Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fast Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Accident Tolerant Fuel Test 2B (ATF-2B) Irradiation Test Report

A fully prototypic testing platform for testing new accident tolerant fuel (ATF) designs for light water reactors has been established in the center flux trap of Idaho National Laboratory’s advanced test reactor (ATR). The irradiation experiment named ATF-2 has completed 7 cycles of prototypic steady state irradiation irradiating 41 test pins to burnups as high as 30 MWd/kgU. Irradiation conditions have been maintained via the loop 2a pressurized water coolant loop and have been monitored through in-situ instrumentation during each cycle. Power and fast neutron flux histories of each of the 41 test pins has been calculated using a combined MCNP, and ORIGIN methodology to provide accurate and reliable power histories on a per pin basis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mars: The Terra Arabia Low Epithermal Neutron Flux Anomaly

The High Energy Neutron Spectrometer (HEND) and Neutron Specrometer, part of the Mars Odyssey Gamma Ray Spectrometer suite of instruments, measured anomalously low epithermal neutron flux in two low-latitude areas, Terra Arabia and SW of Olympus Mons (SWOM). The low epithermal neutron flux, an indirect measure of Hydrogen abundance, is indicative of relatively high water content (in this case up to 8 mass percent) in the upper 1-2 m of the surface layer. The epithermal flux within the 60 degree latitude zone does not correlate with bedrock geology or topography but partially correlates (for Arabia) with thermal inertia. According to theoretical estimates for the current geologic epoch, ground ice should not be stable at this depth at these low latitudes so it was concluded that the anomalies are due to the presence of chemically bound water (e.g. clays, hydroxides or hydrosalts). Fast neutron flux, which is indicative of the presence of water at 20-30 cm depth, does not correlate in this latitude zone with the epithermal neutron flux. As a further step of the analysis a geotraverse including study of 152 high resolution MOC images within the Arabia anomaly was done by to find out if the area inside the anomaly differs from the neighboring areas by the presence of fluvial channels and layered deposits (possible links to chemically bound water) or in thickness and apparent texture of the surface layer. No differences were found.

Basilevsky, A. T.↗

Experimental setup for the determination of the correction factors of the neutron doseratemeters in fast neutron fields

The use of the U-120 Cyclotron of the IFIN-HH allowed to perform a testing bench with fast neutrons in order to determine the correction factors of the doseratemeters dedicated to neutron measurement. This paper deals with researchers performed in order to develop the irradiation facility testing the fast neutrons flux generated at the Cyclotron. This facility is presented, together with the results obtain in determining the correction factor for a doseratemeter dedicated to the neutron dose equivalent rate measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Thermal Hydraulic Effect of Fuel Plate Surface Roughness

This study presents surface roughness measurements characteristic of the pre-film layer applied to a typical Advanced Test Reactor (ATR) fuel plate. This data is used to estimate the friction factor for thermal hydraulic flow calculations of a Gas Test Loop (GTL) system proposed for incorporation into ATR to provide a fast neutron flux environment for the testing of nuclear fuels and materials. To attain the required neutron flux, the design includes booster fuel plates clad with the same aluminum alloy as the ATR driver fuel and cooled with water supplied by the ATR primary coolant pumps. The objectives of this study are to: (1) determine the surface roughness of the protective boehmite layer applied to the ATR driver fuel prior to reactor operations in order to specify the machining tolerances for the surface finish on simulated booster fuel plates in a GTL hydraulic flow test model, and (2) assess the consequent thermal hydraulic impact due to surface roughness on the coolability of the booster fuel with a similar pre-film layer applied. While the maximum roughness of this coating is specified to be 1.6 µm (63 microinches), no precise data on the actual roughness were available. A representative sample coupon autoclaved with the ATR driver fuel to produce the pre-film coating was analyzed using optical profilometry. Measurements yielded a mean surface roughness of 0.53 µm (21 microinches). Results from a sensitivity study show that a ±15% deviation from the mean measured surface finish would have a minimal effect on coolant temperature, coolant flow rate, and fuel temperature. However, frictional losses from roughnesses greater than 1.5 µm (~60 microinches) produce a marked decrease in flow rate, causing fuel and coolant temperatures to rise sharply.

36 MATERIALS SCIENCE↗

Effect of the electric field pattern on the generation of fast electrons in front of lower hybrid launchers

The effect of the detailed waveguide spectrum on the electron acceleration has been studied for the 3.7 GHz LHCD launchers in Tore Supra, i.e. the ITER-like passive-active multijunction (PAM) launcher and the fully-active-multijunction (FAM) launcher, using test electron modelling technique. The detailed launched antenna wave spectrum is used as input to the code that computes the dynamics of the electrons in the electric field. Comparison with the LHCD launchers in EAST, operating at 2.45 GHz and 4.6 GHz, has also been made. The simulations show that the PAM-design generates lower flux of fast electrons than FAM-launchers, this could be the consequence of the wider waveguide of PAM-launcher (14.65 mm for Tore-Supra) than FAM-launcher (8 mm for Tore-Supra)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Indium as a surfactant: Effects on growth morphology and background impurity in GaN films grown by ammonia-assisted molecular beam epitaxy

We report on the improvement of the surface morphology of c-plane GaN films grown at high growth rates (~1 µm/h) using ammonia molecular beam epitaxy through a series of growth optimizations as well as the introduction of indium as a surfactant. The indium surfactant was expected to help with the adatom mobility and, thus, provide smoother growth surfaces. Through a combination of varying V/III ratios, In flux, and growth temperatures, an optimal condition for surface morphology, characterized by atomic force microscopy, was achieved. At higher Ga fluxes for fast growth rates (~1 µm/h and beam equivalent pressures of ~5 × 10 –7 Torr), higher ammonia flows were necessary to preserve the surface morphology. In addition, indium was an effective surfactant—reducing the roughness and improving the overall surface morphology. However, excessive indium causes the surface morphology to degrade, potentially due to the enhancement of the Ga desorption from the surface as a result of the reaction of indium with ammonia for high indium fluxes. The indium surfactant also resulted in a reduction of background Si impurity concentrations in the film. These effects allow for the growth of thick drift layers with low background dopant concentrations for vertical GaN power devices.

36 MATERIALS SCIENCE↗

IMPLEMENTING PRIMARY CREEP CALCULATIONS DURING STRESS CHANGES AND REVERSALS IN THE FUEL PERFORMANCE CODE FRAPCON-3

Recently, the creep models in FRAPCON-3.4 were used to model the creep tests performed in IFA-699 up through cycle 4. IFA-699 is an instrumented test rig in the Halden Boiling Water Reactor that is being used to perform in-reactor creep experiments under changing stress conditions. The cladding creep tests in IFA-699 were on four fresh fuel segments with Zircaloy-4, E110, M-MDA, and M5™ cladding. These fuel segments were loaded in a test rig and placed in a PWR loop and operated under PWR conditions. Each of the test fuel rods were connected to gas lines in order to apply tensile and compressive stresses to the cladding. Diameters of the cladding were measured by diameter gages at several intervals to measure the creep behavior of the cladding as a function of time. The creep tests were performed at a temperature of around 360°C and fast neutron flux of 1.8 to 2.4×1017 n/m²-s (depends on specimen location). During the four cycles of operation, hoop stresses of -75, -50, +30, and +110 MPa were applied to the specimens. In addition to providing assessment of the FRAPCON-3.4 creep modeling, the creep model comparisons were also used to provide insight into the nature of primary creep following stress changes, whether creep behavior is symmetric under tensile and compressive loading, and the effect of fast fluence on creep rate. It was determined that creep strain should be calculated as a function of effective stress rather than hoop stress. This accounts for the observed difference between creep under compressive and tensile stress for the same hoop stress. It was also determined that the primary creep changes in proportion to the change in stress following stress change or stress reversal. Finally, it was observed that the irradiation creep rate decreases somewhat with increasing fluence. The creep model in FRAPCON-3.4 has already been developed to be a function of effective stress and includes a term that decreases the irradiation creep rate with increasing fluence. A new mathematical formulation has been developed that is suitable for a fuel performance code to calculate the primary creep strain under conditions of changing stress and stress reversal. The creep model in FRAPCON-3.4 and the formulation for calculating primary creep under changing stress conditions will be described in this paper. Comparisons to data will also be provided.

Geelhood, Kenneth J.↗

Heat flux measurements

A new automated, computer controlled heat flux measurement facility is described. Continuous transient and steady-state surface heat flux values varying from about 0.3 to 6 MW/sq m over a temperature range of 100 to 1200 K can be obtained in the facility. An application of this facility is the development of heat flux gauges for continuous fast transient surface heat flux measurement on turbine blades operating in space shuttle main engine turbopumps. The facility is useful for durability testing at fast temperature transients.

Liebert, Curt H.↗

MAVEN Observations of Magnetic Flux Ropes with a Strong Field Amplitude in the Martian Magnetosheath During the ICME Passage on 8 March 2015

We present initial results of strong field amplitude flux ropes observed by Mars Atmosphere and Volatile EvolutioN (MAVEN) mission around Mars during the interplanetary coronal mass ejection (ICME) passage on 8 March 2015. The observed durations were shorter than 5 s and the magnetic field magnitudes peaked above 80 nT, which is a few times stronger than those usually seen in the magnetosheath barrier. These are the first unique observations that MAVEN detected such flux ropes with a strong field at high altitudes (greater than 5000 km). Across these structures, MAVEN coincidentally measured planetary heavy ions with energies higher than a few keV. The spatial properties inferred from the Grad-Shafranov equation suggest that the speed of the structure can be estimated at least an order of magnitude faster than those previously reported quiet-time counterparts. Hence, the space weather event like the ICME passage can be responsible for generating the observed strong field, fast-traveling flux ropes.

8 March 2015↗

Heat flux measurements

This paper discusses a new automated, computer-controlled heat flux measurement facility. Continuous transient and steady-state surface heat flux values varying from about 0.3 to 6 MW/sq m over a temperature range of 100 to 1200 K can be obtained in the facility. An application of this facility is the development of heat flux gages for continuous fast transient surface heat flux measurement on turbine blades operating in Space Shuttle main engine turbopumps. The facility is also useful for durability testing at fast temperature transients.

Liebert, Curt H.↗

Software Verification of VARPOW

The VARPOW program is a post-processing utility program for DIF3D, specifically DIF3DVARIANT, and it was developed to provide interface files for the thermal analysis program DASSH. The basic methodology of VARPOW is to take the neutron and gamma flux (moments) calculated by DIF3D (or GAMSOR) and combine them with the heating (coefficient) cross sections to calculate the spatial power distributions using the DIF3DVARIANT spatial basis. VARPOW can use the output from GAMSOR (both steady state neutron and gamma flux calculations) or standard DIF3D/REBUS calculations (neutron flux only). The correct approach for defining the power distribution is to use GAMSOR as its purpose was to properly compute the gamma heating throughout the modeled domain. The power desnities calculated by VARPOW are broken into fuel, cladding and coolant terms for which isotope-wise categorization is needed. VARPOW has built in options the user can select for the isotope categorization or VARPOW can import a file that details the isotope categorization. VARPOW can export the solution in the polynomial basis of DIF3D-VARIANT or the monomial basis of DIF3D-VARIANT. Recently the clad neutron damage calculation capability was introduced into VARPOW, and it now allows a pathway to get distributions of clad DPA. The purpose of this work is to verify the power distribution, fast neutron flux and clad DPA results calculated by VARPOW from both the GAMSOR and DIF3D input options and verify that the input and output options are consistent with the manual. Hand calculation and independent numerical calculation are used for this verification work.

Zhong, Zhaopeng [Argonne National Laboratory (ANL)↗

X-RAY ABSORPTION ANALYSIS OF NGC 3516: APPEARANCE OF FAST COMPONENTS WITH INCREASED SOURCE FLUX

By analyzing the X-ray spectra of NGC 3516 from 2001 and 2006 obtained with the HETGS spectrometer on board the Chandra X-ray Observatory, we find that the kinematic structure of the outflow can be well represented by four outflow components intrinsic to NGC 3516: -350 {+-} 100 km s{sup -1}, -1500 {+-} 150 km s{sup -1}, -2600 {+-} 200 km s{sup -1}, and -4000 {+-} 400 km s{sup -1}. A local component at z = 0 could be confused in the spectrum with intrinsic component 3. Components 1 and 2 have a broad range of ionization manifested by absorption from 23 different charge states of Fe. Components 3 and 4 are more highly ionized and show absorption from only nine different charge states of Fe. However, we were able to reconstruct the absorption measure distribution for all four. The total column density of each component is N{sub H} = (1.8 {+-} 0.5) Multiplication-Sign 10{sup 22} cm{sup -2}, (2.5 {+-} 0.3) Multiplication-Sign 10{sup 22} cm{sup -2}, (6.9 {+-} 4.3) Multiplication-Sign 10{sup 22} cm{sup -2}, and (5.4 {+-} 1.2) Multiplication-Sign 10{sup 22} cm{sup -2}, respectively. The fast components 3 and 4 appear only in the high state of 2006 and not in 2001, while the slower components persist during both epochs. On the other hand, there is no significant absorption variability within days during 2001 or 2006. We find that the covering factor plays a minor role for the line absorption.

79 ASTRONOMY AND ASTROPHYSICS↗

Challenges and Solutions for Fast Neutron Irradiation of Bulk Material Specimens

Reactor developers continue to recognize opportunities for further enhancing fast spectrum reactor designs with advanced core materials, but all the material test reactors currently available to the United States are thermal spectrum designs. Fortunately, the Advanced Test Reactor and High Flux Isotope Reactor are versatile high flux facilities where spectral modification strategies can be used to reduce undesirable thermal neutron capture transmutation damage and augment fast flux delivered to specimens. New opportunities to leverage high flux regions and specially designed fast flux boosting experiment configurations can be used to achieve meaningful fast fluences on large specimens in ATR. New optimization potentials can be employed to achieve even higher fluences, albeit for smaller specimens, using thermal neutron filters in HFIR test positions. These capabilities, while not true fast reactors, can provide highly relevant environments for researchers needing to study the effects of fast neutron damage in bulk material specimens.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On0Line Fuel Failure Monitor for Fuel Testing and Monitoring of Gas Cooled Very High Temperature Reactor

IVery High Temperature Reactors (VHTR) utilize the TRISO microsphere as the fundamental fuel unit in the core. The TRISO microsphere (~ 1- mm diameter) is composed of a UO2 kernel surrounded by a porous pyrolytic graphite buffer, an inner pyrolytic graphite layer, a silicon carbide (SiC) coating, and an outer pyrolytic graphite layer. The U-235 enrichment of the fuel is expected to range from 4% – 10% (higher enrichments are also being considered). The layer/coating system that surrounds the UO2 kernel acts as the containment and main barrier against the environmental release of radioactivity. To understand better the behavior of this fuel under in-core conditions (e.g., high temperature, intense fast neutron flux, etc.), the US Department of Energy (DOE) is launching a fuel testing program that will take place at the Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL). During this project North Carolina State University (NCSU) researchers will collaborate with INL staff for establishing an optimized system for fuel monitoring for the ATR tests. In addition, it is expected that the developed system and methods will be of general use for fuel failure monitoring in gas cooled VHTRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fuel performance evaluation of annular metallic fuels for an advanced fast reactor concept

The annular metallic fuel design has been considered as a promising solution to relieve the fuel-cladding mechanical interaction (FCMI) caused by significant swelling of metallic fuels at high burnup. In this paper, the fuel performance of annular metallic fuel with HT9 cladding in a novel advanced fast reactor design optimized for high-burnup performance was evaluated. The BISON code was utilized to perform fuel performance simulations using a modified fuel swelling correlation for conservative evaluation. Three representative fuel pins, which feature highest peak burnup (26.8 % FIMA, fission per initial metal atom), highest fuel temperature (645 degrees C), and highest fast neutron flux (2.68 x 10 15 n/cm 2 ∙s), were investigated. A series of key fuel performance parameters, such as peak fuel temperature, reduction of fuel central void, and cumulative damage fraction (CDF) of the cladding, were predicted for both upper and lower plenum configurations. It is evident that annular fuel design with a lower smeared density is capable of accommodating the significant swelling of metallic fuel at high burnup. Finally, the adoption of a lower plenum configuration effectively lowers the gas pressure inside the rod and reduces the creep damage accumulation in the HT9 cladding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Study of an aSi Flat Panel Detector for Fast Neutron Imaging of Nuclear Waste

Radioactive waste must be characterized to check its conformance for intermediate storage and final disposal according to national regulations. For the determination of radio-toxic and chemo-toxic contents of radioactive waste packages non-destructive analytical techniques are preferentially used. Fast neutron imaging is a promising technique to assay large and dense items providing, in complementarity to photon imaging, additional information on the presence of structures in radioactive waste packages. Therefore the feasibility of a compact Neutron Imaging System for Radioactive waste Analysis (NISRA) using 14 MeV neutrons is studied in a cooperation framework of Forschungszentrum Juelich GmbH, RWTH Aachen University and Siemens AG. However due to the low neutron emission of neutron generators in comparison to research reactors the challenging task resides in the development of an imaging detector with a high efficiency, a low sensitivity to gamma radiation and a resolution sufficient for the purpose. The setup is composed of a commercial D-T neutron generator (Genie16GT, Sodern) with a surrounding shielding made of polyethylene, which acts as a collimator and an amorphous silicon flat panel detector (aSi, 40 x 40 cm{sup 2}, XRD-1642, Perkin Elmer). Neutron detection is achieved using a general propose plastic scintillator (EJ-260, Eljen Technology) linked to the detector. The thermal noise of the photodiodes is reduced by employing an entrance window made of aluminium. Optimal gain and integration time for data acquisition are set by measuring the response of the detector to the radiation of a 500 MBq {sup 241}Am-source. Detector performance was studied by recording neutron radiography images of materials with various, but well known, chemical compositions, densities and dimensions (Al, C, Fe, Pb, W, concrete, polyethylene, 5 x 8 x 10 cm{sup 3}). To simulate gamma-ray emitting waste radiographs in presence of a gamma-ray sources ({sup 60}Co, {sup 137}Cs, {sup 241}Am) were performed. A homemade algorithm was developed to determine a value which is related to the neutron absorption of the sample with the analysis of the raw detector data. The detector was placed 42 cm away from the neutron source. Distance between detector and the samples was 0.5 cm. At the sample position the fast neutron flux was estimated to 9x10{sup 3} n cm{sup -2} s{sup -1} for a neutron emission of 10{sup 8} n s{sup -1}. The acquisition time was 15 minutes. First neutron radiographs were successfully recorded despite the low detector efficiency and low neutron emission. Analysis of the data shows a correlation between the measured signal and determined neutron absorption. Thus discrimination between different materials of same thicknesses may be achieved. The measurements and results will be presented and discussed in details.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

JHR Project: a future Material Testing Reactor working as an International user Facility: The key-role of instrumentation in support to the development of modern experimental capacity

Research and development on fuel and material behaviour under irradiation is a key issue for sustainable nuclear energy in order to meet specific needs by keeping the best level of safety. These needs mainly deal with a constant improvement of performances and safety in order to optimize the fuel cycle and hence to reach nuclear energy sustainable objectives. A sustainable nuclear energy requires a high level of performances in order to meet specific needs such as: - Pursuing improvement of the performances and safety of present and coming water cooled reactor technologies. This will require a continuous R and D support following a long-term trend driven by the plant life management, safety demonstration, flexibility and economics improvement. Experimental irradiations of structure materials are necessary to anticipate these material behaviours and will contribute to their optimisation. - Upgrading continuously nuclear fuel technology in present and future nuclear power plants to achieve better performances and to optimise the fuel cycle keeping the best level of safety. Fuel evolution for generation II, III and III+ is a key stake requiring developments, qualification tests and safety experiments to ensure the competitiveness and safety: experimental tests exploring the full range of fuel behaviour determine fuel stability limits and safety margins, as a major input for the fuel reliability analysis. To perform such accurate and innovative progress and developments, specific and ad hoc instrumentation, irradiation devices, measurement methods are necessary to be set up inside or beside the material testing reactor (MTR) core. These experiments require beforehand in situ and on line sophisticated measurements to accurately determine different key parameters such as thermal and fast neutron fluxes and nuclear heating in order to precisely monitor and control the conducted assays. The new Material Testing Reactor JHR (Jules Horowitz Reactor) currently under construction at CEA Cadarache research centre in the south of France will represent a major Research Infrastructure for scientific studies regarding material and fuel behavior under irradiation. It will also be devoted to medical isotopes production. Hence JHR will offer a real opportunity to perform R and D programs regarding needs above and hence will crucially contribute to the selection, optimization and qualification of these innovative materials and fuels. The JHR reactor objectives, principles and main characteristics associated to specific experimental devices associated to measurement techniques and methodology, their performances, their limitations and field of applications will be presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Influence of specimen size/type on the fracture toughness of five irradiated RPV materials

The Heavy-Section Steel Irradiation (HSSI) Program had previously irradiated five reactor pressure vessel (RPV) steels/welds at fast neutron fluxes of about 4 to 8 x 10 11 n/cm 2 /s (>1 MeV) to fluences from 0.5 to 3.4 10 19 n/cm 2 and at 288 °C. The unirradiated fracture toughness tests were performed by Oak Ridge National Laboratory with 12.7-mm and 25.4-mm thick (0.5T and 1T) compact specimens, while the HSSI Program provided tensile and 5 x 10-mm three-point bend specimens to SCK-CEN for irradiation in the in-pile section of the Belgian Reactor BR2 at fluxes > 10 13 n/cm 2 /s and subsequent testing by SCK-CEN. The BR2 irradiations were conducted at about 2 and 4 x 10 13 n/cm 2 /s with irradiation temperature between 295 °C and 300 °C (water temperature), and to fluences between 6 and 10 x 10 19 n/cm 2 . The irradiation-induced shifts of the Master Curve reference temperatures, ΔT 0 , for most of the materials deviated from the embrittlement correlations much more than expected, motivating the testing of 5 x 10-mm three-point bend specimens of all five materials in the unirradiated condition to eliminate specimen size and geometry as a variable. Tests of the unirradiated small bend specimens resulted in Master Curve reference temperatures, T 0 , 25 °C to 53 °C lower than those from the larger compact specimens, meaning that the irradiation-induced reference temperature shifts, ΔT 0 , were larger than the initial measurements, resulting in much improved agreement between the measured and predicted fracture toughness shifts.

36 MATERIALS SCIENCE↗