At least 307 records · Page 17

Characterization of impurity confinement on Alcator C-Mod using a multi-pulse laser blow-off system

A new laser blow-off system for use in impurity transport studies on Alcator C-Mod was developed and installed for the 2009 run campaign. Its design included capabilities for multiple impurity injections during a single plasma pulse and remote manipulation of the ablated spot size. The system uses a 0.68 J, Nd:YAG laser operating at up to 10 Hz coupled with the fast beam steering via a 2D piezoelectric mirror mount able to move spot locations in the 100 ms between laser pulses and a remote controllable optical train that allow ablated spot sizes to vary from {approx}0.5 to 7 mm. The ability to ablate a wide range in target Z along with Alcator C-Mod's extensive diagnostic capabilities (soft x-ray, vacuum ultraviolet (VUV), charge exchange spectroscopy, etc.) allows for detailed studies of the impurity transport dependencies and mechanisms. This system has demonstrated the achievement of all its design goals including the ability for non-perturbative operation allowing for insight into underlying impurity transport processes. A detailed overview of the laser blow-off system and initial results of operation are presented. This includes an investigation into the characterization of impurity confinement in the I-mode confinement regime recently investigated on C-Mod.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Xenon excimer emission from multicapillary discharges in direct current mode

Microdischarges in xenon have been generated in a pressure range of 400-1013 mbar with a fixed flow rate of 100 sccm. These microdischarges are obtained from three metallic capillary tubes in series for excimer emission. Total discharge voltage is thrice as large as that of a single capillary discharge tube at current levels of up to 12 mA. Total spectral irradiance of vacuum ultraviolet (VUV) emission also increases significantly compared to that of the single capillary discharge. Further, the irradiance of the VUV emission is strongly dependent on pressure as well as the discharge current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanism of high luminous efficacy in plasma display panel with high secondary electron emission coefficient cathode material analyzed through three-dimensional fluid model simulation

The mechanism to realize high luminous efficacy in a plasma display panel fabricated with a cathode material possessing a high secondary electron emission coefficient ({gamma}) for Ne and Xe ions was studied via three-dimensional numerical simulation. When a high {gamma} cathode material is used, the increased electron heating efficacy is responsible for increasing vacuum ultraviolet (VUV) efficacy with 10% Xe content gas. However, the continued availability of sufficient secondary electrons during the dynamic moving phase of the cathode sheath in which the electric field remains weakened causes increasing VUV efficacy with 30% Xe content gas. It was found that the improvement of the luminous efficacy of the plasma display panel with a high {gamma} cathode material is maximized under the condition of high Xe content gas because of the simultaneous increase of the electron heating efficacy and Xe excitation efficacy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of pulsed high-density HBr and Cl{sub 2} plasmas: Impact of the pulsing parameters on the radical densities

The dynamic of charged particles in pulsed plasma is relatively well known since the 1990s. In contrast, works reporting on the impact of the plasma modulation frequency and duty cycle on the radicals' densities are scarce. In this work, we analyze the impact of these modulation parameters on the radicals' composition in Cl{sub 2} and HBr plasmas. The radicals' densities are measured by broad-band UV and vacuum-ultraviolet (VUV) absorption spectroscopy and modulated-beam mass spectrometry. We show that pulsing the rf power allows controlling the plasma chemistry and gives access to the plasma conditions that cannot be reached in continuous wave plasmas. In particular, we show that above 500 Hz, the pulsing frequency has no influence on the plasma chemistry, whereas in contrast the duty cycle is an excellent knob to control the fragmentation of the parent gas, thus the chemical reactivity of the discharge. At low duty cycle, a reduced gas fragmentation combined with a large ion flux leads to new etching conditions, compared to cw plasmas and the expected consequences on pulsed-etching processes are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-dependent dielectric breakdown of plasma-exposed porous organosilicate glass

Time-dependent dielectric breakdown (TDDB) is a major concern for low-k organosilicate dielectrics. To examine the effect of plasma exposure on TDDB degradation, time-to-breakdown measurements were made on porous SiCOH before and after exposure to plasma. A capillary-array window was used to separate charged particle and vacuum ultraviolet (VUV) photon bombardment. Samples exposed to VUV photons, and a combination of VUV photons and ion bombardment exhibited significant degradation in breakdown time. The samples exposed to VUV photons and ion bombardment showed more degradation in breakdown time in comparison to samples exposed to VUV photons alone.

36 MATERIALS SCIENCE↗

Central electron temperature estimations of TJ-II neutral beam injection heated plasmas based on the soft x ray multi-foil technique

The core electron temperature (T{sub e0}) of neutral beam heated plasmas is determined in TJ-II stellarator by using soft x ray detectors with beryllium filters of different thickness, based on the method known as the foil absorption technique. T{sub e0} estimations are done with the impurity code IONEQ, making use of complementary information from the TJ-II soft x ray tomography and the VUV survey diagnostics. When considering the actual electron density and temperature profile shapes, an acceptable agreement is found with Thomson scattering measurements for 8 different magnetic configurations. The impact of the use of both neutral beam injectors on the T{sub e0} measurements is addressed. Also, the behaviour of T{sub e0} during spontaneous profile transitions is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

VUV 157nm laser ablation of spherical particles and modelling of whispering gallery mode optical antenna structures

We report on VUV 157nm F{sub 2} laser irradiation of CR-39 polymer substrates that have been intentionally seeded with spherical glass particles. We discuss the importance of adhesive forces for realizing spherical cavity structures by laser ablation. Strong optical absorption at 157nm in CR-39 enables precise control of pedestal height by controlling the laser fluence and the number of laser pulses. Resonant modes for free-standing spherical cavities have been calculated and we discuss briefly the potential applications for use as optical sources on-board lab-on-chip devices.

36 MATERIALS SCIENCE↗

Rovibrationally selected ion-molecule collision study using the molecular beam vacuum ultraviolet laser pulsed field ionization-photoion method: Charge transfer reaction of N{sub 2}{sup +}(X {sup 2}{Sigma}{sub g}{sup +}; v{sup +}= 0-2; N{sup +}= 0-9) + Ar

We have developed an ion-molecule reaction apparatus for state-selected absolute total cross section measurements by implementing a high-resolution molecular beam vacuum ultraviolet (VUV) laser pulsed field ionization-photoion (PFI-PI) ion source to a double-quadrupole double-octopole ion-guide mass spectrometer. Using the total cross section measurement of the state-selected N{sub 2}{sup +}(v{sup +}, N{sup +}) + Ar charge transfer (CT) reaction as an example, we describe in detail the design of the VUV laser PFI-PI ion source used, which has made possible the preparation of reactant N{sub 2}{sup +}(X {sup 2}{Sigma}{sub g}{sup +}, v{sup +}= 0-2, N{sup +}= 0-9) PFI-PIs with high quantum state purity, high intensity, and high kinetic energy resolution. The PFI-PIs and prompt ions produced in the ion source are shown to have different kinetic energies, allowing the clean rejection of prompt ions from the PFI-PI beam by applying a retarding potential barrier upstream of the PFI-PI source. By optimizing the width and amplitude of the pulsed electric fields employed to the VUV-PFI-PI source, we show that the reactant N{sub 2}{sup +} PFI-PI beam can be formed with a laboratory kinetic energy resolution of {Delta}E{sub lab}={+-} 50 meV. As a result, the total cross section measurement can be conducted at center-of-mass kinetic energies (E{sub cm}'s) down to thermal energies. Absolute total rovibrationally selected cross sections {sigma}(v{sup +}= 0-2, N{sup +}= 0-9) for the N{sub 2}{sup +}(X {sup 2}{Sigma}{sub g}{sup +}; v{sup +}= 0-2, N{sup +}= 0-9) + Ar CT reaction have been measured in the E{sub cm} range of 0.04-10.0 eV, revealing strong vibrational enhancements and E{sub cm}-dependencies of {sigma}(v{sup +}= 0-2, N{sup +}= 0-9). The thermochemical threshold at E{sub cm}= 0.179 eV for the formation of Ar{sup +} from N{sub 2}{sup +}(X; v{sup +}= 0, N{sup +}) + Ar was observed by the measured {sigma}(v{sup +}= 0), confirming the narrow {Delta}E{sub cm} spread achieved in the present study. The {sigma}(v{sup +}= 0-2; N{sup +}) values obtained here are compared with previous experimental and theoretical results. The theoretical predictions calculated based on the Landau-Zener-Stueckelberg formulism are found to be in fair agreement with the present measured {sigma}(v{sup +}= 1 or 2; N{sup +}). Taking into account of the experimental uncertainties, the measured {sigma}(v{sup +}= 1 or 2, N{sup +}) for N{sup +}= 0-9 at E{sub cm}= 0.04-10.0 eV are found to be independent of N{sup +}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Competitive fragmentation pathways of acetic acid dimer explored by synchrotron VUV photoionization mass spectrometry and electronic structure calculations

In present study, photoionization and dissociation of acetic acid dimers have been studied with the synchrotron vacuum ultraviolet photoionization mass spectrometry and theoretical calculations. Besides the intense signal corresponding to protonated cluster ions (CH{sub 3}COOH){sub n}{center_dot}H{sup +}, the feature related to the fragment ions (CH{sub 3}COOH)H{sup +}{center_dot}COO (105 amu) via {beta}-carbon-carbon bond cleavage is observed. By scanning photoionization efficiency spectra, appearance energies of the fragments (CH{sub 3}COOH){center_dot}H{sup +} and (CH{sub 3}COOH)H{sup +}{center_dot}COO are obtained. With the aid of theoretical calculations, seven fragmentation channels of acetic acid dimer cations were discussed, where five cation isomers of acetic acid dimer are involved. While four of them are found to generate the protonated species, only one of them can dissociate into a C-C bond cleavage product (CH{sub 3}COOH)H{sup +}{center_dot}COO. After surmounting the methyl hydrogen-transfer barrier 10.84 {+-} 0.05 eV, the opening of dissociative channel to produce ions (CH{sub 3}COOH){sup +} becomes the most competitive path. When photon energy increases to 12.4 eV, we also found dimer cations can be fragmented and generate new cations (CH{sub 3}COOH){center_dot}CH{sub 3}CO{sup +}. Kinetics, thermodynamics, and entropy factors for these competitive dissociation pathways are discussed. The present report provides a clear picture of the photoionization and dissociation processes of the acetic acid dimer in the range of the photon energy 9-15 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Communication: A vibrational study of propargyl cation using the vacuum ultraviolet laser velocity-map imaging photoelectron method

By employing the vacuum ultraviolet (VUV) laser velocity-map imaging photoelectron (VUV-VMI-PE) method, we have obtained a vibrationally resolved photoelectron spectrum of gaseous propargyl radical [C{sub 3}H{sub 3}(X{sup 2}B{sub 1})] in the energy range of 0-4600 cm{sup -1} above its ionization energy. The cold C{sub 3}H{sub 3} radicals were produced from a supersonically cooled radical beam source based on 193 nm ArF photodissociation of C{sub 3}H{sub 3}Cl. The VUV-VMI-PE spectrum of C{sub 3}H{sub 3} thus obtained reveals a Franck-Condon factor (FCF) pattern with a highly dominant origin band along with weak vibrational progressions associated with excitations of the C-C {nu}{sub 5}{sup +}(a{sub 1}) and C{identical_to}C {nu}{sub 3}{sup +}(a{sub 1}) symmetric stretching modes and the CCH {nu}{sub 7}{sup +}(b{sub 1}) out-of-plane bending mode of C{sub 3}H{sub 3}{sup +}(X{sup 1}A{sub 1}). The {nu}{sub 5}{sup +}(a{sub 1}) vibrational frequency of 1120 cm{sup -1} determined in the present study is lower than the value deduced from the recent Ar-tagged infrared photodissociation study by 102 cm{sup -1}, confirming the highly accurate vibrational frequency predictions obtained by the most recent state-of-the-art ab initio quantum calculations. The observation of the FCF disallowed {nu}{sub 7}{sup +}(b{sub 1}) mode is indicative of vibronic interactions. The discrepancy observed between the FCF pattern determined in the present study and that predicted by a recent high-level quantum theoretical investigation can be taken as evidence that the potential energy surfaces used in the latter theoretical study are in need of improvement in order to provide a reliable FCF prediction for the C{sub 3}H{sub 3}/C{sub 3}H{sub 3}{sup +} photoionization system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revisiting the mechanisms involved in Line Width Roughness smoothing of 193 nm photoresist patterns during HBr plasma treatment

HBr plasma treatments are widely used in nanoscale lithographic technologies to increase the plasma etch resistance of 193 nm photoresist masks as well as to decrease their Line Width Roughness (LWR). VUV irradiation of the photoresist is known to play a major role in this process by inducing polymer chains rearrangement and finally LWR reduction. However, in the plasma environment (i.e., with radical and ion bombardment), the interaction layer formed at the resist surface perturbs this mechanism and a lower LWR reduction is achieved compared to VUV only treatment. So far the nature of the interaction layer, its formation mechanism and its relation with the resist pattern LWR were all unclear. In this paper, we show that a graphite-like layer is formed on the resist patterns by the redeposition of carbon-based species originating from the plasma dissociation of outgassed photo-etched resist moieties. We show that the presence of this layer inhibits the LWR minimization and causes an increase in the LWR when it becomes thick enough (i.e., a few nanometers). We present evidences that the difference in the mechanical properties of the graphite-like top layer which coats the resist patterns and the bulk of the resist patterns is correlated to the LWR after plasma treatment. We can conclude that the optimization of an HBr cure process relies on the minimization of the carbon redeposition while keeping a significant VUV light flux and we show that this can be achieved by using pulsed plasma processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photo-induced electron detachment of protein polyanions in the VUV range

Biomolecular polyanions mainly relax by electron emission after UV excitation. Here, we study photodetachment of protein polyanions in the 6-16 eV VUV range by coupling a linear quadrupole ion trap with a synchrotron beamline. Gas-phase VUV action spectra of electrospray-produced multiply deprotonated insulin (5.6 kDa) and myoglobin (16.7 kDa) proteins are reported, which significantly increases the amount of data available on the optical response of proteins in the VUV. The influence of the protein charge and oxidation state upon the electron detachment efficiency is discussed. For small protein such as insulin, it appears that higher charge states produce higher detachment yields. Investigations on oxidized species show that the nature of the groups bearing the negative charges has an influence on the yields. For larger proteins, comparison of two forms of myoglobin clearly indicate that the three-dimensional structure does not impact much on the shape and the magnitude of the photodetachment spectra, in spite of a slight shift for the first electronic excited states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of soft x-ray/VUV transmission characteristics of Si and Al filters

Ultrathin filters of Al (1500A) and Si (1200A) should exhibit more than 65% transmission above their Labsorption edges in the soft x-ray/vacuum ultra violet region(Si L-edge: 124 A and Al L-edge: 170 A). However, the measured transmission characteristics of these filters showed {approx}40% transmission. The transmission measurements of these filters were carried at the reflectivity beamline of Indus-1 synchrotron source out over a large wavelength range of 120-360A. In order to understand the measured transmission performance a detailed model fitting is performed using the Paratt formalism. It is found that the oxidation of the surface region of the filters is responsible for the reduced transmission performance. Effects of higher harmonics of the toroidal grating monochromator are also considered in the data analysis.

36 MATERIALS SCIENCE↗

Vacuum ultraviolet emission from microwave Ar-H{sub 2} plasmas

Vacuum ultraviolet emission from Ar-H{sub 2} wave driven microwave (2.45 GHz) plasmas operating at low pressures (0.1-1 mbar) has been investigated. The emitted spectra show the presence of the Ar resonance lines at 104.8 and 106.7 nm and of the Lyman-{alpha},{beta} atomic lines at 121.6 nm and 102.6 nm, respectively. The increase of the hydrogen amount in the mixture results in an abrupt increase of the Werner and Lyman molecular bands intensity. The Lyman-{beta} intensity shows little changes in the range of 5%-30% of hydrogen in the mixture while the Lyman-{alpha} intensity tends to decrease as the percentage of hydrogen increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute atomic oxygen and nitrogen densities in radio-frequency driven atmospheric pressure cold plasmas: Synchrotron vacuum ultra-violet high-resolution Fourier-transform absorption measurements

Reactive atomic species play a key role in emerging cold atmospheric pressure plasma applications, in particular, in plasma medicine. Absolute densities of atomic oxygen and atomic nitrogen were measured in a radio-frequency driven non-equilibrium plasma operated at atmospheric pressure using vacuum ultra-violet (VUV) absorption spectroscopy. The experiment was conducted on the DESIRS synchrotron beamline using a unique VUV Fourier-transform spectrometer. Measurements were carried out in plasmas operated in helium with air-like N{sub 2}/O{sub 2} (4:1) admixtures. A maximum in the O-atom concentration of (9.1 {+-} 0.7) Multiplication-Sign 10{sup 20} m{sup -3} was found at admixtures of 0.35 vol. %, while the N-atom concentration exhibits a maximum of (5.7 {+-} 0.4) Multiplication-Sign 10{sup 19} m{sup -3} at 0.1 vol. %.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of electron energy distribution functions on plasma generated vacuum ultraviolet in a diffusion plasma excited by a microwave surface wave

Plasma generated vacuum ultraviolet (VUV) in diffusion plasma excited by a microwave surface wave has been studied by using dielectric-based VUV sensors. Evolution of plasma VUV in the diffusion plasma as a function of the distance from the power coupling surface is investigated. Experimental results have indicated that the energy and spatial distributions of plasma VUV are mainly controlled by the energy distribution functions of the plasma electrons, i.e., electron energy distribution functions (EEDFs). The study implies that by designing EEDF of plasma, one could be able to tailor plasma VUV in different applications such as in dielectric etching or photo resist smoothing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated experimental setup for angle resolved photoemission spectroscopy of transuranic materials

We have developed the Angle Resolved Photoemission Spectroscopy (ARPES) system for transuranic materials. The ARPES transuranic system is an endstation upgrade to the Laser Plasma Light Source (LPLS) at Los Alamos National Laboratory. The LPLS is a tunable light source for photoemission with a photon energy range covering the vacuum ultraviolet (VUV) and soft x-ray regions (27–140 eV). The LPLS was designed and developed for transuranic materials. Transuranic photoemission is currently not permitted at the public synchrotrons worldwide in the VUV energy range due to sample encapsulation requirements. With the addition of the ARPES capability to the LPLS system there is an excellent opportunity to explore new details centered on the electronic structure of actinide and transuranic materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effusive molecular beam-sampled Knudsen flow reactor coupled to vacuum ultraviolet single photon ionization mass spectrometry using an external free radical source

A new apparatus using vacuum ultraviolet single photon ionization mass spectrometry (VUV SPIMS) of an effusive molecular beam emanating from a Knudsen flow reactor is described. It was designed to study free radical-molecule kinetics over a significant temperature range (300–630 K). Its salient features are: (1) external free radical source, (2) counterpropagating molecular beam and diffuse VUV photon beam meeting in a crossed-beam ion source of a quadrupole mass spectrometer with perpendicular ion extraction, (3) analog detection of the photocurrent of the free radical molecular cation, and (4) possibility of detecting both free radicals and closed shell species in the same apparatus and under identical reaction conditions owing to the presence of photoelectrons generated by the photoelectric effect of the used VUV-photons. The measured thermal molecular beam-to-background ratio was 6.35 ± 0.39 for Ar and 10.86 ± 1.59 for i-C{sub 4}H{sub 10} at 300 K, a factor of 2.52 and 1.50 smaller, respectively, than predicted from basic gas-dynamic considerations. Operating parameters as well as the performance of key elements of the instrument are presented and discussed. Coupled to an external free radical source a steady-state specific exit flow of 1.6 × 10{sup 11} and 5.0 × 10{sup 11} molecule s{sup −1} cm{sup −3} of C{sub 2}H{sub 5}{sup •} (ethyl) and t-C{sub 4}H{sub 9}{sup •} (t-butyl) free radicals have been detected using VUV SPIMS at their molecular ion m/z 29 and 57, respectively, at 300 K.