Search NASA⌕ Search

SEARCH · Search NASA

Results for “FATS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

An efficient polyenergetic SART (pSART) reconstruction algorithm for quantitative myocardial CT perfusion

Purpose: In quantitative myocardial CT perfusion imaging, beam hardening effect due to dense bone and high concentration iodinated contrast agent can result in visible artifacts and inaccurate CT numbers. In this paper, an efficient polyenergetic Simultaneous Algebraic Reconstruction Technique (pSART) was presented to eliminate the beam hardening artifacts and to improve the CT quantitative imaging ability. Methods: Our algorithm made threea priori assumptions: (1) the human body is composed of several base materials (e.g., fat, breast, soft tissue, bone, and iodine); (2) images can be coarsely segmented to two types of regions, i.e., nonbone regions and noniodine regions; and (3) each voxel can be decomposed into a mixture of two most suitable base materials according to its attenuation value and its corresponding region type information. Based on the above assumptions, energy-independent accumulated effective lengths of all base materials can be fast computed in the forward ray-tracing process and be used repeatedly to obtain accurate polyenergetic projections, with which a SART-based equation can correctly update each voxel in the backward projecting process to iteratively reconstruct artifact-free images. This approach effectively reduces the influence of polyenergetic x-ray sources and it further enables monoenergetic images to be reconstructed at any arbitrarily preselected target energies. A series of simulation tests were performed on a size-variable cylindrical phantom and a realistic anthropomorphic thorax phantom. In addition, a phantom experiment was also performed on a clinical CT scanner to further quantitatively validate the proposed algorithm. Results: The simulations with the cylindrical phantom and the anthropomorphic thorax phantom showed that the proposed algorithm completely eliminated beam hardening artifacts and enabled quantitative imaging across different materials, phantom sizes, and spectra, as the absolute relative errors were reduced from [−7.5%, 12.1%] for SART to [−0.1%, 0.1%] for pSART. When using low kVp spectra and high reference energies, pSART also showed improved reconstruction efficiency in terms of convergence speed compared to the conventional SART algorithm. The phantom experiment on a clinical CT scanner indicated that the quantitative advantage of pSART is realizable in experimental CT acquisition, as the absolute relative errors across material inserts were less than 0.4%. Conclusions: By incorporatinga priori information (material attenuation coefficients, x-ray source spectrum, and region type information) into the reconstruction process, the proposed pSART algorithm could effectively eliminate beam hardening artifacts, reconstruct the accurate attenuation coefficients for precise quantitative imaging, and accelerate the reconstruction process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed tomography-based texture analysis of bladder cancer: differentiating urothelial carcinoma from micropapillary carcinoma

Purpose: The purpose of the study is to determine the feasibility of using computed tomography-based texture analysis (CTTA) in differentiating between urothelial carcinomas (UC) of the bladder from micropapillary carcinomas (MPC) of the bladder. Methods: Regions of interests (ROIs) of computerized tomography (CT) images of 33 MPCs and 33 UCs were manually segmented and saved. Custom MATLAB code was used to extract voxel information corresponding to the ROI. The segmented tumors were input to a pre-existing radiomics platform with a CTTA panel. A total of 58 texture metrics were extracted using four different texture extraction techniques and statistically analyzed using a Wilcoxon rank-sum test to determine the differences between UCs and MPCs. Results: Of the 58 texture metrics extracted using the gray level co-occurrence matrix (GLCM) and gray level difference matrix (GLDM), 28 texture metrics were statistically significant (p < 0.05) for differences in tumor textures and 27 texture metrics were statistically significant (p < 0.05) for peritumoral fat textures. The remaining nine metrics extracted using histogram and fast Fourier transform analyses did not show significant differences between the textures of the tumors and their peritumoral fat. Conclusions: CTTA shows that MPC have a more heterogeneous texture compared to UC. As visual discrimination of MPC from UC from clinical CT scans are difficult, results from this study suggest that tumor heterogeneity extracted using GLCM and GLDM may be a good imaging aid in segregating MPC from UC. This tool can aid clinicians in further sub-classifying bladder cancers on routine imaging, a process which has potential to alter treatment and patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of the anatomical site on telomere length and pref-1 gene expression in bovine adipose tissues

Adipose tissue growth is associated with preadipocyte proliferation and differentiation. Telomere length is a biological marker for cell proliferation. Preadipocyte factor-1 (pref-1) is specifically expressed in preadipocytes and acts as a molecular gatekeeper of adipogenesis. In the present study, we investigated the fat depot-specific differences in telomere length and pref-1 gene expression in various anatomical sites (subcutaneous, intramuscular and visceral) of fattening Wagyu cattle. Visceral adipose tissue expressed higher pref-1 mRNA than did subcutaneous and intramuscular adipose tissues. The telomere length in visceral adipose tissue tended to be longer than that of subcutaneous and intramuscular adipose tissues. The telomere length of adipose tissue was not associated with adipocyte size from three anatomical sites. No significant correlation was found between the pref-1 mRNA level and the subcutaneous adipocyte size. In contrast, the pref-1 mRNA level was negatively correlated with the intramuscular and visceral adipocyte size. These results suggest that anatomical sites of adipose tissue affect the telomere length and expression pattern of the pref-1 gene in a fat depot-specific manner. - Highlights: • Visceral adipose tissue express higher pref-1 mRNA than other anatomical sites. • Telomere length in visceral adipose tissue is longer than other anatomical sites. • Telomere length of adipose tissue is not associated with adipocyte size. • Pref-1 mRNA is negatively correlated with intramuscular and visceral adipocyte size.

60 APPLIED LIFE SCIENCES↗

A new indanedione derivative alleviates symptoms of diabetes by modulating RAGE-NF-kappaB pathway in db/db mice

Highlights: • A new derivative of indanedione diminished oxidative stress and restored function of liver and fat cells. • IDD-24 reduced serum glycotoxins and improved glucose metabolism in diabetic mice. • Indanedione derivative improved hypoadiponectinemia, and insulin resistance in diabetic mice. Accumulating evidence indicates that a number of tissues are damaged due to build-up of abnormal amount of Advanced Glycation End products (AGEs) in several diseases including diabetes. Currently AGE inhibitors are scarce in clinical use indicating a need for development of new anti-AGE agents. The aim of the current study is to identify the new AGE inhibitors and to decipher their mechanism of action for alleviating symptoms of diabetes in mice. Among several derivatives, one of the derivatives of indanedione, IDD-24 demonstrated highest inhibition of AGE formation and AGE mediated reactive oxygen species production in HepG-2 and mature 3T3-L1 adipocytes. In mice treated with IDD-24, reduction in serum AGE formation and expression of Receptor for AGEs (RAGE) was seen in IDD-24 treated db/db mice. In vivo, glycogen synthesis was also increased in muscle tissue. In adipocytes, anti-AGE agent restored AGEs' induced diminished glucose uptake in fat cells. Mice treated with IDD-24 exhibited increased glucose tolerance, increaed serum adiponectin levels and decreased insulin resistance. Deciphering mechanism of IDD-24 in diabetic mice, it was observed that nuclear factor-κB (NF-κB) and serine phosphorylation of Insulin receptor substrate-1 (IRS-1) declined, while diminished activation of c-Jun NH2-terminal kinase (JNK) appears to be partly responsible for restoration of insulin signaling. We conclude that IDD-24 can be a possible treatment target to address symptoms of diabetes.

60 APPLIED LIFE SCIENCES↗

Metals in tissues of migrant semipalmated sandpipers (Calidris pusilla) from Delaware Bay, New Jersey

There is an abundance of field data on levels of metals for feathers in a variety of birds, but relatively few data for tissues, especially for migrant species from one location. In this paper we examine the levels of arsenic, cadmium, chromium, lead, manganese, mercury and selenium in muscle, liver, brain, fat and breast feathers from migrant semipalmated sandpipers (Calidris pusilla) collected from Delaware Bay, New Jersey. Our primary objectives were to (1) examine variation as a function of tissue, (2) determine the relationship of metal levels among tissues, and (3) determine the selenium:mercury molar ratio in different tissues since selenium is thought to protect against mercury toxicity. We were also interested in whether the large physiological changes that occur while shorebirds are on Delaware Bay (e.g. large weight gains in 2–3 weeks) affected metal levels, especially in the brain. There were significant differences among tissues for all metals. The brain had the lowest levels of arsenic and cadmium, and was tied for the lowest levels of all other metals except lead and selenium. Correlations among metals in tissues were varied, with mercury levels being positively correlated for muscle and brain, and for liver and breast feathers. Weights vary among individuals at the Delaware Bay stopover, as they arrive light, and gain weight prior to migration north. Bird weight and levels of arsenic, cadmium, and selenium in the brain were negatively correlated, while they were positively correlated for lead. There was no positive correlation for mercury in the brain as a function of body weight. The selenium:mercury molar ratio varied significantly among tissues, with brain (ratio of 141) and fat having the highest ratios, and liver and breast feathers having the lowest. In all cases, the ratio was above 21, suggesting the potential for amelioration of mercury toxicity. - Highlights: • Metal levels were examined for migrant semipalmated sandpipers. • There were differences in metal levels among internal tissues. • Brain had the lowest levels of arsenic and cadmium. • Bird weight and arsenic, cadmium, and selenium levels in brain were negatively correlated. • Selenium:mercury molar ratio varied among tissues (21–141, suggesting protection)

54 ENVIRONMENTAL SCIENCES↗

Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy

Purpose: To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. Methods: The DEQCT method was applied to 80/140 kVp images of patient-simulating lumbar sectional body phantoms of three sizes (small, medium, and large). External calibration rods of bone, red marrow, and fat-simulating materials were placed beneath the body phantoms. Similar internal calibration inserts were placed at vertebral locations within the body phantoms. Six test inserts of known volume fractions of bone, fat, and red marrow were also scanned. External-to-internal calibration correction factors were derived. The effects of body phantom size, radiation dose, spongiosa region segmentation granularity [single (∼17 × 17 mm) region of interest (ROI), 2 × 2, and 3 × 3 segmentation of that single ROI], and calibration method on the accuracy of the calculated volume fractions of red marrow (cellularity) and trabecular bone were evaluated. Results: For standard low dose DEQCT x-ray technique factors and the internal calibration method, the RMS errors of the estimated volume fractions of red marrow of the test inserts were 1.2–1.3 times greater in the medium body than in the small body phantom and 1.3–1.5 times greater in the large body than in the small body phantom. RMS errors of the calculated volume fractions of red marrow within 2 × 2 segmented subregions of the ROIs were 1.6–1.9 times greater than for no segmentation, and RMS errors for 3 × 3 segmented subregions were 2.3–2.7 times greater than those for no segmentation. Increasing the dose by a factor of 2 reduced the RMS errors of all constituent volume fractions by an average factor of 1.40 ± 0.29 for all segmentation schemes and body phantom sizes; increasing the dose by a factor of 4 reduced those RMS errors by an average factor of 1.71 ± 0.25. Results for external calibrations exhibited much larger RMS errors than size matched internal calibration. Use of an average body size external-to-internal calibration correction factor reduced the errors to closer to those for internal calibration. RMS errors of less than 30% or about 0.01 for the bone and 0.1 for the red marrow volume fractions would likely be satisfactory for human studies. Such accuracies were achieved for 3 × 3 segmentation of 5 mm slice images for: (a) internal calibration with 4 times dose for all size body phantoms, (b) internal calibration with 2 times dose for the small and medium size body phantoms, and (c) corrected external calibration with 4 times dose and all size body phantoms. Conclusions: Phantom studies are promising and demonstrate the potential to use dual energy quantitative CT to estimate the spatial distributions of red marrow and bone within the vertebral spongiosa.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-141: Comparison of Dose Calculation On Automatically Generated MRBased ED Maps and Corresponding Patient CT for Clinical Prostate EBRT Plans

Purpose: To analyze the effect of computing radiation dose on automatically generated MR-based simulated CT images compared to true patient CTs. Methods: Six prostate cancer patients received a regular planning CT for RT planning as well as a conventional 3D fast-field dual-echo scan on a Philips 3.0T Achieva, adding approximately 2 min of scan time to the clinical protocol. Simulated CTs (simCT) where synthesized by assigning known average CT values to the tissue classes air, water, fat, cortical and cancellous bone. For this, Dixon reconstruction of the nearly out-of-phase (echo 1) and in-phase images (echo 2) allowed for water and fat classification. Model based bone segmentation was performed on a combination of the DIXON images. A subsequent automatic threshold divides into cortical and cancellous bone. For validation, the simCT was registered to the true CT and clinical treatment plans were re-computed on the simCT in pinnacle{sup 3}. To differentiate effects related to the 5 tissue classes and changes in the patient anatomy not compensated by rigid registration, we also calculate the dose on a stratified CT, where HU values are sorted in to the same 5 tissue classes as the simCT. Results: Dose and volume parameters on PTV and risk organs as used for the clinical approval were compared. All deviations are below 1.1%, except the anal sphincter mean dose, which is at most 2.2%, but well below clinical acceptance threshold. Average deviations are below 0.4% for PTV and risk organs and 1.3% for the anal sphincter. The deviations of the stratifiedCT are in the same range as for the simCT. All plans would have passed clinical acceptance thresholds on the simulated CT images. Conclusion: This study demonstrated the clinical usability of MR based dose calculation with the presented Dixon acquisition and subsequent fully automatic image processing. N. Schadewaldt, H. Schulz, M. Helle and S. Renisch are employed by Phlips Technologie Innovative Techonologies, a subsidiary of Royal Philips NV.

60 APPLIED LIFE SCIENCES↗

SU-E-J-219: A Dixon Based Pseudo-CT Generation Method for MR-Only Radiotherapy Treatment Planning of the Pelvis and Head and Neck

Purpose: To develop an image processing method for MRI-based generation of electron density maps, known as pseudo-CT (pCT), without usage of model- or atlas-based segmentation, and to evaluate the method in the pelvic and head-neck region against CT. Methods: CT and MRI scans were obtained from the pelvic region of four patients in supine position using a flat table top only for CT. Stratified CT maps were generated by classifying each voxel based on HU ranges into one of four classes: air, adipose tissue, soft tissue or bone.A hierarchical region-selective algorithm, based on automatic thresholding and clustering, was used to classify tissues from MR Dixon reconstructed fat, In-Phase (IP) and Opposed-Phase (OP) images. First, a body mask was obtained by thresholding the IP image. Subsequently, an automatic threshold on the Dixon fat image differentiated soft and adipose tissue. K-means clustering on IP and OP images resulted in a mask that, via a connected neighborhood analysis, allowing the user to select the components corresponding to bone structures.The pCT was estimated through assignment of bulk HU to the tissue classes. Bone-only Digital Reconstructed Radiographs (DRR) were generated as well. The pCT images were rigidly registered to the stratified CT to allow a volumetric and voxelwise comparison. Moreover, pCTs were also calculated within the head-neck region in two volunteers using the same pipeline. Results: The volumetric comparison resulted in differences <1% for each tissue class. A voxelwise comparison showed a good classification, ranging from 64% to 98%. The primary misclassified classes were adipose/soft tissue and bone/soft tissue. As the patients have been imaged on different table tops, part of the misclassification error can be explained by misregistration. Conclusion: The proposed approach does not rely on an anatomy model providing the flexibility to successfully generate the pCT in two different body sites. This research is founded by ZonMw IMDI Programme, project name: “RASOR sharp: MRI based radiotherapy planning using a single MRI sequence”, project number: 10-104003010.

60 APPLIED LIFE SCIENCES↗

Intercostal high intensity focused ultrasound for liver ablation: The influence of beam shaping on sonication efficacy and near-field risks

Purpose: One of the major issues in high intensity focused ultrasound ablation of abdominal lesions is obstruction of the ultrasound beam by the thoracic cage. Beam shaping strategies have been shown by several authors to increase focal point intensity while limiting rib exposure. However, as rib obstruction leaves only part of the aperture available for energy transmission, conserving total emitted acoustic power, the intensity in the near-field tissues inherently increases after beam shaping. Despite of effective rib sparing, those tissues are therefore subjected to increased risk of thermal damage. In this study, for a number of clinically representative intercostal sonication geometries, modeling clinically available hardware, the effect of beam shaping on both the exposure of the ribs and near-field to acoustic energy was evaluated and the implications for the volumetric ablation rate were addressed. Methods: A relationship between rib temperature rise and acoustic energy density was established by means of in vivo MR thermometry and simulations of the incident acoustic energy for the corresponding anatomies. This relationship was used for interpretation of rib exposure in subsequent numerical simulations in which rib spacing, focal point placement, and the focal point trajectory were varied. The time required to heat a targeted region to 65 °C was determined without and with the application of beam shaping. The required sonication time was used to calculate the acoustic energy density at the fat–muscle interface and at the surface of the ribs. At the fat–muscle interface, exposure was compared to available literature data and rib exposure was interpreted based on the earlier obtained relation between measured temperature rise and simulated acoustic energy density. To estimate the volumetric ablation rate, the cool-down time between periods of energy exposure was estimated using a time-averaged power limit of 100 kJ/h. Results: At the level of the ribs, the temperature rise–energy density proportionality constant was estimated to be 6.0–7.6 °C/(J/mm{sup 2}). Beam shaping by the geometric shadow method typically reduces the acoustic intensity a factor of 2, considering the 1 cm{sup 2} with the highest exposure. For a 4 mm diameter circular sonication trajectory, the near-field energy limit of 2.5 J/mm{sup 2} was exceeded for all considered geometries. The estimated rib temperature was in all but one (sonication 50 mm behind the ribs, with 15 mm rib spacing and a 4 mm diameter circular sonication trajectory) of the considered scenarios within acceptable limits. For those sonication scenarios where a single sonication is considered safe both in terms of near-field as well as rib heating, volumetric ablation rates in the order of 1 ml/h are estimated. Conclusions: Intercostal sonication is associated with an increased risk of near-field overheating. This risk is strongly dependent on the considered rib spacing, the placement of the focus behind the ribs, and the selected sonication trajectory. For the hardware under simulation, obstruction by the thoracic cage renders ablations of clinically relevant volumes within a practical time-frame unfeasible in a large part of the liver. Improvements maybe expected from transducer designs with a larger active surface and/or nonlinear sonication strategies.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-04: Feature Selection and Clustering Optimization for Pseudo-CT Generation in MR-Based Attenuation Correction and Radiation Therapy Planning

Purpose: Accurate and robust photon attenuation derived from MR is essential for PET/MR and MR-based radiation treatment planning applications. Although the fuzzy C-means (FCM) algorithm has been applied for pseudo-CT generation, the input feature combination and the number of clusters have not been optimized. This study aims to optimize both for clinically practical pseudo-CT generation. Methods: Nine volunteers were recruited. A 190-second, single-acquisition UTE-mDixon with 25% (angular) sampling and 3D radial readout was performed to acquire three primitive MR features at TEs of 0.1, 1.5, and 2.8 ms: the free-induction-decay (FID), the first and the second echo images. Three derived images, Dixon-fat and Dixon-water generated by two-point Dixon water/fat separation, and R2* (1/T2*) map, were also created. To identify informative inputs for generating a pseudo-CT image volume, all 63 combinations, choosing one to six of the feature images, were used as inputs to FCM for pseudo-CT generation. Further, the number of clusters was varied from four to seven to find the optimal approach. Mean prediction deviation (MPD), mean absolute prediction deviation (MAPD), and correlation coefficient (R) of different combinations were compared for feature selection. Results: Among the 63 feature combinations, the four that resulted in the best MAPD and R were further compared along with the set containing all six features. The results suggested that R2* and Dixon-water are the most informative features. Further, including FID also improved the performance of pseudo-CT generation. Consequently, the set containing FID, Dixon-water, and R2* resulted in the most accurate, robust pseudo-CT when the number of cluster equals to five (5C). The clusters were interpreted as air, fat, bone, brain, and fluid. The six-cluster Result additionally included bone marrow. Conclusion: The results suggested that FID, Dixon-water, R2* are the most important features. The findings can be used to facilitate pseudo-CT generation for unsupervised clustering. Please note that the project was completed with partial funding from the Ohio Department of Development grant TECH 11-063 and a sponsored research agreement with Philips Healthcare that is managed by Case Western Reserve University. As noted in the affiliations, some of the authors are Philips employees.

60 APPLIED LIFE SCIENCES↗

Generation of brain pseudo-CTs using an undersampled, single-acquisition UTE-mDixon pulse sequence and unsupervised clustering

Purpose: MR-based pseudo-CT has an important role in MR-based radiation therapy planning and PET attenuation correction. The purpose of this study is to establish a clinically feasible approach, including image acquisition, correction, and CT formation, for pseudo-CT generation of the brain using a single-acquisition, undersampled ultrashort echo time (UTE)-mDixon pulse sequence. Methods: Nine patients were recruited for this study. For each patient, a 190-s, undersampled, single acquisition UTE-mDixon sequence of the brain was acquired (TE = 0.1, 1.5, and 2.8 ms). A novel method of retrospective trajectory correction of the free induction decay (FID) signal was performed based on point-spread functions of three external MR markers. Two-point Dixon images were reconstructed using the first and second echo data (TE = 1.5 and 2.8 ms). R2{sup ∗} images (1/T2{sup ∗}) were then estimated and were used to provide bone information. Three image features, i.e., Dixon-fat, Dixon-water, and R2{sup ∗}, were used for unsupervised clustering. Five tissue clusters, i.e., air, brain, fat, fluid, and bone, were estimated using the fuzzy c-means (FCM) algorithm. A two-step, automatic tissue-assignment approach was proposed and designed according to the prior information of the given feature space. Pseudo-CTs were generated by a voxelwise linear combination of the membership functions of the FCM. A low-dose CT was acquired for each patient and was used as the gold standard for comparison. Results: The contrast and sharpness of the FID images were improved after trajectory correction was applied. The mean of the estimated trajectory delay was 0.774 μs (max: 1.350 μs; min: 0.180 μs). The FCM-estimated centroids of different tissue types showed a distinguishable pattern for different tissues, and significant differences were found between the centroid locations of different tissue types. Pseudo-CT can provide additional skull detail and has low bias and absolute error of estimated CT numbers of voxels (−22 ± 29 HU and 130 ± 16 HU) when compared to low-dose CT. Conclusions: The MR features generated by the proposed acquisition, correction, and processing methods may provide representative clustering information and could thus be used for clinical pseudo-CT generation.

60 APPLIED LIFE SCIENCES↗

Utilization of [14C]phenylalanine derived from arylphorin or free amino acid in Manduca sexta pharate adults

The role of arylphorin as a storage protein was studied using 14C-arylphorin. 14C-arylphorin was produced optimally by incubating one-half fat body from Manduca sexta fifth instar larvae at 22 degrees C for 24 h, in 1 ml of medium containing amino acids at 25% of their physiological concentration with [U-14C]-phenylalanine (phe) provided initially without nonlabeled phenylalanine. Nonlabeled phe was provided after 1 h at 16% of its physiological concentration. The specific activity of 14C-arylphorin produced in vitro was 30 times greater than that generated in vivo. Injection of 14C-arylphorin into pharate adults was used to study the distribution of 14C-phe derived from this protein into 14CO2 and tissues for comparison with injection of free 14C-phe during the middle (days 6 to 12 pharate adult) and late (days 12 to 17 pharate adult) stages of adult development. Appearance of 14CO2 from 14C-arylphorin as compared to 14C-phenylalanine showed a slower time course during both the middle and late stages of development, in keeping with the time needed for degradation of the protein. In accord with faster phe turnover near the end of adult development, total 14CO2 production was greater and the retention of 14C in hemolymph and fat body was less compared to the middle stage of development regardless of whether 14C-arylphorin or 14C-phe was injected. In the middle stage of development, the appearance of 14C in the cuticle and head parts was greater, whereas incorporation into abdomen and thorax was less than during the late stage of development. Since the pattern of 14C distribution from 14C-arylphorin and 14C-phe was similar, one major function of arylphorin must be as a storage protein replenishing the supply of free amino acids used for synthesis of adult tissues. These results also suggest a limited contribution of M. sexta arylphorin to formation of the cuticle subsequent to day-6 pharate adult.

Non-NASA Center↗

Temporal expression and immunogold localization of Plodia interpunctella granulosis virus structural proteins

Monospecific antisera were produced against four structural proteins (VP12, VP17, VP31, and granulin) of the Plodia interpunctella granulosis virus using polypeptides derived by sodium dodecyl sulfate-polyacrylamide gel electrophoresis or acid extraction. The antisera were shown to be specific on immunoblots of SDS-PAGE separated granulosis virus and were further used to detect structural proteins in infected fat body lysates. Immunoblots of fat body lysates from early stages of infection indicated that VP12, VP17, VP31, and granulin were expressed by 2.5 days post-infection. Immunogold labeling of the virus using the monospecific antisera and electron microscopy confirmed earlier reports that granulin is located in the protein matrix, V17 is an envelope protein, and VP31 is a capsid protein.

Non-NASA Center↗

Thick branes in extra dimensions and suppressed dark couplings

The nature of dark matter (DM) and how it may interact with the various fields of the Standard Model (SM) remains a mystery. In this paper we show that the interaction between new light dark matter mediators and the SM particles can be naturally suppressed if one employs a single, flat extra dimension (ED). In this setup, the SM fields are localized in a finite width ‘fat’ brane, similar to models of Universal Extra Dimensions (UED), while DM, in turn, is confined to a thin brane at the opposite end of the ED interval. Including brane localized kinetic terms on the fat brane for the mediator fields, the resulting coupling between the SM and these light mediators can be several orders of magnitude smaller than the corresponding ones between the mediators and DM which we assume to be a typical gauge coupling. We investigate the implications of this scenario for both vector (i.e, dark photon, DP) and scalar mediator fields in the 5-D bulk. In this setup kinetic mixing, which is usually employed to suppress light mediator couplings, is not required. Here we assume that the SM particles couple to the DP via their B - L charges while the DP couples to the DM via a dark charge. Both the vector DP couplings and the corresponding Higgs portal couplings with the SM are shown to be natural small in magnitude with a size dependent on ratio of the 5-D compactification radius, R -1 ~ 0.1-1 GeV, and the SM brane thickness, L -1 ~ 2-10 TeV, a range chosen to avoid LHC and other experimental constraints. In this framework one can obtain the observed value of the DM relic abundance for a wide range of parameter choices, while the constrains due to direct DM detection and the invisible width of the Higgs do not impose significant challenges to the model. Finally, this mechanism can lead to distinct signatures in both present and upcoming experiments as it combines some common features of UED and DP models in a single ED setup.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting a boosted diboson resonance

New light scalar particles in the mass range of hundreds of GeV, decaying into a pair of W/Z bosons can appear in several extensions of the SM. The focus of collider studies for such a scalar is often on its direct production, where the scalar is typically only mildly boosted. The observed W/Z are therefore well-separated, allowing analyses for the scalar resonance in a standard fashion as a low-mass diboson resonance. In this work we instead focus on the scenario where the direct production of the scalar is suppressed, and it is rather produced via the decay of a significantly heavier (a few TeV mass) new particle, in conjunction with SM particles. Such a process results in the scalar being highly boosted, rendering the W/Z’s from its decay merged. The final state in such a decay is a “fat” jet, which can be either four pronged (for fully hadronic W/Z decays), or may be like a W/Z jet, but with leptons buried inside (if one of the W/Z decays leptonically). In addition, this fat jet has a jet mass that can be quite different from that of the W/Z/Higgs/top quark-induced jet, and may be missed by existing searches. In this work, we develop dedicated algorithms for tagging such multi-layered “boosted dibosons” at the LHC. As a concrete application, we discuss an extension of the standard warped extra dimensional framework where such a light scalar can arise. We demonstrate that the use of these algorithms gives sensitivity in mass ranges that are otherwise poorly constrained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating the structural complexity of isomeric bile acids with ion mobility spectrometry

Bile acids (BAs) play an integral role in digestion through the absorption of nutrients, emulsification of fats and fat-soluble vitamins, and maintenance of cholesterol levels. Metabolic disruption, diabetes, colorectal cancer, and numerous other diseases have been linked with BA disruption, making improved BA analyses essential. To date, most BA measurements are performed using liquid chromatography separations in conjunction with mass spectrometry measurements (LC-MS). However, 10–40 min LC gradients are often used for BA analyses and these may not even be sufficient for distinguishing all the important isomers present in the human body. Ion mobility spectrometry (IMS) is a promising tool for BA evaluations due to its ability to quickly separate isomeric molecules with subtle structural differences. In this study, we utilized drift tube IMS (DTIMS) coupled with MS to characterize 56 different unlabeled BA standards and 16 deuterated versions. In the DTIMS-MS analyses of 12 isomer groups, BAs with smaller m/z values were easily separated in either their deprotonated or sodiated forms (or both). However, as the BAs grew in m/z value, they became more difficult to separate with two isomer groups being inseparable. Metal ions such as copper and zinc were then added to the overlapping BAs, and due to different binding sites, the resulting complexes were separable. Thus, the rapid structural measurements possible with DTIMS-MS show great potential for BAs measurements with and without prior LC separations.

Zheng, Xueyun↗

Duodenal obstruction induced by retroperitoneal progression of bladder cancer: a report of two cases

Bladder cancer usually forms a papillary structure. Progression along the cavity or membranous structures surrounding the bladder, rectum, or retroperitoneum without formation of a discrete mass is rare. We here present two patients with duodenal obstruction caused by retroperitoneal progression of bladder cancer, in both of whom computed tomography revealed bladder and rectal wall thickening with a malignant target sign, thickened mesorectal fascia with abnormal tissue stranding, and increased perirectal fat density. Both cancers progressed despite treatment, as indicated by faint abnormal tissue stranding and increased retroperitoneal fat density along the retromesenteric plane from the pelvis to the duodenum. Subsequently, both patients developed obstruction in the horizontal portion of the duodenum, still without formation of a mass lesion. These two patients highlight the challenges associated with retroperitoneal invasion by bladder cancer in the absence of a mass lesion and underscore the importance of considering cancer progression in patients with bowel obstruction, even when there is no obvious mass lesion and/or only minor retroperitoneal findings. Progression along the retromesenteric plane may be the key pathway via which progressive bladder cancer results in duodenal obstruction without or with a minor mass lesion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ischiorectal fossa: benign and malignant neoplasms of this “ignored” radiological anatomical space

Purpose: To review the pertinent anatomy and the imaging features of common and uncommon benign and malignant neoplasms and masses of the ischiorectal fossa. Results: The ischiorectal or ischioanal fossa is the largest space in the anorectal region. The benign neoplasms that develop in the ischiorectal originate from the different components that forms the fossa including vascular tumors such as aggressive angiomyxoma or hemangioma; neural tumors as plexiform neurofibroma or schwannoma; fat tumors as lipoma; skin/skin appendages tumors as hidradenoma papilliferum; smooth or skeletal muscle tumors as solitary fibrous tumor. The malignant neoplasms that develop in the ischiorectal fossa also originate from different components that forms the fossa including vascular tumors such as angiosarcoma, neural tumors as malignant granular cell tumor and malignant peripheral nerve sheath tumor; fat tumors as liposarcoma; smooth or skeletal muscle tumors as leiomyosarcoma, rhabdomyosarcoma, malignant PEComa, or undifferentiated pleomorphic sarcoma. Additionally, the ischiorectal fossa can also harbor secondary hematogenous metastases and be affected by direct invasion from neoplasms of adjacent pelvic organs and structures. Furthermore, other miscellaneous masses can occur in the ischiorectal fossa including congenital and developmental lesions, and inflammatory and infectious processes. Conclusion: Knowledge of the anatomy, and the spectrum of imaging findings of common and uncommon benign and malignant neoplasms of the ischiorectal fossa is crucial for the radiologists during interpretation of images allowing them to make contributions to the diagnosis and better patient management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗