Search NASA⌕ Search

SEARCH · Search NASA

Results for “Examination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Summary of Forensic Examinations in Support of Breach Sealed Source Event at Harborview Medical Facility on 2 May 2019

On May 2, 2019, International Isotopes, Inc. (INIS), a subcontractor to Triad National Security, LLC (contractor for Los Alamos National Laboratory) breached a sealed radioactive source containing ~2800 Ci of the radioactive isotope cesium-137 ( 137 Cs) at the University of Washington Harborview Research and Training (HRT) Building in downtown Seattle while attempting to recover the source for the National Nuclear Security Administration’s (NNSA’s) Off-site Source Recovery Program (OSRP). The breach of the source resulted in the contamination of 13 personnel, all 7 floors of the building, and a release of material to the environment. A summary of root and contributing causes of the event was investigated and published by a joint investigation team (JIT) co-led by NNSA and Triad National Security, LLC. That investigation was supported by forensics examinations provided by Pacific Northwest National Laboratory. This report summarizes the results of those forensic examinations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sister Rod Destructive Examinations (FY23) Appendix C: Rod Internal Pressure, Void Volume, and Gas Transmission Tests

As a part of the DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWD/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called the sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin (LT) Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rod’s condition before dry storage and are focused on understanding overall SNF rod strength and durability. Both fuel rods and empty cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the postirradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and consolidation activities. This appendix documents the status of the ORNL Phase 1 DE activities related to rod internal pressure and void volume measurement techniques, fission gas stack flow measurements applied to selected sister rods, and fission gas release calculations in Phase 1 of the sister rod test program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sister Rod Destructive Examinations (FY23) Appendix A: Full-Length Rod Heat Treatments

As a part of DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWd/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rod’s condition before dry storage and are focused on understanding overall SNF rod strength and durability. Composite fuel and defueled cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the post-irradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and subsequent disposition. This report documents the status of the ORNL Phase 1 DE activities related to full-length rod heat treatments (FHT) applied to selected sister rods in Phase 1 of the sister rod test program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Post-Irradiation Examination to Quantify Irradiation-Induced Bowing of SiGA® Silicon Carbide Composite Structures (Final CRADA Report – NFE-23-09937)

As part of the SiC-based material development at General Atomics Electromagnetic Systems (GA-EMS), this project involved the first-of-a-kind experimental post-irradiation examination of the irradiation-induced bowing response in SiC composite structures under a neutron flux gradient. The SiC composite miniature channel specimen was provided by GA-EMS for the irradiation experiment. To quantify the irradiation-induced bowing of the channel specimen, a series of visual and dimensional inspections were conducted using the unique capabilities at Oak Ridge National Laboratory (ORNL), including a custom profilometry rig. The post-irradiation examination results of this project will assist GA-EMS in validating their fuel performance model for SiC-based core structures in neutron irradiation environments.

36 MATERIALS SCIENCE↗

Enabling Digital Image Correlation for Deployment in the Hot Fuels Examination Facility

Digital image correlation (DIC) is a non-contact image-based technique for displacement and strain measurement. It is also a full-field method that can provide excellent spatial resolution. DIC has been widely used for measurements in many styles of mechanical tests and is desirable in part because of this flexibility to measure nearly any material across a range of time and length scales. Its ability to measure localized strain for tests and in environments not accessible to other strain measurement techniques makes it an ideal option for several mechanical test cases that exist in hot cell facilities such as the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). However, DIC has not been demonstrated at HFEF, and several barriers to implementation in the hot cell environment exist. This report outlines the possible paths for deploying DIC at HFEF, weighing the technical advantages and risks with each path. It also discusses the steps which must be taken to add this capability to the suite of post-irradiation examination (PIE) techniques available at HFEF. Finally, it concludes with recommendations for the best method to perform DIC at the facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sister Rod Destructive Examinations (FY23) Appendix B: Segmentation, Defueling, Metallographic Data and Total Cladding Hydrogen

As a part of the DOE-NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWd/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called sister rods or sibling rods are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin (LT) Zirc-4, ZIRLO ® , and M5 ® . The DEs are being conducted to obtain a baseline of the HBU rod’s condition before dry storage and are focused on understanding overall SNF rod strength and durability. Both composite fuel and defueled cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the post-irradiation examination data and associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and subsequent disposition of the SNF. This report documents the status of the ORNL Phase 1 DE activities related to: Rough segmentation (RS), Defueling (DEF), DE.02 optical microscopy (MET), and DE.03, cladding total hydrogen measurements. It is a cumulative update to the FY22 status report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sister Rod Destructive Examinations (FY22) Appendix E: Mechanical Testing

As a part of the DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWd/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rod’s condition before dry storage and are focused on understanding overall SNF rod strength and durability. Composite fuel and defueled cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the post-irradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and subsequent disposition.This appendix documents the status of the ORNL Phase 1 DE activities related to the mechanical testing of selected sister rods in Phase 1 of the sister rod test program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sister Rod Destructive Examinations (FY23) Appendix D: Fission Gas, Fuel Burnup, and Fuel Isotopic Measurements

As a part of DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWd/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin (LT) Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rod’s condition before dry storage and are focused on understanding overall SNF rod strength and durability. Composite fuel and defueled cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the post-irradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and subsequent disposition. This appendix documents the status of the ORNL Phase 1 DE activities related to fission gas sample analysis, fuel burnup analysis, and fuel isotopic analysis of selected sister specimens in Phase 1 of the sister rod test program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sister Rod Destructive Examinations (FY23) Appendix E2: Four-Point Bend Fractured Specimen Images

This report documents work performed under the Spent Fuel and Waste Disposition’s Spent Fuel and Waste Science and Technology program for the US Department of Energy (DOE) Office of Nuclear Energy (NE). This work was performed to fulfill Level 2 Milestone M2SF-24OR010201024, “FY23 ORNL Testing on Sibling Pins,” within work package SF-24OR01020102 and is an update to the work reported in M2SF-23OR010201024, M2SF-22OR010201047, M2SF-21OR010201032, M2SF-19ORO010201026, and M2SF-19OR010201028. As a part of the DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWd/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rods’ condition before they are sent to dry storage and are focused on gaining an understanding of overall SNF rod strength and durability. Composite fuel and defueled cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the post-irradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and subsequent disposition. This report documents the status of the ORNL Phase 1 DE activities related to the mechanical testing of selected sister rods in Phase 1 of the sister rod test program. This appendix provides images of the segments broken in four-point bending (4PB).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sister Rod Destructive Examinations (FY23)

As a part of DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWd/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin (LT) Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rod’s condition before dry storage and are focused on understanding overall SNF rod strength and durability. Composite fuel and defueled cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the post-irradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and subsequent disposition. This report provides a cumulative status report of the testing progress, data accumulated, and conclusions reached as a part of the program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sister Rod Destructive Examinations (FY23) Appendix I: SNF Aerosols Released During Rod Fracture

This report documents work performed under the Spent Fuel and Waste Disposition’s Spent Fuel and Waste Science and Technology program for the US Department of Energy (DOE) Office of Nuclear Energy (NE). This work was performed to fulfill Level 3 Milestone M3SF-23OR010201026, “FY23 M3 draft report on results from testing in FY23,” within work package SF-23OR01020102 and is an updated to the work reported in M2SF-23OR010201024, M2SF-22OR010201047, M2SF-21OR010201032, M2SF-19ORO010201026, and M2SF-19OR010201028. As a part of the DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWd/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rods’ condition before dry storage and are focused on understanding overall SNF rod strength and durability. Fuel rods and defueled cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the post-irradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and subsequent disposition.This report documents the status of the ORNL Phase 1 DE activities related to the collection of SNF aerosol particles released during fuel rod fracture in 4-point bending in Phase 1 of the sister rod test program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

U.S. Efforts in Support of Examinations at Fukushima Daiichi - September 2024 Meeting Notes

Information obtained from Fukushima Daiichi Nuclear Power Station (Daiichi) is required to inform future Decontamination and Decommissioning (D&D) activities, improving the ability of the Tokyo Electric Power Company Holdings, Incorporated (TEPCO Holdings) to characterize potential hazards and to ensure the safety of workers involved with cleanup activities. This information also has important implications for the safety and operation of U.S. Commercial nuclear power plants. A collaborative U.S. and Japanese effort was initiated in 2014 by the Department of Energy Office of Nuclear Energy to identify Daiichi examination needs and evaluate recent Daiichi examination data to address these needs. This document summarizes information presented at and findings, action items, and recommendations by U.S. and Japanese experts in reactor safety and plant operations during the September 2024 Forensics Effort meeting. Significant safety insights were obtained in several areas: system and component performance, radionuclide surveys and sampling, debris end-state location, combustible gas effects, and plant operations and maintenance. In addition to reducing uncertainties and knowledge gaps in severe accident modeling progression, these insights continue to be used to assess whether additional updates are needed in guidance for severe accident prevention, mitigation, and emergency planning. Furthermore, Daiichi-related activities, such as code modeling improvements and analysis, testing, and new technology deployment efforts, have the potential to offer additional safety and economic benefits to the operating fleet and new light water reactor (LWR) and non-LWR designs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Examining the Ice-Nucleating Particles from the North Slope of Alaska (ExINP-NSA) (Final Campaign Report)

The Examining the Ice-Nucleating Particles from the North Slope of Alaska (ExINP-NSA) campaign was conducted at the National Oceanic and Atmospheric Administration’s (NOAA) Barrow Atmospheric Baseline Observatory (71.3230° N, 156.6114° W, “BRW” hereafter), next to the Atmospheric Radiation Measurement (ARM) user facility NSA site and ~ 6 km northeast of the town of Utqiaġvik. The location of the NSA site is shown in Figure 1. Our observing period began in October 2021 and continued until May 2024. This campaign was funded by the U.S. Department of Energy (DOE) Office of Science Early Career Research Program through grant number DE-SC001879. This grant contains funding for three ARM field campaigns. The previous field campaigns were performed at ARM’s Southern Great Plains atmospheric observatory in Oklahoma (SGP; 36.6073° N, 97.4876° W) and the ARM’s Eastern North Atlantic atmospheric observatory on Graciosa Island, Azores (ENA; 39.0916° N, 28.0257° W). The ExINP-NSA campaign aims included: • Determining the number concentration of ice-nucleating particles (n INPs ) active at temperatures spanning the range of heterogeneous freezing processes (from ≈−30 °C to 0 °C) using a combination of online and offline measurements, • Determining whether local meteorological conditions and/or synoptic scale air mass transport impact INP abundance and/or ice nucleation efficiency, • Examining if the physicochemical properties of INPs relate to aerosol chemistry, and • Assessing if there is a similarity in INP properties across three ARM sites Multi-seasonal datasets of INP abundance in the NSA region were delivered from this campaign. This campaign also allowed researchers to perform a comprehensive analysis of atmospheric INPs based on long- term ground-based measurements in the Alaskan Arctic. Our data and results from the ExINP-NSA campaign will help refine current earth system models. One of the stated goals of ARM is to advance aerosol-cloud ice interaction, which will be a direct result of this campaign. Current earth system models poorly represent INPs, and the 15-minute time resolution data over several seasons generated during this campaign will provide an invaluable resource, especially combined with the datasets generated during two previous ARM ExINP campaigns. These datasets will allow for a greater understanding of ice nucleation processes as they may (or may not) relate to local meteorological processes and aerosol chemistry and will eventually help further the understanding of the Earth’s atmospheric processes and energy balance.

54 ENVIRONMENTAL SCIENCES↗

REPORT OF THE WORKSHOP ON NUCLEAR FACILITY DESIGN INFORMATION EXAMINATION AND VERIFICATION FOR SAFEGUARDS

Executive Summary The International Atomic Energy Agency (IAEA) implements nuclear safeguards and verifies countries are compliant with their international nuclear safeguards agreements. One of the key provisions in the safeguards agreement is the requirement that the country provide nuclear facility design and operating information to the IAEA relevant to safeguarding the facility, and at a very early stage. , This provides the opportunity for the IAEA to verify the safeguards-relevant features of the facility and to periodically ensure that those features have not changed. The national authorities (State System of Accounting for and Control of Nuclear Material - SSAC) provide the design information for all facilities within a country to the IAEA. The design information is conveyed using the IAEA’s Design Information Questionnaire (DIQ) and specifies: (1) Identification of the facility’s general character, purpose, capacity, and location; (2) Description of the facility’s layout and nuclear material form, location, and flow; (3) Description of the features relating to nuclear material accounting, containment, and surveillance; and (4) Description of existing and proposed procedures for nuclear material accounting and control, with identification of nuclear material balance areas. The DIQ is updated as required by written addendum. IAEA safeguards inspectors examine and verify this information in design information examination (DIE) and design information verification (DIV) activities to confirm that the facility has been constructed or is being operated as declared by the facility operator and national authorities, and to develop a suitable safeguards approach. Under the Next Generation Safeguards Initiative (NGSI), the National Nuclear Security Administrations (NNSA) Office of Non-Proliferation and International Security identified the need for more effective and efficient verification of design information by the IAEA for improving international safeguards in the future. Consequently, the NNSA Office of International Regimes and Agreements (NA-243) sponsored a team of U.S. Department of Energy National Laboratory nuclear safeguards experts and technologists to conduct a workshop on methods and technologies for improving this activity, under the ASA-100 Advanced Safeguards Approaches Project. The workshop focused on reviewing and discussing the fundamental safeguards needs, and presented technology and/or methods that could potentially address those needs more effectively and efficiently. Conclusions and Recommendations for technology to enhance the performance of DIV inspections are presented by the workshop team.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

EXAMINATION OF SHIPPING PACKAGES 9975-01818, 9975-01903 AND 9975-02287

Three 9975 shipping packages were examined to investigate the non-conforming condition of an axial air gap greater than 1 inch. This condition typically indicates the presence of excess moisture in the fiberboard overpack, and may be accompanied by degradation in the fiberboard properties. The package with the largest axial air gap (9975-01818, with an air gap of 1.437 inches) was found to contain significant excess moisture, and the lower fiberboard assembly was covered with mold and was significantly degraded in strength. This condition is very similar to that observed previously in package 9975-01819. Both packages (-1818 and -1819) appear to contain a similar amount of excess moisture, which was previously estimated for 9975-01819 as {approx}2.5 liters. The condition of 9975-01818 was also evidenced by several rust spots along the bottom chime of the drum, although no significant rust was noted on the closure bolts. Packages 9975-01903 and 9975-02287 were also examined. The axial air gap in these two packages was less than in 9975-01818, but still exceeded 1 inch. These two packages contained elevated moisture levels, although not significantly higher than seen in other 'typical' packages. The fiberboard in these two packages was of sound integrity, and appeared generally consistent with undegraded material. A few small patches of mold on and near the bottom of the fiberboard in 9975-01903 appeared dormant. No mold was observed on package 9975-02287. The SPA will provide recommendations on possible follow-up activities with these three packages. This might include a demonstration in SRNL of whether removal of the caplugs from similar packages would facilitate removal of excess moisture. Future efforts should also include an assessment of using the 1 inch axial gap criterion as a valid indicator of fiberboard degradation.

42 ENGINEERING↗

IV Administered Gadodiamide Enters the Lumen of the Prostatic Glands: X-Ray Fluorescence Microscopy Examination of a Mouse Model

In our objective, we descibe how dynamic contrast-enhanced MRI (DCE-MRI) has become a standard component of multiparametric protocols for MRI examination of the prostate, and its use is incorporated into current guidelines for prostate MRI examination. Analysis of DCE-MRI data for the prostate is usually based on the distribution of gadolinium-based agents, such as gadodiamide, into two well-mixed compartments, and it assumes that gadodiamide does not enter into the glandular lumen. However, this assumption has not been directly tested. The purpose of this study was to use x-ray fluorescence microscopy (XFM) imaging in situ to measure the concentration of gadodiamide in the epithelia and lumens of the prostate of healthy mice after IV injection of the contrast agent. For our materials and methods, six C57Bl6 male mice (age, 28 weeks) were sacrificed 10 minutes after IV injection of gadodiamide (0.13 mmol/kg), and three mice were sacrificed after saline injection. Prostate tissue samples obtained from each mouse were harvested and frozen; 7-μm-thick slices were sectioned for XFM imaging, and adjacent 5-μm-thick slices were sectioned for H and E staining. Elemental concentrations were determined from XFM images. Our results show mean (± SD) baseline concentration of gadolinium of 0.01 ± 0.01 mM was determined from XFM measurements of prostatic tissue samples when no gadodiamide was administered, and it was used to determine the measurement error. When gadodiamide was added, the mean concentrations of gadolinium in the epithelia and lumens in 32 prostatic glands from six mice were 1.00 ± 0.13 and 0.36 ± 0.09 mM, respectively. In conclusion, our data suggest that IV administration of gadodiamide results in uptake of contrast agent by the glandular lumens of the mouse prostate. We were able to quantitatively determine gadodiamide distributions in mouse prostatic epithelia and lumens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guiding Principles for Geochemical/Thermodynamic Model Development and Validation in Nuclear Waste Disposal: A Close Examination of Recent Thermodynamic Models for H + —Nd 3+ —NO 3 - (—Oxalate) Systems

Development of a defensible source-term model (STM), usually a thermodynamical model for radionuclide solubility calculations, is critical to a performance assessment (PA) of a geologic repository for nuclear waste disposal. Such a model is generally subjected to rigorous regulatory scrutiny. In this article, we highlight key guiding principles for STM model development and validation in nuclear waste management. We illustrate these principles by closely examining three recently developed thermodynamic models with the Pitzer formulism for aqueous H + —Nd 3+ —NO 3 - (—oxalate) systems in a reverse alphabetical order of the authors: the XW model developed by Xiong and Wang, the OWC model developed by Oakes et al., and the GLC model developed by Guignot et al., among which the XW model deals with trace activity coefficients for Nd(III), while the OWC and GLC models are for concentrated Nd(NO 3 ) 3 electrolyte solutions. The principles highlighted include the following: (1) Principle 1. Validation against independent experimental data: A model should be validated against experimental data or field observations that have not been used in the original model parameterization. We tested the XW model against multiple independent experimental data sets including electromotive force (EMF), solubility, water vapor, and water activity measurements. The results show that the XW model is accurate and valid for its intended use for predicting trace activity coefficients and therefore Nd solubility in repository environments. (2) Principle 2. Testing for relevant and sensitive variables: Solution pH is such a variable for an STM and easily acquirable. All three models are checked for their ability to predict pH conditions in Nd(NO 3 ) 3 electrolyte solutions. The OWC model fails to provide a reasonable estimate for solution pH conditions, thus casting serious doubt on its validity for a source-term calculation. In contrast, both the XW and GLC models predict close-to-neutral pH values, in agreement with experimental measurements. (3) Principle 3. Honoring physical constraints: Upon close examination, it is found that the Nd(III)-NO 3 association schema in the OWC model suffers from two shortcomings. Firstly, its second stepwise stability constant for Nd(NO 3 ) 2+ (log K 2 ) is much higher than the first stepwise stability constant for NdNO 3 2+ (log K 1 ), thus violating the general rule of (log K 2 –log K 1 ) < 0, or $\frac{K1}{K2}$>1. Secondly, the OWC model predicts abnormally high activity coefficients for Nd(NO 3 ) 2 + (up to ~900) as the concentration increases. (4) Principle 4. Minimizing degrees of freedom for model fitting: The OWC model with nine fitted parameters is compared with the GLC model with five fitted parameters, as both models apply to the concentrated region for Nd(NO 3 ) 3 electrolyte solutions. The latter appears superior to the former because the latter can fit osmotic coefficient data equally well with fewer model parameters. The work presented here thus illustrates the salient points of geochemical model development, selection, and validation in nuclear waste management.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Examining the Characteristics of the Cropland Data Layer in the Context of Estimating Land Cover Change

The United States Department of Agriculture (USDA) Cropland Data Layer (CDL) provides spatially explicit information about crop production area and has served as a prevalent data source for characterizing cropland change in the U.S. in the last decade. Understanding the accuracy of the CDL is paramount because of the reliance on it for management and policy making. This study examined the characteristics of the CDL from 2007 to 2017 using comparisons to other USDA datasets. The results showed when examining the cropland area for the same year, the CDL produced comparable trends with other datasets (R 2 > 0.95), but absolute area differed. The estimated area of cropland changes from 2007 to 2012, 2008 to 2012 and 2012 to 2017 varied from weak to moderate correlation between the CDL and the tabular data (R 2 = 0.005~0.63). Differences in area of cropland change varied widely between data sources with the CDL estimating much larger change area. A series of image processing techniques designed to improve the confidence in cropland change estimated using the CDL reduced the area of estimated cropland change. The techniques also, unexpectedly, lowered the correlation in change estimated between the CDL and the tabular datasets. Estimated land cover change area varied widely based on analyses applied and could reverse from increasing to declining area in cropland. Further analyses showed unlikely change scenarios when comparing different year combinations. The authors recommend the CDL only be used for land cover change analysis if the error can be estimated and is within change estimates.

58 GEOSCIENCES↗