Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Positron emission mammography (PEM): Effect of activity concentration, object size, and object contrast on phantom lesion detection

Purpose: To characterize the relationship between lesion detection sensitivity and injected activity as a function of lesion size and contrast on the PEM (positron emission mammography) Flex Solo II scanner using phantom experiments. Methods: Phantom lesions (spheres 4, 8, 12, 16, and 20 mm diameter) were randomly located in uniform background. Sphere activity concentrations were 3 to 21 times the background activity concentration (BGc). BGc was a surrogate for injected activity; BGc ranged from 0.44-4.1 kBq/mL, corresponding to 46-400 MBq injections. Seven radiologists read 108 images containing zero, one, or two spheres. Readers used a 5-point confidence scale to score the presence of spheres. Results: Sensitivity was 100% for lesions {>=}12 mm under all conditions except for one 12 mm sphere with the lowest contrast and lowest BGc (60% sensitivity). Sensitivity was 100% for 8 mm spheres when either contrast or BGc was high, and 100% for 4 mm spheres only when both contrast and BGc were highest. Sphere contrast recovery coefficients (CRC) were 49%, 34%, 26%, 14%, and 2.8% for the largest to smallest spheres. Cumulative specificity was 98%. Conclusions: Phantom lesion detection sensitivity depends more on sphere size and contrast than on BGc. Detection sensitivity remained {>=}90% for injected activities as low as 100 MBq, for lesions {>=}8 mm. Low CRC in 4 mm objects results in moderate detection sensitivity even for 400 MBq injected activity, making it impractical to optimize injected activity for such lesions. Low CRC indicates that when lesions <8 mm are observed on PEM images they are highly tracer avid with greater potential of clinical significance. High specificity (98%) suggests that image statistical noise does not lead to false positive findings. These results apply to the 85 mm thick object used to obtain them; lesion detectability should be better (worse) for thinner (thicker) objects based on the reduced (increased) influence of photon attenuation.

60 APPLIED LIFE SCIENCES↗

Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid

Purpose: Medical linear accelerator mounted cone beam CT (CBCT) scanner provides useful soft tissue contrast for purposes of image guidance in radiotherapy. The presence of extensive scattered radiation has a negative effect on soft tissue visibility and uniformity of CBCT scans. Antiscatter grids (ASG) are used in the field of diagnostic radiography to mitigate the scatter. They usually do increase the contrast of the scan, but simultaneously increase the noise. Therefore, and considering other scatter mitigation mechanisms present in a CBCT scanner, the applicability of ASGs with aluminum interspacing for a wide range of imaging conditions has been inconclusive in previous studies. In recent years, grids using fiber interspacers have appeared, providing grids with higher scatter rejection while maintaining reasonable transmission of primary radiation. The purpose of this study was to evaluate the impact of one such grid on CBCT image quality. Methods: The grid used (Philips Medical Systems) had ratio of 21:1, frequency 36 lp/cm, and nominal selectivity of 11.9. It was mounted on the kV flat panel detector of an Elekta Synergy linear accelerator and tested in a phantom and a clinical study. Due to the flex of the linac and presence of gridline artifacts an angle dependent gain correction algorithm was devised to mitigate resulting artifacts. Scan reconstruction was performed using XVI4.5 augmented with inhouse developed image lag correction and Hounsfield unit calibration. To determine the necessary parameters for Hounsfield unit calibration and software scatter correction parameters, the Catphan 600 (The Phantom Laboratory) phantom was used. Image quality parameters were evaluated using CIRS CBCT Image Quality and Electron Density Phantom (CIRS) in two different geometries: one modeling head and neck and other pelvic region. Phantoms were acquired with and without the grid and reconstructed with and without software correction which was adapted for the different acquisition scenarios. Parameters used in the phantom study weret{sub cup} for nonuniformity and contrast-to-noise ratio (CNR) for soft tissue visibility. Clinical scans were evaluated in an observer study in which four experienced radiotherapy technologists rated soft tissue visibility and uniformity of scans with and without the grid. Results: The proposed angle dependent gain correction algorithm suppressed the visible ring artifacts. Grid had a beneficial impact on nonuniformity, contrast to noise ratio, and Hounsfield unit accuracy for both scanning geometries. The nonuniformity reduced by 90% for head sized object and 91% for pelvic-sized object. CNR improved compared to no corrections on average by a factor 2.8 for the head sized object, and 2.2 for the pelvic sized phantom. Grid outperformed software correction alone, but adding additional software correction to the grid was overall the best strategy. In the observer study, a significant improvement was found in both soft tissue visibility and nonuniformity of scans when grid is used. Conclusions: The evaluated fiber-interspaced grid improved the image quality of the CBCT system for broad range of imaging conditions. Clinical scans show significant improvement in soft tissue visibility and uniformity without the need to increase the imaging dose.

60 APPLIED LIFE SCIENCES↗

SU-E-J-138: An IGRT QA Device for Measuring with Tenths-Millimeter Accuracy KV and MV Isocenter Congruence, Couch Travel and Laser Alignment of Accelerators Used for SRS and SBRT

Purpose: To develop a practical device having sufficient accuracy for daily QA tests of accelerators used for SRS and SBRT. Methods: The UAB (Universal Alignment Ball) consists of a 6.35 mm (1/4 inch) diameter tungsten sphere located concentrically within a 25.4 mm (1 inch) diameter acrylic plastic (PMMA) sphere. The spheres are embedded in polystyrene foam, which, in turn, is surrounded by a cylindrical PMMA shell. The UAB is placed on the couch and aligned with wall lasers according to marks that have known positions in relation to the center of the spheres. Using planar and cone beam images the couch is shifted till the surface of the PMMA sphere matches Eclipse-generated circular contours. Anterior and lateral MV images taken with small MLC openings allow measurement of distance between kV and MV isocenter, laser and MLC alignment. Measurements were taken over a one-month period. Results: Artifacts from the tungsten sphere were confined within the PMMA sphere and did not affect cone beam localization of the sphere boundary, allowing 0.1 mm precise alignment with a computer-generated circle centered at kV isocenter. In tests extending over a one-month period, the distance between kV and MV isocenters along the vertical, longitudinal and lateral directions was 0.125 +/−0.06, 0.19 +/−0.08, and 0.02 +/−0.08 mm, respectively. Laser misalignment along these directions was 0.34 +/- 0.15, 0.74 +/−0.29, and 0.49 +/−0.22 mm. Automated couch shifts moved the spheres to within 0.1 mm of the selected position. The center of a 1cmx1cm MLC-defined field remained within +/−0.2 mm of the tungsten sphere center as the gantry was rotated. Conclusion: The UAB is practical for daily end-to-end QA tests of accelerator alignment. It provides tenths-mm accuracy for measuring agreement of kV and MV isocenters, couch motions, gantry flex and laser alignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-C-12A-01: Measurement of Skeletal Muscle Lipids in Type 2 Diabetes Using in Vivo Proton MR Spectroscopy

Purpose: To quantify and compare the intramyocellular (IMCL), extramyocellular (EMCL) lipids and total fat fraction in human vastus lateralis (VL) muscle between lean controls and type 2 diabetic (T2DM) subjects using long echo time in vivo proton MR spectroscopy ({sup 1}H-MRS) Methods: {sup 1}H-MRS single voxel (15 × 15 × 15 mm{sup 3}) stimulated acquisition mode (STEAM) was performed in right vastus lateralis m. on 10 lean controls (age: 28.3±3.94 yrs, BMI: 24.25±3.20 kg/m{sup 2}) and 7 type 2 diabetic (age: 54.28±6.42 yrs, BMI: 31.34±3.13 kg/m{sup 2}) subjects with Siemens 3T MRI and four-channel flex coil. Unsuppressed water spectra (NSA = 16) with TR/TE = 3000/30 msec, TM = 10 msec, BW = 2000 Hz, and water-suppressed spectra (NSA = 128) with TR/TE = 3000/270 msec, TM = 10 msec, and fixed water suppression BW = 50 Hz were acquired. Spectral intensity ratios of IMCL-CH{sub 2}, EMCL-CH{sub 2} and total lipid (IMCL {sub +} EMCL) with unsuppressed water signal (W) were converted into absolute concentrations expressed in mmol/kg. Fat fraction (100 × F/(W+F)) was calculated, where F includes the signal intensities of IMCL and EMCL methylene (CH{sub 2})n, peaks only. Results: Comparison of IMCL (controls: 11.70 ± 6.7, T2DM: 21.74 ± 10.2, p ≤ 0.01), EMCL (controls: 22.89 ± 18.42, T2DM: 77.21 ± 33.4, p ≤ 0.001) and total lipid (64.35 mmol/kg less in controls, p ≤ 0.001) showed statistical significance using two-tailed student t-test. Fat fraction (%) exhibited considerable inter-individual variability for controls (3.14 ± 2.09; range: 1.34 - 7.04) and T2DM (9.34 ± 2.88; range: 4.15 - 13.67) and deemed significant (p ≤ 0.05 Conclusion: Single voxel STEAM {sup 1}H-MRS at long TE provides a robust non-invasive method for characterizing lipids within localized muscle regions, with well-resolved IMCL/EMCL peak separation. Regional lipid estimate and fat fraction in VL m. was significantly different in T2DM compared to lean controls. American Heart Association Southwest Affiliate Pre-doctoral Fellowship.

60 APPLIED LIFE SCIENCES↗

SU-E-T-54: A New Method for Optimizing Radiation Isocenter for Linac-Based SRS

Purpose: To develop a new method to minimize deviation of linac x-ray beams from the centroid of the volumetric radiation isocenter for all combinations of gantry and table angle. Methods: A set of ball-bearing (Winston-Lutz) images was used to determine the gantry radiation isocenter as the midrange of deviation values. Deviations in the cross-plane direction were minimized by calibration of MLC leaf position offset, and by adjusting beam position steering for each energy. Special attention was also paid to matching the absolute position of isocenter across all energies by adjusting position steering in the gun-target axis. Displacement of table axis from the gantry isocenter, and recommended table axis adjustment for contemporary Elekta linacs, was also determined. Eight images were used to characterize the volumetric isocenter for the full range of gantry and table rotations available. Tabulation of deviation for each beam was used to test compliance with isocenter tolerance. Results: Four contemporary Elekta linacs were evaluated and the radius in the gun-target axis of the radiation isocenter was 0.5 to 0.7 mm. After beam steering adjustment, the radius in the cross-plane direction was typically 0.2 to 0.4 mm. Position matching between energies can be reduced to 0.28 mm. Maximum total deviation was 0.68 to 1.07 mm, depending primarily on the effect of systematic table axis wobble with rotation. Conclusion: This new method effectively facilitates minimization of deviation between beam center and target position. The test, which requires a few minutes to perform, can be easily incorporated into a routine machine QA program. A tighter radiation isocenter for contemporary Elekta linacs would require reducing the effect of gantry arm flex and/or table axis wobble that are the two main components of deviation from the designated isocenter point.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-E-06: Dosimetric Characterization of Small Photons Beams of a Novel Linear Accelerator

Purpose: The aim of the present contribution was to measure the main dosimetric quantities of small fields produced by UNIQUE and evaluate its matching with the corresponding dosimetric data of one 21EX conventional linear accelerator (Varian) in operation at the same center. The second step was to evaluate comparative performance of the EDGE diode detector and the PinPoint micro-ionization chamber for dosimetry of small fields. Methods: UNIQUE is configured with MLC (120 leaves with 0.5 cm leaf width) and a single low photon energy of 6 MV. Beam data were measured with scanning EDGE diode detector (volume of 0.019 mm{sup 3}), a PinPoint micro-ionization chamber (PTW) and for larger fields (≥ 4×4cm{sup 2}) a PTW Semi flex chamber (0.125 cm{sup 3}) was used. The scanning system used was the 3D cylindrical tank manufactured by Sun Nuclear, Inc. The measurement of PDD and profiles were done at 100 cm SSD and 1.5 depth; the relative output factors were measured at 10 cm depth. Results: PDD and the profile data showed less than 1% variation between the two linear accelerators for fields size between 2×2 cm{sup 2} and 5×5cm{sup 2}. Output factor differences was less than 1% for field sizes between 3×3 cm{sup 2} and 10×10 cm{sup 2} and less of 1.5 % for fields of 1.5×1.5 cm{sup 2} and 2×2 cm{sup 2} respectively. The dmax value of the EDGE diode detector, measured from the PDD, was 8.347 mm for 0.5×0,5cm{sup 2} for UNIQUE. The performance of EDGE diode detector was comparable for all measurements in small fields. Conclusion: UNIQUE linear accelerator show similar dosimetrics characteristics as conventional 21EX Varian linear accelerator for small, medium and large field sizes.EDGE detector show good performance by measuring dosimetrics quantities in small fields typically used in IMRT and radiosurgery treatments.

60 APPLIED LIFE SCIENCES↗

SU-F-T-232: Monthly Quality Assurance in External Beam Radiation Therapy Using a Single System

Purpose: Monthly quality assurance (QA) is time consuming for external beam radiation therapy, taking as long as 6–8 hours for each machine. It is due to the use and setup of multiple devices for different QA procedures. We have developed a single system with rotational capability for the measurement of both optical light and radiation which significantly reduces the time spent on Monthly QA. Methods: A single system using mirrors, a phosphor screen and a CCD camera is housed on a cylindrical motor so that it can rotate 360 degrees. For monthly QA, the system is placed on the patient couch of the medical accelerator with the plane of the phosphor screen at isocenter for all measurements. For optical QA such as optical distance indicator, room laser and light field, the optical image is collected directly with the camera. For radiation QA such as beam profile, MLC speed, picket-fence test, collimator rotation, table rotation and gantry rotation, a brass build-up plate is attached to the top of the phosphor screen. Two brass plates with islands of different thickness were designed for photon energy and electron energy constancy checks. Flex map, distortion map and uniformity map were developed to calibrate the motor bearing, camera/lens distortion, and the phosphor screen’s measured response across the field. Results: Following the TG142 guidelines for monthly QA with our system, the overall run time is reduced from 6–8 hours to 1.5 hours. Our system’s rotating design allows for quick testing of the gantry radiation isocenter test that is also independent of the sag of the gantry and the EPID. Conclusion: Our system significantly shortens the time needed for monthly QA by unifying the tests with a single system. Future work will be focused on extending the technology to Brachytherapy, IMRT and proton therapy QAs. This work is funded in part by a sponsor research grant from JPLC who owns the Raven technology. John Wong is a co-founder of JPLC.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-478: Effect of Deconvolution in Analysis of Mega Voltage Photon Beam Profiles

Purpose: To study and compare the penumbra of 6 MV and 15 MV photon beam profiles after deconvoluting different volume ionization chambers. Methods: 0.125cc Semi-Flex chamber, Markus Chamber and PTW Farmer chamber were used to measure the in-plane and cross-plane profiles at 5 cm depth for 6 MV and 15 MV photons. The profiles were measured for various field sizes starting from 2×2 cm till 30×30 cm. PTW TBA scan software was used for the measurements and the “deconvolution” functionality in the software was used to remove the volume averaging effect due to finite volume of the chamber along lateral and longitudinal directions for all the ionization chambers. The predicted true profile was compared and the change in penumbra before and after deconvolution was studied. Results: After deconvoluting the penumbra decreased by 1 mm for field sizes ranging from 2 × 2 cm till 20 x20 cm. This is observed for along both lateral and longitudinal directions. However for field sizes from 20 × 20 till 30 ×30 cm the difference in penumbra was around 1.2 till 1.8 mm. This was observed for both 6 MV and 15 MV photon beams. The penumbra was always lesser in the deconvoluted profiles for all the ionization chambers involved in the study. The variation in difference in penumbral values were in the order of 0.1 till 0.3 mm between the deconvoluted profile along lateral and longitudinal directions for all the chambers under study. Deconvolution of the profiles along longitudinal direction for Farmer chamber was not good and is not comparable with other deconvoluted profiles. Conclusion: The results of the deconvoluted profiles for 0.125cc and Markus chamber was comparable and the deconvolution functionality can be used to overcome the volume averaging effect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster - 09: A MATLAB-based Program for Automated Quality Assurance of a Prostate Brachytherapy Ultrasound System

Purpose: A robust Quality Assurance (QA) program is essential for prostate brachytherapy ultrasound systems due to the importance of imaging accuracy during treatment and planning. Task Group 128 of the American Association of Physicists in Medicine has recommended a set of QA tests covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, and template/electronic grid alignment. Making manual measurements on the ultrasound system can be slow and inaccurate, so a MATLAB program was developed for automation of the described tests. Methods: Test images were acquired using a BK Medical Flex Focus 400 ultrasound scanner and 8848 transducer with the CIRS Brachytherapy QA Phantom – Model 045A. For each test, the program automatically segments the inputted image(s), makes the appropriate measurements, and indicates if the test passed or failed. The program was tested by analyzing two sets of images, where the measurements from the first set were used as baseline values. Results: The program successfully analyzed the images for each test and determined if any action limits were exceeded. All tests passed – the measurements made by the program were consistent and met the requirements outlined by Task Group 128. Conclusions: The MATLAB program we have developed can be used for automated QA of an ultrasound system for prostate brachytherapy. The GUI provides a user-friendly way to analyze images without the need for any manual measurement, potentially removing intra- and inter-user variability for more consistent results.

60 APPLIED LIFE SCIENCES↗

Poster - 10: QA of Ultrasound Images for Prostate Brachytherapy

Purpose: The current QA protocol of ultrasound systems used in prostate brachytherapy (TG128) addresses geometrical verifications, but the scope of evaluation of image quality is limited. We recognized importance of the latter in routine practice, and designed a protocol for QA of the images. Methods: Images of an ultrasound prostate phantom (CIRS053) were collected with BK Flex Focus 400. The images were saved as bmp after adjusting the gain to 50% for consistent results. Mean pixel values and signal to noise ratio were inspected in the representative sections of the phantom, including the mock prostate and the unechoic medium. Constancy of these numbers over a one year period was looked at. Results: The typical intensity in the mock prostate region in the transverse images ranged between 95 and 118 (out of 256), and the signal to noise was about 10. The intensity in the urethra region was about 170±40, and the unechoic medium was 2±2. The mean and the signal to noise ratio remained almost unchanged after a year, while the signal in the unechoic medium increased to about 7±4. Similar values were obtained in the sagittal images. Conclusions: The image analysis discussed above allows quick evaluation of constancy of the image quality. This may be also useful in troubleshooting image-quality problems during routine exams, which might not be due to deterioration of the US system, but other reasons, e.g. variations in tissue properties or air being trapped between the probe and the anatomy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ENSIGN

ENSIGN is a data analytics software package offering a modern unsupervised machine learning solution for scalable discovery in Big Data. The analytics in ENSIGN are based on an advanced mathematical tool called tensor decomposition and they are optimized to run efficiently on a range of computing platforms (from small multicore Desktop platforms to large Supercomputing clusters and novel high-end memory-driven computing platforms such as HPE Superdome Flex). ENSIGN enables the user to extract deep insights from the entirety of massive-scale (100s of Gigabytes or Terabytes scale) multidimensional data. ENSIGN uncovers latent patterns in data without the user having to specify or describe what the patterns are; the user, in the first place, may not even know such patterns existed and that they have to look for such patterns. The insights gained from ENSIGN could be trailheads that can be used as starting points for deeper forensic investigation.

Baskaran, Muthu↗

ENSIGN

ENSIGN is a data analytics software package offering a modern unsupervised machine learning solution for scalable discovery in Big Data. The analytics in ENSIGN are based on an advanced mathematical tool called tensor decomposition and they are optimized to run efficiently on a range of computing platforms (from small multicore Desktop platforms to large Supercomputing clusters and novel high-end memory-driven computing platforms such as HPE Superdome Flex). ENSIGN enables the user to extract deep insights from the entirety of massive-scale (100s of Gigabytes or Terabytes scale) multidimensional data. ENSIGN uncovers latent patterns in data without the user having to specify or describe what the patterns are; the user, in the first place, may not even know such patterns existed and that they have to look for such patterns. The insights gained from ENSIGN could be trailheads that can be used as starting points for deeper forensic investigation.

Baskaran, Muthu↗

evmc-supply-curves (Electric Vehicle Managed Charging Supply Curves) [SWR-25-69]

Data and a supporting lightweight Python package that describes possible costs for enabling EV managed charging from 2025 to 2050 for three dispatch mechanisms: Time-of-Use (TOU), Real Time Pricing (RTP), and direct load control (DLC) and four flexibility scenarios (Flat and Low, Mid, and High Flex).

Matsuda-Dunn, Reiko [National Renewable Energy Lab↗

Gradient-based surface nuclear magnetic resonance for groundwater investigation

In medical magnetic resonance imaging, spatial localization (imaging) is based upon the application of controlled magnetic field gradients on top of the main magnetic field to spatially modulate the frequency and/or phase of the nuclear magnetic resonance (NMR) signal across the volume of investigation. In this work, we have applied similar physical principles to produce controlled magnetic field gradients during surface NMR-based groundwater investigations. In this approach, a gradient pulse of variable amplitude or duration is applied immediately after the excitation pulse to cause predictable phase encoding of the NMR signal as a function of depth. This approach is also applicable to emerging surface NMR detection methods that use a prepolarization field with fast nonadiabatic turn-off to generate detectable NMR signals from the shallow subsurface. In this case, the gradient pulse is applied after terminating the prepolarization field and provides a heretofore unavailable means of localizing the NMR response as a function of depth. The application of gradients can also be combined with tip-angle-based modulation to yield higher imaging resolution than can be achieved through either gradient- or tip-angle-based imaging alone. We implemented this new gradient-based capability into a surface NMR gradient generation accessory that is compatible with the GMR-Flex instrument and developed surface NMR-specific forward modeling and linear inverse models. We validated the accuracy of this novel gradient-based sNMR technology using computer simulations, experiments using a small pool filled with a discrete layer of bulk water, and field experiments at well-characterized groundwater test sites along Ebey Island, WA, and Larned, KS. The gradient-based sNMR imaging observations were compared with high-resolution direct push NMR results observed at these sites. The results of computer simulations and field experiments indicate improvements in both the detection (signal-to-noise ratio) and spatial resolution of shallow subsurface water content using gradient-based surface NMR, compared with traditional surface NMR imaging methods.

Geochemistry & Geophysics↗

A proposed methodology for estimating transient engine-out temperature and emissions from steady-state maps

Many vehicle systems simulations utilize engine maps constructed from steady-state dynamometer measurements to estimate exhaust temperature and emissions as functions of engine speed and load. Unfortunately, steady-state engine behavior is often significantly different from actual behavior under realistic driving conditions. This is particularly true for vehicles (e.g., electric hybrids) that undergo repeated engine shutdown and restart. We propose a methodology for estimating transient engine exhaust properties based on corrections to steady-state maps. We have implemented our methodology in the Powertrain Systems Analysis Toolkit (PSAT) and use this implementation to demonstrate good agreement with experimental measurements for both a light-duty diesel and a flex-fuel gasoline/ethanol engine. We also recommend specific procedures for setting key parameters required by our methodology and suggest possible directions for further improvements.

33 ADVANCED PROPULSION SYSTEMS↗

Layer-wise Imaging Dataset from Powder Bed Additive Manufacturing Processes for Machine Learning Applications (Peregrine v2022-10)

This release consists of six datasets which together include multi-modal layer-wise powder bed images from two different powder bed printing technologies. These datasets are designed primarily to facilitate the development and testing of new computer vision and machine learning based anomaly and defect detection algorithms. The authors provide both training data with corresponding ground truth pixel masks and evaluation data with corresponding baseline prediction pixel masks made by a trained neural network. The laser powder bed fusion (L-PBF) datasets are sourced from EOS M290 and AddUp FormUp 350 printers and the binder jet (BJ) dataset is sourced from an ExOne M-Flex printer. The materials represented in these datasets include 17-4 PH Stainless Steel, DMREF, Inconel 718, Maraging Steel, and H13 Steel. The sensor imaging modalities represented include visible-light (VL), temporally-integrated (i.e., long duration exposure) near-infrared (TI-NIR), and wide-band infrared (IR).

36 MATERIALS SCIENCE↗

Layer-wise Imaging Dataset from Powder Bed Additive Manufacturing Processes for Machine Learning Applications (Peregrine v2022-10.1)

This release consists of six datasets which together include multi-modal layer-wise powder bed images from two different powder bed printing technologies. These datasets are designed primarily to facilitate the development and testing of new computer vision and machine learning based anomaly and defect detection algorithms. The authors provide both training data with corresponding ground truth pixel masks and evaluation data with corresponding baseline prediction pixel masks made by a trained neural network. The laser powder bed fusion (L-PBF) datasets are sourced from EOS M290 and AddUp FormUp 350 printers and the binder jet (BJ) dataset is sourced from an ExOne M-Flex printer. The materials represented in these datasets include 17-4 PH Stainless Steel, GammaPrint-700, Inconel 718, Maraging Steel, and H13 Steel. The sensor imaging modalities represented include visible-light (VL), temporally-integrated (i.e., long duration exposure) near-infrared (TI-NIR), and wide-band infrared (IR). To download the dataset: (1) Create a Globus account. (2) Create a Globus Endpoint on your computer. (3) Transfer the dataset from the OLCF DOI-DOWNLOADS Collection to your Collection. Common troubleshooting steps: (a) Confirm that the transfer is going from OLCF DOI-DOWNLOADS to your Collection. (b) Create an exception for Globus in your antivirus software so that it can create an Endpoint. (c) Manually create a Globus access directory (where the data will be downloaded) by going to the Preferences > Access tab.

36 MATERIALS SCIENCE↗

Wavelength contention in an entanglement network

We investigate spectral resource contention between two entangled photon sources sharing the same wavelength, demonstrating measurable fidelity impact and providing insights that enable more efficient spectral management in flex-grid quantum networks.

Alshowkan, Muneer [ORNL] (ORCID:0000000264293450)↗