Search NASA⌕ Search

SEARCH · Search NASA

Results for “FS Laser”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Low Repetition-Rate, High-Resolution Femtosecond Transmission Electron Microscopy

Spatial and energy resolutions of state-of-the-art transmission electron microscopes (TEMs) have surpassed 50 pm and 5 meV. However, with respect to the time domain, even the fastest detectors combined with the brightest sources may only be able to reach the microsecond timescale. Thus, conventional methods are incapable of resolving myriad fundamental ultrafast (i.e., attosecond to picosecond) atomic-scale dynamics. The successful demonstration of femtosecond (fs) laser-based (LB) ultrafast transmission electron microscopy (UEM) nearly 20 years ago provided a means to span this nearly 10-order-of-magnitude temporal gap. While nanometer-picosecond UEM studies of dynamics are now well established, ultrafast Å-scale imaging has gone largely unrealized. Further, while instrument development has rightly been an emphasis, and while new modalities and uses of pulsed-beam TEM continue to emerge, the overall chemical and materials application space has been only modestly explored to date. In this Perspectives article, we argue that these apparent shortfalls can be attributed to a simple lack of data and detail. We speculate that present work and continued growth of the field will ultimately lead to the realization that Å-scale fs dynamics can indeed be imaged with minimally modified UEM instrumentation and with repetition rates (f rep ) below - and perhaps even well below - 1 MHz. We further argue that use of low f rep , whether for LB UEM or for chopped/bunched beams, significantly expands the accessible application space. Furthermore, this calls for systematically establishing modality-specific limits so that especially promising technologies can be pursued, thus ultimately facilitating broader adoption as individual instrument capabilities expand.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Precision and Spatial Resolution Chemical Interrogation of Planetary Materials Using fs-LA/LIBS in Tandem With Multi-Collector ICP-MS

Combining femtosecond laser ablation (fs-LA) with laser-induced breakdown spectroscopy (LIBS), together with multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS), can provide remarkable insights into the composition, structure, and therefore geologic history of planetary materials and their terrestrial analogs. Using the Applied Spectra iX-fs-Tandem LA-LIBS Instrument and the Nu SP1700 MC-ICP-MS housed within the Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center, we present preliminary tandem fs-LA-(MC)-ICP-MS/LIBS measurements of planetary analog materials. The synergistic integration of fs-LA-LIBS offers high spatial resolution elemental mapping, enabling the identification of microscale variations within samples. Simultaneously, the MC-ICP-MS can deliver precise isotopic analyses, and integrating the two datasets yields a wealth of geochemical information for a given sample. LA-based chemical mapping experiment designs are contingent on the information sought (i.e., quantitative, or semi-quantitative) and the preferred or available volume of material removed for the analysis. For example, occasionally, there are significant limitations in the depth of ablation due to the sample value, the amount of material available, or simply the need to coordinate with other in-situ techniques. In these limited sample scenarios, the “depth-controlled” chemical maps allow for precise post-mapping ion-polishing of the sample, while the isotopic and elemental maps can be used for targeting future analyses (e.g., conventional LA analyses, SIMS analyses, and micro milling for solution ICP-MS/TIMS). The emerging methodology will establish a powerful tool for investigation of astromaterials and materials returned by future planetary sample science missions.

Jacob B Setera↗

Ultrafast laser produced zinc plasma: Stark broadening of emission lines in nitrogen ambient

The effect of ambient pressure on Stark broadening of emission lines from neutrals and ions in an ultrafast laser (100 fs, 800 nm) produced zinc plasma is investigated. Measured spectra reveal that the full width at half maximum (δλ) of neutral lines remains unchanged in the pressure range of 10{sup −6} to 10{sup −1 }Torr, shows an even fluctuation in the pressure range of 0.1 to 100 Torr, and then increases with pressure. On the other hand, δλ of ion lines is nearly a constant from 10{sup −6} to 10{sup −3 }Torr, and then increases consistently with ambient pressure. A line narrowing of neutral emissions observed in the region of 1 to 100 Torr can be attributed to larger plasma temperatures, whereas the consistent increase in δλ with pressure seen for ion emission results from the prevalence of additional broadening mechanisms related to Coulomb interactions, ion-ion interaction, and Debye shielding. An accurate knowledge of emission line width is crucial for unambiguously calculating number density values for any given ambient pressure. Moreover, it can be relevant for the design of narrow line width, bright plasma sources for various applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

6 MeV novel hybrid (standing wave - traveling wave) photo-cathode electron gun for a THz superradiant FEL

A novel 6 MeV hybrid photo-injector has been designed and constructed, based on a smaller-scale prototype previously built in UCLA’s Particle Beam Physics Laboratory. It has been commissioned at Ariel University in Israel as an on-going collaboration between the two universities. This unique, new generation design provides a radically simpler approach to RF feeding of a gun/buncher system, leading to a much shorter beam via velocity bunching owed to an attached traveling wave section of the photo-injector. This design offers better performance in beam parameters, providing a high quality electron beam, with energy of 6 MeV. The hybrid photo-injector was designed to provide emittance of approximately 3 μm, and pulse duration of 150 fs at up to 1 nC per pulse. The hybrid gun is driven by a SLAC XK5 klystron as the high power RF source, and third harmonic of a ~35 fs IR Laser amplifier (266 nm) to extract electrons from the photo-cathode. The unique electron gun will produce a bunched electron pulse to drive a THz FEL, which will operate at the super-radiant regime, and therefore requires ambitious beam properties. This paper describes the gun and presents experimental results from the gun and its sub-systems, including energy and charge measurements, compared with the design simulations.

150fs↗

A Quantitative Method for In Situ Pump-Beam Metrology in 4D Ultrafast Electron Microscopy

In this work, we report a method for measuring spot size and focusing conditions of the femtosecond (fs) excitation laser in situ at the specimen location in 4D ultrafast electron microscopy (UEM). The method makes use of threshold laser ablation behaviors of thin amorphous carbon membranes. For Gaussian beam profiles and for ablation threshold fluence values, we analytically derive expressions describing the relationship between ablated hole size and the actual laser spot size. Using these expressions, we developed experimental procedures for characterizing the shape and spot size of the pump beam at the specimen. We demonstrate the viability of the approach for incident excitation wavelengths of 343 nm and 515 nm, thus illustrating the applicability of the method to a range of optical wavelengths without modification. Further, we show that by measuring ablated hole size as a function of focusing condition, a full metrological characterization of the Gaussian beam propagation properties can be performed. Finally, we find good agreement for spot sizes determined with this method and with those determined by extrapolation from measurements taken outside the microscope column. Overall, this method is a simple, cost-effective means for accurate and precise determination of key pump-beam parameters in situ at the specimen location in UEM experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IR mass-resolved spectroscopy of complexes without chromophore: Cyclohexanol·(H{sub 2}O){sub n}, n = 1–3 and cyclohexanol dimer

Mass-resolved IR spectra of cyclohexanol-water clusters and cyclohexanol dimer in supersonic expansions are presented for the first time. A combination of ns and fs IR lasers made possible recording such spectra without inclusion of a chromophore or a messenger atom. Furthermore, employment of the recently developed IR{sup 3} technique [I. León, R. Montero, F. Castaño, A. Longarte, and J. A. Fernández, J. Phys. Chem. A 116, 6798 (2012)] allowed us to discriminate between the contribution of different species to the IR spectrum. Comparison of the experimental spectra with the predictions at the M06-2X/6-311++G(d,p) calculation level confirmed the assignment of the spectrum of cyclohexanol·(H{sub 2}O){sub 1} to a structure in which water is accepting a proton from cyclohexanol's OH group, and those of cyclohexanol·(H{sub 2}O){sub 2,3} to structures with cyclic hydrogen bond networks. A comparative analysis of the results obtained with those reported on other aromatic alcohols is also offered.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-dimensional spatiotemporal focusing of femtosecond pulses and its applications in microscopy

We demonstrate and theoretically analyze the two-dimensional spatiotemporal focusing of femtosecond pulses by utilizing a two-dimensional spectral disperser. Compared with spatiotemporal focusing with a diffraction grating, it can achieve widefield illumination with better sectioning ability for a multiphoton excitation process. By utilizing paraxial approximation, our analytical method improves the axial confinement ability and identifies that the free spectra range (FSR) of the two-dimensional spectral disperser affects the out-of-focus multiphoton excitation intensity due to the temporal self-imaging effect. Based on our numerical simulation, a FSR of 50 GHz is necessary to reduce the out-of-focus two-photon excitation by 2 orders of magnitude compared with that in a grating-based spatiotemporal focusing scheme for a 90-fs excitation laser pulse. We build a two-dimensional spatiotemporal focusing microscope using a virtually imaged phased array and achieve an axial resolution of 1.3 μm, which outperforms the resolution of conventional spatiotemporal focusing using a grating by a factor of 1.7, and demonstrate better image contrast inside a tissue-like phantom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV

Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ~300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. In conclusion, the high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.

47 OTHER INSTRUMENTATION↗

Observation of shells in Coulomb explosions of rare-gas clusters

The explosions of noble gas clusters from argon and xenon irradiated by intense 35-fs infrared laser pulses have been studied. The kinetic energy spectra of ions produced in small clusters (<700 atoms) show a two-mode shell structure that is attributed to originating from a radial charge distribution. With a simple classical particle simulation of Coulomb explosions, the energy structure was reproduced using information on the arrangement of charge in the cluster. It was found that, during the explosion, the inner atoms of the clusters were less ionized than the outer atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Boosting SNR of cascaded FBGs in a sapphire fiber through a rapid heat treatment

This Letter reports the performance of femtosecond (fs) laser-written distributed fiber Bragg gratings (FBGs) under high-temperature conditions up to 1600°C and explores the impact of rapid heat treatment on signal-to-noise ratio (SNR) enhancement. FBGs are essential for reliable optical sensing in extreme temperature environments. Comprehensive tests demonstrate the remarkable performance and resilience of FBGs at temperatures up to 1600°C, confirming their suitability for deployment in such conditions. Here, the study also reveals significant fringe visibility improvements of up to ∼10 dB on a 1-m-long sapphire optical fiber through rapid heat treatment, representing a first-time achievement to the best of our knowledge. These enhancements are vital for improving the SNR and overall performance of optical fiber systems in extreme temperatures. Furthermore, the research attains long-term stability for the cascaded FBGs over a 24-hr period at 1600°C. This research expands our understanding of the FBG behavior in high-temperature environments and opens avenues for developing robust optical fiber systems for energy, aerospace, oil and gas, and high-temperature distributed sensing applications.

47 OTHER INSTRUMENTATION↗

<10 fs Infrared High Energy Fiber Laser

The Department of Energy seeks to advance ultrafast science dealing with physical phenomena that occur in the range of one-trillionth of a second (one picosecond) to less than onequadrillionth of a second (one femtosecond). The physical phenomena motivating this subtopic include the direct observation of the formation and breaking of chemical bonds, and structural rearrangements in both isolated molecules and the condensed phase. These phenomena are typically probed using extremely short pulses of laser light. Ultrafast technology also would be applicable in other fields, including atomic and molecular physics, chemistry and chemical biology, coherent control of chemical reactions, materials sciences, magnetic and electric field phenomena, optics, and laser engineering.

42 ENGINEERING↗

Space-Time Characterization of Laser Plasma Interactions in the Warm Dense Matter Regime

Laser plasma interaction experiments have been performed using a fs Titanium Sapphire laser. Plasmas have been generated from planar PMMA targets using single laser pulses with 3.3 mJ pulse energy, 50 fs pulse duration at 800 nm wavelength. The electron density distributions of the plasmas in different delay times have been characterized by means of Nomarski Interferometry. Experimental data were compared with hydrodynamic simulation. First results to characterize the plasma density and temperature as a function of space and time are obtained. This work aims to generate plasmas in the warm dense matter (WDM) regime at near solid-density in an ultra-fast laser target interaction process. Plasmas under these conditions can serve as targets to develop x-ray Thomson scattering as a plasma diagnostic tool, e.g., using the VUV free-electron laser (FLASH) at DESY Hamburg.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hard x-ray generation by low energy, tightly focused laser pulses

The interaction of {lambda}{sup 2} laser pulses with plasma is studied to scale the high-field physics from high power laser systems to low-energy, high-repetition-rate lasers. For this purpose, 20 mJ, 40 fs Ti:sapphire laser pulses were focused in a spot of 2.2x2.3 {mu}m{sup 2} with a maximum intensity of I{approx}10{sup 19} W/cm{sup 2}. Efficient generations of energetic electrons ({approx}1 MeV) and hard x-rays with energies of over 100 keV were obtained by irradiating the low-energy, tightly focused laser pulses on a massive Cu target.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrahigh Intensity Laser-Matter Interaction Studies at RRCAT, Indore

The Laser Plasma Division of the Raja Ramanna Centre for Advanced Technology (RRCAT), Indore has been engaged in research and development activities on laser plasma interaction using a 10 TW, 45 fs, Ti:sapphire laser and a variety of in-house developed diagnostic systems for ultrashort laser pulses, plasma, and x-ray radiation. Our recent studies include high order harmonic generation and optimization, laser driven electron acceleration, enhancement of x-ray yield in the water-window spectral region, ultrashort high brightness K-{alpha} x-ray generation, and MeV energy bremsstrahlung radiation. This paper briefly describes these studies and the important results obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation of optical pulses of duration down to 8 fs upon filamentation of collimated femtosecond laser radiation in argon

A new scheme providing self-compression of femtosecond laser radiation upon filamentation of a collimated beam in argon at a pressure of {approx}0.8 atm is experimentally realised. Pulses with the initial duration of 55 fs were compressed down to 8 fs, the peak power of the compressed pulse exceeding 20 GW. (letters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact electron source for the dielectric laser accelerator

In this work, we design and demonstrate a compact electron source that combines an integrated silicon nanotip photoemitter with a compact silicon-based electrostatic lens. The lens simultaneously accelerates electrons to 30 keV and focuses the resulting beam to a 0.4 μm (RMS) beam diameter with 62 pm-rad normalized emittance at a distance of 20 mm from the cathode. The compact nature of this lens provides a compelling source for dielectric laser accelerator (DLA) beamlines, ultrafast electron diffraction, or ultrafast electron microscopy. Driven by a 220 fs, 1960 nm pulsed laser beam, electron currents up to 28 electrons/pulse at 100 kHz are demonstrated. The electron bunch length is 540 ± 50 fs for photocurrents of <1 electron/pulse, increasing to 700 ± 80 fs for 28 electrons/pulse, as measured by cross correlation with a 220 fs pulsed laser beam. The maximum 5D peak brightness is measured to be 6.8 × 10 13 A/(m 2 rad 2 ) at 28 electrons/pulse. These results represent a significant step toward developing practical benchtop-sized linear accelerators based on DLA technology or compact ultrafast electron microscopy and diffraction applications.

47 OTHER INSTRUMENTATION↗