Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLAMMABILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Evaluation of Hydrogen Gas Generation and Permeation in the 9979 Type AF Shipping Package

The 9979 Type AF Shipping Packaging is a cost-effective radioactive material package designed by Savannah River National Laboratory (SRNL) that consists of two primary components: a foamed outer drum for structural protection and an inner containment drum. The packaging was designed to transport Highly Enriched Uranium (HEU), Low Enriched Uranium (LEU), and other isotopes not exceeding a Type A quantity. These contents have the potential to generate flammable hydrogen gas during transport due to the degradation of hydrogenous materials (e.g. water vapor, plastics, etc) by high-energy alpha radiation. Since 10 CFR 71.43(h) prohibits the incorporation of packaging features explicitly designed for continuous venting, alternative justification was required to demonstrate that the requirements of 10 CFR 71.43(d) for negligible reactions between packaging components and contents were satisfied. An analysis was performed to demonstrate that the potential for hydrogen gas generation over a one-year period was limited by the effects of permeation through the packaging materials. The rate of hydrogen collection was evaluated for both the inner containment drum and the outer structural drum under 10 CFR 71.71 Normal Conditions of Transport (NCT). The analysis concludes that the Lower Flammability Limit (LFL) for hydrogen gas will not be reached in a one-year shipping period assuming a minimum void volume is maintained within the drum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Risk Assessment and Ventilation Modeling for Hydrogen Release in Vehicle Repair Garages

The availability of repair garage infrastructure for hydrogen fuel cell vehicles is becoming increasingly important for future industry growth. Ventilation requirements for hydrogen fuel cell vehicles can affect both retrofitted and purpose-built repair garages and the costs associated with these requirements can be significant. A hazard and operability study (HAZOP) was performed to identify key risk-significant scenarios related to hydrogen vehicles in a repair garage. Detailed simulations and modeling were performed using appropriate computational tools to estimate the location, behavior, and severity of hydrogen release based on key HAZOP scenarios. This work compares current fire code requirements to an alternate ventilation strategy to further reduce potentially hazardous conditions. Overall, the amount of flammable mass of hydrogen at any one time in the simulation is low compared to the total mass of hydrogen released, due to the low flow rate of a low pressure release. It is shown that position, direction, and velocity of ventilation have a significant impact on the amount of instantaneous flammable mass in the domain.

33 ADVANCED PROPULSION SYSTEMS↗

Ghostbusters for Batteries

End of life batteries (EOLBs) present a cost and safety liability for their owners and stakeholders. This is due flammability, energy, and power with EOLBs. Current approaches include cumbersome, expensive packaging, specialized shipping, regulated storage, and they are responsible for over half of the cost of recycling. They all expensively and inadequately address symptoms. OnTo has developed and proven a simple way to resolve the problem systemically, through depowering of lithium-ion batteries (and most any battery other than lead). The low-cost process removes flammability, power, and energy in EOLBs through non-toxic chemical processing. The opportunity for commerce of inert scrap is at least $5 billion greater than the commerce in hazardous scrap, all made possible through OnTo’s technology for efficiency and safety.

25 ENERGY STORAGE↗

A Review of the Literature on the Radiolytic Stability of the Next-Generation Solvent

The Original Caustic-Side Solvent Extraction (CSSX) solvent (based on the BOBCalixC6 extractant) currently in use at the Salt Waste Processing Facility (SWPF) is set to be replaced by the Next-Generation Solvent (NGS, based on the MaxCalix extractant). Current SWPF flammability safety controls use G-values for volatile gases obtained from radiolysis studies with the Original CSSX solvent. A review of past irradiation tests of both solvent systems was performed to assess the radiolytic stability of NGS with respect to flammable gas generation from radiolysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MIS Shelf-Life Final Report for Plutonium Oxide Item 1000089 (SSR136 and SSR136A) from Rocky Flats Peroxide Precipitation and Calcination Process

A plutonium dioxide material from the Material Identification and Surveillance (MIS) Program inventory has been studied to determine the gas generation and corrosion behavior in a storage environment. Sample 1000089 represents product-quality plutonium oxides produced in the Rocky Flats peroxide precipitation process currently stored in 3013 containers. This study followed over time the gas pressure and composition of a sample with nominally 0.5 wt% water in a sealed container with an internal volume scaled to 1/500th of the volume of a 3013 container. Gas compositions had been measured periodically over almost 13 years. The maximum observed gas pressure was 204 kPa and was related to a temperature excursion. The maximum observed gas pressure from gas generation was 126 kPa. The increase over the initial pressure of 86.7 kPa was due to the generation of hydrogen, oxygen, and nitrogen. Carbon dioxide, methane and carbon monoxide were minor components of the headspace gas. The material exhibited unusual behavior in that the atmosphere reached flammable levels of hydrogen and oxygen within the first 30 days and remained flammable for the duration of the experiment. It has been determined that the sample inside the reactor was a mixture of the AR material, material calcined at 800 °C, and material calcined at 950 °C. The experiment was terminated in 2012 and unloaded in 2016. A new reactor, SSR136A, was loaded with the original sample freshly calcined at 950 °C. The total pressure inside SSR136A remained close to the initial value of 93 kPa. The total pressure is composed of He (steady levels after the reloading) and hydrogen which is 10% of the reactor’s total pressure. Nitrogen and oxygen compose trace amounts of the reactor headspace. The internal components of SSR136 were inspected in 2021, five years after it was removed from the array. The inside surfaces of the inner bucket exposed to the original sample for 4,576 days had an etched appearance, and pit-like features were observed in the microscopic analysis. No corrosion was observed on the SSR136A inner bucket that held the freshly calcined sample that was exposed for 1,303 days.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling DOE Standard Canister Configurations with Updated Surface Chemistry

Road-ready and final disposition packaging configurations for the advanced test reactor (ATR) fuel currently specifies storage within helium backfilled DOE sealed standard canisters. The aluminum cladding of the ATR fuel contains an oxyhydroxide layer of boehmite/bayerite that generates hydrogen when subjected to irradiation. Understanding the effect of this hydrogen buildup over time to important for long term storage considerations. Previous modeling efforts have built a coupled CFD-chemical model to simulate the temperature gas phase concentrations within the DOE sealed standard canisters. These models have coupled the temperature conditions to both the gas phase radiolysis chemistry and the surface chemistry associated with the oxyhydroxide layer. Continued experimental work has identified trends for aluminum surrogate samples with oxyhydroxide layers for tests done at higher dose rates. At low initial doses a fast generation rate of hydrogen occurs which starts to roll over to a lower generation rate as the total dose applied in increased. A previous study created a small-scale chemical model was built to replicate a mini-canister surrogate system at SRNL as well as for the smaller capsule tests performed at INL. The previous iteration of the model utilized step function for its G-values for the hydrogen generation over a 200-year period. This model makes an update to the surface chemistry to account for theorized surface chemistry reactions allowing for oxygen to remain bounded to the oxyhydroxide layer. As additional experiments continue, the kinetic fits may be adjusted to adapt to new data. Three canister configurations are modeled – the base 18-inch, 15-foot DOR standard canister with 30 ATR fuel elements, an 18-inch, 10-foot DOE standard canister with 32 ATR fuel elements and a 24-inch, 10-foot DOE standard canister with 40 ATR fuel elements. In previous reports, the primary sensitivity of the canister conditions was identified as the decay heat of the fuel and the dried condition of the fuel. Only these parameters are studied in the report. For the nominal case with dried fuel, the hydrogen generation is only about 2%, so it is even less than the flammability limit if it were exposed to oxygen. For the densely packed 18-inch case the total hydrogen concentration is only around 4% with the nominal decay heat. For the densely packed 24-inch case the total hydrogen concentration is only 2.5%, roughly 20% higher than the original packing design, and still under flammability conditions if exposed to oxygen.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Modeling of Advanced Test Reactor Fuel in a Generalized Dry Storage System Under Hypothetical Accident Conditions

Work was performed to investigate the thermal behavior of a sealed aluminum-clad spent nuclear fuel (ASNF) dry storage configuration under hypothetical accident conditions during long-term storage. The considered system consists of a concrete dry storage overpack; a welded over canister, backfilled with argon; and nine Department of Energy (DOE) standardized canisters (DOESCs) loaded with ASNF, backfilled with helium gas. One technical concern associated with the long-term storage of ASNF includes radiolytic hydrogen generation. The yield of large quantities of hydrogen could lead to DOESC over pressurization or a flammable internal atmosphere. While flammability concerns can be resolved by preventing the ingress of oxygen, the canister pressure is partially controlled by the atmosphere temperature. This memorandum summarizes the results of modeling and simulation (M&S) work completed with Star CCM+ (a computational fluid dynamics [CFD] software) considering the thermal effects of a fully engulfing flame and another scenario with the vent ports of the concrete dry storage overpack completely blocked. The goal was to determine the bounding maximum temperature of the DOESC internal atmosphere to evaluate a worst-case pressure scenario, as well as the critical vent port blockage durations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Safe Electrolytes for Batteries

The demand for reliable and safe lithium-ion batteries (LIBs) for electric vehicles (EVs) and energy storage systems (ESS) necessitates the exploration of nonflammable phosphorus-based electrolytes as alternatives to the traditional flammable carbonate-based ones. However, integrating phosphorus-based electrolyte poses challenges, including capacity fading and compatibility issues with graphite material. Here, a high-throughput (HTP) electrochemical characterization method, similar to PH test paper, is introduced to fast screen compatible phosphorus-based electrolyte for use with graphite. Among 1,740 combinations of phosphorus-based electrolytes and graphite materials, 101 promising combinations are identified for further evaluation. These identified phosphorus-based electrolytes and graphite materials are evaluated and optimized in Li/Graphite half-cells and Graphite/LiFePO 4 (LFP) full-cells using commercial-level electrodes. The desolvation energy of a complex with one Li+ and four solvent molecules of phosphate or carbonate is calculated by density functional theory (DFT). Key parameters such as viscosity, ionic conductivity, and flammability of the electrolytes are thoroughly tested and optimized. The modified phosphate-dominant electrolyte (2 M LiFSI TEP/DME/EC (6/2/2, volume ratio) + 5 wt.% VEC + 5 wt.% FEC) demonstrates excellent thermal stability with lithiated graphite and showcases superior cycling performance in the Graphite/LFP full cell, surpassing prior research findings in phosphate-dominant electrolytes. By the rapid HTP screening and identification of compatible electrolyte-graphite combinations, this approach contributes to expediting the development of safer LIBs for EVs and ESS.

25 ENERGY STORAGE↗

Summary of Gas Generation Behavior Observed in 3013 Surveillance and Monitoring Program Shelf-Life Experiments

Gas generation experiments have been conducted in small- and full-scale test containers at Los Alamos National Laboratory on samples of plutonium oxide material collected from plutonium processes across the DOE complex and tested at the bounding conditions for the Department of Energy 3013 Standard. The gas composition and pressures in the sealed experimental containers were measured over periods of months to years. These experiments have provided results for the formation and consumption of hydrogen and other gases. The conditions supporting the formation of flammable gas mixtures of hydrogen and oxygen in flammable gas mixtures were also determined. Different behaviors were observed between the materials tested based on their compositions, the stabilization performed on the material, and the post stabilization handling of the material. Many of the experiments are still ongoing. This report summarizes the results obtained for the gas generation behavior for high-purity plutonium oxides and salt-bearing impure plutonium oxides in sealed containers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Management of the Three Mile Island, Unit 2, Accident Corium and Severely Damaged Fuel Debris

The Three Mile Island, Unit Two (TMI-2) pressurized water reactor core melted down in 1979 due to an untimely combination of maintenance problems that led to a loss of feedwater, followed by a series of operational misunderstandings and errors. The melted core recovery process required development of a wide array of tools. After approximately three years of water management and other cleanup actions, the first views of the core revealed a much higher degree of damage than previously expected. Approximately 62 metric tons of the core had melted, leaving only 42 of the 177 fuel assemblies standing with a majority of rods intact. The core to be recovered was composed of loose debris and a solidified mass of formerly molten fuel. Robotic tools that had been designed for the task were of limited effectiveness due to the range of material types and phases. Over a period of several years, the central melt was broken up, primarily by use of a core-boring drill originally designed to acquire samples through the depth of the debris field. The broken pieces were loaded into specially designed debris canisters by use of long-handled pick-and-place tools and suctioned into baffled knockout canisters using an airlift vacuum system. A remotely operable underwater plasma arc torch was developed for removal of the lower core support structure to be able to retrieve the fuel pieces and secondary melt that had accumulated on the bottom reactor vessel head. Canister design played a central role in defining the initial retrieval process and later affected transportation, interim wet and its current interim dry storage. Due to concerns about the potential for radiolysis of residual water in the debris and other canister material, the canisters were fitted with hydrogen recombiner catalyst units to prevent a buildup of flammable gas and potential pressurization. To confirm the effectiveness of the recombiners during shipping, eight dewatered canisters were kept sealed for up to 205 days with periodic sampling of the headspace gas. The highest hydrogen value (9 vol%) was observed in a canister held for 147 days while the longest stored canister resulted in a 5% hydrogen concentration. The oxygen concentration never exceeded 0.5 %, and the primary backfill was >80% argon, meaning there was no flammability risk. Radiolytic hydrogen was also observed in wet pool storage, where the vented canisters discharged a portion of the water backfill as a result of gas production. The 344 canisters (268 fuel debris, 62 filter, and 12 knockout type) were dewatered, loaded in groups of seven into a double barrier shipping cask, and transported to the U.S. Department of Energy site in Idaho for 10 years of pool storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Space-Cabin Atmospheres: Part II - Fire and Blast Hazards. A Literature Review

The rapid evolution of aircraft and, lately, space vehicles has brought with it the ever-increasing difficulty of designing for prevention of fires and explosions. The present-day sealed cabin with its limited work space, unusual atmospheric constituents, and lack of flexibility in emergency situations has brought new and ill-defined hazards into the picture. In the past, numerous data have been compiled on the fire and explosion characteristics of all things combustible. Unfortunately, much of the material is not pertinent to the actual operational problems in space. The confusion and controversy arising from attempts to evaluate the space-cabin fire problem appear to stem from past failure to compile the scattered data and to expose it to critical review and selection. In the compilation that follows, an attempt has been made to review the best available data that was deemed actually pertinent to the present problem. The effects of unusual atmospheres have been emphasized, but, as will soon be evident, other physical parameters also play a major role in determining the nature of the problem. Chapter 1 contains a discussion of pertinent definitions and theory. This is detailed only to the point of anticipating some of the problems of interpretation that may arise in other chapters of the report. Included in this chapter is speculation on the impact of unusual environmental conditions such as aerodynamic heating, reduced gravitational acceleration, and low ambient pressures. Chapter 2 covers flammable fabrics and carbonaceous solids; Chapter 3, specific fire hazards involving flammable liquids, vapors, and gases; and Chapter 4, electrical fires. Chapter 5 covers the fire, blast, and flash hazards from meteoroid penetration; and Chapter 6, the problems of fire prevention and extinguishment in space cabins. Chapter 7 reviews the factors of fire and blast hazards in selection of a space-cabin atmosphere.

Roth, Emanuel M.↗

Circuit breaker cases

A flammable plastic part was duplicated dimensionally using a nonflammable material in place of the flammable plastic. The material used was L-3203-6 with a 16-hour post-cure at 400 F. Initial efforts were made to determine shrinkage tolerances required to produce a mold which would produce a finished, workable part. The final twenty-five circuit breaker cases were shipped and the metal inserts when installed, produced a workable breaker. Initial submissions of cases were rejected as lacking sufficient rigidity though they met all other requirements. The plastic cases weighed 16.5 grams, whereas the Refset cases weighed 17 grams, not meeting the less-weight requirement. The data on shrinkage determinations, and mold and part dimensions are shown. The method of manufacture is also reported.

Holmes, R. L.↗

Flame retardant treatments of PBI fabric.

Fabrics knitted or woven from polybenzimidazole (PBI) fibers were treated to reduce flammability in oxygen atmospheres, particularly that of 5 psia oxygen. Bromination to approximately 15% weight gain of such fabrics led to markedly lower burning rates; samples brominated to over 80% weight gain were self-extinguishing in 5 psia oxygen. The loss in tensile strength of fabrics due to bromination was negligible although shrinkage was observed. Free fibers showed negligible losses on bromination. Treatment of PBI fabric with organophosphorus compounds also achieved self-extinguishing character in 5 psia oxygen but the enhanced flameproofing was largely lost on leaching. Reaction with POCl3 in pyridine led to a permanent reduction in flammability.

Temin, S. C.↗

Analysis of volatile combustion products and a study of their toxicological effects.

An experimental program was conducted to study the thermochemical, flammability and toxicological characteristics of uncoated and coated polyisocyanurate foams. The coatings used were fluorinated copolymer and an intumescent material. Combustion and pyrolysis gases were analyzed by gas chromatography and mass spectrometry. The LD-50 and LD-100 tests were performed on Sprague-Dawley rats housed in an environmental chamber. The isocyanurate foam, fluorinated-copolymer-coated foam, and the intumescent-coated foam were found to have excellent flammability and insulation characteristics, although smoke development was substantial.

Seader, J. D.↗

Production development of organic nonflammable spacecraft potting, encapsulating and conformal coating compounds. Volume 3: Appendices

Appendices are presented which include: statement of work; material vendor contacts; formulation/processing data sheet; upward propagation test; flammability test conditions/results sheet; odor test; vacuum stability requirements; flammability test facility; determination of offgassing products and carbon monoxide test; and pneumatic and mechanical impact test guidelines.

Lieberman, S. L.↗

Predicted exhaust emissions from a methanol and jet fueled gas turbine combustor

A computer model of a gas turbine combustor has been used to predict the kinetic combustion and pollutant formation processes for methanol and simulated jet fuel. Use of the kinetic reaction mechanisms has also allowed a study of ignition delay and flammability limit of these two fuels. The NOX emissions for methanol were predicted to be from 69 to 92% lower than those for jet fuel at the same equivalence ratio which is in agreement with experimentally observed results. The high heat of vaporization of methanol lowers both the combustor inlet mixture temperatures and the final combustion temperatures. The lower combustion temperatures lead to low NOX emissions while the lower inlet mixture temperatures increase methanol's ignition delay. This increase in ignition delay dictates the lean flammability limit of methanol to be 0.8, while jet fuel is shown to combust at 0.4.

Adelman, H. G.↗

Experimental data for new fire-retardant materials

Report contains evaluations of flammability and physical properties of twenty-four upholstery and furnishing materials, such as those used in commercial aircraft. Data presented include degradation upon heating, limited oxygen indices, smoke generation, flammability afterglow, and char length.

Supkis, D. E.↗

Fire-resistant aircraft materials development and evaluation program

An aircraft flammability program was undertaken to utilize spacecraft developed fire-resistant materials to improve passenger safety and decrease losses from unattended fires in commercial aircraft. Five full-scale aircraft flammability tests were performed to evaluate the effectiveness of improved fire-resistant materials by comparing their burning characteristics with those of pre-1968 aircraft materials.

Bricker, R. W.↗