Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLEXIBILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Field tests of a highly flexible downwind ultralight rotor to mimic a 13-MW turbine rotor

Offshore extreme-scale turbines of 20–25 MW in size may offer reduced energy costs. The technical barriers at these extreme scales include escalating blade masses with increased flexibility as well as high gravity loads and tower-strike issues. These barriers may be addressed with a load-aligning downwind turbine. To investigate this type of design, a field test campaign was conducted with an aeroelastically scaled rotor, termed the Segmented Ultralight Morphing Rotor Demonstrator (SUMR-D). The tests were conducted on the Controls Advanced Research Turbine at the National Renewable Energy Laboratory. The paper gives an overview of the experimental diagnostics, blade design, and results of the field campaign, as well as makes conclusions and recommendations regarding extreme-scale highly flexible downwind rotors.

17 WIND ENERGY↗

Tri-Level Scheduling Model Considering Residential Demand Flexibility of Aggregated HVACs and EVs Under Distribution LMP

Residential loads, especially heating, ventilation and air conditioners (HVACs) and electric vehicles (EVs), have great potentials to provide demand flexibility which is an attribute of grid-interactive efficient buildings (GEB). Under this new paradigm, first, EV and HVAC aggregator models are developed in this paper to represent the fleet of GEBs, in which the aggregated parameters are obtained based on a new approach of data generation and least squares parameter estimation (DG-LSPE), which can deal with heterogeneous HVACs. Then, a tri-level bidding and dispatching framework is established based on competitive distribution operation with distribution locational marginal price (DLMP). Furthermore, the first two levels form a bilevel model to optimize the aggregators’ payment and to represent the interdependency between load aggregators and the distribution system operator (DSO) using DLMP, and the third level is to dispatch the optimal load aggregation to all residents by the proposed priority list-based demand dispatching algorithm. Finally, case studies on a modified IEEE 33-Bus system illustrate three main technical reasons of payment reduction due to demand flexibility: load shift, DLMP step changes, and power losses. They can be used as general guidelines for better decision-making for future planning and operation of demand response programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Agent Hierarchical Deep Reinforcement Learning for HVAC Control With Flexible DERs

As electricity consumption in commercial and residential buildings continues to rise, reducing energy costs presents an increasing challenge. Heating, ventilating, and air-conditioning (HVAC) systems, which typically account for 40%-50% of a building's energy use, are prime targets for energy savings. Intelligent control of HVAC temperature through the exploitation of HVAC load flexibility brings significant potential to reduce energy consumption and electricity expenses. The nonlinear models of HVAC systems challenge traditional control methods, while the uncertainty introduced by HVAC load flexibility complicates distributed energy resource (DER) management using conventional optimal dispatch techniques. In response to these challenges, we propose a hierarchical multi-agent deep reinforcement learning (DRL) approach. The lower-level agents focus on balancing comfort and energy conservation, while the upper-level DRL agents optimize the use of DERs to reduce peak demand based on the control outcomes of the HVAC by the lower-level agents. Here, in the upper-level agents, we incorporate a multi-agent structure based on ensemble learning, which acts based on historical and current data without relying on precise load forecasting to address the delayed rewarding issue in DRL. This allows for the effective reduction of energy costs. The proposed method is tested using a real-world microgrid comprising 413 buildings in Southern California, and the results demonstrate that our approach can significantly reduce overall electricity bills while ensuring the comfort of consumers and residents.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Substructure Flexibility and Member-Level Load Capabilities for Floating Offshore Wind Turbines in OpenFAST

OpenFAST is an open-source, physics-based engineering tool applicable to the load analysis of land-based and offshore wind turbines, including floating offshore wind turbines. The substructure for a floating wind turbine has historically been modeled in OpenFAST as a rigid body with hydrodynamic loads lumped at a point, which enabled the tool to predict the global response of the floating substructure but not the structural loads within its individual members. This limitation is an impediment to designing floating substructures - especially newer designs that are more streamlined, flexible, and cost-effective. This paper presents the development plan of new capabilities in OpenFAST to model floating substructure flexibility and member-level loads, including the functional requirements and modeling approaches needed to understand and apply them correctly.

17 WIND ENERGY↗

Leveraging Flexible Smart Manufacturing to Accelerate Industrial Supply Chain Recovery

Any major crisis such as the latest coronavirus disease pandemic will have a monumental effect on the worldwide economy and on the international supply chain. Much of the global supply chain relies on China, Germany, and the United States for manufacturing and distribution; this fragile system is subject to failure. Climactic changes in demand and rapid shortages in necessities are the results of the pandemic’s disruption. The recovery forecast for the ongoing pandemic is uncertain and, therefore, any recovery effort will need to be adaptable to build the supply chain resiliency. A wide adoption of flexible smart automated technologies in the manufacturing sector are helping to build robust supply chains and assisting in recovery. Here, a brief discussion of these smart manufacturing technologies is presented, along with a list of potential supply chain issues and corresponding solutions. Such smart manufacturing technologies possess the potential to empower and revolutionize the traditional manufacturing environment by enhancing its resiliency and flexibility. These smart technologies will play a crucial role in accelerating the worldwide supply chain recovery in and after a pandemic.

99 GENERAL AND MISCELLANEOUS↗

Implementation of Substructure Flexibility and Member-Level Load Capabilities for Floating Offshore Wind Turbines in OpenFAST

OpenFAST is an open-source, physics-based engineering tool applicable to the load analysis of land-based and offshore wind turbines, including floating offshore wind turbines. The substructure for a floating wind turbine has historically been modeled in OpenFAST as a rigid body with hydrodynamic loads lumped at a point, which enabled the tool to predict the global response of the floating substructure but not the structural loads within its individual members. This limitation is an impediment to designing floating substructures - especially newer designs that are more streamlined, flexible, and cost-effective. This paper presents the development of new functionality in OpenFAST to model floating substructure flexibility and member-level loads, as well as the concepts and mathematical background needed to understand and apply it correctly.

17 WIND ENERGY↗

Efficiency and Demand Flexibility in Large Office Buildings: The Potential for Cost Savings and CO 2 Reductions from Lighting and Cooling Measures

This report presents the estimated impact of lighting and cooling efficiency and demand flexibility measures in large office buildings in each state in the contiguous United States. It provides modeled results for three different metrics: bill savings, regional grid operational costs savings, and carbon dioxide (CO 2 ) emissions reductions. Lighting efficiency and demand flexibility are estimated to reduce load by up to 80 MWh/yr in a single large office building. These load reductions result in customer bill savings of up to $8,800/yr per building, with the highest savings in southern and midwestern states. Grid operating cost savings are estimated at up to $3,240/yr/building, with greatest benefit in southern and northeastern states. CO 2 emissions reduction potential is highest in the Dakotas, Nebraska, across the Midwest, in West Virginia, and in Mississippi (<48,200 kg/yr/building). Comparatively, cooling measures are found to have less load reduction potential (<28.5 MWh/yr/building), with the greatest potential in southern states including Texas, which ranks top of the list across several of the metrics studied. In numerous states, shifting cooling load to off-peak hours is found to increase costs and CO 2 emissions because precooling results in increased load during high-cost or high-CO 2 emissions periods. In general, focusing on cooling efficiency and load shedding has the potential for more savings. In all cases, the specific rate structure is a significant determinant in actual bill savings, which are up to $4,000/yr/building. To realize the full potential for bill savings through an energy measure, building operators must identify how the measure will change the building load pattern and the interaction of this load change with the applicable rate tariff. To realize CO 2 emissions reductions, industry and state coordination is needed to verify which fuel source is on the margin and then to create incentives for end users to reduce load during high-CO 2 emissions hours. Regular updates to data sets and analyses are critical. Regulators and policymakers are well positioned to facilitate the necessary coordination between the electric industry and building energy managers to develop appropriate price signals and incentives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Multidisciplinary Approach to Integrated Energy Systems: Advanced Nuclear Plants with Thermal Storage for Dynamic and Flexible Operation in Diverse Markets

Energy supply, distribution, and demand are continuously evolving in accordance with the integration of new power generation sources. In the United States, there is a progressive shift toward incorporating fluctuating energy sources such as wind and solar into the energy mix, alongside the distributed generation. Simultaneously, we are seeing a revolution in consumer technologies such as electric vehicles, energy devices for both residential and commercial use, and industrial processes—all contributing to a fundamental change in energy consumption dynamics. These scenarios have led to huge demand for enhanced flexibility from nuclear power plants (NPPs), requiring them to operate with unprecedented adaptability. Furthermore, advanced NPPs (A-NPPs) could potentially apply to scenarios in which power generation flexibility is prioritized over its current and conventional baseload generation capacity for traditional demand patterns. The present work covers several configurations for coupling nuclear energy production with thermal energy storage (TES). Previous work evaluated systems entailing a simple nuclear-TES configuration that used steam as a heat source for the TES of three different advanced reactors (ARs), but its heat diversion ratio (HDR) for charging was limited. The present work proposes a new configuration that features full decoupling of the nuclear reactor and the power cycle, using reactor coolant (i.e., gas) as a heat source for the TES and offering a theoretically unlimited HDR. This configuration is, however, more complex, as both high- and low-temperature TES (HT-TES and LT-TES) systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Conventional TES systems take advantage of nominal efficiency when discharging, whereas the reheat cycle in the fully decoupled TES system affords a significant efficiency increase over conventional cases. Material selection, component/equipment sizing, and costing analyses were performed, followed by economic dispatch and size optimization. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation (e.g., drops in cycle efficiency), and these models enable exploration of potential mitigation strategies for addressing such drops. The models also highlight the need to design fail-safes that ensure continuous operational stability and minimize the impact of power ramping on the reactor parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hardware-in-the-loop Laboratory Performance Verification of Flexible Building Equipment in a Typical Commercial Building

This project aims to develop high-resolution equipment performance and occupant data that quantifies demand flexibility in typical commercial buildings. The dataset documented in this report includes comprehensive time-series measurements from hardware-in-the-loop (HIL) experiments conducted across multiple testbeds designed to simulate realistic operational environments for HVAC systems. Specifically, it captures minute-by-minute high-resolution data on the performance of various typical HVAC systems, including a variable-air-volume (VAV) air handling unit (AHU) system with chillers and an ice tank in the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), a two-stage air-source heat pump (ASHP) at the NIST, and a water-source heat pump (WSHP) at Texas A&M University (TAMU). The data were generated under a range of controlled conditions reflecting different grid scenarios and climatic influences, as well as various control strategies, building types, occupancy patterns, and occupant behaviors. This dataset provides DE-EE0009153 Final Report 5 detailed insights into the demand flexibility of these systems, including their response to grid signals, occupant behaviors, energy consumption patterns, and operational efficiency under different conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Solutions to Demand Growth in Virginia: Options for Demand Flexibility [Slides]

This slide deck report presents a literature review on virtual power plants (VPPs) and a demand flexibility analysis for the state of Virginia as part of DOE's State Energy Program (SEP) technical assistance work. The literature review describes key concepts, examples, participation models, and other issues for VPPs, and the analysis section presents a state-specific demand flexibility analysis estimating the technical potential for demand response from various sectors and end-uses. These materials are meant to inform and support VA's ability to shepherd ongoing dialogue and meet energy needs in the midst of strong load growth.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flexible Natural Gas/Hydrogen CHP System

This project included design, development, and demonstration of a cost-effective and scalable, unique-to-the-industry 2.0 MWe fuel-flexible Caterpillar G3516 CHP genset that can run on 100% hydrogen, 100% natural gas, and up to 25% blends of hydrogen in natural gas (volume basis). This was accomplished based on over two years of extensive R&D work done on a single-cylinder engine for developing innovative hydrogen fueling, combustion, air, and electronic control systems design and strategies. Findings from the single-cylinder engine work were scaled up and applied for modifications of and lab testing and development of a 2.0 MWe 16-cylinder G3516 fuel-flexible engine-genset and electronic controls systems. During this testing and development in the engine lab, the genset was run on 100% hydrogen, 100% natural gas, and up to 25% blends of hydrogen in natural gas (volume basis) and its steady-state and transient performance and emission were documented.

03 NATURAL GAS↗

A Flexible Quasi-Static Mooring Design Optimization Method for Floating Structures

This paper presents a flexible and efficient design method for optimizing the mooring systems of floating structures. Mooring system optimization is challenging because of the strong nonlinearity of mooring system behavior and the many technical constraints that must be satisfied. Furthermore, different mooring configurations can have very different design spaces. While some successful examples of mooring design optimization exist in the literature, developing an optimization approach that can work across various mooring design problems is a larger challenge. We present such a method based on a flexible parameterization that allows a wide variety of mooring designs to be described by a list of variables, a quasi-static mooring model that provides efficient evaluation of a mooring design without directly considering mooring system dynamics, and an optimization framework that generates, evaluates, and adjusts the mooring design while considering user-specified constraints such as offset limits, strength safety factors, and seabed contact limits. We demonstrate the design optimization framework on four mooring design problems, each for a different type of mooring system. We compare the use of different design modes to simplify the optimization problem, showing that they can reduce the computation time by up to 75%. We also compare different optimization algorithms and find that the resulting computational speed can vary by up to 51 times. We perform a sensitivity study on one design and find that the local sensitivity of anchoring radius to water depth has a positive correlation of 0.29, but the global sensitivity shows large nonlinearities. Lastly, we perform a coupled dynamic analysis on one of the optimized designs and find that the predicted mean platform motions and mooring line tensions are within 1% of dynamic results and the extreme motions and tensions are within 14%. Lastly, we show that a DEA-Chain-Polyester mooring configuration is cost-optimal for the given design problem of the demonstrations, which aligns with general industry practice.

16 TIDAL AND WAVE POWER↗

Understanding the Charging Flexibility of Shared Automated Electric Vehicle Fleets

The combined anticipated trends of vehicle sharing (ride-hailing), automated control, and powertrain electrification are poised to disrupt the current paradigm of predominately owner-driven gasoline vehicles with low levels of utilization. Shared, automated, electric vehicle (SAEV) fleets offer the potential for lower cost and emissions and have garnered significant interest among the research community. While promising, unmanaged operation of these fleets may lead to unintended negative consequences. One potentially unintended consequence is a high quantity of SAEVs charging during peak demand hours on the electric grid, potentially increasing the required generation capacity. This research explores the flexibility associated with charging loads demanded by SAEV fleets in response to servicing personal mobility travel demands. Travel demand is synthesized in four major United States metropolitan areas: Detroit, MI; Austin, TX; Washington, DC; and Miami, FL. In each of these four cities, SAEV simulations are performed using local projected electricity prices from the Regional Energy Deployment System (ReEDS) for a handful of supply side scenarios. A coordinated charging model is introduced that seeks to reduce fleet charging costs in response to time-varying electricity prices and increasing shares of personal trip demand served (between 1% and 25% of all metro trips served by the SAEV fleet). Simulation results are presented across various scenarios assuming fleetwide coordination to minimize charging energy costs while constrained by offering adequate mobility service to fleet customers. The results indicate that the SAEV charging load is highly flexible; energy costs were shown to reduce between 13% and 46% across a wide range of simulated scenarios. In addition, these savings were realized without detrimentally impacting the fleet’s ability to service trips.

autonomous vehicle↗

Options for Resilient and Flexible Power Systems in Select South American Economies

This document is the executive summary for the technical report titled 'Options for Resilient and Flexible Power Systems in Select South American Economies' that summarizes opportunities for Argentina, Brazil, Chile and Colombia to adapt to the new forces buffeting electricity sectors around the globe to ensure reliable, affordable, sustainable and resilient power systems. Special attention is placed on the potential role for natural gas to help ensure flexible and resilient power.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enabling Grid-Aware Market Participation of Aggregate Flexible Resources

Increasing integration of distributed energy resources (DERs) within distribution feeders provides unprecedented flexibility at the distribution-transmission interconnection. With the new FERC 2222 order, DER aggregations are allowed to participate in energy market. To enable market participation, these virtual power plants need to provide their generation cost curves. This paper proposes efficient optimization formulations and solution approaches for the characterization of hourly as well as multi-time-step generation cost curves for a distribution system with high penetration of DERs. Network and DER constraints are taken into account when deriving these cost curves, and they enable active distribution systems to bid into the electricity market. The problems of deriving linear and quadratic cost curves are formulated as robust optimization problems and tractable reformulation/solution algorithm are developed to facilitate efficient calculations. The proposed formulations and solution algorithm are validated on a realistic test feeder with high penetration of flexible resources.

aggregated distributed energy resources↗

Flexible Grid Interconnections

Key Considerations: - Long-term coordination and collaboration with utilities and ISOs may provide mutual benefits and support flexible interconnectivity. - Onsite storage and energy production can reduce load fluctuations and support grid resilience in the future. - Geography and resource availability can impact energy demand and grid flexibility.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Freestanding BaTiO 3 ‐Au Vertically Aligned Nanocomposite toward Flexible Multi‐Sensing Platform

Abstract Flexible and wearable sensors show enormous potential for personalized healthcare devices by real‐time monitoring of an individual's health. Typically, a single functional material is selected for one sensor to sense a particular physical signal while multiple materials will be selected for multi‐mode sensing. Vertically aligned nanocomposites (VANs) have recently demonstrated various material combinations and novel coupled multifunctionalities that are hard to achieve in any single‐phase material alone, including multiphase multiferroics, magneto‐optic coupling, and strong magnetic and optical anisotropy. Integrating these novel VANs into wearable sensors shows enormous potential in multi‐mode sensing owing to their multifunctional nature. In this work, the transfer of VANs onto polydimethylsiloxane as a novel flexible chemical and pressure sensor is demonstrated. For this demonstration, the classical BaTiO 3 ‐Au VAN with combined plasmonic and piezoelectric properties is used to demonstrate a multi‐sensing mechanism. A thin water‐soluble buffer of Sr 3 Al 2 O 6 serves as a buffer layer for the epitaxial growth and transfer process. The electrical output based on the piezoelectric responses and identifying 4‐mercaptobenzoic acid by surface‐enhanced Raman spectroscopy reveal great potential for free‐standing VANs in a wearable multifunctional sensing platform.

Tsai, Benson Kunhung [School of Materials Engineer↗