577 Brazilian climates. The inclusion of UHI effects led to a reduction in CSPF values by up to 29% during nighttime operations in hot urban areas. Additionally, building envelope efficiency showed contrasting impacts on RAC performance, with CSPFs reaching up to 15.35 Wh/Wh under specific optimized conditions. These findings highlight the need for transparent policymaking in RAC performance databases, facilitating the application of approaches like those proposed in this study and supporting diverse stakeholders in decision-making.

Bavaresco, Mateus↗

A critical review of cyber-physical security for building automation systems

Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.

97 MATHEMATICS AND COMPUTING↗

Validation of Power Distribution Models using Load Flow Analysis in an ADMS Environment

Electric utilities are facing the need for better monitoring, analysis, and control of their distribution systems. An accurate mathematical model is a key to both the development of cutting-edge, scalable model-based algorithms and the assessment of emerging technologies such as distributed energy resources (DER) for grid planning and operation. However, the constantly evolving nature of power distribution systems poses challenges to maintaining accurate models. In this paper, we propose a novel load flow based approach to validate power distribution models. Networked equipment models described according to the Common Information Model (CIM) standard and a measurement model are used to formulate the distribution load flow problem. First, a system admittance matrix (Ybus) is derived from device-level CIM parameters. Next, the operational parameters (dynamic Ybus and nodal injections) are extracted from the measurement model using sensor configuration and equipment state. An iterative power flow method is then used to compute nodal voltages and branch flows that are compared against the measurement data to find any inconsistencies in the networked equipment model. This approach is implemented within GridAPPS-D, an open-source standards-based platform for advanced distribution management system (ADMS) application development, and demonstrated on the IEEE 13-bus, 123-bus, and 8500-node test feeders.

Common information model, model validation, power ↗

Technoeconomic Analysis of Kraft Pulp Mill Integration with an Advanced Nuclear Reactor

This study focuses on post-combustion capture and oxy-fuel combustion for the boilers at the mill, as well as steam integration with the nuclear power plant. The primary goal of the research outlined in this report is to design, analyze, and document the integration of industrial-scale HTGR with a reference Kraft Pulp Mill. The purpose is to deliver reliable, cost-effective, and sustainable clean energy alternatives while reducing CO2 emissions. Specifically, this study focuses on 6 different scenarios that include carbon capture equipment and some of them use nuclear power to meet the heat and electricity needs of the reference plant. Also, 2 of these scenarios are created while also producing clean hydrogen through integrated High-Temperature Steam Electrolysis (HTSE). This report offers a detailed techno-economic assessment of different scenarios for a Kraft Pulp Mill, including an analysis of tax credits (section 45V, 45Q, and 48E) provided by the Inflation Reduction Act (IRA) of 2022. The evaluation explores the potential economic benefits and challenges of incorporating different configurations, including nuclear energy, into Kraft Pulp Mill operations, with particular attention to energy efficiency, economic implications, and environmental impact. By assessing both the technical feasibility and economic viability, this analysis aims to identify existing gaps and propose solutions for the successful implementation of nuclear integration. The findings are intended to provide valuable insights for stakeholders considering the adoption of advanced nuclear reactors in the pulp and paper industries.

08 HYDROGEN↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Governance

Cybersecurity governance helps an organization detect, prevent, and respond to cyber incidents by establishing cybersecurity policies and procedures for use across the enterprise. As modern energy systems become increasingly reliant on smaller and decentralized generation sources-equipped with complex, data-driven communications-governance will be of growing importance for the continued protection of the electric grid. This presentation sheds light on the important aspects of cybersecurity governance, best practices to ensure a culture of cybersecurity, and approaches to frequent monitoring and assessment of an organization's cybersecurity posture.

business requirements↗

A Methodology to Evaluate the Grid Reliability Impact of Oscillations Induced by Large Loads

The rapid growth of hyperscale AI data centers is bringing renewed attention to the reliability risk that sustained forced oscillations pose to bulk power systems, with cyclic computational workloads emerging as a new forcing source. Unlike the broadband, stochastic disturbances from traditional industrial loads such as arc furnaces, AI training and inference facilities can inject large active power swings concentrated at specific frequencies over extended durations - characteristics that existing grid planning practices do not account for. While the North American Electric Reliability Corporation (NERC) has recognized this gap and called for system-level studies of large load interconnections, no standardized methodology exists to screen, simulate, and quantify these risks at the planning stage. This report presents the Risk Assessment Tool for Large Load-induced Events (RATLLE), a Python-based, publicly available script suite developed at the Pacific Northwest National Laboratory to evaluate bulk power system reliability risks from data center-induced oscillations. RATLLE implements a three-module workflow: a screening module that identifies vulnerable interconnection locations and excitable system modes; a simulation module that models cyclic data center load behavior using a commercial positive sequence simulation platform; and an analysis module that computes risk metrics and generates interactive visualization dashboards. The risk metrics, formulated around simulation observables, map oscillation impacts to a three-stage severity scale spanning latent equipment fatigue through imminent cascading failure. The methodology is demonstrated on two Western Electricity Coordinating Council (WECC) system models: a publicly available 240-bus reduced representation and a detailed 2031 Heavy Winter planning case. Case studies illustrate that even modest 50 MW forced oscillations at resonant frequencies can produce wide-area power swings, N-1 security constraint violations, and cascading generator trips through protection actions - outcomes that would not occur under normal operating conditions without oscillations present. The results underscore the need for standardized oscillation impact assessment in large load interconnection studies and provide a reproducible, extensible framework for utilities to adopt or customize within their existing planning workflows.

Biswas, Shuchismita↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Role of Hydrogen as Fuel in Decarbonizing US Clinker Manufacturing for Cement Production: Costs and CO2 Emissions Reduction Potentials

As a low-carbon fuel, feedstock, and energy source, hydrogen is expected to play a vital role in the decarbonization of high-temperature process heat during the pyroprocessing steps of clinker production in cement manufacturing. However, to accurately assess its potential for reducing CO2 emissions and the associated costs in clinker production applications, a techno-economic analysis and a study of facility-level CO2 emissions are necessary. Assuming that up to 20% hydrogen can be blended in clinker fuel mix without significant changes in equipment configuration, this study evaluates the potential reduction in CO2 emissions (scopes 1 and 2) and cost implications when replacing current carbon-intensive fuels with hydrogen. Using the direct energy substitution method, we developed an Excel-based model of clinker production, considering different hydrogen–blend scenarios. Hydrogen from steam methane reformer (gray) and renewable-based electrolysis (green) are considered as sources of hydrogen fuel for blend scenarios of 5%–20%. Metrics such as the cost of cement production, facility-level CO2 emissions, and cost of CO2 avoided were computed. Results show that for hydrogen blends (gray or green) between 5% and 20%, the cost of cement increases by 0.6% to 16%, with only a 0.4% to 6% reduction in CO2 emissions. When the cost of CO2 avoided was computed, the extra cost required to reduce CO2 emissions is $229 to $358/ metric ton CO2. In summary, although green hydrogen shows promise as a low-carbon fuel, its adoption for decarbonizing clinker production is currently impeded by costs.

Okeke, Ikenna J.↗

Retrospective on decadal progress of the NOAA/NPS ocean noise reference station network

The National Oceanic and Atmospheric Administration (NOAA), in partnership with the U.S. National Park Service (NPS), established the Ocean Noise Reference Station Network (NRS) in 2014 as a foundational component of NOAA’s Ocean Noise Strategy. This long-term effort aims to characterize baseline ocean ambient sound conditions across diverse marine environments and to inform management of noise impacts on protected species and habitats within U.S. waters. The NRS is now composed of 13 autonomous passive acoustic monitoring stations strategically positioned across the U.S. Exclusive Economic Zone (EEZ), extending from Arctic regions to tropical waters in depths ranging from 33 to 4,790 m. These locations include several National Marine Sanctuaries and National Parks, such as the recently designated Chumash Heritage National Marine Sanctuary off the coast of California. Each station is equipped to continuously sample low-frequency underwater sound at five kHz, enabling the detection of anthropogenic, geophysical, and biological acoustic signals. To date the network has sampled over 72 years of calibrated acoustic data. The spatial breadth and consistent methodology of the NRS allow for comparative acoustic assessments across diverse marine ecosystems. In addition to applied research functions, the NRS has served as a platform for education and training, offering opportunities for students to develop skills for marine science and data analysis. Looking forward, the NRS project team is focused on network expansion, improved data delivery, and broader integration with collaborative scientific initiatives. NRS recordings are being archived in partnership with NOAA’s National Centers for Environmental Information to enhance accessibility and long-term utility. Efforts are underway to develop standardized metadata and summary products to accompany raw audio files, making the data more usable for a wide range of stakeholders in the ocean science community. The NRS is evolving into a fully integrated national framework for ocean sound monitoring that supports scientific inquiry, management decision-making, national security interests, and public engagement with ocean acoustic environments.

Long-term monitoring↗

The Role of Innovation in the Circularity of EV Lithium-Ion Batteries

This case study analysis highlights the role of innovations in EV battery design (cells, modules, and packs), reverse supply chain, and recycling processes in yielding value for the economics of recycling (and have the largest impact on the circularity of LIBs). Part of the assessment of value will be a semi-quantitative evaluation of the value of resilience in the rapidly evolving LIB market – i.e., there are a variety of risks that recyclers would face in making a financial commitment to a recycling facility including; the possibility that batteries would not be collected in sufficient quantities, the market for key constituents (e.g., cobalt) might decrease because of changes in battery chemistry, battery manufacturers may not be willing to pay as much for recycled material, etc. The analysis would be semi-quantitative in that two simple models would be used to assess 1. material flows using a previously developed excel-based reverse supply chain flows model, and 2. A LIB recycling process material and energy balance cost model that will be used to qualitatively assess the cost impacts of process innovations and changes in feed streams. Both sets of models are highly speculative in that they rely on a multitude of assumptions and input values (e.g., EV adoption rates) that vary widely in the literature. Additionally, the initial process flow diagrams and equipment lists for the recycling cost model are based on the Argonne EverBatt model, which is still under development. However, in combination with a critical review of the literature, economic modeling can yield valuable insights into the role of innovation in the circularity of LIBs and high-technology (“energy relevant”) products in general.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Net Load Redistribution Attacks on Nodal Voltage Magnitude Estimation in AC Distribution Networks

A high penetration level of smart devices and communication networks increases the threat of cyber-attacks in the distribution system. In this paper, we model a hidden, coordinated, net load redistribution attack (NLRA) in an AC distribution system. Based on local information of an attack region, the attacker’s goal is to create violations in nodal voltage magnitude estimation. Acting as a system operator equipped with global AC state estimation and bad data detection, we validate the stealthiness of the hidden NLRA in multiple attack cases. Simulation results on a modified PG&E 69-node distribution system show the validity of the proposed NLRA. The influence of NLRA on the distribution system is assessed and the impact of attack regions, attack timing, and system observability is also revealed.

Zhang, Hang↗

An improved method for quantitatively measuring antifouling coating performance using a mussel single thread tensile adhesion test

Surface biofouling reduces the efficiency and lifespan of equipment across many industries. The development of high-performance antifouling surfaces, such as foul release coatings, benefits from test methods that can quickly identify superior antifouling surfaces in the laboratory during material development. Existing test methods poorly discriminate between different foul release coatings. Here is presented a method to assess the ability of surfaces to resist mussel adhesion using a quantitative, controlled single thread adhesion test (STAT) method, allowing for meaningful comparisons between low adhesion foul release surfaces. This method provides greater accuracy and finer resolution than push-based mussel shear adhesion methods without the difficulties associated with mussel size, thread attachment angle, or harming the mussels. The single thread tensile method is demonstrated on a variety of standard and high-performance coatings, and it is shown that the method detects differentiation between commercial foul release coatings that could not be resolved using other methods.

42 ENGINEERING↗

Scalable and Actionable Performance Measures for Traffic Signal Systems using Probe Vehicle Trajectory Data

Scalable and actionable performance measures for traffic signal systems provide opportunities for practitioners to measure and improve the transportation network. Historically, traffic signal improvements have relied on scheduled signal retiming based on limited data collection, or on the public to call and alert engineers of an issue. This inefficient method of improving signal timing led to the creation of automated traffic signal performance measures (ATSPMs). These metrics rely on expensive infrastructure, including detection and communications, which has produced barriers for numerous agencies to fully adopt. Recently, third-party data providers have begun to release vehicle trajectory data, which allows for enhanced signal metrics with no investment in physical equipment. The purpose of this study is to demonstrate the use of these data and summarize the scalability of the created metrics. This work builds on previous efforts to quantify signal performance on nine intersections in Michigan, U.S. Ten signalized corridors in Columbus, Ohio, were chosen to scale a performance assessment using crowdsourced trajectory data. A total of 136 intersections were assessed in 2-h intervals using data from all weekdays in 2017. High-level corridor summary metrics including average percent of vehicles stopping (18%–32%), average delay (9.4–20.5 s), and level of travel time reliability (1.23–2.73) were calculated for each corridor direction. Intersection-level metrics were also introduced, which can be used by practitioners to identify problems, improve signal timings, and prioritize future infrastructure investments.

99 GENERAL AND MISCELLANEOUS↗

Arc Flash Evaluation Poster

Arc flash evaluation is a key aspect of assessing the safety of an electrical system. An arc flash occurs when a short circuit results in large amounts of unexpected current in a conductor leading to a massive release of energy. By conducting an arc flash evaluation engineers are able to design safer systems and determine the level of protective equipment that a worker needs to wear in order to survive an arc flash incident.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technical Specification Surveillance Interval Extension Using Self-Diagnostics

As part of the Light Water Reactor Sustainability program, an ongoing research effort is being conducted on technical specifications surveillance interval extension of digital equipment in nuclear power plants. The research team is led by Idaho National Laboratory and includes Pacific Northwest National Laboratory, Technology Resources, and Oak Ridge National Laboratory. This research focuses on developing methods for applying the U.S. Nuclear Regulatory Commission (NRC)–approved guidance to implement a licensee-controlled, risk-informed surveillance frequency change program in digital instrumentation and control (I&C) systems that include self-diagnostics and online monitoring (OLM) capabilities. Although approved methods exist for extending technical specifications (TS) surveillance test intervals (STIs) for general equipment, including analog I&C equipment, gaps remain in technology and guidance on crediting newer digital equipment’s internal self-diagnostics and OLM characteristics. Previous research described a general methodology for crediting internal self-diagnostics for extending surveillance test intervals. The methodology used self-diagnostics to detect—and credited recovery from—failure. Self-diagnostics were also applied for performance monitoring during the extended surveillance interval. This report discusses the status of recent activities to evaluate the previously developed methodology using a pilot study. Although both a utility partner for a pilot study and a specific digital asset were identified in FY2020, delays in obtaining proprietary information resulted in a limited ability to fully evaluate the methodology, and further interactions were complicated by the COVID pandemic. Therefore, at that time, the use of public-domain information—along with current processes for surveillance interval extension through a surveillance frequency control program—identified the need to fully assess diagnostic coverage as part of the pilot study. Furthermore, self-diagnostics were also identified as a potential option to replace the drift analyses conducted as part of current STI extension procedures. In FY2022, the project was reconstituted with the industry partner, and information and data were made available by the industry partner to the research team for review. The shared information included failure event descriptions and data for a digital I&C system since its implementation, as well as recent STI extension interval reports developed by the utility partner on that digital I&C system. This report presents an evaluation of this information and data and describes an application of the proposed methodology cited above. The methodology seeks to take advantage of the self-diagnostics and OLM capabilities to reduce risk or reduce the level of qualitative monitoring assessment needed to perform a risk-informed STI extension using existing NRC approved guidance or both. Addressing these issues of STI extension by crediting self-diagnostics is likely to result in benefits for current and future nuclear power plant (NPP) operations, including lowering the barriers to adoption of digital I&C systems and increasing cost savings by deferring or eliminating unneeded preventive maintenance (tasks or checks or activities). Specifically, self-diagnostic and OLM capabilities of newer digital equipment being installed in non-safety and safety applications are designed to detect failures, provide early warning of potential failures, and notify plant operators to take appropriate action to reduce out of service (OOS) time thus protecting safety margins. Moreover, the equipment is expected to provide information that time-related operational degradation is identified early to ensure timely and planned corrective actions instead of a reactive and unplanned approach ahead of an extended-surveillance interval.

42 ENGINEERING↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

Hydrogen technology for maritime applications: A review of challenges, opportunities, and lessons from the port authority of New York and New Jersey

The maritime industry faces increasing demand for energy security, operational efficiency, and environmental performance improvements. Hydrogen technology, considered a potential energy carrier, is being explored for port operations, including cargo-handling equipment, heavy-duty vehicles, and stationary power systems. This review evaluates the feasibility, challenges, and potential benefits of hydrogen integration within port infrastructure, using the Port Authority of New York and New Jersey as a representative case study. Drawing on case studies, technical reports, and policy analyses, this study examines the infrastructural, regulatory, and operational factors influencing large-scale deployment, emphasizing supply chain development, storage requirements, and refueling infrastructure. By situating hydrogen within broader maritime energy transition efforts, this review provides an evidence-based assessment of its role in port operations and energy diversification strategies. In conclusion, the findings outline key barriers to adoption and emphasize the need for coordinated efforts among stakeholders to determine hydrogen's role alongside other emerging energy technologies.

08 HYDROGEN↗