Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fiber laser”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

MicroResonators for Compacts Optical Sensors (μRCOS)

As the demand for continuous, in-situ surveillance of health of systems and environments rapidly increases, miniaturized sensors with fast responses are sought. Optical dielectric resonators supporting Whispering Gallery Modes (WGMs) have exceptional properties, like very high-power density, very narrow spectral linewidth, and extremely small mode volume. As the footprint of these sensors is drastically reduced, measurements of microvolumes samples with dramatic reduction in analysis time are possible, enabling large numbers of parallel analyses using microarrays. The high sensitivity and speed of WGM resonators combined with the ability to detect molecules in their native state have great future potential for basic and applied research such as reliable single molecule, trace-gas detection, environmental monitoring, chemical threat sensing, and biodefense Such appealing peculiarities motivated us developing WMG resonators (WGMRs) for Cavity Enhanced Absorption Spectroscopy (CEAS) for chem-bio detection. Specifically, we designed and batch-fabricated microspheres and fiber tapers for resonances excitation. We successfully detected gases (N 2 and CO 2 ) in customized environmental chambers, and bio-organisms (Inf. A and E. Coli) with integrated microfluidic systems. Background calibration and environmental isolation were always accounted for in proving the performances.

36 MATERIALS SCIENCE↗

Improving Chirped Fiber Bragg Grating Resolution for Position-Sensitive Sensors in Shock- and Detonation-Driven Experiments

Chirped fiber Bragg gratings (CFBGs) are robust diagnostic sensors that are widely used to track detonation-driven and shock wave propagation. CFBGs are inscribed with a linearly chirped periodic index of refraction changes that alter the Bragg wavelength along the length of the probe. The light return of each individual Bragg element is captured by a detector at a unique time to map the full reflected spectrum. The CFBG spectrum is measured with a dispersive Fourier transform of the reflected light that temporally stretches the spectrum to increase spatial resolution and make a one-to-one map of the wavelength on a time axis. Here, we propose an improvement of CFBG temporal resolution by incorporating two co-linear laser pulses with orthogonal polarization states and a 5 ns time offset. The two separate signals were split and tracked by two separate detectors. An oscilloscope captured good separation in the signals, and two separate spectrograms were generated and interleaved in the post-processing of the data. This novel technique doubled the CFBG temporal resolution and led to a doubled location resolution. As a proof-of-concept of this technique, the resolution improvement was compared between standard CFBG measurements and the two polarization states method on a position-sensitive CFBG sensor. CFBG resolution doubling will advance sensor capabilities and will have a direct impact on improving capture and analysis in dynamic, high-explosive experiments.

42 ENGINEERING↗

MicroResonators for Compacts Optical Sensors (μRCOS)

As the demand for continuous, in-situ surveillance of health of systems and environments rapidly increases, miniaturized sensors with fast responses are sought. Optical dielectric resonators supporting Whispering Gallery Modes (WGMs) have exceptional properties, like very high-power density, very narrow spectral linewidth, and extremely small mode volume. As the footprint of these sensors is drastically reduced, measurements of microvolumes samples with dramatic reduction in analysis time are possible, enabling large numbers of parallel analyses using microarrays. The high sensitivity and speed of WGM resonators combined with the ability to detect molecules in their native state have great future potential for basic and applied research such as reliable single molecule, trace-gas detection, environmental monitoring, chemical threat sensing, and biodefense Such appealing peculiarities motivated us developing WMG resonators (WGMRs) for Cavity Enhanced Absorption Spectroscopy (CEAS) for chem-bio detection. Specifically, we designed and batch-fabricated microspheres and fiber tapers for resonances excitation. We successfully detected gases (N 2 and CO 2 ) in customized environmental chambers, and bio-organisms (Inf. A and E. Coli) with integrated microfluidic systems. Background calibration and environmental isolation were always accounted for in proving the performances.

36 MATERIALS SCIENCE↗

Evaluation and Demonstration of Intrusion Detection for Spent Fuel Storage Facilities

The IAEA recommends dual containment and surveillance (C/S) systems for difficult to access or difficult to measure spent fuel storage areas. However, many storage areas have limitations that prevent traditional secondary C/S systems, such as radiation levels too high for inspectors to apply individual Tamper Indicating Devices (TID) or have physical impedances to the use of TIDs. Recent developments in C/S technology include Laser Curtain for Containment (LCCT) technology implemented at Atucha-1 power plant in Argentina. The LCCT is a new approach to perimeter-wide C/S and the IAEA has granted provisional approval for its use as one of two required C/S systems. This proposal focuses on investigating and testing new and evolving completely passive (or ultra-low power) tamper indicating systems that will provide backup C/S to the LCCT even during power outages. An investigation of Commercial Off The Shelf (COTS) technology will be conducted to identify readily available options. Optically Stimulated Luminescence (OSL) fibers will also be investigated. OSL fibers are a passive technology that can measure radiation dose by knocking an electron into a metastable state where it remains until the fiber is interrogated with light. The goal of this project would be to investigate COTS technologies that can be used in low or no power scenarios for radiation detection as well as test and evaluate OSL technology, which can operate passively in no power scenarios. Limitations for each technology will be determined and documented in an effort to determine the best technology for spent fuel storage monitoring.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental generation of polarization entanglement from spontaneous parametric down-conversion pumped by spatiotemporally highly incoherent light

Here, we investigate the cross influence of the pump coherence on the entanglement produced from spontaneous parametric down-conversion (SPDC) in different degrees of freedom (DOFs). We experimentally demonstrate the generation of polarization entanglement from SPDC pumped by a spatiotemporally highly incoherent (STHI) light-emitting diode. Our quantum state tomography measurements using multimode collection fibers to avoid postselection yield a two-qubit state with the concurrence of 0.531 ± 0.006 and purity of 0.647 ± 0.005, in excellent agreement with our theoretically predicted concurrence of 0.552 and purity of 0.652. We find that using an STHI pump reduces the entanglement and purity of the output polarization two-qubit state due to a coupling between the spatiotemporal and polarization DOFs introduced by the birefringence and dispersion of the nonlinear crystal. The viability of SPDC with STHI pumps is important for two reasons: (i) STHI sources are ubiquitous and available at a wider range of wavelengths than lasers, and (ii) the generated STHI polarization-entangled two-photon states could potentially be useful in long-distance quantum communication schemes due to their robustness to scattering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-invasive Pipe Pressure Monitoring for Safeguards

Our project explores a new solution to complement current safeguards toolbox by independently, and noninvasively, determining the pressure inside uranium hexafluoride (UF 6 )-carrying Gas Centrifuge Enrichment Plant (GCEP) pipes. Proof-of-principle, non-invasive pipe pressure monitoring tests were conducted through measurements of hoop and axial strain using an optical-interference dilatometry technique based on fiber Bragg gratings (FBGs) inscribed in the core of telecommunication-type 125 µm diameter optical fibers. The fibers were affixed to commercial stainless steel and aluminum tubes and pipes of the type expected to be found at GCEP’s, each measuring four inches in diameter. When the internal air pressure in the pipes changes their external diameter and length follow, and the pitch in the FBG shrinks and/or expands accordingly. In turn, these changes result in a shift of the light wavelength reflected by the FBGs. Several FBGs physically attached to the pipe, as well as control FBGs not attached, were interrogated during the process using state-of-the-art commercial interrogators that operate on swept-wavelength laser technology. Strains measured were contrasted against calculations based on the known elastic and mechanical properties of the pipes. Good agreement is found, and strategies are proposed for further improvement of the experimental resolution as well as future implementation of this novel approach for GCEP safeguards.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Crystallization of ApoA1 and ApoE4 Nanolipoprotein Particles and Initial XFEL-Based Structural Studies

Nanolipoprotein particles (NLPs), also called “nanodiscs”, are discoidal particles with a patch of lipid bilayer corralled by apolipoproteins. NLPs have long been of interest due to both their utility as membrane-model systems into which membrane proteins can be inserted and solubilized and their physiological role in lipid and cholesterol transport via high-density lipoprotein (HDL) and low-density lipoprotein (LDL) maturation, which are important for human health. Serial femtosecond crystallography (SFX) at X-ray free electron lasers (XFELs) is a powerful approach for structural biology of membrane proteins, which are traditionally difficult to crystallize as large single crystals capable of producing high-quality diffraction suitable for structure determination. To facilitate understanding of the specific role of two apolipoprotein/lipid complexes, ApoA1 and ApoE4, in lipid binding and HDL/LDL particle maturation dynamics, and to develop new SFX methods involving NLP membrane protein encapsulation, we have prepared and crystallized homogeneous populations of ApoA1 and ApoE4 NLPs. Crystallization of empty NLPs yields semi-ordered objects that appear crystalline and give highly anisotropic and diffuse X-ray diffraction, similar to fiber diffraction. Several unit cell parameters were approximately determined for both NLPs from these measurements. Thus, low-background, sample conservative methods of delivery are critical. Here we implemented a fixed target sample delivery scheme utilizing the Roadrunner fast-scanning system and ultra-thin polymer/graphene support films, providing a low-volume, low-background approach to membrane protein SFX. This study represents initial steps in obtaining structural information for ApoA1 and ApoE4 NLPs and developing this system as a supporting scaffold for future structural studies of membrane proteins crystalized in a native lipid environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing Enhanced Raman Spectroscopy to Detect and Measure NOW Pheromones (CPRB 2022 proposal)

Insect sex pheromones are chemical compounds that insects release to attract their partners over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts. These pheromone-based strategies can include monitoring, mating disruption, mass trapping, attract-and-kill and push-pull. There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can be effectively used to reduce crop damage by this pest. Just how mating disruption works is not fully established and likely varies across products and target species. For instance, the extent to which synthetic pheromones compete with natural pheromone is not well understood, or in the case of monitoring, how efficaciously the insect follows the diffusing plumes, especially across large blocks and at plot borders. Furthermore, there may be specific conditions under which poor or impeded diffusion of synthetic pheromone diminishes the disruption effect, which could result in some males effectively locating females for reproduction. At the same time, many commercially available synthetic lures are also available, and growers have been effectively using them to track population development – although the attractive range of these lures remains unclear. That is, while pheromone lures can attract many moths, the relationship between trap capture and local populations, much less crop damage, remains unclear. Regardless of the emission source (aerosol puffers, meso emitters, lures etc.), we currently lack the ability to fully understand how these synthetic pheromone compounds diffuse away from their point-source of emission – and subsequently how this might affect the efficacy of mating disruption and/or the accuracy of monitoring efforts. Raman spectroscopy (RS) may offer a means to detect synthetic pheromone because of its analytical properties and recent technological advancements. In combination with nanostructured probes, RS has a demonstrated capability to detect volatiles at extremely low concentrations. While other methods for detecting pheromones have proven to be successful, such analytical methods like mass spectrometry (MS) gas chromatography (GC) require sampling in the fields and are not real-time. Other methods such as EAG/ EAD are also invasive (use antennas) but are of course valuable. Opto-electronic, micro and nano sensors just recently enticed interest. We fall in this latter category, proposing the use of optical spectroscopy (Raman) in a fiber aided by nanostructures to provide a chemical fingerprint without transductions and in real-time (i.e. no sampling). To date, we have been able to generate Raman signatures for the main chemicals in synthetic pheromones (a first for science, to the best of our knowledge), observe their trends at different concentrations, and also provide a clear distinction of such signatures in mixed samples via Principal Component Analysis (PCA) – all of which strengthens our conclusions on the ability of RS to detect emissions in more realistic conditions. We also established processes to enhance the detection sensitivity via preconcentration with Solid Phase Micro Extraction (SPME) fibers and Surface Enhanced Raman Spectroscopy (SERS) to increase the overall optical signals. Furthermore, we explored limitations and requirements for detecting from dispensers, lures, or live moths, including Dept. of Energy and CA State regulatory approvals. Finally, we setup some of our first “orchard in a box” experiments to measure pheromone diffusion along with developing appropriate models.

42 ENGINEERING↗

Single-element balanced detector giving 65 dB CMRR at 30 MHz

We present a simple design for a single-element balanced detector (BD) that utilizes optical fibers in the sensing and reference channels with path length differences set to detect the differential signal at a desired frequency. With this approach, we easily achieve a common-mode rejection ratio of 65 dB, corresponding to the shot-noise limit of our setup. The CMRR demonstration is made in the MHz frequency range but could be extended to the kHz or GHz range. Using a single detector, the BD achieves stable CMRR over extended periods and does not require careful matching of detectors and amplification electronics. We demonstrate the single-element balanced detector design using the optical Kerr effect induced by a 30 MHz pulsed laser, showing a significant improvement over similar experiments using a commercial balanced detector.

Badilla-Nunez, Kelly [Georgia Institute of Technol↗

Biophotonic rogue waves in red blood cell suspensions

Rogue waves are ubiquitous in nature, appearing in a variety of physical systems ranging from acoustics, microwave cavities, optical fibers, and resonators to plasmas, superfluids, and Bose–Einstein condensates. Unlike nonlinear solitary waves, rogue waves are extreme events that can occur even without nonlinearity by, for example, spontaneous synchronization of waves with different spatial frequencies in a linear system. Here, we report the observation of rogue-wave-like events in human red blood cell (RBC) suspensions under weak light illumination, characterized by an abnormal L-shaped probability distribution. Such biophotonic extreme events arise mostly due to the constructive interference of Mie-scattered waves from the suspended RBCs, whose biconcave shape and mutable orientation give rise to a time-dependent random phase modulation to an incident laser beam. We numerically simulate the beam propagation through the colloidal suspensions with added disorder in both spatial and temporal domains to mimic random scattering due to Brownian motion. In addition, at high power levels, nonlinear beam self-focusing is also observed, leading to a dual-exponential probability distribution associated with the formation of multiple soliton-like spots. Such rogue wave events should also exist in environments with cells of other species such as swimming bacteria, and understanding of their underlying physics may lead to unexpected biophotonic applications.

59 BASIC BIOLOGICAL SCIENCES↗

Delamination imaging in composites using cross-correlation method by non-contact air-coupled Lamb waves

Abstract This paper presents a cross-correlation damage detection technique using damage scattered waves of all directions cross-correlate with the incident waves for delamination imaging in carbon fiber reinforced polymer (CFRP) composite plate. The presented imaging can not only detect the delamination but also precisely quantify the damage with locations and sizes. First, a CFRP composite sample with interlaminar delamination by inserting the Teflon layer is designed and manufactured in house using the hot-press machine. And a three-dimensional model of composite sample is simulated using the finite element method. Next, the cross-correlation imaging algorithm is introduced in detail, and the cross-correlation imaging proof-of-concept study is conducted with the simulated Lamb waves in the composite sample. Finally, a fully non-contact air-coupled transducer and scanning laser Doppler vibrometer system with a single-mode Lamb wave method is established to actuate and sense the interrogating Lamb waves in the structure. The imaging method is experimentally implemented for the one delamination and two delaminations imaging and quantification.

Instruments & Instrumentation↗

Laser-Induced Breakdown Spectroscopy (LIBS) Sensing for Environmental and Subsurface Monitoring

Groundwater monitoring is essential to timely and accurately reflect the current situations and the trends of water quality. However, the long-term stability and survival of any potential in-situ monitoring method is threatened by the harsh conditions and the groundwater monitoring in downhole environments poses numerous challenges to the sensor community. Laser induced breakdown spectroscopy (LIBS) has been demonstrated as a promising technology for chemical monitoring in high-temperature high-pressure (HTHP) environments and hard to reach places. The technique demonstrates several advantages, such as rapid, real-time, in-situ, and simultaneous detection of multiple elements with simple or no sample preparation. This chapter includes a brief review of the field-portable LIBS systems, and development of a compact, robust, and simple LIBS instrument for downhole HTHP water quality monitoring. The fieldable prototype sensor is tested in an onsite monitoring well where trace elements’ concentrations are tracked over an extended period. The testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements and collection times, and Limits of Detection (LODs) that are comparable to those of tabletop LIBS instruments. In addition to groundwater quality monitoring, the fabricated LIBS-based sensor could have widespread sub-surface detection applications.

Jain, Jinesh [NETL Site Support Contractor, Nation↗

Development of Laser-Induced Breakdown Spectroscopy for the Californium-252 Supply Program

Calibration-free–laser-induced breakdown spectroscopy (CF-LIBS) is suggested as an alternative to traditional LIBS because it does not rely on calibration curves and instead relies on previously reported parameters called transition probabilities. Transition probabilities are fundamental parameters that describe the probability a specific transition from an upper energy to a lower energy will occur. These values act as internal calibrations and allow concentrations to be calculated based on the plasma temperature and electron density, which can be determined from Saha-Boltzmann methods. CF-LIBS provides the ability to perform elemental concentration estimations on samples without the need for chemical dilutions and only nanograms of material are ablated into the plasma. These benefits can be applied remotely inside hot cells, glove boxes, and radiation hoods through optical fibers. This report summarizes recent efforts to develop CF-LIBS methods for future applications within Oak Ridge National Laboratory’s radioisotope production portfolio, such as the Cf-252 Supply Program. Summaries are provided for the developed Python scripts for data analysis and two studies employing these programs to determine unreported transition probabilities of relevant lanthanides. Additionally, a review of fiber-delivered LIBS and a discussion of a LIBS fiber probe design are provided.

07 ISOTOPE AND RADIATION SOURCES↗

Method for boosting dispersive spectrograph stability 1000× using interferometry with crossfaded pairs of delays

We demonstrate a key step along a technical route to achieving cm/s scale accuracy for astronomical spectrographs over long (multi-year) time scales, which is critical for the Doppler characterization of Earth sized exoplanets, and measurement of small cosmic redshift drift over many years. This same technique also enables searching exoplanet atmospheres for biosignificant molecules in direct planet imaging using, otherwise, insufficiently low resolution and drift prone dispersive (grating or prism) spectrographs. Using a method called crossfading for externally dispersed interferometers (EDIs) to get highly robust spectra, we recently demonstrated a factor of 1000 x reduction in the net shift of an EDI measured ThAr line to a deliberate simulated wavelength translation of the detector. This 1000 x gain in disperser stability can be combined with conventional stability gains afforded by fiber scramblers, vacuum tanks, and thermal control, to provide an additional 1 to 3 orders of magnitude reduction in the net point spread function shift drift. Crossfading combines high- and low-delay fringing signals that react oppositely in phase to cancel their net reaction to a detector wavelength drift. This can be implemented by an interferometer addition to a facility spectrograph.

79 ASTRONOMY AND ASTROPHYSICS↗

Accumulation of microplastics in soil after long-term application of biosolids and atmospheric deposition

Land-applied biosolids can be a considerable source of microplastics in soils. Previous studies reported microplastics accumulation in soils from biosolid application, however, little is known about the contribution of atmospherically deposited microplastics to agricultural soils. In this study, we quantified and characterized microplastics in soils that have been amended with biosolids over the past 23 years. We also collected atmospheric deposition samples to determine the amount and type of plastics added to soils through atmospheric input over a period of about 2 years. Soil samples were taken from a replicated field trial where biosolids have been applied at rates of 0, 4.8, 6.9, and 9.0 t/ha every second crop. The biosolids were anaerobically digested and dewatered, and were applied by spreading onto the soil surface. Soil and atmospheric samples were extracted for microplastics by Fenton's reaction to remove organic matter followed by flotation in a zinc chloride solution to separate plastic from soil particles. Samples were analyzed for microplastics by optical microscopy and Laser Direct Infrared Imaging Analysis (LDIR). The mean number of microplastics identified from biosolids samples was 12,000 particles/kg dry biosolids. The long-term applications of biosolids to the soil led to mean plastics concentrations of 383, 500, and 361 particles/kg dry soil in the 0–10 cm depth for low, medium, and high biosolids application rates, respectively. These plastic concentrations were not significantly different from each other, but significantly higher than those found in non biosolids-amended soil (117 particles/kg dry soil). The dominant plastic types by number found in biosolids were polyurethane, followed by polyethylene, and polyamide. The most abundant plastics in soil samples were polyurethane, polyethylene terephthalate, polyamide, and polyethylene. Atmospheric deposition contributed to 15 particles/kg dry soil per year and was mainly composed of polyamide fibers. In conclusion, this study shows that long-term application of biosolids led to an accumulation of microplastics in soil, but that atmospheric deposition also contributes a considerable input of microplastics.

54 ENVIRONMENTAL SCIENCES↗

Development of Optical Fiber-Based Sensors for Nuclear Microreactor Structural Health Monitoring

This report provides an experimental assessment of two different optical fiber–based acoustic sensors that are being investigated for application in nuclear microreactors to enhance structural health monitoring capabilities. Optical fibers are resilient in high-temperature and high-radiation environments, have a small sensor footprint, are immune to electromagnetic interference, and are capable of spatially distributed sensing. The two sensors investigated here are (1) Fabry–Pérot Cavities (FPCs) between two copper-coated fibers, embedded in nickel capillary tubes and (2) type-I fiber Bragg grating (FBG) arrays contained within metal capillary tubes. These sensors can be interrogated using low-coherence interferometry or swept wavelength interferometry, respectively, to measure the resonant frequencies of the components or systems to which these sensors are bonded. The FPC developed herein has been subjected to temperatures up to nearly 800°C while tack-welded to a tubular test specimen. Even at the highest temperatures, the measured resonant frequencies compared well with those obtained using an accelerometer that was bonded to an unheated portion of the specimen. The FBG array was tested in multiple bonding configurations to a tubular test specimen, all at room temperature, with the understanding that high temperature (i.e., type II) FBGs could be used to obtain similar data at high temperatures; the FBG array data were validated with noncontact laser vibrometry, which is being used at Los Alamos National Laboratory to relate acoustic signatures to component stresses and/or structural defects. The goal of this work is to identify the most promising techniques that are also compatible with operation in a microreactor environment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗

422 Million intrinsic quality factor planar integrated all-waveguide resonator with sub-MHz linewidth

High quality-factor (Q) optical resonators are a key component for ultra-narrow linewidth lasers, frequency stabilization, precision spectroscopy and quantum applications. Integration in a photonic waveguide platform is key to reducing cost, size, power and sensitivity to environmental disturbances. However, to date, the Q of all-waveguide resonators has been relegated to below 260 Million. Here, we report a Si 3 N 4 resonator with 422 Million intrinsic and 3.4 Billion absorption-limited Qs. The resonator has 453 kHz intrinsic, 906 kHz loaded, and 57 kHz absorption-limited linewidths and the corresponding 0.060 dB m -1 loss is the lowest reported to date for waveguides with deposited oxide upper cladding. These results are achieved through a careful reduction of scattering and absorption losses that we simulate, quantify and correlate to measurements. This advancement in waveguide resonator technology paves the way to all-waveguide Billion Q cavities for applications including nonlinear optics, atomic clocks, quantum photonics and high-capacity fiber communications.

36 MATERIALS SCIENCE↗