Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fast Timing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Multi-Variate LSTM Prediction of Alaska Magnetometer Chain Utilizing a Coupled Model Approach

During periods of rapidly changing geomagnetic conditions electric fields form within the Earth’s surface and induce currents known as geomagnetically induced currents(GICs), which interact with unprotected electrical systems our society relies on. In this study, we train multi-variate Long-Short Term Memory neural networks to predict magnitude of north-south component of the geomagnetic field (|BN|) at multiple ground magnetometer stations across Alaska provided by the SuperMAG database with a future goal of predicting geomagnetic field disturbances. Each neural network is driven by solar wind and interplanetary magnetic field inputs from the NASA OMNI database spanning from 2000–2015 and is fine tuned for each station to maximize the effectiveness in predicting |BN|. The neural networks are then compared against multivariate linear regression models driven with the same inputs at each station using Heidke skill scores with thresholds at the 50, 75, 85, and 99 percentiles for |BN|. The neural network models show significant increases over the linear regression models for |BN| thresholds. We also calculate the Heidke skill scores for d|BN|/dt by deriving d|BN|/dt from |BN| predictions. However, neural network models do not show clear outperformance compared to the linear regression models. To retain the sign information and thus predict BN instead of |BN|, a secondary so-called polarity model is utilized. The polarity model is run in tandem with the neural networks predicting geomagnetic field in a coupled model approach and results in a high correlation between predicted and observed values for all stations. We find this model a promising starting point for a machine learned geomagnetic field model to be expanded upon through increased output time history and fast turnaround times.

Matthew Blandin↗

Real-Time Ammonia and Humidity Monitoring with Ultra-Fast Conductometric Sensors Based on Porphyrin and Phthalocyanine Complexes

Organic semiconductors like porphyrins and phthalocyanines are attracting a wide range of researchers due to their versatile electrical properties and sensing performances in conductometric sensors. In this study, we investigate two types of π-extended porphyrins, which share the same macrocyclic structure but differ in their central metal. These porphyrins are employed as sublayers in bilayer heterojunction devices, with the lutetium bisphthalocyanine complex, LuPc 2 , serving as the common top layer. Remarkably, the central metal in the porphyrin macrocycle significantly influences the solubility of the materials and, consequently, the surface topography of the resulting bilayer heterojunction devices. This structural variation translates into distinct electrical and sensing performances. The device incorporating nickel as metal centre (AM2) demonstrates superior sensitivity towards NH3, with a relative response (RR) of ca. -7% at 90 ppm, an ultra-fast response time of about 9 s, and an impressive limit of detection (LOD) of 250 ppb, whereas, the device that has zinc as metal centre in sublayer (AM3) exhibits RR value of ca. -0.9% at 90 ppm with t 90 of ca. 120 s and LOD of 2 ppm. Both devices are evaluated under randomly varying NH 3 concentration and RH value. The results shows that the AM2-based sensor allows following NH 3 in real-time, while the AM3-based sensor delivers an average concentration over time. On the other hand, the AM2-based sensor exhibits slow kinetics under RH exposure, while the AM3-based sensor precisely mirrors the pattern of random RH changes generated by the software, demonstrating its exceptional responsiveness and accuracy in tracking humidity fluctuations. In conclusion, these findings underscore the critical role of the metal centre in tuning the electrical and sensing properties of the heterojunction devices.

99 GENERAL AND MISCELLANEOUS↗

Novel indium phosphide charged particle detector characterization with a 120 GeV proton beam

Thin film detectors which incorporate semiconductor materials other than silicon have the potential to build upon their unique material properties and offer advantages such as faster response times, operation at room temperature, and radiation hardness. To explore the possibility, promising candidate materials were selected, and particle tracking detectors were fabricated. An indium phosphide detector with a metal-intrinsic-metal structure has been fabricated for particle tracking. The detector was tested using radioactive sources and a high energy proton beam at Fermi National Accelerator Laboratory. In addition to its simplistic design and fabrication process, the indium phosphide particle detector showed a very fast response time of hundreds of picoseconds for the 120 GeV protons, which are comparable to the ultra-fast silicon detectors. This fast-timing response is attributed to the high electron mobility of indium phosphide. Such material properties can be leveraged to build novel detectors with superlative performance.

47 OTHER INSTRUMENTATION↗

High-Voltage Power Supply With Fast Rise and Fall Times

A special-purpose high-voltage power supply can be electronically switched on and off with fast rise and fall times, respectively. The output potential is programmable from 20 to 1,250 V. An output current of 50 A can be sustained at 1,250 V. The power supply was designed specifically for electronically shuttering a microchannel plate in an x-ray detector that must operate with exposure times as short as 1 ms. The basic design of the power supply is also adaptable to other applications in which there are requirements for rapid slewing of high voltages. The power-supply circuitry (see figure) includes a preregulator, which is used to program the output at 1/30 of the desired output potential. After the desired voltage has been set, the outputs of a pulse width modulator (PWM) are enabled and used to amplify the preregulator output potential by 30. The amplification is achieved by use of two voltage doublers with a transformer that has two primary and two secondary windings. A resistor is used to limit the current by controlling the drive voltage of two field-effect transistors (FETs) during turn-on of the PWM. A pulse transformer is used to turn on four FETs to short-circuit four output capacitors when the outputs of the PWM have been disabled. The most notable aspects of the performance of the power supply are a rise time of only 80 s and a fall time of only 60 s at a load current of 50 A or less. Another notable aspect is that the application of a 0-to-5-V square wave to a shutdown pin of the PWM causes the production of a 0-to-1,250-V square wave at the output terminals.

Bearden, Douglas B.↗

A new probe of μ Hz gravitational waves with FRB timing

We propose Fast Radio Burst (FRB) timing, which uses the precision measurements of the arrival time differences of repeated FRB signals along multiple sightlines, as a new probe of gravitational waves (GWs) around nHz to μHz frequencies, with the highest frequency limited by FRB repeating period. The anticipated experiment requires a sightline separation of tens of AU, achieved by sending radio telescopes to space. We find the signal of arrival time difference induced by GWs depends only on the local GWs in the solar system and we can correlate the measurements from different FRB sources or the same source with different repeaters, which leads to a better sensitivity with a larger number of FRB repeaters detected. Here, the projected sensitivity shows this method is a competitive probe in the nHz to μ Hz frequency range. It can fill the 'μHz gap' between pulsar timing arrays and Laser Interferometer Space Antenna (LISA) and is complementary to other proposals of GW detection in this frequency band.

79 ASTRONOMY AND ASTROPHYSICS↗

A new probe of μ Hz gravitational waves with FRB timing

We propose Fast Radio Burst (FRB) timing, which uses the precision measurements of the arrival time differences of repeated FRB signals along multiple sightlines, as a new probe of gravitational waves (GWs) around nHz to μ Hz frequencies, with the highest frequency limited by FRB repeating period. The anticipated experiment requires a sightline separation of tens of AU, achieved by sending radio telescopes to space. We find the signal of arrival time difference induced by GWs depends only on the local GWs in the solar system and we can correlate the measurements from different FRB sources or the same source with different repeaters, which leads to a better sensitivity with a larger number of FRB events detected. The projected sensitivity shows this method is a competitive probe in the nHz to μ Hz frequency range. It can fill the ‘ μ Hz gap’ between pulsar timing arrays and Laser Interferometer Space Antenna (LISA) and is complementary to other proposals of GW detection in this frequency band.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Unified Constitutive Relationship for the Time-dependent Behavior of Fast Breeder Alloys

Constitutive equations based on classical concepts of creep and plasticity generally rest on the assumption that the inelastic strain can be decomposed into two distinct and additive contributions, one time dependent (creep) and the other time dependent (plastic). It is suggested that an approach is to adopt a unified representation in which creep and plasticity are characterized as occurring simultaneously and interactively and time is an essential ingredient throughout. Examples of the inherent time dependency exhibited by some fast breeder alloys at elevated temperature are rate dependency under monotonic and cyclic straining, thermal recovery and strong creep-elasticity interaction. The stron influence of the recent history of plastic straining on stress relaxation is shown.

Robinson, D. N.↗

Computing the transmission zeros of large space structures

The transmission zeros of a large space structure are frequently computed by means of the general-purpose algorithm of Emami-Naeini and Van Dooren (1982). It is shown that careful exploitation of the special form of the equations of motion of structural dynamics leads to an algorithm that is at least 60 times as fast as this when applied to an undamped structure, and 15 times as fast for a lightly damped one.

Williams, Trevor↗

Robust control of flexible space vehicles with minimum structural excitation: On-off pulse control of flexible space vehicles

Both feedback and feedforward control approaches for uncertain dynamical systems (in particular, with uncertainty in structural mode frequency) are investigated. The control objective is to achieve a fast settling time (high performance) and robustness (insensitivity) to plant uncertainty. Preshaping of an ideal, time optimal control input using a tapped-delay filter is shown to provide a fast settling time with robust performance. A robust, non-minimum-phase feedback controller is synthesized with particular emphasis on its proper implementation for a non-zero set-point control problem. It is shown that a properly designed, feedback controller performs well, as compared with a time optimal open loop controller with special preshaping for performance robustness. Also included are two separate papers by the same authors on this subject.

Wie, Bong↗

CRADA Final Report: Ultralong Cycle Life and Ultrafast Charging Batteries to Electrify High Duty-Cycle, Mobile Platforms

As part of the Cyclotron Road program, Tyfast Energy Corp. aimed to investigate the Li 3 V 2 O 5 (LVO) anode material for next generation lithium batteries. State of the art and fast charging lithium-ion batteries are based on the lithium titanate or Li 4 Ti 5 O 12 (LTO) anode chemistry. LTO cells demonstrate fast charging times (<6 mins), long cycle life (>20,000 cycles), but at the expense of very low energy density (<200Wh/L, <80Wh/kg). Silicon anodes have the promise of achieving fast charging times, however, issues with cycling stability in combination with fast charging is unknown. LVO has unique properties that enable new performance window for lithium batteries. First, LVO operates at an average potential of 0.6V vs. Li/Li + , well above the Li-metal plating region allowing ultrafast charge capability without sacrificing safety. Second, the LVO has a high specific capacity of 250 mAh/g making battery pack energy density equivalent with current high-energy Li-ion chemistries.

25 ENERGY STORAGE↗

Statistical aspects of solar flares

A survey of the statistical properties of 850 H alpha solar flares during 1975 is presented. Comparison of the results found here with those reported elsewhere for different epochs is accomplished. Distributions of rise time, decay time, and duration are given, as are the mean, mode, median, and 90th percentile values. Proportions by selected groupings are also determined. For flares in general, mean values for rise time, decay time, and duration are 5.2 + or - 0.4 min, and 18.1 + or 1.1 min, respectively. Subflares, accounting for nearly 90 percent of the flares, had mean values lower than those found for flares of H alpha importance greater than 1, and the differences are statistically significant. Likewise, flares of bright and normal relative brightness have mean values of decay time and duration that are significantly longer than those computed for faint flares, and mass-motion related flares are significantly longer than non-mass-motion related flares. Seventy-three percent of the mass-motion related flares are categorized as being a two-ribbon flare and/or being accompanied by a high-speed dark filament. Slow rise time flares (rise time greater than 5 min) have a mean value for duration that is significantly longer than that computed for fast rise time flares, and long-lived duration flares (duration greater than 18 min) have a mean value for rise time that is significantly longer than that computed for short-lived duration flares, suggesting a positive linear relationship between rise time and duration for flares. Monthly occurrence rates for flares in general and by group are found to be linearly related in a positive sense to monthly sunspot number. Statistical testing reveals the association between sunspot number and numbers of flares to be significant at the 95 percent level of confidence, and the t statistic for slope is significant at greater than 99 percent level of confidence. Dependent upon the specific fit, between 58 percent and 94 percent of the variation can be accounted for with the linear fits. A statistically significant Northern Hemisphere flare excess (P less than 1 percent) was found, as was a Western Hemisphere excess (P approx 3 percent). Subflares were more prolific within 45 deg of central meridian (P less than 1 percent), while flares of H alpha importance or = 1 were more prolific near the limbs greater than 45 deg from central meridian; P approx 2 percent). Two-ribbon flares were more frequent within 45 deg of central meridian (P less than 1 percent). Slow rise time flares occurred more frequently in the western hemisphere (P approx 2 percent), as did short-lived duration flares (P approx 9 percent), but fast rise time flares were not preferentially distributed (in terms of east-west or limb-disk). Long-lived duration flares occurred more often within 45 deg 0 central meridian (P approx 7 percent). Mean durations for subflares and flares of H alpha importance or + 1, found within 45 deg of central meridian, are 14 percent and 70 percent, respectively, longer than those found for flares closer to the limb. As compared to flares occurring near cycle maximum, the flares of 1975 (near solar minimum) have mean values of rise time, decay time, and duration that are significantly shorter. A flare near solar maximum, on average, is about 1.6 times longer than one occurring near solar minimum.

Wilson, Robert M.↗

Commissioning a time-gated camera for fast neutron beamline spatial-energy characterization at LANSCE-WNR spallation source

An energy-resolved fast neutron beam imaging diagnostic has been successfully commissioned at the Weapons Neutron Research (WNR) spallation source within the Los Alamos Neutron Science Center (LANSCE) facility. This diagnostic replaces the existing analog phosphor image plates, which integrate across all neutron energies, as well as other particles, with a near-real-time energy-sensitive imaging capability. The system uses a fast plastic scintillator coupled with an intensified CCD camera. Specifically, the Teledyne Pi-MAX4 camera is coupled with either a 4 mm thick Eljen (EJ) 204 or 228 plastic scintillator. These scintillators are most sensitive to the fast neutrons (0.8-800 MeV) directly from the spallation source rather than low energy background radiation. Experimentally, these plastic scintillators were shown to have sufficiently fast decay to differentiate the bright gamma flash from the spallation neutrons. The spatial resolution is dominated by neutron beam divergence, with minimal additional contributions from scatter and light divergence. The system successfully resolved changes in neutron beam characteristics caused by intentional proton steering variations. Additionally, simulations of scintillator light yield as a function of thickness conducted using PHITS (with Scinful-QMD package) found that increasing scintillator thickness from 4 mm to 6 or 8 mm could potentially increase brightness ~ 3x. This may be explored if there is a need to reduce image acquisition time from several minutes to under one minute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New broadband square-law detector

Compact device has wide dynamic range, accurate square-law response, good thermal stability, high-level dc output with immunity to ground-loop problems, ability to insert known time constants for radiometric applications, and fast response times compatible with computer systems.

Reid, M. S.↗

Synergistic effects of Al, Ga, and In doping on ZnO nanorod arrays grown via citrate-assisted hydrothermal technique for highly efficient and fast scintillator screens

To be used as efficient alpha particle scintillator in the fields of nuclear security, nuclear nonproliferation and high-energy physics, scintillator screens must have high light output and fast decay properties. While there has been a great deal of progress in scintillation efficiency, achieving fast decay time properties are still a challenge. In this work, the near band edge (NBE) UV luminescence and alpha particle induced scintillation properties of vertically aligned densely packed ZnO nanorods (NRs) doped with Al, Ga, and In have been thoroughly investigated. The high crystalline hexagonal wurtzite structure with a strong orientation through the c -axis plane (002) and aspect ratios in the range 13–22 have been observed for all ZnO NRs. Electron paramagnetic resonance (EPR) analysis exhibited paramagnetic signals at g ≈ 1.96 for all ZnO NRs. A cost effective green hydrothermal synthesis technique was employed to grow well-aligned NRs. Using citrate as an additive acting as a strong reducing agent in the solution during the crystal growth, defects on the surface are significantly suppressed, thereby enhancing the NBE UV emission. Significantly higher NBE UV emission was observed from the top surface of ZnO NRs in cathodoluminescence (CL) microscopy. Results show that citrate assisted donor doping of ZnO NRs not only reduces the defect emission and NBE self-absorption, but also induces fast decay time (~ 600–700 ps), which makes ZnO NRs a good candidate for fast alpha particle scintillator screens used in associated particle imaging for time and direction tagging of individual neutrons generated in D–T and D–D neutron generators.

36 MATERIALS SCIENCE↗

Fast interactive real-time volume rendering of real-time three-dimensional echocardiography: an implementation for low-end computers

Real-time three-dimensional echocardiography (RT3DE) is an innovative cardiac imaging modality. However, partly due to lack of user-friendly software, RT3DE has not been widely accepted as a clinical tool. The object of this study was to develop and implement a fast and interactive volume renderer of RT3DE datasets designed for a clinical environment where speed and simplicity are not secondary to accuracy. Thirty-six patients (20 regurgitation, 8 normal, 8 cardiomyopathy) were imaged using RT3DE. Using our newly developed software, all 3D data sets were rendered in real-time throughout the cardiac cycle and assessment of cardiac function and pathology was performed for each case. The real-time interactive volume visualization system is user friendly and instantly provides consistent and reliable 3D images without expensive workstations or dedicated hardware. We believe that this novel tool can be used clinically for dynamic visualization of cardiac anatomy.

NASA Discipline Cardiopulmonary↗