At least 307 records · Page 17

Hanford Roadside Bird Surveys Report for Calendar Year 2012

The U.S. Department of Energy’s Hanford Site is unique in that public access is restricted, there is no industrial development unrelated to the cleanup efforts, and agriculture activities do not occur within its boundaries. The Hanford Site contains a variety of bird habitats that include: basalt outcrops, riparian streams and springs, shrub-steppe on slopes and on plains, sand dunes and blowouts, and abandoned fields or disturbed areas (PNL-8942). The Hanford Site provides large expanses of habitat for shrub-steppe birds that depend on either mature stands of sagebrush or areas with at least some component of native grasses in the understory (The Nature Conservancy 1999). In some portions of the Hanford Site, human activities such as farming, urbanization, and industrial development have greatly decreased the amount of natural habitat that endemic birds require for survival. In turn, the riparian areas of the Hanford Site may have been improved by planting larger trees in homesteads and towns. These trees provide nesting locations, feeding areas and roosting spots for many species. Ultimately, human activities associated with the development of the Hanford Site, in addition to large fires that have occurred in the last 30 years, have caused the populations of a number of shrub-steppe birds to decrease, and some, such as the Greater Sage Grouse (Centrocercus urophasianus) have been locally extirpated. Federal laws including the Migratory Bird Treaty Act of 1918 still provide protection of these species. Thus, monitoring is essential to not only maintain current biological information on abundance and distribution of these species on the Hanford Site, but also to ensure compliance with protection regulations and to inform future protection and management efforts.

54 ENVIRONMENTAL SCIENCES↗

Modelling and mitigating dose to firefighters from inhalation of radionuclides in wildland fire smoke

Firefighters responding to wildland fires where surface litter and vegetation contain radiological contamination will receive a radiological dose by inhaling resuspended radioactive material in the smoke. This may increase their lifetime risk of contracting certain types of cancer. Using published data, we modelled hypothetical radionuclide emissions, dispersion and dose for 70th and 97th percentile environmental conditions and for average and high fuel loads at the Savannah River Site. We predicted downwind concentration and potential dose to firefighters for radionuclides of interest ( 137 Cs, 238 Pu, 90 Sr and 210 Po). Predicted concentrations exceeded dose guidelines in the base case scenario emissions of 1.0 × 10 7 Bq ha –1 for 238 Pu at 70th percentile environmental conditions and average fuel load levels for both 4- and 14-h shifts. Under 97th percentile environmental conditions and high fuel loads, dose guidelines were exceeded for several reported cases for 90 Sr, 238 Pu and 210 Po. Potential for exceeding dose guidelines was mitigated by including plume rise (>2 m s –1 ) or moving a small distance from the fire owing to large concentration gradients near the edge of the fire. As a result, our approach can quickly estimate potential dose from airborne radionuclides in wildland fire and assist decision-making to reduce firefighter exposure.

60 APPLIED LIFE SCIENCES↗

Status and prospects for renewable energy using wood pellets from the southeastern United States

Abstract The ongoing debate about costs and benefits of wood‐pellet based bioenergy production in the southeastern United States ( SE USA ) requires an understanding of the science and context influencing market decisions associated with its sustainability. Production of pellets has garnered much attention as US exports have grown from negligible amounts in the early 2000s to 4.6 million metric tonnes in 2015. Currently, 98% of these pellet exports are shipped to Europe to displace coal in power plants. We ask, ‘How is the production of wood pellets in the SE USA affecting forest systems and the ecosystem services they provide?’ To address this question, we review current forest conditions and the status of the wood products industry, how pellet production affects ecosystem services and biodiversity, and what methods are in place to monitor changes and protect vulnerable systems. Scientific studies provide evidence that wood pellets in the SE USA are a fraction of total forestry operations and can be produced while maintaining or improving forest ecosystem services. Ecosystem services are protected by the requirement to utilize loggers trained to apply scientifically based best management practices in planning and implementing harvest for the export market. Bioenergy markets supplement incomes to private rural landholders and provide an incentive for forest management practices that simultaneously benefit water quality and wildlife and reduce risk of fire and insect outbreaks. Bioenergy also increases the value of forest land to landowners, thereby decreasing likelihood of conversion to nonforest uses. Monitoring and evaluation are essential to verify that regulations and good practices are achieving goals and to enable timely responses if problems arise. Conducting rigorous research to understand how conditions change in response to management choices requires baseline data, monitoring, and appropriate reference scenarios. Long‐term monitoring data on forest conditions should be publicly accessible and utilized to inform adaptive management.

09 BIOMASS FUELS↗

Preparation and testing of corrosion and spallation-resistant coatings

The goal of this project was to take a recently developed method of bonding oxide dispersion-strengthened (ODS) FeCrAl plating to nickel superalloys closer to commercial use in syngas-fired turbines. The project was designed to better understand and develop the bonding process and to determine if plating APMT®, a specific highly oxidation-resistant ODS FeCrAl alloy made by Kanthal, onto nickel-based superalloy turbine parts is a viable method for substantially improving the lifetimes and maximum use temperatures of the parts. The superalloys investigated for protection were CM247LC and Rene® 80, both alumina scale-forming alloys. The method for bonding the APMT plate to the superalloys is called evaporative metal bonding, which involves placing a thin foil of zinc between the plate and the superalloy, clamping them together, and heating in an atmosphere-controlled furnace. Upon heating, the zinc melts and dissolves the oxide skins of the alloys at the bond line, allowing the two alloys to diffuse into each other. The zinc then diffuses through the alloys and evaporates from their surfaces, creating a bond between the APMT and the superalloy that is stronger than the APMT itself. Testing showed that the diffusivity of zinc in both APMT and CM247LC is quite similar at 700°C but 15 times higher in the APMT at 1214°C. Coefficients of thermal expansion were determined for each of the alloys as a function of temperature. This information was entered into a finite-element model using ANSYS, which was used to design a clamping jig for pressing the APMT to the superalloys at the bonding temperature. Scanning electron microscopy analyses of representative joints showed that no zinc remained in the alloys after bonding Unfortunately, the analyses also showed some small pieces of broken aluminum oxide scale near the bond lines, indicating that its scale was not sufficiently removed during prebonding cleaning. Samples from each of the bonded blocks were sent to Siemens for its standard oxidation, spallation, and corrosion testing, which was scheduled for completion in the spring of 2016. However, because of commercial demands, the tests were not completed by the time of this report except some initial spallation tests at 1150°C. In those tests, several of the APMT plates separated from the CM247LC, likely because of the remaining aluminum oxide scale on the surface of the CM247LC. This implies that surface preparation may need to include machining to remove the oxide scale before bonding rather than just sandblasting. In previous tensile testing at 950°C, the breaks in the tensile samples always occurred in the APMT and not at the joints. Gasifier sampling was completed to determine what types of trace contaminants may occur in cleaned and combusted syngas and that could lead to corrosion or deposition in turbines firing coal syngas. The sampling was done from a pressurized fluidized-bed gasifier and a pressurized entrained-flow gasifier. The particles captured on a filter from syngas were typically 0.2 to 0.5 μm in diameter, whereas those captured from the combusted syngas were slightly larger and more spherical. X-ray photoelectron spectroscopy done at Oak Ridge National Laboratory showed that the particles do not contain any metals and have an atomic composition almost identical to that of the polycarbonate filter. This indicates that the particles are primarily soot-based and not formed from volatilization of metals in the gasifiers.

20 FOSSIL-FUELED POWER PLANTS↗

Oxy-Combustion Environmental Characterization: Fire- and Steam-Side Corrosion in Advanced Combustion

Steamside Oxidation: A first high pressure test was completed, 293 hr at 267 bar and 670°C; A parallel 1 bar test was done for comparison; Mass gains were higher for all alloys at 267 bar than at 1 bar. A comparison was made with longer-term literature data: Ferritic steels--no consistent pressure effect; Austenitic steels--fine grain alloys less able to maintain protective chromia scale as pressure increases; Ni-base alloys--more mass gains above 105 bar than below. Not based on many data points. Fireside Corrosion: 1. Conditions for most severe corrosion: Temperature: 700{degrees}C Deposit: Standard Corrosion Mix Duration: 160 hours Gas Atmosphere: O{sub 2} + 1000ppm SO{sub 2} Pt-catalyst placed in the hot zone next to the specimens 2. Possible SO{sub 2} threshold in gas atmosphere for corrosion; 3. Corrosion greater in steel alloys than Ni-based alloys; 4. Corrosion mechanism proposed for steel alloys and Ni-based alloys.

36 MATERIALS SCIENCE↗

Development of Corrosion- and Erosion-Resistant Coatings for Advanced Ultra-Supercritical Materials

This final report summarized the research efforts and major findings of the Phase I Project “Development of Corrosion- and Erosion-Resistant Coatings for Advanced Ultra-Supercritical Materials”, for the period of October 1, 2019 – Sept. 30, 2021. This project is a collaborative endeavor between Tennessee Tech University, Purdue University, Oak Ridge National Laboratory, Siemens Corporation, and Eastern Plating, LLC, aiming at improving the durability and lifetime of high-pressure (HP) steam turbine blades in advanced ultra-supercritical (A-USC) coal-fired power plants through the development of corrosion/erosion-resistant coatings manufactured via a low-cost electrolytic codeposition process. While Tribaloy alloy T-400C was identified by the U.S. A-USC Materials Consortium as a promising coating composition, further composition optimization is needed to enhance its corrosion and erosion resistance for protecting the A-USC Ni-base turbine components. An integrated computational and experimental approach was employed to optimize coating composition/microstructure and processing parameters. In order to identify candidate coating compositions that could offer balanced properties, thermodynamic calculations were performed to explore the γ+Laves composition space in the Co-Ni-Cr-Mo-Si system with different alloying additions at 600-800 °C. Guided by the calculation results, experimental assessment of selected alloys led to the development of a new generation of Tribaloy compositions with the optimal levels of Cr, Mo and Si, reactive element (e.g., 0.4-0.6 wt.% Y) and other alloying additions. The low-cost and non-line-of-sight electro-codeposition process was employed to deposit a Ni(Co)-CrMoSiY composite coating on commercial Haynes 282 (H282) Ni-base alloy. A diffusion treatment was subsequently applied to convert the composite to the Tribaloy-type coating. Both the codeposition parameters and heat treatment conditions were varied to achieve the desired coating composition, microstructure and phase constituents. In addition, since additive manufacturing (AM) may be an alternative cost-saving option for potential A-USC turbine repair, laser direct deposition was explored to fabricate the H282 alloy with minimal defects. The electro-codeposited Tribaloy coating was also applied to the AM H282 substrate to demonstrate the viability of the coating process in improving the surface finish of AM alloys. Both high-temperature oxidation performance and solid particle erosion (SPE) resistance of model alloys and electro-codeposited coatings were evaluated. About 25 model alloys with various Cr/Mo ratios and reactive element levels, as well as partial substitution of Mo with Nb were evaluated with regard to their oxidation resistance in both air and pure steam at 760-800°C. Compositions based on Ni(Co)-20Cr-18Mo-2.6Si-0.6Y (wt.%) showed significantly improved oxidation resistance over the baseline T400-C. Based on the alloy development results, three generations of new Tribaloy coatings (Gen-1, Gen-2, and Gen-3) with various Mo/Cr contents and Y levels were prepared via electro-codeposition and their microstructure/performance were evaluated. Outstanding air and steam oxidation resistance was achieved for the Gen-2 and Gen-3 coatings. Furthermore, while the SPE resistance of the coatings depended on many factors such as temperature, environment, erodent, velocity and impact angle, the coated samples exhibited similar or better SPE resistance compared to the H282 substrate when magnetite was used as erodent (which is a realistic erodent in A-USC steam turbines). The new Tribaloy coatings also had good long-term compatibility with the H282 alloy substrate. The two large-sized rotating barrels were designed, constructed, and employed to coat dummy HP blades. Uniform coating thickness and microstructure were achieved at various blade locations. Also, a preliminary techno-economic analysis of the proposed coating process was conducted to quantify the cost-effectiveness and to assess the commercial viability of the corrosion- and erosion-resistant coatings. It is estimated that a cost reduction of ~30% could be achieved with the electro-codeposition coating process over the state-of-the-art high velocity oxygen fuel (HVOF) thermal spray. Compared to the leading Tribaloy coating technologies such as HVOF and plasma transfer alloying, electro-codeposition based process has advantages such as low-cost process equipment, uniform deposition even for complex shapes, low levels of contaminants/porosities, reduction of powder waste, and potentially better surface finish and longer turbine service life. The Phase 1 study has demonstrated that it is feasible to develop an electro-codeposited Tribaloy coating with balanced corrosion and erosion properties, even though additional research efforts such as further coating process scale-up and longer-term performance evaluation under realistic A-USC conditions are clearly needed.

20 FOSSIL-FUELED POWER PLANTS↗

Superheater Corrosion Produced By Biomass Fuels

About 90% of the world's bioenergy is produced by burning renewable biomass fuels. Low-cost biomass fuels such as agricultural wastes typically contain more alkali metals and chlorine than conventional fuels. Although the efficiency of a boiler's steam cycle can be increased by raising its maximum steam temperature, alkali metals and chlorine released in biofuel boilers cause accelerated corrosion and fouling at high superheater steam temperatures. Most alloys that resist high temperature corrosion protect themselves with a surface layer of Cr{sub 2}O{sub 3}. However, this Cr{sub 2}O{sub 3} can be fluxed away by reactions that form alkali chromates or volatilized as chromic acid. This paper reviews recent research on superheater corrosion mechanisms and superheater alloy performance in biomass boilers firing black liquor, biomass fuels, blends of biomass with fossil fuels and municipal waste.

09 BIOMASS FUELS↗

Review on Preprocessing Strategies, Deactivation, Thermal Safety, and Future Perspectives in Lithium-Ion Battery Recycling

The rapid growth in the use of lithium-ion batteries (LIBs) in electric vehicles, consumer electronics, and renewable energy storage has made effective end-of-life management essential. Recycling LIBs is critical not only for resource recovery and environmental protection but also for ensuring safety and economic viability. This review focuses on the preprocessing technologies that precede typical recovery processes, including disassembly, sorting, discharging, electrolyte removal, dismantling, thermal treatment, separation, and flotation. These steps play a foundational role in determining the efficiency, safety, and environmental impact of LIB recycling. LIBs pose substantial fire and explosion risks due to residual charge, flammable electrolytes, and reactive materials. The conditions and successive progression of the exothermic reactions which lead to thermal runaway has been discussed. It also explores secure deactivation techniques such as external circuit discharge, saline immersion, and thermomechanical methods, alongside fire prevention strategies including the use of flame retardants, elimination of oxidants, and reduction of heat generation and accumulation. Challenges and future directions are outlined, highlighting the need for standardized designs, automation, and safer, more sustainable recycling infrastructure. Furthermore, this review is distinguished by its focused analysis of preprocessing and deactivation steps, with particular attention to the thermal safety engineering aspects of LIB recycling.

Battery deactivation↗

Toward improved thermal exposure classes for structural firefighters

In the early 1970s, there was an initial effort to quantify the conditions under which firefighters are expected to perform. Harvey Utech led this endeavor by defining three levels of thermal exposure—routine, ordinary, and emergency—which were characterized by combining a range of air temperatures and radiative heat fluxes. In the last half-century, there has been a concerted scientific effort to further understand the conditions to which firefighters are exposed during structural firefighting. Research has been conducted on the resiliency of turnout gear and facepiece lenses, the thermal conditions observed during a structure fire, and the impact of firefighter tactics such as ventilation and suppression. The authors synthesize the results from these research areas to update the original thermal classifications to six categories of exposure—routine, Ordinary I, Ordinary II, Emergency I, Emergency II, and Emergency III—which are more representative of the operating environment and protective equipment thresholds that firefighters should be aware of during firefighting operations and tactical decision-making.

Weinschenk, Craig↗

Developing an Operational Capabilities Index of the Emergency Services Sector

In order to enhance the resilience of the Nation and its ability to protect itself in the face of natural and human-caused hazards, the ability of the critical infrastructure (CI) system to withstand specific threats and return to normal operations after degradation must be determined. To fully analyze the resilience of a region and the CI that resides within it, both the actual resilience of the individual CI and the capability of the Emergency Services Sector (ESS) to protect against and respond to potential hazards need to be considered. Thus, a regional resilience approach requires the comprehensive consideration of all parts of the CI system as well as the characterization of emergency services. This characterization must generate reproducible results that can support decision making with regard to risk management, disaster response, business continuity, and community planning and management. To address these issues, Argonne National Laboratory, in collaboration with the U.S. Department of Homeland Security (DHS) Sector Specific Agency - Executive Management Office, developed a comprehensive methodology to create an Emergency Services Sector Capabilities Index (ESSCI). The ESSCI is a performance metric that ranges from 0 (low level of capabilities) to 100 (high). Because an emergency services program has a high ESSCI, however, does not mean that a specific event would not be able to affect a region or cause severe consequences. And because a program has a low ESSCI does not mean that a disruptive event would automatically lead to serious consequences in a region. Moreover, a score of 100 on the ESSCI is not the level of capability expected of emergency services programs; rather, it represents an optimal program that would rarely be observed. The ESSCI characterizes the state of preparedness of a jurisdiction in terms of emergency and risk management. Perhaps the index's primary benefit is that it can systematically capture, at a given point in time, the capabilities of a jurisdiction to protect itself from, mitigate, respond to, and recover from a potential incident. On the basis of this metric, an interactive tool - the ESSCI Dashboard - can identify scenarios for enhancement that can be implemented, and it can identify the repercussions of these scenarios on the jurisdiction. It can assess the capabilities of law enforcement, fire fighting, search and rescue, emergency medical services, hazardous materials response, dispatch/911, and emergency management services in a given jurisdiction and it can help guide those who need to prioritize what limited resources should be used to improve these capabilities. Furthermore, this tool can be used to compare the level of capabilities of various jurisdictions that have similar socioeconomic characteristics. It can thus help DHS define how it can support risk reduction and community preparedness at a national level. This tool aligns directly with Presidential Policy Directive 8 by giving a jurisdiction a metric of its ESS's capabilities and by promoting an interactive approach for defining options to improve preparedness and to effectively respond to a disruptive event. It can be used in combination with other CI performance metrics developed at Argonne National Laboratory, such as the vulnerability index and the resilience index for assessing regional resilience.

99 GENERAL AND MISCELLANEOUS↗

Mitigation for the demolition of building 25-3153, fire station, area 25, Nevada national security site, NYE county, Nevada

The purpose of this letter report is to document the mitigation of adverse effects of a proposed undertaking that would demolish Building 25-3153 in Area 25 of the Nevada National Security Site (NNSS) in compliance with the terms of the 2024 Programmatic Agreement among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (NNSS PA). Building 25-3153 (State Historic Preservation Office [SHPO] Resource # B19004) is a contributing element to the Nuclear Rocket Development Station (NRDS) Historic District (SHPO Resource # D424), which has been determined eligible for listing in the National Register of Historic Places (NRHP) under Criteria A, B, C, and D (Reno et al. 2023). The proposed demolition constitutes an adverse effect. The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) consulted with the SHPO on an adverse effect finding for the undertaking and notified the SHPO of its intent to use the standard mitigation in the NNSS PA on December 11, 2024 (Julian to Reed). The SHPO concurred on December 30, 2024 (Reed to Julian). Therefore, NNSA/NFO has prepared mitigation pursuant to the standard mitigation in the NNSS PA Appendix D.I.A for contributing elements to recorded, NRHP-eligible districts.

#B19004↗

Tropical root responses to global changes: A synthesis

Tropical ecosystems face escalating global change. These shifts can disrupt tropical forests' carbon (C) balance and impact root dynamics. Since roots perform essential functions such as resource acquisition and tissue protection, root responses can inform about the strategies and vulnerabilities of ecosystems facing present and future global changes. However, root trait dynamics are poorly understood, especially in tropical ecosystems. We analyzed existing research on tropical root responses to key global change drivers: warming, drought, flooding, cyclones, nitrogen (N) deposition, elevated (e) CO 2 , and fires. Based on tree species- and community-level literature, we obtained 266 root trait observations from 93 studies across 24 tropical countries. We found differences in the proportion of root responsiveness to global change among different global change drivers but not among root categories. In particular, we observed that tropical root systems responded to warming and eCO 2 by increasing root biomass in species-scale studies. Drought increased the root: shoot ratio with no change in root biomass, indicating a decline in aboveground biomass. Despite N deposition being the most studied global change driver, it had some of the most variable effects on root characteristics, with few predictable responses. Episodic disturbances such as cyclones, fires, and flooding consistently resulted in a change in root trait expressions, with cyclones and fires increasing root production, potentially due to shifts in plant community and nutrient inputs, while flooding changed plant regulatory metabolisms due to low oxygen conditions. The data available to date clearly show that tropical forest root characteristics and dynamics are responding to global change, although in ways that are not always predictable. This synthesis indicates the need for replicated studies across root characteristics at species and community scales under different global change factors.

54 ENVIRONMENTAL SCIENCES↗

Water Network Tool for Resilience (WNTR)

The Water Network Tool for Resilience (WNTR) is an open source Python package designed to simulate and analyze resilience of water distribution networks. The United States Environmental Protection Agency, in partnership with Sandia National Laboratories, developed WNTR to integrate critical aspects of resilience modeling for water distribution networks into a single software framework. The software includes capability to: • Generate water network models • Modify network structure and operations • Assign fragility and survival curves to network components • Model disruptive events such as power outages, earthquakes, fires, pipe breaks, and contamination incidents • Model response and repair strategies • Simulate hydraulics and water quality • Evaluate resilience using a wide range of metrics • Integrate dependency with other critical infrastructure and supply chains • Analyze results and generate graphics SAND2019-450 M

Villa, Daniel↗

Analysis of beam loss induced abort kicker instability

Through more than a decade of operation, we have noticed the phenomena of beam loss induced kicker instability in the RHIC beam abort systems. In this study, we analyze the short term beam loss before abort kicker pre-fire events and operation conditions before capacitor failures. Beam loss has caused capacitor failures and elevated radiation level concentrated at failed end of capacitor has been observed. We are interested in beam loss induced radiation and heat dissipation in large oil filled capacitors and beam triggered thyratron conduction. We hope the analysis result would lead to better protection of the abort systems and improved stability of the RHIC operation.

43 PARTICLE ACCELERATORS↗

Report of the Interagency Task Force on Carbon Capture and Storage

Carbon capture and storage (CCS) refers to a set of technologies that can greatly reduce carbon dioxide (CO{sub 2}) emissions from new and existing coal- and gas-fired power plants, industrial processes, and other stationary sources of CO{sub 2}. In its application to electricity generation, CCS could play an important role in achieving national and global greenhouse gas (GHG) reduction goals. However, widespread cost-effective deployment of CCS will occur only if the technology is commercially available and a supportive national policy framework is in place. In keeping with that objective, on February 3, 2010, President Obama established an Interagency Task Force on Carbon Capture and Storage composed of 14 Executive Departments and Federal Agencies. The Task Force, co-chaired by the Department of Energy (DOE) and the Environmental Protection Agency (EPA), was charged with proposing a plan to overcome the barriers to the widespread, cost-effective deployment of CCS within ten years, with a goal of bringing five to ten commercial demonstration projects online by 2016. Composed of more than 100 Federal employees, the Task Force examined challenges facing early CCS projects as well as factors that could inhibit widespread commercial deployment of CCS. In developing the findings and recommendations outlined in this report, the Task Force relied on published literature and individual input from more than 100 experts and stakeholders, as well as public comments submitted to the Task Force. The Task Force also held a large public meeting and several targeted stakeholder briefings. While CCS can be applied to a variety of stationary sources of CO{sub 2}, its application to coal-fired power plant emissions offers the greatest potential for GHG reductions. Coal has served as an important domestic source of reliable, affordable energy for decades, and the coal industry has provided stable and quality high-paying jobs for American workers. At the same time, coal-fired power plants are the largest contributor to U.S. greenhouse gas (GHG) emissions, and coal combustion accounts for 40 percent of global carbon dioxide (CO{sub 2}) emissions from the consumption of energy. EPA and Energy Information Administration (EIA) assessments of recent climate and energy legislative proposals show that, if available on a cost-effective basis, CCS can over time play a large role in reducing the overall cost of meeting domestic emissions reduction targets. By playing a leadership role in efforts to develop and deploy CCS technologies to reduce GHG emissions, the United States can preserve the option of using an affordable, abundant, and domestic energy resource, help improve national security, help to maximize production from existing oil fields through enhanced oil recovery (EOR), and assist in the creation of new technologies for export. While there are no insurmountable technological, legal, institutional, regulatory or other barriers that prevent CCS from playing a role in reducing GHG emissions, early CCS projects face economic challenges related to climate policy uncertainty, first-of-a-kind technology risks, and the current high cost of CCS relative to other technologies. Administration analyses of proposed climate change legislation suggest that CCS technologies will not be widely deployed in the next two decades absent financial incentives that supplement projected carbon prices. In addition to the challenges associated with cost, these projects will need to meet regulatory requirements that are currently under development. Long-standing regulatory programs are being adapted to meet the circumstances of CCS, but limited experience and institutional capacity at the Federal and State level may hinder implementation of CCS-specific requirements. Key legal issues, such as long-term liability and property rights, also need resolution. A climate policy designed to reduce our Nation's GHG emissions is the most important step for commercial deployment of low-carbon technologies such as CCS, because it will create a stable, long-term framework for private investments. A concerted effort to properly address financial, economic, technological, legal, institutional, and social barriers will enable CCS to be a viable climate change mitigation option that can over time play an important role in reducing the overall cost of meeting domestic and global emissions reduction targets. Federal and State agencies can use existing authorities and programs to begin addressing these barriers while ensuring appropriate safeguards are in place to protect the environment and public health and safety.

01 COAL, LIGNITE, AND PEAT↗

Andra's strategy and approach for operational safety of French underground facility Cigeo - 15127

According to the French Act on radioactive waste of 28 June 2006, Andra shall design a reversible repository. In response to this demand, Andra is developing the industrial project namely 'Cigeo', a reversible geological disposal facility for HLW and ILW located in Meuse/Haute-Marne. The previous safety cases of 2005, 2009 and 2012 give a sound basis to assess Cigeo's safety both for the operational and post-closure periods. Regarding operational safety, in this new stage of the project, the challenging issues for the preparation of the safety case are the following: - To adapt the various regulatory frameworks (nuclear and non-nuclear) to the underground facility - To design the underground facility and handling equipment's to reduce at first risks in the underground facility as such radioactive particles release, gas explosion, fire and co-activity and limit their consequence. - To establish waste acceptance criteria to be fulfilled by waste producers in line with operational safety and design options. The objective of the paper is to present the experience of Andra in operation safety of the underground facility of Cigeo. Operational safety for Cigeo is assessed as much as possible according to the existing French regulations and guidance for nuclear facilities. Indeed, compared to existing nuclear facilities, a geological repository is a specific case due to the existence of underground facilities with particularities such as: - ventilation management in a large scale underground facility, - fire risk management. As an input for the industrial design of Cigeo for operation, Andra defined a fire guidance and a specific reference safety guidance, based on the adaptation of the French nuclear regulatory texts for and when feasible to mines and tunnels regulatory texts and on its own experience gained through safety operational reports since 2005 and their reviews by the Safety Authority. - underground co-activity of nuclear operation with construction works. According to the common 'defense-in depth' principle for nuclear facilities, these guidelines for the industrial design of Cigeo for operation consider the successive levels of defense of: - Preventing the risk and its spreading by design and construction; - Detecting incidents and early fighting by design and operation dispositions (detection and control systems, survey procedure); - Controlling incidents and limiting of their consequences by safeguarding systems, specific procedures. At that stage, design options for Cigeo constitute an adequate response to the operational safety functions and requirements: - Two levels of containment are set up: the first one is ensured by the waste package, the second one is ensured from the surface facility to the disposal vaults by the transfer cask during the transfer of waste packages in the disposal vaults by the disposal vault itself and a nuclear ventilation with HEPA filter; - Favorable options for fire risk prevention and mitigation: transport system minimizing heat load (cable car for the transfer from the surface, electric transfer engines), twin access tunnels to ease fire-fighting and evacuation...; - Permanent complete physical separation of nuclear zone and construction zone (including ventilation systems). In practice, operation safety assessment of Cigeo, designed following the aforesaid reference safety guidelines, follows a common risk analysis (internal aggressions such as auxiliary losses, chemical and toxic risks, fall or collision, fire, human factors and external aggressions such as earthquake, air traffic, flooding) with the following steps: - Identification of the major risks and the design basis scenarios that have to be considered for dimensioning of the installations and the safety devices; - On the basis of these different situations, those who will have to be quantified are identified; one or more representative and envelop situations are chosen in order to evaluate robustness of the installation. Quantitative evaluation of these situations permits to: - identify the consequences on man, environment and installation, and in particular to gain confidence in the maintaining of the safety functions; - identify or define the technic and/or organisational dispositions classified as 'important elements for protection' (IEP); - Situations beyond dimensioning permit to verify the robustness of the installation. They permit, on one hand to identify possible complementary material or organisational dispositions; on the other hand, to define the 'hard core' i.e. structures, systems and components that permit to maintain the confinement function of radioactive substance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of AG-1 FC Filters Under Upset Conditions and the Effects of Aging on Filters - 19501

High efficiency particulate air (HEPA) filters are routinely used in nearly every operating Department of Energy (DOE) and National Nuclear Safety Administration (NNSA) nuclear facility. These nuclear grade HEPA filters installed in DOE and NNSA confinement ventilation systems are credited as the final barrier to protect the environment, the public, and the worker from accidental release of virtually all airborne radioactive materials, and must meet the American Society of Mechanical Engineers' (ASME) Code on Nuclear Air and Gas Treatment (CONAGT) AG-1 standard. This testing activity evaluates ASME AG-1 Section FC axial flow HEPA filters, both separator and separator-less, under upset conditions. Additionally, testing efforts have analyzed the effects of filter degradation due to aging. In 1997, the Defense Nuclear Facilities Safety Board (DNFSB) raised concerns of the potential vulnerability of HEPA filters in vital safety systems, both from a design stand point and the potential for degradation of HEPA filter performance over time. The DOE Office of Environmental Management (DOE-EM) has a Cooperative Agreement with Mississippi State University (MSU) Institute for Clean Energy Technology (ICET) to conduct testing of HEPA filters. DOE-EM has established a Technical Working Group (TWG) of over thirty subject matter experts from the nuclear industry to provide input and oversight of ICET projects and activities. This has included establishment/approval of testing parameters for evaluating these filters under ASME NQA-1 compliant Test Plans. The current scope of work involves evaluation of the performance envelope for new and aged separator and separator-less designs of AG-1 Section FC axial flow HEPA filters. A range of elevated test conditions (T and RH) are used to determine the operating envelope within which DOE nuclear safety experts can credit installed HEPA filter performance, thereby establishing a risk-informed DOE service life. This paper will present preliminary test results of new and aged axial flow filters tested at ICET. Results in this paper include data collected from new separator and separator-less type FC HEPA filters and equivalent test data for a limited group of aged separator and separator-less type FC HEPA filters. Testing for both scopes of work evaluate initial filter performance under ambient conditions of temperature (60 deg. F - 80 deg. F (∼16 - ∼27 deg. C)) and relative humidity (40-60%), loading of each filter with Aluminum Trihydroxide, Al(OH)3, to a specified differential pressure, and then exposing the filter to specified elevated temperature and relative humidity conditions. In addition to the upset conditions of elevated temperature and relative humidity, the performance of HEPA filters under fire scenarios is not well characterized. ICET is currently designing a burn box and testing apparatus to study the effects of fire from burning liquids and a wide range of blends of combustible solids. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗